Stabinger Viscometer Series. SVM Series

Similar documents
Stabinger Viscometer SVM 3001

SVM Stabinger Viscometer. ::: Viscometry at its best

Viscometry Rheometry. The Range. ::: Intelligence in Rheometry

Callisto 100. Cold Filter Plugging Point Tester

Measuring Systems for Quality Control in Biodiesel Production. ::: Great People Great Instruments

ADU 5. Automatic Distillation Unit

AKVdiesel. Automated kinematic Viscometer key features. Fully complies with ASTM D445. Two measuring positions. Remove cap and pour in sample

Instruments for Chemical and Petroleum Products. Flash Point

Detailed Mid-FTIR Analysis Of Gasoline, Diesel & Jet Fuel With A Single Portable Analyzer In Seconds

Instruments for the Analysis of Petroleum Products. Oxidation Stability

PMA 5. Pensky-Martens Flash Point Tester. ::: Volatility... Flammability

Q200. Aquamax FlashPoint. Q5800 MiniLab 53 MiniLab 153 MicroLab Q1000. Q100 Spectroil M. Q300/310 Q3000 Pat 940 Density 5

TSHR 6000 series TN/TS/TX analyzer

ERAVAP NEW! VAPOR PRESSURE TESTING AT ITS BEST. One Vapor Pressure Tester for All Applications:

Oil Comparison for Weighing Precipitation Gauges as used in Environment Canada

economics and performance Spark Holland introduces OPTIMAS The optimum balance of BETTER SAMPLE CARE

D-2 Incorporated. JF-1A-RC RampCheck Product Brochure. Part Number: JF-1A-RC Revision Date: 09/11/15 Drawing Number: R6

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors

A unique density, viscosity sensor. High technology brick. Field oriented. For light & medium petroleum products. Related norms

ERAFLASH NEW! THE SAFE SIDE OF FLASHPOINT TESTING. One Flashpoint Tester for All Applications:

Spark Holland introduces ALIAS for ÄKTA pure All-round, state-of-the-art

Elemental Analysis Advanced

Low cost EDXRF elemental analyzer

TSHR 7000 series TN-TS-TX analyzer

TESIGNG OF FUELS: VISCOSITY OF LIQUID FUELS

Vapor Pressure Measurement Of Gasoline, Crude Oil & LPG With New ASTM D5191 & D5188 Speed Test

USV Ultra Shear Viscometer

MiniLab EL Series for High Performance Engine Development and Maintenance

Solution Sheet 1.

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010. ASTM INTERNATIONAL 100 Barr Harbor Drive West Conshohocken, PA Amy Meacock

Monitor Chlorine in Crude at Sub-ppm Levels

Agilent 7693A Automated Liquid Sampler

FORCE TENSIOMETER K20 THE STAND-ALONE TENSIOMETER FOR QUALITY CONTROL

HPLC SYSTEM S 500 SERIES

Petro Solutions. Analytical Instruments for the Petrochemical Industry

Process Analyzer. Viscosity Index Analyzer Model P-950. Credible Solutions for the Oil and Gas Industry

Autonomous Power Supply Uninterruptible Power Supply (UPS)

Agilent 7693A Automated Liquid Sampler

Exceeding Expectations

MB3000. Versatile FT-IR analyzer designed for your industry The most reliable FT-IR, the lowest cost of ownership.

The Advantage of Real Atmospheric Distillation using D7345 Test Method. Presented by Jonathan Cole, PAC

Sulfur in Oil Analyzer

Model Name: 4 Position RPV-1

S 1125 HPLC Pump System

testo 338 Portable Soot and Particulate Meter Versatile, digital display of particulates

White Paper.

DEPARTMENT OF CHEMICAL ENGINEERING University of Engineering & Technology, Lahore. Energy Engineering Lab

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Manual KREBS Viscometer PCE-RVI 5

AR2000ex Rheometer Standard Operating Procedures Revised: 5/1/2018

Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases. Drawing 1

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

Interface I-300 / I-300 Pro Technical data sheet

Flash Point Process Analyzer

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

DUCOM HIGH FREQUENCY RECIPROCATING RIG

MARINE APPROVED CEMS GREEN EFFICIENCY ON BOARD

ISO 2909 / ASTM D

breakthrough versatility

8000 Series Liquid Flow Meter

U tube viscometer. Kinematic viscosity bath RASAYAN

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Vertical Tensile Machine

Domino D-Series lasers Small things can make a big difference

Liquid Chromatography

FIRST FOR PORTABLE PARTICLE COUNTING

Why measure viscosity in-line?

