Start-up instructions

Similar documents
Start-up instructions

Softstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions

RVS-AX Instruction Manual

Dimensions WxHxD [mm] Weight [kg]

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

SOLSTART Instruction Manual

RVS-DN Digital Reduced Voltage Motor Starter

DKG-114 MANUAL AND REMOTE START UNIT

Operating manual UPS - System

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Starting Torque Limiter Type TCI (Soft Start)

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

3RW Soft Starters. General data. 6/2 Siemens LV 1 N SIRIUS Soft Starters 01/2008. Siemens AG 2008


XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

Application example of a motor controlled by MCD100 and protected by a circuit breaker

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Design Guide. VLT Soft Start Controller MCD 100

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

For Operation in the Control Cabinet 3RW Soft Starters

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

User Manual Rittal PMC UPS 6kVA

Emotron DCM Control Unit

SSW03 Soft Starter APG2009.indd 69 5/26/09 8:55 AM

SECTION MOTOR CONTROL

M A N U A L. Field Current Controller F2.2

Application Description

RVS-DX Digital Reduced Voltage Motor Starter

Innovation in soft start technology HFE-2 USER MANUAL. MAN-HFE-002. Version 01

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Power Electronics. MINISTOP Motor Brake Relay BA 9034N

Calculation of the Cross-sectional Areas of Circuit Live Conductors

Braking Devices VB 230/ Assembly- and Commissioning Instructions

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

Technical Manual Electrical Power Supply System T4002

3RW Soft Starters. General data. 6/4 Siemens LV

IBC control. MicroMax MANUAL. With adjustable boost function and threshold value. Since Set of EMC-glands as an option

ACCESS Always replace the cover panel on the unit after gaining access to the electrical connections.

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Assembly- and Commissioning Instructions Braking Devices VB 230/

HPV 100 Hydraulic Elevator Soft-Starter Technical Manual

1 Safety instructions. 2 Device components. Blinds Management Motor control insert Universal AC 230 V ~ Art. No. 232 ME. Operating instructions

HIB Enclosed Inverter User Guide

Electronic Braking Systems

Variable speed application guidelines

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

3RW40/44 Catalog Supplement July sirius 3RW40 3RW44

2.7. IT system floor-standing distribution cabinet Series -IPS-F

HPS2DB Serial Softstarter Operation Manual

GTZ 25 / 40 / 55. TECHNICAL DATA General features. Category of use: AC51, AC53a

Kelly KDC Series/PM Motor Controller User s Manual

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

TECHNICAL DATA SHEET KVA UPS Systemss

Compact System NRGS 11-2 NRGS Original Installation Instructions English

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter

Solenoid interlock AZM 200 The non-contact interlock.

Technical Data Sheets

Low cost, internally bypassed non optimizing soft starter

INTER PLANT STANDARD STEEL INDUSTRY NO CORRESPONDING IS

J1000. Compact Inverter Series.

MCD 200 Series Soft Starters

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2008

APPLICATION GUIDE. Pure easiness for a wide range of applications ACS580 general purpose drives

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden

IGLOO IGLOO EASY INSTRUCTION MANUAL

J TS 7090 Thyristor power switch

Hydrovar and Packaged Hydrovar

GTZ 25 / 40 / 55. THREE-PHASE SOLID STATE RELAYS WITH LOGIC CONTROL Vdc / Vac PROFILE. TECHNICAL DATA General features

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

For Operation in the Control Cabinet

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

L300P Inverter Specifications

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

ABB Softstarter Benefits Charnchanok Thongprad

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT

Braking Devices BR 230/ Assembly- and Commissioning Instructions

Technical specifications

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

ASYNCHRONOUS MOTORS THREE-PHASE MOTORS SINGLE-PHASE MOTORS BRAKE MOTORS INSTRUCCIONES DE SERVICIO OPERATING INSTRUCTIONS 2016

