EcoStar Majestic Slate Roofing System

Similar documents
MAJESTIC NIAGARA SLATE ECOSTAR GOLD STAR ROOF SYSTEM

EMPIRE NIAGARA SLATE ECOSTAR GOLD STAR ROOF SYSTEM

MAJESTIC SLATE ECOSTAR GOLD STAR ROOF SYSTEM

MAJESTIC SLATE CLASS A ECOSTAR GOLD STAR ROOF SYSTEM SPECIFICATIONS

SENECA SHAKE TILES ECOSTAR GOLD STAR ROOF SYSTEM

MAJESTIC SLATE ECOSTAR GOLD STAR ROOF SYSTEM

EMPIRE SLATE ECOSTAR GOLD STAR ROOF SYSTEM

2006 PRICE LIST. PRODUCT NAME DESCRIPTION PAGE Policies Freight policy and material return policy. 1. Product Reference Table. Majestic Slate Tile

Sustainable Roofing. Eco-friendly synthetic slate & shake roofing tiles proudly made in the USA

PRODUCT EVALUATION Effective Date: July 1, 2014 RC-20

CARLISLE S BALLASTED ROOFING SYSTEMS COST EFFICIENT RECYCLABLE ENERGY EFFICIENT

BALLASTED ROOFING SYSTEMS COST EFFICIENT RECYCLABLE SUSTAINABLE

Sustainable Roofing Majestic & Empire Slate Seneca & Empire Shake

Sustainable Roofing Majestic & Empire Slate Seneca & Empire Shake

Installation and Maintenance Manual

TERMS AND CONDITIONS

Rapid Digestor Fume Removal System

Synthetic Slate and Shake. Highly Sustainable Tested Performance Proven Longevity Uncompromised Beauty

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

ATN3580 Series: Fixed Attenuator Pads

Universal Bevel Drives Service Manual

Code Compliance Research Report CCRR-0258

READ AND SAVE THESE INSTRUCTIONS

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility

PERFORMANCE TEST REPORT. Rendered to: AIR VENT, INC. SERIES/MODEL: Hip Ridge Vent PRODUCT TYPE: Ridge Vent

Standard filter Disk filter Return filter. Lubrication systems can fail from the following

Installation. Storage. Tools

Model Description Vac. Max rating Pedestal Only: 36 Utility Pedestal W/O Disconnect General Duty Series:

Model Series 66 Amplifying and Reducing Relays

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

CREEK Technical Services, LLC

Float Level Control Kits

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

SUGGESTED SPECIFICATIONS Pump Frames NS3 thru OMC5

OV-1 STANDING SEAM OVERVIEW. Temple Architectural Products 638 Moore Rd Avon Lake, OH 44012

TECH BULLETIN. SIP No. Subject: Fiber Cement Siding from James Hardie. Date: February 2010 (Revised November 2015)

O & M Manual for the EATON Generator Ready Loadcenter

General Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting

ROLLER GATES. Waterman Industries of Egypt. Roller gates are nominated for heavy duty service where large loads and sizes are going to be encountered.

Guardian Taper Grid Shaft Coupling

ARALDITE AV 8574 Resin Hardener HV 8574

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS

Professional Weather Center

Installation Manual. Installation Manual. AXITEC, LLC 160 Greentree Drive, Suite 101 Dover, Delaware

SIGMADUR PRODUCT DATA SHEET December 12, 2014 (Revision of January 1, 2013) DESCRIPTION. Two-component, high solids polymeric urethane

Standard filter Disk filter Return filter. Lubrication systems can fail from the following

Hi-Flo ES. Energy saving pocket filter with guaranteed lifetime efficiency. Energy Saving, Extended Surface Area, High Efficiency Air Filter

SEMITOP2,3,4 Press-Fit

INSTALLATION MANUAL. IEC version. TSM_IEC_IM_2012_RevB

Starting up hydraulic systems

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S

INSTALL GUIDE Silverado/Sierra L/6.2L

BP Certified roofer REFERENCE MANUAL. BPC_CR_ReferenceManual_c1c4_EN.indd 1

System 3 ZB1PS Device Chassis. Operator s Manual

Turbo-House Air Inlet Installation & Operator s Instruction Manual

INSTALLATION INSTRUCTIONS

Double Scull Car Rack User s Manual

1 1 4" System. Fiberglass System. Special Metals. PrimeAngle. Metal Grating. Roofwalk. Index. Loads and Deflection 6" Planks.

