Generator auto start/stop on CCGX and Venus GX

Similar documents
:43 1/13 Victron & BYD B-Box

ESS Design & installation manual

:34 1/15 Hub-4 / grid parallel - manual

ESS design & installation manual

ESS Design & installation manual

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

Hub-4 / grid parallel - manual

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i

Ion Technologies SUMPRO Battery Back-Up

VictronConnect - MPPT Solar Charge Controllers

Today. Smart Lithium batteries. MultiPlus-II. 3 phase systems. Firmware updating. Off Grid systems. Marine applications and new products

Gate & Door Controller with LCD and Intelligent Technology

Owner s Manual. Made in USA

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

APPLICATION NOTE: OPEN LOOP INTEGRATION WITH VICTRON ENERGY

MX60 PV MPPT Charge Controller

ICL Three Pump Controller

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

REVISION HISTORY REVISION HISTORY

ICON 2 1. FEATURES AND CHARACTEIRICS

WP Series Solar Charge Controller User s Manual. Please read this manual carefully before using this product.

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

Connecting other lithium systems to Multis and Quattros

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

BlueSolar charge controller MPPT 100/30

ALiEn 2 ALiEn 2 Expert. Installation and Operations Manual

DANGER. The Conext products below can utilize Load Shedding and Load Shifting:

SimpliPhi Power PHI Battery

Standby Generator Quick Reference Guide

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

SNMP dedicated to ORVALDI Solar Infini

Maximum Power Point Tracking (MPPT) KA1224MPPT20A KA1224MPPT40A. Solar Charge Controller. User Manual 20A

PowerChute TM Network Shutdown v3.1. User Guide. VMware

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

ECHO Enhanced Controller Hook Count Application *** Infrared Photo Sensors *** GCA 110 ECHO Controller. Version 3.5

5. OVERCURRENT RELEASE (OCR)

User Manual LV 3KVA-24V INVERTER / CHARGER. Version: 1.1

Pacesetter. Pacesetter Plus. Installation and Operations Manual

USER MANUAL ZHENGZHOU SMARTGEN TECHNOLOGY CO.,LTD

DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT WITH PARALLEL TO MAINS AND DUAL GENSET PARALLEL FEATURES

A U T O M A T I C T R A N S M I S S I O N M U L T I - C H A N N E L T W O - W A Y L C D R E M O T E S T A R T E R AS-2510 TW.

HERZ Electronic room thermostat analog and digital

HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

HGM6000K Series Automatic Generator Module OPERATING MANUAL Smartgen Electronic

PCT-3001 plus. Display LCD

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

Ventilation in balance

BMS 12/200 for 12,8 Volt lithium iron phosphate batteries Especially designed for vehicles and boats

Automatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list

Web/SNMP Management Card Event Support Chart

1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz.

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

DKG-109 AUTOMATIC MAINS FAILURE UNIT

GENSET CONTROL MODULE

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

DKG-509 AUTOMATIC MAINS FAILURE UNIT

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

Document Version Abbra_

A problem with the motor windings. A phase loss on mains terminals L1, L2, or L3 during run mode. Parameter 2-3 Current Imbalance Delay.

ML Maximum Power Point Tracking (MPPT) Series ML2420-ML2430-ML2440 Solar Charge and Discharge Controller

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

Overview. References TEST SPECIFICATION FORT WORTH, TEXAS TROTTER CONTROLS REPORT X TS-0005 A MODEL ORDER TITLE BY CHK D. Tests

HGM6000K Series Automatic Generator Module USER MANUAL Smartgen Technology

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

Manual. Lynx Ion 24V/180Ah Lithium Ion Batteries

Using the Phoenix MultiPlus to reduce operating cost of a generator

ECLIPSE Laundry Dispenser Controller

Rand McNally Device Software. What s New (Version )

Deep Sea Electronics Plc

AKD Controlled Stop and Holding Brake Timing Jimmy Coleman, Rev. B, 5/1/2017

PV Master OPERATION MANUAL

Bunya Solar. Renewable Energy Systems. Remote area power supply system manual

SimpliPhi Power PHI Battery

HAT700 Series HAT700/HAT700I/HAT700B/HAT700BI/HAT700S ATS CONTROLLER USER MANUAL

User Guide WARNING TWO-WAY 6-BUTTON LCD AUTOMATIC/MANUAL TRANSMISSION REMOTE STARTER SYSTEM WITH FULL ALARM SYSTEM

1. General Description

Manual. Handleiding. Manuel. Anleitung. Manual. VE.Bus BMS. ES Appendix

ASPIRO & GUARDIAN BATTERY MANAGEMENT WITH ACC EXTENDED CONTROLLER

DKG-707 MULTI GENSET PARALLELLING UNIT WITH J1939 INTERFACE

SST-3 Start-Stop-Throttle

4KVA/5KVA Parallel Installation Guide

RV Series Remote Control Manual Type. Owner s Manual RC/GS RC7. RC/GS Remote Control/Gen Starting

