3VF3 to 3VF8 Circuit-Breakers

Similar documents
3VU13, 3VU16 Circuit-Breakers

Air Circuit Breakers

Motor Starter Protectors

Air Circuit Breakers

SENTRON Switching and Protection Devices Molded Case Circuit Breakers

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Motor Starter Protectors

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Order No. of the options EMC filter Class A

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

3VT Kompaktleistungsschalter bis 630A

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0

SENTRON VL Series Product Specifications

3 - Protection components Motor circuit-breakers

Low breaking capacity moulded case circuit breakers

3NP1 Fuse Switch Disconnectors up to 630 A

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

SIRIUS 3RU2 Thermal Overload Relays

3VT1 Molded Case Circuit Breakers up to 160 A

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Protection Equipment

Protection Equipment. 5/2 Introduction

Stars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

SENTRON 3WL5 Air Circuit Breakers/ Non-Automatic Air Circuit Breakers according to UL 489/IEC

SENTRON Switching and Protection Devices Switch Disconnectors

Siemens switchgear. Tried, tested, trusted. Circuit Breakers

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Manual Motor Starters. Meta-MEC

Motor Circuit Breakers C3

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10

Motor Circuit Breakers C4

SWITCH FUSES 3KL71 from 32A to 800A Description

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

DEVICE STATE/BYPASSED FAILURE OVERLOAD

3RT14 Contactors with 3 Main Contacts

Molded Case Circuit Breakers H series General information

Low-Voltage Controls and Distribution

3VT2 Molded Case Circuit Breakers up to 250 A

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

VD4/R. Medium Voltage vacuum circuit-breakers for secondary distribution

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A

Catalog LV 1 Add-On October sentron CIRCUIT-BREAKERS. 3VL Molded Case Circuit-Breakers approved according to UL 489 up to 1600 A

Type MS450 MS497. Phone: Fax: Web: - Manual motor protectors

DATA SHEET 3VT3 MCCB ACCESSORIES

General. Principles. 3-Trapped Key Switches. 11-Cat. No. Index. Logic. Power. Safety Switches Trapped Key Switches Overview

cor Long Run Experience

Electronic Circuit Breaker ESS20

Combination Starters. SIRIUS 3RA11 Non-Reversing Combination Starters,

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Protection components

System pro M compact Miniature Circuit Br eakers Description Features

Components for EEx e Panels

BETA Fuses and Fuse Systems

SIRIUS Configuration

Wall mounted switchgear

For Operation in the Control Cabinet

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

Electronic Circuit Breaker ESS20-0..

Miniature circuit breakers

SENTRON 3VT Molded Case Circuit Breakers up to 1600 A

BETA Switching Switches and Light Indicators

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

D509E. Manual Motor - Starters

max pole for t=15 ms

MOULDED CASE CIRCUIT BREAKERS BC160N

General data 5/37. Overview

Vacuum Circuit-Breaker Modules

Miniature Circuit-Breakers (MCBs)

Control Circuit Protection

Overcurrent releases - description, specifications, characteristics specifications specifications description...

Medium voltage products HD4/R MV gas circuit-breakers for secondary distribution. Power and productivity for a better world TM

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Low voltage circuit breakers

Protective Devices: Circuit-Breakers 1 )

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

SIRIUS Shortform Catalogue 2017 siemens.com/sirius

C1251N DC and C1251N 1000 V

DMX 3 -I 2500 switch disconnectors

WORKSHOP SPECIFICATIONS

Jtec 10kA Miniature Circuit Breaker

Thermal-Magnetic For Mining Applications Class 600

SENTRON Switching and Protection Devices Air Circuit Breakers

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Siemens AG WT Air Circuit Breakers up to 4000 A. Catalog LV SENTRON. Answers for infrastructure.

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

SIRIUS Innovations. Technical information for ring terminals SIRIUS. Answers for industry.

Short form catalogue Motor protection and control Manual motor starters

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

PKZ and PKE motor-protective circuit-breakers

Circuit breakers. Panorama. PB111746_30.eps PB111749_30.eps

Thermal-magnetic Miniature Circuit Breaker 4230-T...

