MICROWAVE CHECKER. User Manual Issue 1.4. e: w: Microwave Checker ISSUE 1.4

Similar documents
SimplePAT. Battery Powered Portable Appliance Tester. User Manual Issue 1.0

SPRAYSHOP ANALIZER IMPORTANT : TO BE READ BEFORE USING THE HIGH VOLTAGE FUNCTION

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Incorrect installation may cause other oven components to fail.

Megohmmeter Test Probe

Seeker HL Source Transmitter. User s Guide

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

2011 Ocean Signal Ltd

The Participant will select one of the two Approval Categories (below) and submit the appropriate documentation.

6900-( )-( ) HIGH SPEED SANDWICH PRESS

Contents. 1.0 Introduction. 1.0 Introduction 1. Welcome to Toyota Fleet Management (TFM) 2.0 Vehicle servicing and repairs 2. 3.

Digital Torque Wrench

Instruction Manual for model CB1 Check Box

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

CHAPTER 2 HOW TO APPLY FOR ELECTRICITY

FAQs for the Draeger Interlock 7000

PerfectTilt RF Motorized Shutter User Manual

Operator Instructions for Tension Links

QMSC F9.3 SIV Registration Information Pack 31 May 2013 V1 Page 1 of 5

SafetyPAT Plus A B P/N:

INTERNATIONAL WARRANTY PROCEDURE. AUTOCLIMA S.p.A. PG-01-05

OPERATION & MAINTENANCE INSTRUCTIONS

freedom through lightweight solutions

Guideline for the Queensland Rally Vehicle Registration Scheme

Power Beam 20MCP Searchlight with 12 LED Area Light and Vehicle Jump Starter. Instruction Manual

User s Manual Rev 1.3 GME

Warranty Information

Operating instructions in the back. PD1420LP

5. Alignment and Adjustments

Rental Industry Safety Tester Safe Check 5s

TESTER SET SOCKET & VOLTAGE

Operating instructions in the back. PD1820LF

ACCURACY RELIABILITY SIMPLICITY

Welcome to Garber C O R P O R AT E O V E R V I E W

2 TONNE TROLLEY JACK

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 2 NOVEMBER 2009

CONTACT TACHOMETER User s ManUal CT6235B

Installation Guide Galvanic Isolator Gi50/32/S/SA - 120a Surge Current

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

CONTACTS RELAY TESTER 66249

ATLAS Wheel Balancer Electrical Flow Chart

VERSION 2017 V.1.0

Thermistor Thermometer MODEL NO

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Fiber Identifier. Fiber Identifier is a tool necessary for the maintenance of optical fibers, used

Operators Guide: RoboSign Stop/Go Traffic Control System

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

Temp-14 Single Input Thermistor Thermometer

ValveSentry USER S MANUAL REVISED 8/6/16 IMPORTANT! PLEASE READ CAREFULLY AND SAVE

INDUSTRIAL HAUL AGREEMENT

Appliance / Machine / Switchboard Safety

Hand Held Pull Tester Instruction Manual Order No

Operator s Manual Portable Wood Chip Moisture Tester ENGLISH

OPERATING INSTRUCTION

SUBMERSIBLE PUMP. Model No: HIPPO 2 OPERATING & MAINTENANCE INSTRUCTIONS

Fitting Instructions: Daytona 675 from VIN and Daytona 675 R from VIN A

GBC Polar A4 & A3 Laminators. Instruction Manual

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609

1100W PORTABLE GENERATOR

MEASUREMENT FOUNDATION. Operating manual Line laser level ADA CUBE 3D

Tube-Line Techno-Bale 980

04979, 04980, 04981, 04982, 04983, 04984, 39054, 39055, 39056, 39057, 39225, 81459,