NEW HPLC - SYSTEM LINE

Automated Precision Weighing

Domino D-Series lasers Small things can make a big difference

8000 Series Liquid Flow Meters

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

VISCOMETER TVB-10W. Model. responding swiftly to your needs

Fluke 500 Series Battery Analyzers

AVL CONTINUOUS FUEL BALANCE

REBCO (RUSSIAN EXPORT BLEND CRUDE OIL) SPECIFICATION GOST

Thermo Scientific Heraeus Primo and Primo R Centrifuges. Flexible and efficient, compact high-performance centrifuges

MGE TM Galaxy TM 7000 GFC

Safety drying oven with expended temperature range

Softening point by Ring & Ball. Density and relative density of liquids by Hubbart pycnometer

KEM SET. for Petrochemical

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

TYPE APPROVED CEMS GREEN EFFICIENCY ON BOARD

Crude Assay Report. Crude Oil sample marked. Barrow Crude Oil. On Behalf Of. Chevron Australia Pty Ltd. Laboratory Supervisor. Crude Assay Chemist

Varian, Inc. Vacuum Technologies. Rotary Vane Pumps. Features and Benefits 2-3. Typical Applications 4-5. Pump Models 6-19.

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

Determination of Volume Correction Factors for FAME and FAME / Mineral-diesel blends

Innovation in cold behavior

MiniLab EL Series for High Performance Engine Development and Maintenance

International Journal of Scientific & Engineering Research, Volume 6, Issue 11, November ISSN

Ceiba Crude (31.44 API, Sul WT%)

For the fastest possible service, you can now reach Koehler via the Internet. On our website, you can:

PICO Pµlse Contact Dispense Valve

Automatic Sampling/Quality Measurement Crude Oil. Crude Oil Quality Association San Antonio, TX March 7, 2013

IROX 2000 IROX DIESEL

Rotor No.3, No.4, No.5 No.1, No.2, No.3 Cup A, B No.3 Cup Extension Rod - 1 PC Batteries 4pcs, IEC R6 4pcs, IEC R6

Recirculating Coolers

HPLC System S 600 Series

CFPP Process Analyzer

Metrohm. 743 Rancimat. Determination of the oxidation stability of Oils and fats Biodiesel Food and cosmetics

Transcription:

Stabinger Viscometer Series SVM Series

Welcome to New Viscometry This is Wilhelm. He s a little old-fashioned and doesn t like change. That s why he used glass capillaries to measure viscosity up until recently. Although he was skeptical, Wilhelm allowed a young colleague to show him the new SVM viscometer from Anton Paar. He was really surprised by how fast and easy SVM delivers a number of important parameters at once. As Wilhelm is smart, he immediately recognized the great potential of this new approach. He got one of these viscometers for his own work and is now overjoyed at how easy it is to operate. Without his new SVM, Wilhelm would have to sit for hours in front of his capillaries waiting and waiting. But not anymore. A new world has opened up for him: the world of New Viscometry. Enjoy the whole story here/on:

SVM TM gives you more parameters than any other kinematic viscometer on the market. So you can expect more.

Expect more Measuring viscosity with an SVM is easy, fast and accurate. Measuring principle The highly precise Stabinger Viscometers are based on the Couette measuring principle and have an integrated density measuring cell. The small viscosity measuring cell contains a tube which rotates at a constant speed and is filled with sample fluid. A measuring rotor with a built-in magnet floats freely in the sample. The sample s shear forces drive the rotor while magnetic effects retard its rotation. Shortly after the measurement start, the rotor reaches equilibrium speed. This speed is a measure of the fluid s viscosity. The kinematic viscosity is automatically calculated from the dynamic viscosity and density of the sample.