MC FRAME SIZE 1 / UP TO 160A

DPX 630 Electronic release

Transcription:

3VF3 to 3VF8 Circuit-Breakers Accessories Operating mechanisms For other s for 3VF3 with knob Rotary drive, complete, scope of supply Cubicle door for 3VF6 Motor operating mechanism for 3VF3 Motor operating mechanism for 3VF4, 3VF5, 3VF6 (shown with 3VF6) Motor operating mechanism for 3VF8 Accessories for 3VF3 Accessories for 3VF4 Order No. Price Order No. Price 3- or 4-pole for direct fitting to the. Degree of protection IP 30, black lockable with max. 3 padlocks, without leading aux. switch 3VF9 3231AA00 3VF9 4231AA00 with leading aux. switch acc. to ON*) (2 NO), 3VF9 3231AB00 3VF9 4231AB00 EMERGENCY STOP version red knob, yellow indicator plate without leading aux. switch 3VF9 3231BA00 3VF9 4231BA00 with leading aux. switch acc. to ON*) (2 NO), 3VF9 3231BB00 3VF9 4231BB00 Version with shaft stub, without knob (Rotary drive with door coupling required in addition, see Part 13) without leading aux. switch 3VF9 3231JA00 3VF9 4231JA00 with leading aux. switch acc. to ON*) (2 NO), 3VF9 3231JB00 3VF9 4231JB00 Rotary drive, complete for fitting in doors and covers Degree of protection IP 65, totally insulated, including black knob with aluminized masking plate indicator plate, detachable door coupling, 300 mm 2 ) extension shaft and front rotary drive for the corresponding, lockable with a maximum of 3 padlocks, with door interlock without leading aux. switch 3VF9 3231EA00 3VF9 4231EA00 with leading aux. switch acc. to ON*) (2 NO), 3VF9 3231EB00 3VF9 4231EB00 EMERGENCY STOP version red knob, yellow indicator plate without leading aux. switch 3VF9 3231FA00 3VF9 4231FA00 with leading aux. switch acc. to ON*) (2 NO), 3VF9 3231FB00 3VF9 4231FB00 Additional locking device 3VF9 3231VA00 3VF9 4231VA00 for rotary drive, complete 1 ) Motorized operating mechanism 3 ) Degree of protection IP 00 without locking device AC 50/60 Hz DC 24 V 3VF9 3231MA20 3VF9 4231MA20 42 V 48 V 3VF9 3231MB10 3VF9 4231MB10 60 V 3VF9 3231MC20 3VF9 4231MC20 110/127 V 110/127 V 3VF9 3231MD10 3VF9 4231MD10 220/240 V 220 V 3VF9 3231ME10 3VF9 4231ME10 with locking device for 3 padlocks AC 50/60 Hz DC 24 V 3VF9 3231NA20 3VF9 4231NA20 48 V 42 V 48 V 3VF9 3231NB10 3VF9 4231NB10 60 V 3VF9 3231NC20 3VF9 4231NC20 110/125 V 110/127 V 110/127 V 3VF9 3231ND10 3VF9 4231ND10 220/240 V 220 V 3VF9 3231NE10 3VF9 4231NE10 Motorized operating mechanism suitable for synchronizing Degree of protection IP 00 with locking device for 3 padlocks AC 50/60 Hz DC 24 V 3VF9 4231QA20 48 V 42 V 48 V 3VF9 4231QB10 60 V 3VF9 4231QC20 110/127 V 110/127 V 3VF9 4231QD10 220/240 V 220 V 3VF9 4231QE10 Handle for motor operating mechanism 3VF9 6231WB00 suitable for synchronizing 5 ) Solenoid drive 110/120 V AC 50/60 Hz 3VF9 3231SD30 220/240 V AC 50/60 Hz 3VF9 3231SE30 110/120 V DC 3VF9 3231SD20 220/240 V DC 3VF9 3231SE20 *) Leading auxiliary switch for OFF or ON/OFF,. HS = auxiliary switch 1) Only required if the is also to be lockable with the door open, i.e. with rotary drive disconnected. Lockable with max. 3 padlocks, 4.5 to 8 mm hasp diameter. 2) For longer shafts, see Part13. 11/20 Siemens NS K 2000