JCM 101 Universal Clamp Couplings

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE

STREAMLINED SOLAR CHECKLIST Owner Name:

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

INSTALLATION DATA MANUAL. Model 521/522 Pressure Transmitter

Cougar B Series Electric Vibrators 3 Frame

INSTALLATION DATA MANUAL Model 510 Pressure Transmitter

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

SKF fan upgrade services. One source for a full range of solutions, from unique bearing systems to circulating oil lubrication systems

Advanced PCO System. Installation Instructions & Consumer Information. Section I. Important Installer Information WARNINGS

Rotary Cutter Drives Service Manual

Shops Enter Repair and Failure Information for Plants

ST. TAMMANY PARISH COUNCIL ORDINANCE

Power Inverter 400 MW Owner s Manual

BOISE GLULAM 24F-V4 IJC

Complete Component Catalog

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

Piston Seals Wipers O-Rings & Kits Custom Parts Specialty Parts Services Wear Guides Rod Seals UL Compounds QUALITY VALUE SERVICE.

Electric Vehicle Charging Station

Phantom Screen s Motorized Retractable Screens Are the Only Choice

RGZESDI Inverter Duty AC Induction Motors

Mounting Instruction MiniSKiiP

STāSIS Engineering R8 Brake System

Model 6 Weld-On Drawbar Eye

B2. Fueling Operations

GENERAL PLAN APPROVAL AND GENERAL OPERATING PERMIT BAQ-GPA/GP 2 STORAGE TANKS FOR VOLATILE ORGANIC LIQUIDS

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Installation and Maintenance Manual CEMLINE CORPORATION

HIGH VOLTAGE DIGITAL AMMETER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

TS Series TS Series

Central Florida Regional Transportation Authority d.b.a.

AUO Photovoltaic Module Installation Manual. Version 2.0

Price Book - New England States We ve Got You Covered States served: CT, MA, ME, NH, NY, RI, VT Rev 01-18

TECHNICAL DATA SHEET Artisan Lap Siding

INSTALLATION INSTRUCTIONS

Transcription:

EcoStar Majestic Slate Roofing System General Design & Planning Criteria Table of Contents Page A. Description...2 B. Design Considerations...2 C. Quality Assurance...3 D. Warranty...4 E. Code Approvals...4 F. Roof Deck/Substrate...4 G. Snow Retention Systems...5 EcoStar Manual- Updated 4/2015 EcoStar General Design & Planning 2015 2015 EcoStar LLC. EcoStar, Majestic Slate, Seneca Shake, Seneca Plus, Empire Slate, Empire Shake, Empire Plus, Aqua Guard, Glacier Guard and EcoVent are all trademarks of EcoStar LLC.

EcoStar Majestic Slate Gold Star Roof System General Design & Planning Criteria The information contained herein is to serve as criteria for specifiers and roofing professionals regarding the design and planning of EcoStar s Majestic Slate Gold Star roofing system. Specifiers and roofing professionals are advised to fully familiarize themselves with this section and the applicable Installation section(s) prior to completing the project specifications. Information pertaining to the EcoStar products utilized with this roofing system can be found in the Products section included in this manual. A. DESCRIPTION The EcoStar Majestic Slate Gold Star Roofing System incorporates the use of a 1/4 tapered nominal thickness, 18 long by 10 or 12 wide polymeric rubber roofing tile. EcoStar Glacier Guard and EcoStar Aqua Guard underlayments are attached to an approved roof decking. The EcoStar Majestic Slate is then attached using two EcoStar stainless steel ring shank fasteners according to current published EcoStar installation specifications. EcoStar Majestic Slate Universal Hip & Ridge tiles are then attached at all hip and ridge locations. B DESIGN CONSIDERATIONS 1. The following projects should be sent to EcoStar for review prior to installation and preferably prior to bid to ensure that EcoStar s minimum warranty requirements are met: a. Projects with a roof decking other than minimum 1/2 plywood, 7/16 OSB or 3/4 tongue and groove decking with end gaps not exceeding ¼. b. Projects with a roof slope less than three inches to the horizontal foot. c. Projects over 150 feet in height. 2. Projects with a requested wind speed warranty higher than 90 mph will require additional enhancements. Contact the EcoStar Technical Department for applicable requirements. 3. Projects with a requested Class A fire rating will require additional enhancements. Refer to product specifications for underlayment and installation requirements. 2