Your benefits at a glance - Multiple parameters from just one syringe - Low sample and solvent volume - Unbeatable ease of operation - Wide temperature range for both viscosity and density - One measuring cell for the entire viscosity, density and temperature range Outer tube speed Outer tube (constant speed) Rotor speed Freely floating rotor (measured speed) Sample fluid Copper housing Magnet

These features make the difference There is an SVM viscometer for every application: ranging from measuring lubricating oils, used oils, crude oils, heavy fuels, distillate fuels to vegetable oils and fats. While SVM 3001 has unparalleled heating rates of up to 20 C/min, SVM 4001 is the best choice for fast Viscosity Index determination. Results are obtained much faster than using the glass capillary principle. SVM 4001 The best solution for Viscosity Index - Innovative double-cell design for simultaneous measurements at 40 C and 100 C - The fastest Viscosity Index determination from the lowest sample volume - State-of-the art intuitive software with 15 different parameters shown on the main screen Twice the benefits - Simultaneous determination of viscosity and density at any two temperatures between 15 C and 100 C - Viscosity-temperature extrapolation according to ASTM D341 - Freely selectable API grades shown on the 10 x 4 touchscreen SVM 4001 SVM 3001 SVM 2001 Unbeatable ease of operation - Simply inject the sample by a syringe and start the measurement - Easy and safe handling without leaks or breakage - Simple cleaning with a wash bottle - Low-maintenance - Factory-adjusted: ready for immediate use

SVM 3001 Wide temperature range from -60 C to +135 C - From jet fuel and diesel fuel to lubricating oils and wax with one integrated cell - Built-in air cooling down to -20 C - Cooling down to -60 C using external cooling (i.e. water/glycol mixture) More information with temperature scans - Temperature scans deliver fast and easily obtainable information on the temperature-dependent behavior of your liquid - Temperature table scans for viscosity and density determinations at freely selectable temperatures - Low-temperature studies on pumpability behavior SVM 4001 SVM 3001 Multiple parameter measurement from a single syringe - Kinematic viscosity (ASTM D7042, EN 16896, DIN 51659-2) - Viscosity Index (VI) (ISO 2909, ASTM D2270) - Density (EN ISO 12185, ASTM D4052, IP 365) - Dynamic viscosity (ASTM D7042) - API grades (ISO 91, API 2540, ASTM D1250, IP 200) - Saybolt viscosity (ASTM D2161) FillingCheck - The FillingCheck feature monitors the filling quality of the density cell in real time - Compliant with D4052 requirements - Saves valuable operating time

Your application Your benefits Distillate fuels Fast heating and cooling rates of up to 20 C/min Simultaneous determination of kinematic viscosity and density at any chosen temperature over a broad range Robust metal measuring cells Optional autosampler with up to 71 positions Compliance with: ASTM D7042 and D4052, EN 16896 Product specifications: ASTM D975 and D396 SVM 3001 Low temperature: Jet fuel, brake fluids, hydraulic fluids Measurements at -20 C without external cooling Methanol-free cooling down to -60 C; no flammable cooling liquids necessary Temperature scans for comprehensive information on low-temperature fluidity Cleaning and drying at sub-zero temperatures without warming up in between Compliance with: ASTM D7042 and D4052 Product specifications: ASTM D1655, D7566 and DEF STAN 91-91 SVM 3001 Lubricating oils, base oils and additives Oil condition monitoring Simultaneous measurements at two different temperatures for fast Viscosity Index determination Simultaneous measurement of kinematic viscosity and density for each temperature Optional autosampler with up to 71 positions Optional magnetic particle trap Compliance with: ASTM D7042, D4052, D7152 and DIN 51659-2; ISO 12185, ISO 91 Standard practices: ASTM D2270, D341, D6074 SVM 4001

Heavy fuels Robust measuring cells made of metal Precise Peltier temperature control up to +135 C Unprecedented heating and cooling rates of up to 20 C/min Simultaneous determination of kinematic viscosity and density Compliance with: ASTM D7042 and D4052, ISO 12185 SVM 3001 Transformer oils: Carbon-type composition Modular combination of SVM with Anton Paar refractometers Simultaneous measurement of viscosity, density and refractive index from one syringe Calculations of carbon-type composition and carbon distribution according to ASTM D2140 and D3238 All results are automatically calculated and displayed on the main screen within minutes Compliance with: ASTM D7042, D4052, D341, D2501, D2502 and D1218 (refractive index) Calculations according to: ASTM D2140 and D3238 SVM 3001 with Abbemat refractometer Vegetable oils and fats Raw materials for cosmetics Simultaneous determination of dynamic and kinematic viscosity Measurements at any temperature between 15 C and 100 C Easy and fast measurement from one syringe Optional autosampler with up to 71 positions Compliance with: ASTM D7042 SVM 2001