For other s 3VF3 to 3VF8 Circuit-Breakers Accessories Operating mechanisms Accessories for 3VF5 Accessories for 3VF6 Accessories for 3VF7 Accessories for 3VF8 Order No. Price Order No. Price Order No. Price Order No. Price 3VF9 5231AA00 3VF9 6231AA00 3VF9 7231AA00 3VF9 8231AA01 3VF9 5231AB00 3VF9 6231AB00 3VF9 7231AB00 3VF9 8231AB01 3VF9 5231BA00 3VF9 6231BA00 3VF9 7231BA00 3VF9 8231BA01 3VF9 5231BB00 3VF9 6231BB00 3VF9 7231BB00 3VF9 8231BB01 3VF9 5231JA00 3VF9 6231JA00 3VF9 7231JA00 3VF9 8231JA01 3VF9 5231JB00 3VF9 6231JB00 3VF9 7231JB00 3VF9 8231JB01 3VF9 5231EA00 3VF9 6231EA00 3VF9 7231EA00 3VF9 8231EA01 3VF9 5231EB00 3VF9 6231EB00 3VF9 7231EB00 3VF9 8231EB01 3VF9 5231FA00 3VF9 6231FA00 3VF9 7231FA00 3VF9 8231FA01 3VF9 5231FB00 3VF9 6231FB00 3VF9 7231FB00 3VF9 8231FB01 3VF9 5231VA00 3VF9 6231VA00 integral with front rotary drive integral with front rotary drive 3VF9 5231MA20 6 ) 3VF9 6231MA20 3VF9 5231MB10 6 ) 3VF9 6231MB10 3VF9 5231MC20 6 ) 3VF9 6231MC20 3VF9 5231MD10 6 ) 3VF9 6231MD10 3VF9 5231ME10 6 ) 3VF9 6231ME10 3VF9 5231NA20 6 ) 3VF9 6231NA20 6 ) 3VF9 7231NB20 3VF9 8331NB20 3VF9 5231NB10 6 ) 3VF9 6231NB10 3VF9 5231NC20 6 ) 3VF9 6231NC20 6 ) 3VF9 7231ND20 3VF9 5231ND10 6 ) 3VF9 6231ND10 4 ) 6 ) 3VF9 7231ND30 4 ) 3VF9 8331ND30 3VF9 5231NE10 6 ) 3VF9 6231NE10 4 ) 6 ) 3VF9 7231NE30 4 ) 3VF9 8331NE30 3VF9 5231QA20 3VF9 6231QA20 3VF9 5231QB10 3VF9 6231QB10 3VF9 5231QC20 3VF9 6231QC20 3VF9 5231QD10 3VF9 6231QD10 3VF9 5231QE10 3VF9 6231QE10 3VF9 6231WB00 3VF9 6231WB00 3) A transformer is required for 380/400 V or 500 V control supply: e.g. 400/230 V (380/220 V), Order No. 4AM34 415AT100C Catalog Part 14. z.b. 500/230 V (380/220 V), Order No. 4AM34 415FT100C The motor operating mechanism must be ordered for 50/60 Hz 220 V AC. Siemens NS K 2000 4) Not for DC voltages. 5) For local manual operation. 6) Do not use motor operating mechanisms in combination with withdrawable frames in the case of 3VF6/3VF7 11/21