EXCEL EXCEL EXCEL. User Manual. Excel Yoga XCEL

WS-9116U Wireless 433 MHz Temperature Station. Instruction Manual

BATTERY BOOSTERS / CHARGERS BC120N BC130N BC210N BC320E BC410E BC520N

Time Electronics Ins-Cal. Insulation Tester Calibration System. Technical Manual

Eazidraw Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

Instruction Manual. Single-Input Thermistor Thermometer (Model )

Single-Input Thermocouple. Thermometers Type J, K, T

YOUR STEP-BY-STEP GUIDE TO THE PERFECT INSTALLATION. Lighted Magnifying Mirrors

Baker PPX Power Packs

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Sensory Mirror INSTRUCTIONS FOR USE

MODEL AP/W HIGH VOLTAGE HOLIDAY DETECTOR (NEW PRODUCT RELEASE 2015)

OnCommand Troubleshooting Guide Hayward Industries

EC1 Pocket Conductivity Tester Instruction Manual

IMPORTANT FITTING INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS BEFORE FITTING YOUR TURBO. FAILING TO FOLLOW THEM COULD INVALIDATE THE WARRANTY.

TESTLINK COMPLIANCE WESTUSA. Remote Actuation Cable Set. Instruction Manual

Swift Group Warranty & Service

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

The Vehicle Identity Check (VIC) Scheme

THREE RANGE DS METERS Operation Instructions

OWNER S MANUAL inch (130 mm) Coaxial Loudspeakers. Thank you for choosing JL Audio loudspeakers for your automotive sound system.

12V POWER PACK WITH 230V/A.C. OUTPUT INVERTER INSTRUCTIONS

Car Park Label Scheme for Persons with Physical Disabilities

Team Aware Perception System using Stereo Vision and Radar

SMART MOTOR SENSOR (SMS)

POWER and ELECTRIC CIRCUITS

Sinergex. PureWatts Elite 150. User's Manual. Sinergex Technologies L.L.C. (USA) Website:

GENERATOR MODEL NO: FG2500 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0114

200 Series Flow Meters

Atlas ESR. User Guide. Capacitance and Equivalent Series Resistance Meter. Model ESR60 (Enhanced)

operating manual DL7 101 DIGITAL THERMOMETER

RIGrunner. for models 4004USB 4005 / 4005H 4008 / 4008H

OPERATING INSTRUCTION D. E. STEARNS MODEL 14/20 REGULATED ,000 VOLT HOLIDAY DETECTOR

3000 SERIES DRY-BLOCK HEAT SOURCE

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

Changing your vehicle

GRD502-B Flow Chart 02/05/09

Transcription:

MICROWAVE CHECKER User Manual Issue 1.4 F i rst Stop Safety 1 1 Glaisdale Road N o rthminster Business Park York YO26 6QT t : 01904 791050 f : 01904 780054 e: info@firststopsafety.co.uk w: www.firststopsafety.co.uk

SAFETY Please read this manual carefully to make yourself familiar with the capabilities and functions of the Microwave Checker before attempting to use it. 1. Never place the unit inside the microwave. 2. There are no user serviceable parts in this unit. Under no circumstances should the user attempt to open the unit. If opened, the warranty will be invalidated. 3. The Microwave Checker is guaranteed for one year from the date of purchase. Please keep your invoice as proof of purchase. 4. Should the unit require a service, repair or calibration, please return it to: First Stop Safety 11 Glaisdale Road Northminster Business Park York YO26 6QT Tel: 01904 791050 When returning the unit, please contact the Sales Department to advise us of its return. The owner will be advised of any costs prior to work commencing.

INTRODUCTION The Microwave Checker is an easy to use, accurate meter for checking leakage from Microwave Ovens. It can also be used for checking Radio Frequency emission levels from a variety of sources. Package includes: Microwave Checker with 9v PP3 battery fitted. User Manual 25 RF emission test labels. Features RF measurement range from 0.07 mw/cm 2 to 7.1 mw/cm 2. 10 LEDs to show level in this range. Easy to read red/amber/green indication. 50 mm spacer built into product. Simple push button operation. Power On indication. Battery Low indication. 25 RF emission tested labels included.