AC drive has detected too high a Check loading

Technical Data Sheets

SDS Enclosed Star-Delta Starter User Guide

Kelly KDHA High Voltage Series/PM Motor Controller User s Manual

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

Power Electronics. Motor brake relay GA 9031 ministop

Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Devices Supported: KEB48220 KEB48221 KEB48300 KEB48301 KEB48400 KEB48401 KEB48600 KEB48601 KEB72330 EB KEB72450 KEB EB KEB72600 KEB

USERS MANUAL MCD REMOTE OPERATOR

1.1. Reduced Voltage Motor Starters

Combined Motor Start and Braking Device VBMS... Assembly- and Commissioning Instructions

Transcription:

E l e k t r o n i k s y s t e m e G m b H Development and production of electronical systems Eichelreuth 13 Phone: +49 8641 598360 83224 Grassau Fax: +49 8641 598364 E-Mail: info@rs-steiner.com Internet: http://www.rs-steiner.com Start-up instructions Electronic soft-starter Type: Picostart Contents Page 1. General information............................................2 2. Installation of the soft-starter Picostart..............................2 3. Wiring diagram................................................3 4. Operation....................................................4 5. Progress of ramp-up and ramp-down process with a Picostart...........4 6. Survey of the individual types.....................................5 7. Diagnostic diagram.............................................6 8. Technical data.................................................7 Version: 2016/05/11 1

1. General information The electronic motor control devices Picostart... were developed for smooth and gentle start-up and running of three-phase squirrel-cage induction motors. When those motors are switched-on a high torque is produced which tends to damage the mechanical parts of the motor as well as the v-belt and the gearbox. Picostart soft-starters make use of a phase angle control to achieve a smooth start of your motor. Ramp-up and ramp-down time as well as ramp-up and ramp-down torque can be adjusted independantly so that the devices can be adapted to numerous use cases. The electronic starting device Picostart... is composed of modules. It is assembled with two basic components: power element with cooling system and thyristor switching facility control unit with electronic starting and control system 2. Installation of the soft-starter Picostart To begin with, all electrical connections are to be made according to the accompanying wiring diagrams: L1, L2, L3, T1 (U), T2 (V), T3 (W). The electronic smooth-starting devices must be connected to the power supply in accord with VDE specifications so that they can be disconnected from the mains using a suitable switching means (i. e., master switch, contactor, protective power switch). Conduit installation: The mains power supply and motor power supply, as well as the control wiring, have to be in separate ducts or conduits. In order to avoid malfunctions it is advisable to install the electronic signal wiring separate from the power supply and/or protective control wiring and either to twist the feed and return signal lines or use shielded control lines. On account of the internal wiring the neutral conductor mustn t be connected when the load is at operation. Please ensure that the clamps 3-4 are either connected to the PTC of the motor or that they are bridged (factory setting). It is essential for the electric installation to comply to the stipulations of the VDE (German Electrical Engineers Association), specifically to VDE 0100, VDE0113, VDE 160. 2

RS Elektroniksysteme GmbH - Electronic soft-starter Picostart 3. Wiring diagram external failure report * Picostart 11 3

4. Operation When putting the device into operation you have to ensure that the Picostart device isn t overloaded by many ramp-ups within a short period of time or by too high starting currents. Therefore the current of the different phases should be monitored and appropriate intervals between the ramp-ups should be scheduled as well. Check that the device is connected properly - if questions should arise concerning this point consult the wiring diagram (p. 3). If the supply voltage is available, LED B will light. In order to initiate ramp-up, the start contacts (1-2) have to be bridged. If Start is active, LED S1 lights at the beginning. If motor voltage has reached 100%, LED S2 lights. Depending on the adjustment of the potis t up and M up different ramp-up characteristics can be achieved. Deactivating the starting contacts will cause the ramp-down process to begin. LED S2 dies out soon afterwards. If motor voltage has decreased to 0%, LED S1 also dies out. Concerning the ramp-down process potis t down and M down are responsible (only frame sizes B, C). In case of temperature exceedance of the heat sink, incorrect phase direction or indications of the motor thermistor the power unit will be switched off and the electronic will be locked. At the same time LED St will light if a failure has been registered. Additionally, if the rotary field doesn t fit, LED Ph will light as well. Moreover, the device will switch off if phase failure is reported (because of the internal voltage supply) and LEDs Ph and St flash. Optionally, the failure can be indicated by relay contacts (clamps 5, 6, 7). After the failure has been removed the Picostart must be reseted by deactivating the start contacts. Bridging them once again initiates a new ramp-up. Frame size A doesn t possess any failure indication or contacts in case of phase failure or incorrect phase direction. 5. Progress of ramp-up and ramp-down process with a Picostart 4