3VF3 to 3VF8 Circuit-Breakers Accessories Connections For other s 3VF9 5241VA50 Auxiliary connection plug for 3VF4/3VF5 NSK-8224 l NSK-8225 3VF9 7241LD10 Rear connection for 3VF7 3VF9 6241AD10 Multiple feed terminal for 3VF6 3VF9 5241NB10 Terminal cover for 3VF5 Fitted to rear of circuitbreaker Mounting piece on plug-in socket 3VF9 6241GB10 Withdrawable frame with 3VF6 plug-in 3VF9 3241LD10 rear terminal for 3VF3 3VF9 5241FA10 plug-in socket with base plate for front connection for 3VF5 3VF9 7241JA10 Front busbar connection pieces for 3VF7 3VF9 5241RA10 Interphase barrier for 3VF4/3VF5 Accessories for 3VF3 Accessories for 3VF4 Order No. Price Order No. Price 3- or 4-pole Auxiliary connection plug for plug-in / withdrawable fitted to side of plug-in CB 3 ) 3VF9 6241VA40 3VF9 6241VA40 fitted to rear of CB 3VF9 5241VA50 additional side plug 3 ) 3VF9 6241VJ40 3VF9 6241VJ40 additional rear plug 3VF9 6241VJ50 Pull-out device 1 ) 3VF9 6241VF00 3VF9 6241VF00 for plug-in circuit breaker/ plug-in socket Position indicator switch for withdrawable frame 3-pole only Front busbar 3VF9 3241JA10 3VF9 4241JA10 connection pieces 1 set = 3 items Rear connections 3VF9 3241LD10 3VF9 4241LD10 1 set = 3 items Terminal with interphase barrier with standard terminals, Standard terminals, for flexible flat copper bars for up to 160 A, included in scope of (20 mm wide, up to 10 mm thick) included in scope of supply of 1 set = 3 items supply of Multiple feed terminals 1 set = 3 items complete with baseplate and 2 terminal covers for front connection 3VF9 3241FA10 3VF9 4241FA10 for CB with DI module 3VF9 3241FE10 3VF9 4241FE10 with baseplate for rear connection 3VF9 3241FB10 3VF9 4241FB10 for CB with DI module 3VF9 3241FF10 3VF9 4241FF10 Withdrawable frame 2 ) with baseplate and crank handle for front connection for rear connection Terminal covers IP 30 3VF9 3241NB10 3VF9 4241NB10 with integral interphase barriers for cable connection for cable connection 1 set = 2 items Interphase barriers 3VF9 3241RA10 3VF9 5241RA10 1 set = 2 items 4-pole only Front busbar 3VF9 3241JA20 3VF9 4241JA20 connection pieces 1 set = 4 items Rear connection 3VF9 3241LD20 3VF9 4241LD20 1 set = 4 items Terminal with interphase barrier with standard terminals, Standard terminals, for flexible flat copper bars for up to 160 A, included in scope of up to 1 10 20 mm included in scope of supply of 1 set = 4 items supply of Multiple feed terminal 1 set = 4 items complete with baseplate and 2 terminal covers for front connection 3VF9 3241FA20 3VF9 4241FA20 for CB with DI module 3VF9 3241FE20 3VF9 4241FE20 with baseplate for rear connection 3VF9 3241FB20 3VF9 4241FB20 for CB with DI module 3VF9 3241FF20 3VF9 4241FF20 Withdrawable frame 2 ) with baseplate and crank handle for front connection for rear connection Terminal covers IP 30 3VF9 3241NB20 3VF9 4241NB20 with integral interphase barriers for cable connection for cable connection 1 set = 2 items For 8US1 busbar adapter system, see Part 13. 1) For easy removal of 3VF s when mounted in a row. 2) Use plug-in with connection cables (see page 11/14). 3) Not in conjunction with withdrawable frames. 11/22 Siemens NS K 2000