DKG-109J AUTOMATIC MAINS FAILURE UNIT

The measurements module provides the following engine features information:

How To AC Couple Grid Tied Inverters with OutBack Frequency Shifting Inverters

3 40W. Product Introduction. 1440mm(56.7in) 560mm (22in) 440mm (17.3in

TWO-WAY LCD AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide

DKG-215 MANUAL AND REMOTE START UNIT

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL

AS-4000 OPERATING INSTRUCTIONS (PS-5000)

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

HGM6100K Series Automatic Generator Module OPERATING MANUAL Smartgen Electronics

AS-1414/ AS-1424 Installation Guide

Ventilation in balance

Operations Manual Pika Harbor Smart Battery

Transcription:

2017-08-17 22:47 1/8 Generator auto start/stop on CCGX and Venus GX Generator auto start/stop on CCGX and Venus GX Introduction The internal relay can be used to automatically start and stop a generator. With this functionality you can set conditions to make the relay open or close. Wire the relay to a genset in such matter that the genset will start as soon as the relay is closed. Then it needs to keep running until the relay is opened again. On Venus GX there are two relays available, only Relay 1 is used by the generator auto/start stop functionality. Besides driving the internal relay, the auto start/stop functionality can be also enabled to directly control supported Fischer Panda generators. For more information on how to connect Fischer Panda generators, see CCGX & Fischer Panda generators. Enable the start/stop function Relay Go to: Setttings Relay and set function to Generator start/stop Once enabled, all settings will become available in Settings Generator start and stop. Fischer Panda Victron Energy - https://www.victronenergy.com/live/

Last update: 2017-08-17 13:43 ccgx:generator_start_stop https://www.victronenergy.com/live/ccgx:generator_start_stop 1. 2. Enable the AutoStart function in the Fischer Panda generator control panel. Go to the Fischer Panda genset page and set the Mode setting to Auto start/stop Once the mode is set, all settings will become available under the Auto start/stop menu entry at the bottom of the page. Main page Generator state: Condition that is currently keeping the generator running. Error: Error description. Runtime: Generator runtime since last start. Total run time: Accumulated running time since the first start. Time to next test run: When the test run condition is enabled this item shows the time remaining to the next test run. Daily runtime: Page with the running times of last 30 days. Settings: Generator start and stop settings menu. Settings https://www.victronenergy.com/live/ Printed on 2017-08-17 22:47

2017-08-17 22:47 3/8 Generator auto start/stop on CCGX and Venus GX Conditions: See Conditions Minimum runtime: Once started the generator should run for a minimum amount of time, for manual start this setting is ignored. Detect generator at AC input: After starting the generator, it monitors the Multi (or Quattro), to see if it connects to the generator. In case it does not it will cause an alarm. This function catches a wide array of possible problems, like a simple no fuel situation, but also a tripped fuse or other problem between the generator and the Quattro. This functionality is not available for VE.Can connected Multi/Quattro. Quiet hours: See Quiet hours Reset daily run time counters: Reset the last 30 days run time counters. Generator total run time: Sets the total run time counter. Conditions Conditions location: Generator start and stop Settings Conditions * Battery monitor: Select which battery monitor will be used for DC related conditions. * On loss of communication: Defines the behavior when the datalink between the CCGX/Venus GX and the selected battery monitor and/or vebus inverter/charger is lost. Options are: Victron Energy - https://www.victronenergy.com/live/

Last update: 2017-08-17 13:43 ccgx:generator_start_stop https://www.victronenergy.com/live/ccgx:generator_start_stop Stop the generator: If the generator is running and the datalink is lost, the generator will be stopped. (default) Start the generator: If the datalink is lost and one or more conditions depends on it the generator will be started. Keep running: If the generator was already running before the datalink loss this setting will keep it running, but will not start it if was not running previously. * Do not run genset when AC 1 is in use: It is intended for backup systems, with a Quattro, having mains on AC in 1, and Genset on AC in 2. When this option is enabled, the Genset will only be started after a mains failure. And in case of a mains failure, the Genset will automatically be stopped again as soon as the mains is restored. This functionality is not available for VE.Can connected Quattros. The following conditions are available to auto start/stop a generator: Manual State of charge (SOC) AC load* Battery current Battery voltage Inverter high temperature Inverter overload Periodic test run * The measured value is the system total AC consumption. Conditions are evaluated in the order shown above and when multiple conditions are reached only the top one will be shown as active condition. All enabled conditions are evaluated even if the generator is already started so when the active conditions ends, the next reached condition will keep the generator running. Condition settings Use condition value to start/stop: Enables or disables the condition Start when condition is higher/lower* than: When the value set here is reached, the relay is closed to start the generator. Start value during quiet hours: The same that above but when the Quiet hours mode is active. https://www.victronenergy.com/live/ Printed on 2017-08-17 22:47