RS Elektroniksysteme GmbH - Electronic soft-starter Picostart 6. Survey of the individual types Type Motor power [kw] Max. starting current [A] Rec. semiconductor fuse [A] Mains fuse [A] Rec. crosssection [mm 2 ] Weight [kg] Frame size Dimensions WxHxD [mm] option: malfunction report contact Picostart 0,55 0,55 5 8 16 1,5 0,3 A 45x75x110 - Picostart 0,75 0,75 8 8 16 1,5 0,3 A 45x75x110 - Picostart 1,5 1,5 10 15 25 2,5 0,3 A 45x75x110 - Picostart 2,2 2,2 15 20 25 2,5 0,3 A 45x75x110 - Picostart 3,0 3,0 18 25 25 2,5 0,3 A 45x75x110 - Picostart 4,0 4,0 24 30 25 2,5 0,4 B 70x75x110 x Picostart 5,5 5,5 30 35 25 2,5 0,4 B 70x75x110 x Picostart 7,5 7,5 45 40 25 4,0 0,8 C 100x100x110 x Picostart 11.0 11,0 60 40 32 4,0 0,8 C 100x100x110 x Errors and technical modifications excepted (Date: 2008/08) 5

7. Diagnostic diagram Fault Possible reason Solution no supply voltage phase failure fault output locks mains contactor no LED lights centralized alarm indicates fault LED B and S1 light LED St and Ph are flashing centralized alarm indicates fault LED St is flashing motor doesn t start immediate start of motor with decreased power after supply voltage is connected on activation of Start ramp-up is performed within the defined time immediate start of motor with decreased power after supply voltage is connected Start command has no influence on motor current LED B lights LED S1, S2 light motor hums, but doesn t start within ram-up time failure of one phase or wrong rotary field bridge or PTC-sensor on ter. 3-4 is not available temperature exceedance of motor star-wired motor and neutral point is connected with N incorrect wiring defect semiconductor incorrect wiring defect semiconductor device doesn t fit for the motor power or motor isn t intented for soft-start check connections of mains voltage remove fault relay output so that mains contactor switches again check wires and fuses of the installation bridge ter. 3-4 check for temperature exceedance and restart check PTC and wires for malfunction remove N from neutral point check wires device needs to be repaired check wires devices needs to be repaired check motor data, contact your reseller 6

8. Technical data Control voltage 110-440V AC +- 20 % Frequency 50-60Hz +- 10 % (mains or control voltage) Rotary field self-synchronizing Number of controlled phases L1, L2, L3 (W3C-circuit) Start-up cycles max. 30/h at medium load Ambient temperature -20 C-45C Storage temperature -25 C-75 C Relative humidity 95% (non-condensing) Max. altitude 1000m Kind of protection IP 40 LED-indications ready for operation, Start, 100% U motor Suitable motor powers 0,55-11kW (cf. table Survey of the individual types, p. 5) Failure indication temperature exceedance of device PTC-input phase failure (only B and C devices) Standards of use AC-53a according to IEC Mounting position vertical, electronic connections below Centralized alarm (optional) 250V AC, 5A (frame sizes B, C) CE-regulations EMC Directive 2014/30/EU LVD 2014/35/EU Errors and technical modifications excepted (Date: 2016/05) 7