Accessories and modularity Simplify your daily lab routine Automated sample filling Maximize your productivity and minimize costs by employing sample changers from Anton Paar. Select an automatic system according to your sample s characteristics and plug it in SVM automatically recognizes it and is ready to go. While the sample changer takes care of repetitive tasks such as filling, cleaning and drying, you are free to do other important work. This automation option ideally serves all applications with high-throughput requirements. Choose either Xsample 340, a single unit for different types of syringes, or Xsample 530, a magazine sample changer for up to 71 vials. Easy filling of highly viscous samples The hot filling attachment keeps your sample warm for easy filling and prevents sample freezing (available for SVM 3001 and SVM 2001). Highly viscous samples are easily refilled for repeat measurements. The hot filling attachment is ideal for measuring samples with high melting points (such as wax) or samples with high pour points (such as heavy fuel or tar). Simple determination of carbon-type composition Your SVM can be combined with Anton Paar s Abbemat refractometer for simultaneous measurement of viscosity, density and refractive index from one syringe. This enables you to calculate carbon-type composition and carbon distribution according to ASTM D2140 and D3238. All results are automatically calculated and displayed on the main screen within minutes. Available with SVM 3001 and SVM 4001. Removal of magnetic particles from used oil samples The magnetic particle trap is an accessory designed to remove ferromagnetic particles from in-service oils. It is located close to the sample inlet to gather magnetic particles and keep them away from the measuring cell. The magnetic trap is electrically heated for optimized removal of ferromagnetic particles from the sample by decreasing the sample s viscosity.

Specifications SVM 2001 SVM 3001 SVM 4001 Temperature range +15 C to +100 C -60 C to +135 C +15 C to +100 C Viscosity range 0.2 mm²/s to 30 000 mm²/s Density range 0.6 g/cm 3 to 3 g/cm 3 Main standards ASTM D7042, EN 16896 ASTM D7042, EN 16896 ASTM D4052, ISO 12185 Supported precision classes Ultrafast, Fast and Precise Ultrafast, Fast, Precise and Ultraprecise ASTM D7042, EN 16896 ASTM D4052, ISO 12185 Ultrafast, Fast, Precise and Ultraprecise Sample volume min./typical 1.5 ml / 5 ml 1.5 ml / 5 ml 2.5 ml / 6 ml Solvent volume min./typical 1.5 ml / 6 ml 1.5 ml / 6 ml 2.5 ml / 10 ml Maximum sample throughput 30 samples per hour 24 samples per hour Peltier temperature control Designed for constant temperature Designed for fast heating/ cooling over a wide range Designed for simultaneous measurement at any two different temperatures within the range Optional automation Single syringe (5 ml or 10 ml) or 45 vials with 35 ml or 71 vials with 12 ml Wetted parts Inside the instrument: Copper, Titanium, Stainless steel A4, Inconel O-rings in contact with sample Viton Extreme Kalrez Spectrum 0040 Viton Extreme Data memory HID (Human Interface Device) Interfaces Power supply Ambient conditions 1000 measurement results Touchscreen; optional keyboard, mouse and 2D bar code reader 4 x USB (2.0 full speed); 1 x Ethernet (100 Mbit); 1 X CAN bus; 1 x RS-232; 1 x VGA AC 100 V to 240 V; 50 Hz to 60 Hz; 250 VA max. 15 C to 35 C (59 F to 95 F), max. 80 % r.h. non-condensing Net weight/shipping weight 15.9 kg/20.5 kg 17.6 kg/22.2 kg 17.8 kg/22.4 kg Dimensions (W x D x H) Compliance 33 cm x 51 cm x 23.1 cm (13 in x 20 in x 9.1 in) CE mark; EMC directive EN 61326-1; LV directive EN 61010-1; RoHS Special features Optional automation Automatic VI method, API calculations, temperature scans, FillingCheck. Optional: Countercooling, automation, modularity with Abbemat refractometers Double measurement cells for simultaneous viscosity and density measurement at any two different temperatures in the range, VI method, API calculations, FillingCheck. Optional: Automation, modularity with Abbemat refractometers All data refer to stand-alone instruments. For more information, please contact your Anton Paar representative.

2016 Anton Paar GmbH All rights reserved. Specifications subject to change without notice. D89IP002EN-C