For other s 3VF3 to 3VF8 Circuit-Breakers Accessories Connections Accessories for 3VF5 Accessories for 3VF6 Accessories for 3VF7 Accessories for 3VF8 Order No. Price Order No. Price Order No. Price Order No. Price 3VF9 6241VA40 3VF9 6241VA40 3VF9 5241VA50 3VF9 6241VA50 3VF9 7241VA50 3VF9 6241VJ40 3VF9 6241VJ40 3VF9 6241VJ50 3VF9 6241VJ50 3VF9 6241VJ50 3VF9 6241VF00 3VF9 6241VF00 3VF9 6241VL60 3VF9 7241VL60 (1 changeover) (2 changeovers) 3VF9 5241JA10 included in scope of 3VF9 7241JA10 3VF9 8241JA10 supply of the (up to 2000 A) 3VF9 5241LD10 3VF9 6241LD10 3VF9 7241LD10 3VF9 8241LD10 3VF9 5241JB10 on request on request 3VF9 6241AD10 3VF9 7241AD10 (up to 630 A) 3VF9 5241FA10 3VF9 6241FA10 3VF9 5241FE10 3VF9 5241FB10 3VF9 6241FB10 3VF9 5241FF10 4 ) 3VF9 6241GA10 4 ) 3VF9 6241GB10 4 ) 3VF9 7241GA10 4 ) 3VF9 7241GB10 3VF9 5241NB10 3VF9 6241NB10 for cable connection for cable or busbar connection 3VF9 5241RA10 3VF9 6241RA10 3VF9 7241RA10 3VF9 5241JA20 included in scope of 3VF9 7241JA20 3VF9 8241JA20 supply of the (up to 2000 A) 3VF9 5241LD20 3VF9 6241LD20 3VF9 7241LD20 3VF9 8241LD20 3VF9 5241JB20 on request on request 3VF9 6241AD20 3VF9 7241AD20 (up to 630 A) 3VF9 5241FA20 3VF9 6241FA20 3VF9 5241FE20 3VF9 5241FB20 3VF9 6241FB20 3VF9 5241FF20 4 ) 3VF9 6241GA20 4 ) 3VF9 6241GB20 4 ) 3VF9 7241GA20 4 ) 3VF9 7241GB20 3VF9 5241NB20 3VF9 6241NB20 for cable connection for cable or busbar connection 4) The withdrawable frame cannot be used in combination with the motor operating mechanism for 3VF6 and 3VF7. Siemens NS K 2000 11/23

3VF3 to 3VF8 Circuit-Breakers Accessories locking devices, covers For other s 3VF9 5201AA00 Cover frame for door cutout for 3VF5 3VF9 3231VG00 Module for cross-interlocking of toggle levers for 3VF3 3VF9 5231VC00 Locking device for toggle lever for 3VF4/3VF5 3VF9 6231VB00 Toggle lever extension for 3VF6 3VF9 5231VL00 Cross-interlocking of two s with rotary drive, for 3VF3 to 3VF7, complete for fitting in doors and covers Accessories for 3VF3 Accessories for 3VF4 Order No. Price Order No. Price 3 or 4-pole Locking device 3VF9 3231VC00 3VF9 5231VC00 for toggle lever Toggle lever extension 3VF9 5231VB00 for retro-fitting by pushing onto the toggle lever of the Cross-interlocking of two 3VF9 5231VL00 3VF9 5231VL00 s order 2 rotary door coupling drives with this device 1 ) Cover frame for door cutout IP 30 for without DI module 3VF9 3201AA00 3VF9 4201AA00 with DI module 3VF9 3201AB00 3VF9 4201AB00 Sheet steel enclosure IP 54 without drive (see Part 13 for insulated enclosure) 3VF9 3241DA00 Accessories: with shaft stub, without knob see page 11/20. Also required: black knob, lockable 3VF9 3231VN10 red knob, with yellow plate, 3VF9 3231VN20 lockable, for EMERGENCY STOP circuit breaker Insulated enclosure see Part 13. 3-pole only Module for cross-interlocking of 3VF9 3231VG00 3VF9 4231VG00 toggle levers 2 ) (this is not a changeover device) 3VF circuit breakers with DI (differential current) module Application Safety of persons in TT, IT and TN systems (set to I n = 30 ma, t d instantaneous 3 ) Protection of plant and equipment against overload or damage by earth faults (earth fault protection). The DI module detects earth fault currents in 3- and 4-wire systems (AC or pulsating DC) and causes the to switch off the faulty circuit. Equipping a 3VF with a DI- module has no effect on the characteristics of the : Rated voltage (50/60 Hz), rated current, switching capacity electrical and mechanical life connections drive mechanisms auxiliary switches and releases see page 11/25. Specifications Circuit-breakers with DI modules comply with IEC 60 947-2 and DIN VDE 0660 Part 101, the differential current protection complies with IEC 60 947-2, Appendix B. Electromagnetic compatibility (EMC) complies with IEC 60 801-2 to 5. Method of operation In a fault-free system, the sum of the conductor currents in the current transformer of the DI module is equal to zero. If a fault current flows to ground due to an insulation fault in the part of the system being protected, a differential current results. This produces a voltage 3VF5 with DI module in the secondary winding of the current transformer. The induced voltage is evaluated electronically and a trip signal is given to the DI release in the if the trip conditions are fulfilled. Tripping characteristic of a DI module Break-time 100 s 50 20 10 5 2 1 0,5 0,2 0,1 0,05 0,02 0,01 0,005 ANSK-5720c 1,0s 0,5s 0,25s 0.1s 0,06s 0,5 1 1,5 2 3 4 5 10 x n Current t d instantaneous Footnotes to pages 11/24 and 11/25: 1) See page 11/20. 2) Only possible for versions with connection cables. 3) IEC specifications (not DIN VDE 0100 Part 410). 4) Not for electronic release (11th position of Order No. 5 or 6 ). 11/24 Siemens NS K 2000