4. Petroleum-based products (plastic roofing cement), certain chemicals and waste products (i.e., grease, oil, animal fats, etc.) are not compatible with this roof system. Please contact EcoStar s technical department for verification of compatibility and recommendations concerning an acceptable roofing assembly. 5. It is the responsibility of the specifier or roofing professional to review local, state and regional codes to determine their impact on the EcoStar roofing system. 6. All ventilation or air movement systems must be in accordance with local building codes. The specifier, building owner, or roofing professional must review this prior to installation. Local codes will ultimately supersede any EcoStar ventilation details. Furthermore EcoStar is not responsible for specifying proper air movement within a project. 7. Tear-Off Projects a. All existing roofing material must be removed down to the roof decking before installing the EcoStar Majestic Slate Gold Star roofing system. It is the responsibility of the owner or their designate to ensure that the roof decking is suitably flush to accept the EcoStar roof assembly. Installing EcoStar tiles on deflected or warped decking may result in aesthetic issues. C. QUALITY ASSURANCE 1. EcoStar requires the use of EcoStar supplied products where available for use with an EcoStar roofing system. The performance or integrity of products by others, when selected by the specifier and accepted as compatible by EcoStar, are not the responsibility of EcoStar and is disclaimed by the EcoStar warranty. 2. An EcoStar authorized roofing contractor must install the specified roofing system. 3. There must be no deviations made from EcoStar s specifications, EcoStar s approved shop drawings and submittals without the prior written approval of EcoStar. 4. After completion of the installation, the authorized roofing contractor must contact EcoStar s warranty coordinator to arrange for an inspection to be conducted by an EcoStar Field Service Representative to ascertain that the roofing system has been installed according to EcoStar s published specifications and details applicable at the time of bid. This inspection is for the benefit of EcoStar to determine whether a warranty shall be issued. 3

D. WARRANTY 1. A Limited Labor and Material Warranty is available and applies only to products manufactured or marketed by EcoStar. The roofing system is defined as the roof tiles, underlayments, accessories and any other EcoStar brand products utilized in the installation. Products not manufactured by EcoStar are subject to third party manufacturer s warranty. 2. EcoStar Gold Star warranted projects will receive a peak gust wind speed of 90 mph unless prior review is performed and approval has been granted by EcoStar regarding an extended peak gust wind speed coverage. 3. The formation or presence of mold or fungi in a building is dependent upon a broad range of factors including but not limited to, the presence of spores and nutrient sources, moisture, temperatures, climatic conditions, relative humidity, and heating/ventilating systems and their maintenance and operating capabilities. These factors are beyond the control of EcoStar and EcoStar shall not be responsible for any claims, repairs, restoration or damages relating to the presence of any irritants, contaminants, vapors, fumes, molds, fungi, bacteria, spores, mycotoxins, or the like in any building or in the air, land, or water serving the building. EcoStar disclaims responsibility for the aesthetics or cleanliness of the roofing system caused by environmental conditions including, but not limited to, dirt, pollutants, or biological agents, and discoloration caused by or resulting from initial installation. E. CODE APPROVALS 1. Building codes are above and beyond the intended purpose of these specifications. The respective owner or specifier should consult local codes for applicable requirements and limitations. 2. For code approvals achieved with the EcoStar Majestic Slate roofing system, refer to Underwriters Laboratories (UL) Fire Resistance or Roofing Materials and Systems Directories or contact EcoStar s technical department. F. ROOF DECK/SUBSTRATE 1. Proper decking shall be provided by the building owner. The building owner or his/her designated representative must ensure that the building structure is investigated by a registered engineer to assure its ability to withstand the total weight of the specified roofing system as well as construction load and live loads in accordance with all applicable codes. The building owner or its designated representative must also ensure that the roof decking is suitably flat to accept the EcoStar roofing system. Aesthetic concerns may arise from installing EcoStar tiles on deflected or warped decking. 4

G. SNOW RETENTION SYSTEMS Caution: In regions where snow accumulation is common we strongly recommend that a properly designed snow retention system be incorporated into any EcoStar roof assembly. Accumulated snow may slide off of the roof all at once endangering people and property. An effective snow retention system should be designed by an architect or the manufacturer of the snow retention products to be used. Contact the EcoStar Technical Department with any questions concerning the compatibility of snow retention systems with EcoStar Roofing Tiles. 5