This Datasheet for the IC670MDL930. Relay 2A 8 Pt. 6 form A/2 form C Isolated.

Similar documents
Solenoid Valve Output Module IC693MDL760 Product Description

Discrete Output Modules IC697MDL753

Solid-State Relays. Solid-State Relays. Features. Description. Overview

Solid-State Relays. Solid-State Relays. Features. Description. Overview

TYPE 5867 PORTABLE Q METER

GE Sensing & Inspection Technologies

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

PS24/AC Volt AC 16 Amp

Uninterruptible Power System

Electrical: Valve monitoring and control circuits

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

Application Engineering

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Versatile and Rugged Industrial LIthium/LiPO Charger Series

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

Pluggable interface relays RT, PT and MT range

Product discontinuation. Notices. Discontinuation Notice of Safety Relay and Socket. G7S series, P7S series. Wire connection

Redundant Control System

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

Uninterruptible Power System

48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp

4 Redundant Control System

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family

FT-10 Network Digital I/O Module Kits and

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

DC3N Non-Regenerative DC Drives

5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps

Technical Information

INTER PLANT STANDARD - STEEL INDUSTRY THYRISTOR CONVERTORS FOR ARMATURE AND FIELD OF MAIN DRIVE MOTORS. Corresponding IS does not exist

Softstarters. Softstarters Power electronic brakes Type PEB

Application Engineering

Power electronic brakes

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Uninterruptible Power System

Local Control Network - building controls in perfection

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

SED2 VFD NEMA Type 3R and Type 3R Harsh Environment (3RHE) Bypass

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installing Power Components

SPECIAL SPECIFICATION 5273 Dragnet Vehicle Arresting Barrier

Process switches and PLC circuits

Carbon Monoxide Transmitter

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

Transfer switch GTEC open or delayed transition

Relays. Industrial Automation Catalog Section - U906. Selection Guides. Solid State Relays RSS Series

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Noran Tel. FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified

1x 20A H Bridge output for controlling direction of DC motors through polarity change (MOI)

SE2000BX Static Exciter

Flight Systems. Replacement for KASSEC DESCRIPTION

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Application Guide Paragon TM Control Module (PCM) Slide Valve and Protection Control 10/25/2016 Rev 1. Carlyle Controller Part No.

TI23 Pre-Instructional Survey

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

SST-ST75F-ESS The essential silver standard

8 Channel 5V Optical Isolated Relay Module

Zero Cross Over Turn On Thyristor Switch Card for Capacitor Bank

Induction Power Supplies

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

1.0 Features and Description

Explanation 1 Input External Switch 2 Input Hipot Safety Switch

POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation

1250W APS X Series 12VDC 230V Inverter/Charger with Auto Transfer Switching, 2 C13 Outlets

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC

MDE-2381A SERVICE MANUAL. PA0242 Distribution Box GILBARCO INC., 7300 W. FRIENDLY AVENUE, P.O. BOX 22087, GREENSBORO, N.C /90/.

Rosemount 8750WB Magnetic Flowmeter System

CM52 Network Protector with Arc Flash Reduction Module

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

Features. Description. Table of Contents

MLA Bipolar Microstep Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

Silvertel. 1. Features. 2. Description. IEEE802.3at compliant. Maximum 30 Watt Output Power. High efficiency DC/DC converter

AF series contactors (9 2650)

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Emergency lighting units EM powerled

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

SECTION MOTOR CONTROL

Timer Relays - Fixed & Adjustable

E.S.P. Embedded Sensing Probes for Motor Brushes

Power Switching Principles

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

PROGRAMMABLE DC POWER SUPPLY MODEL 62000P SERIES

Proportional pressure reducing valves type DHRZO direct operated, ISO 4401 size 06

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Troubleshooting Bosch Proportional Valves

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1.

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit

Transcription:

This Datasheet for the IC670MDL90 2A 8 Pt. 6 form A/2 form C Isolated http://www.qualitrol.com/shop/p-142-ic670mdl90.aspx Provides the wiring diagrams and installation guidelines for this GE Field Control module. For further information, please contact Qualitrol Technical Support at 1-800-784-98 support@qualitrol.com

Discrete Output Module IC670MDL90 (IC670MDL90) datasheet The Isolated, /NC Output Module (IC670MDL90) provides eight isolated outputs. The outputs consist of six normally-open (Form A) contacts and two normally-open or normally-closed (Form C) contacts. Six form A relays provide the outputs while two form C relays provide the /NC points. 467, 0/60 HZ RELAY, ISO, /NC 2A PILOT DUTY SLOT 8A 7A 6A A 4A A 2C 1C, 0/60 HZ RELAY, ISO, /NC 2A PILOT DUTY PWR Power Sources The power that runs the module itself comes from the power supply in the Bus Interface Unit. An external source of AC and/or DC power must be provided for the loads driven by the contacts. LEDs Host Interface Individual LEDs (logic side), visible through the transparent portion of the module top, indicate the on/off status of each output. The PWR LED is on when backplane power is present. Intelligent processing for this module is performed by the Bus Interface Unit or elsewhere in the system. This includes configuring features such as output default and fault reporting. The module has 8 bits (one byte) of discrete output data. A Bus Interface Unit is required to obtain this output data from the host and/or local processor.