For other s 3VF3 to 3VF8 Circuit-Breakers Accessories locking devices, covers Accessories for 3VF5 Accessories for 3VF6 Accessories for 3VF7 Accessories for 3VF8 Order No. Price Order No. Price Order No. Price Order No. Price 3VF9 5231VC00 3VF9 6231VC00 3VF9 7231VC00 3VF9 5231VB00 3VF9 6231VB00 included in scope of included in scope of supply of the supply of the 3VF9 5231VL00 3VF9 6231VL00 3VF9 6231VL00 3VF9 5201AA00 3VF9 6201AA00 3VF9 7201AA00 3VF9 8201AA00 3VF9 5201AB00 For insulated enclosure see Part 13 For insulated enclosure see Part 13 For insulated enclosure see Part 13 3VF9 5231VG00 3VF9 6231VG00 Settings The differential tripping current I n is adjustable in steps from 30 ma to 30 A. The trip delay can be set from instantaneous to 1 sec in steps. Exception: with setting I n = 30 ma, tripping is instantaneous. The setting knob can be sealed to prevent unauthorized access. The control panel incorporated a test button to electronically test the function of the current transformers, the evaluation electronics and the DI release in the. The DI module detects 1, 2, 3 or 4-pole loads with its integral summation current transformer. Indication/ shunt release A visual indicator in the circuitbreaker cover and an auxiliary switch for remote monitoring indicates whether the circuitbreaker has been tripped by the DI release. The DI release can also be used as a shunt release for remote tripping of the. The and DI module combination is fed from the top. 3VF s (3- and 4-pole) with DI module are available with auxiliary and alarm switches. (2nd order No. supplement, see pages 11/14 and 11/15). Circuit breakers with DI modules cannot be supplied with undervoltage releases or additional shunt release (1st Order No. supplement: 0A, see pages 11/14 and 11/15). 3VF circuit breakers with DI module The DI module is fitted to the at the factory. When ordering, add Order No. suffix Z to the complete Order No. and add the relevant Order Code. For 3- and 4-pole s A Rated current I n of circuitbreaker Adjustabledifferential current I N Adjustable delay time t d A s V Rated operating voltage U e Order No. with Z 3VF.....0A..Z and additional Order Code @@@ Code for other versions Z Extra price for Order Code A01 Selection and ordering data Extra price for Order Code A02 3-pole 4-pole 3-pole 4-pole 3-pole kg Extra weight of 3VF31 For line or 100 0.03 instantaneous 110415 A01 0.48 0.5 3VF32 motor protection 160 0.1 0.3 0.06 110690 A02 0.48 0.5 3VF4 250 0.5 1.0 0.1 0.25 0.94 1.25 3VF5 For line protection 4 ) 400 4 ) 3.0 10 30 0.5 1.0 1.18 1.21 4-pole kg Siemens NS K 2000 11/25