OPERATION LEAKAGE TEST 1. Place a large mug of cold water inside microwave. 2. Switch on for 2 minutes at full power. (If the microwave oven has a radiant heater for roasting or baking, then make sure that this is not turned on. Only use the microwave oven on microwave power). 3. Place Microwave Checker as shown below in each position for about 15 seconds and note maximum position. By touching the surface of the microwave, you will be at the correct distance (50mm) for the measurement. Move side to side Move side to side Move up and down Move up and down

Move in a circle around the glass window 4. If measurements are not complete, then replace mug of water with a fresh mug of cold water and switch on for another 2 minutes. 5. If illuminated LED is in green area then this is an acceptable level of leakage. 6. If illuminated LED is in amber area, then this indicates that the leakage is acceptable, but is above what a new microwave would give. We would advise you to consider replacing the microwave oven within a year. 7. If illuminated LED is in red area, do NOT use the microwave. Remove from service immediately. INTERLOCK TEST 1. When the microwave is working, open the door and check that the oven switches off. You can use the Microwave Checker to check for levels. 2. If the oven is switched off, then the interlock will be working. If both the Leakage Test and the Interlock Test have passed, then write out and apply a PASS label.

SPECIFICATION Range: 0.07 mw/sq cm to 7.1 mw/sq cm Accuracy: ± 3dB Frequency Range: 2.45GHz ± 50MHz Probe Direction: At front of checker as marked Distance to antennae from front end: 50mm ± 2mm Power Supply: 1 X 9V PP3 Battery

CARING FOR YOUR MICROWAVE CHECKER Annual calibration Your Microwave Checker tester is an accurate instrument and it is important to make sure that it is continuing to measure correctly. A faulty tester could fail to pick up any faults with electrical appliances and result in passing them. To prevent this and ensure the accuracy of your Microwave Checker, we recommend that calibration is carried out annually. We will send you an annual reminder by e-mail or letter. When you return the Microwave Checker to us we check it out thoroughly and: Calibrate it with traceability back to National Standards. We refurbish the unit and upgrade it if required. We issue a Calibration Certificate. Collection & Delivery Service We can arrange for the Microwave Checker to be collected for calibration and delivered back to you. The turnaround is 5 working days from receipt of the tester. All you have to do is to order on-line or send us a completed order form. Lifetime Warranty As long as your Microwave Checker is calibrated annually by First Stop Safety we provide a Lifetime Warranty. Should the Microwave Checker fail for any reason between annual calibrations please give us a call. We will repair it and ship it back to you free of charge. By calibrating your tester annually your Lifetime Warranty will cover your Microwave Checker for many years. Booking a calibration This couldn t be easier. You can request your calibration in a number of ways. Download a booking form from our website www.firststopsafety.co.uk Send us an e-mail to calibrations@firststopsafety.co.uk Ring us on 01904 529054

Remember: All you have to do is to send us the order. We will do everything else! Lifetime Warranty Conditions First Stop Safety have complete confidence in our Microwave testers enabling us to provide a Lifetime Warranty free of charge. To retain the validity of the Lifetime Warranty the unit must be returned to First Stop Safety annually for a recalibration Note: If the calibration is allowed to expire, the Lifetime Warranty is invalidated. We have a one month grace period with regards to your calibration date. This means that you have one calendar month after the calibration expiry date in which to book your tester in for calibration. The Lifetime Warranty covers the Microwave Checker unit only, not accessories. If your unit develops a fault we repair it free of charge as long as your units Lifetime Warranty has been maintained and your account is up to date. What is not covered by the Lifetime Warranty If the unit has been water damaged. If the unit has been physically damaged beyond fair wear and tear. Repairs if the unit has not been returned for annual calibration. The cost of the annual calibration.