2017-08-17 22:47 5/8 Generator auto start/stop on CCGX and Venus GX Start after the condition is reached for: Some values like AC load can vary suddenly due to a consumption peak and go back to a normal value in a few seconds. In this kind of situations the start of the generator is usually not desired. This option will delay the generator start until the start value is reached for a minimum amount time. Stop when condition is higher than: The same than above but for stop value. Stop value during quiet hours: The same than above but for stop value. Stop after the condition is reached for: The same than above but for stop value. * Higher/lower value depends on the type of condition. AC load condition AC load condition works like the rest of conditions but has the Measurement extra setting. The Measurement setting is available on firmware v2.0 and onwards and has three possible values: Total consumption (Default option) Inverter total AC out Inverter AC out highest phase Test run condition Allows you to program a periodical test run. Test run interval: Test run will be performed periodically based on this setting Victron Energy - https://www.victronenergy.com/live/

Last update: 2017-08-17 13:43 ccgx:generator_start_stop https://www.victronenergy.com/live/ccgx:generator_start_stop Skip test run if has been running for: The test will be skipped if during the test run interval the generator was running at least the number of hours set on this setting. Test interval start date: The interval count will start based on this date, this setting can be set in the future and the interval will be ignored till the set date is reached. Start time: Time of day in which the generator will start Test duration: Duration of the test Run until battery is fully charged: Stops the generator after the battery is fully charged instead of a fixed amount of time Manual start Use the manual start to directly start the generator. If the generator is already running you can use this option to make sure that the generator won't stop automatically when the active condition becomes inactive. There are two ways to start the generator manually: Using menu: Go to Generator start and stop Manual start and use the switch to start the generator. Using generator page: Press the top-left button to show the generator page. Once in the generator page press the center button, when pressed you will be asked how to stop the generator, manually or using a timer. Once selected the stop mode a countdown of five seconds will start, you can abort the manual start by pressing the center button. https://www.victronenergy.com/live/ Printed on 2017-08-17 22:47

2017-08-17 22:47 7/8 Generator auto start/stop on CCGX and Venus GX WARNING: If the generator is manually started without a stop timer, won't stop until the user set to off the manual start option. In both options the use of a stop timer is available, use the timer to program the generator stop. Manually stop the generator is only possible if no other condition is active. In the case that you want to force the stop you should disable the active condition or disable the generator start and stop function. Quiet hours Quiet hours allows you to set a time zone for nighttime with values that make the generator start only when is really necessary. When the Quiet hours mode is active, the conditions will use the related start/stop values. To enable it go to the settings menu and set the Enable quiet hours switch on. Once enabled start and end time settings will become visible. You can make the Quiet hours mode to be permanently active(when enabled) setting both start and stop time to the same value. Using "Quiet hours" to define two time zones Besides the main purpose of the Quiet hours mode you can also use it to define two time zones over the day. Victron Energy - https://www.victronenergy.com/live/

Last update: 2017-08-17 13:43 ccgx:generator_start_stop https://www.victronenergy.com/live/ccgx:generator_start_stop Examples of the use of different time zones: Solar system: A cloudy morning may cause the generator to start by a low SOC condition, then two hours after the clouds go away. In this case your batteries are charged and your solar system wasting free energy. To avoid this situation you can set a time zone for daytime with a lower start value for the SOC condition. Away mode: Some holiday houses are only inhabited on weekends during which power consumption is larger and the generator has to take care of keep batteries in good condfition. The rest of the week the battery SOC level can be lower waiting to be charged by solar energy. With time zones you can set a secondary time zone for the whole day and only enable/disable it when the house is uninhabited. Troubleshooting Fischer Panda: Generator does not start and "Remote switch control disabled" error is shown Enable the AutoStart function in the Fischer Panda control panel. Fischer Panda: Auto start/stop function stopped working after an error Make sure that the issue is solved and clear the error to make the auto start/stop function work again. DISQUS View the discussion thread. From: https://www.victronenergy.com/live/ - Victron Energy Permanent link: https://www.victronenergy.com/live/ccgx:generator_start_stop Last update: 2017-08-17 13:43 https://www.victronenergy.com/live/ Printed on 2017-08-17 22:47