2 Discrete Output Module Module Operation After checking the Board ID and verifying that the module is receiving appropriate logic power from the Bus Interface Unit (as reflected by the state of the module s Power LED), the Bus Interface Unit then sends output data to the module in serial format. During transmission, the module automatically loops this data back to the Bus Interface Unit for verification. Serial to parallel converters convert this data into the parallel format needed by the module. Opto-isolators isolate the module s logic components from field outputs. Power from the external power supply is used to power the loads connected to the contacts. Field Terminals Internal Module Circuitry Connections 4676 V 47. W.022mF.022mF Form C Driver NC 47. W Snubber Interface to Bus Interface Module V 47. W.022mF Form A Driver Snubber Maximum Load Rating The resistive rating of the module is 2 amps per point at 120/ or and 0.2 amps per point for 12 VDC. Power to energize the relay coils is supplied by the module. An RC snubber is used across the contacts. Suppression Each output is suppressed with an RC snubber to reduce high frequency noise transients. Proper suppression of the switched load is still recommended and will contribute to improved system reliability. Suppression at the load will not only lengthen contact life, but will also reduce noise transients in the control wiring.

Discrete Output Module Module Specifications Module Characteristics Configuration Rated Voltage Voltage Range Maximum Load Current (resistive) Indicators Isolation: User input to logic, user input to frame ground, group to group Type Current Drawn from BIU Power Supply Output Characteristics Maximum Load Current (resistive) Maximum Inrush Minimum Load Current Output Leakage Response Time-On Response Time-Off Switching Frequency Contact Type Contact Resistance Contact Life Protection (each output) Vibration (this module) 6 points - Form A (each point isolated) 2 points - Form C (each point isolated) /24/12 VDC, 120/ 010 VDC, 026 VAC (476 Hz) 16 amps per module Individual logic side LEDs indicate the status of each output. The PWR LED indicates the presence of backplane power. 20 VAC continuous, 100 VAC for 1 minute. No isolation between individual points in a group. Fixed coil, moving armature 1 ma maximum (see chart on the next page) s from to 26VAC s from to 0VDC 0.2 Amps from 1 to 12VDC Amps for 20mS 10 ma per point 2 ma at 120 VAC maximum 10 ms (max) 10 ms (max) 20 cycles/minute (inductive load) Silver Alloy 0.2 (initial) at 1 A, 6 VDC Mechanical: 20 x 10^6 operations Electrical: 10^ operations at rated resistive load Snubber (R=47. ohms, C=0.022 ufd). No fuse IEC68-2-6: 10 to 7 Hz 0.012in displacement (peak to peak) 7 to 00 Hz at 1. G

4 Discrete Output Module BIU Power Drain per Point The Output Module s BIU power requirement increases as the number of points that are simultaneously on increases. The chart below shows the relationship between the power required and the number of points that are on. Current Drawn from BIU Power Supply (ma) 1 277 241 20 169 1 97 61 2 0 0 1 2 4 6 7 8 Number of Points On Typical Contact Life versus Load Conditions Operating Maximum Current for Load Type Typical Contact Life Voltage Resistive Inductive * (number of operations) 24 120 VAC 24 120 VAC 24 120 VAC 24 120 VAC 0.1 Amp 0.1 Amp 0.1 Amp * Power Factor = 0.4 minimum for AC inductive loads Time Constant 7mS for DC inductive loads 0. Amp 0.0 Amp 0. Amp 0.0 Amp 0. Amp 0.0 Amp 00,000 10,000 00,000 1,000,000 10,000 0,000 200,000 00,000 00,000 100,000 00,000 1,000,000

Discrete Output Module Keying Locations Optional keying locations for the Isolated, /NC, Output Module are shown below: Field Wiring Keying Locations A B C D E F G H J K The diagram below shows input and power connections for the module s two normally-open or normally-closed (Form C) contacts (labelled 1C and 2C on the module) and six normally-open (Form A) contacts (labelled A, 4A, A, 6A, 7A, and 8A). Outputs 1C, 2C Outputs A, 4A, A, 6A, 7A, 8A 4677 + H N + H N NC I/OTerminal Block wiring assignments for this module are shown below. Note: 1 through 8 may be connected together if a single supply is required. However, the maximum current through any one terminal may not exceed 10 Amps. I/O Terminal Block with Box Terminals (IC670CHS002 and 102) Com 8A Com 7A Com 6A Com A Com 4A Com A 2C NC 2C 16 14 E8 12 10 E6 8 6 E4 4 2 E2 B2 B1 1 1 11 9 7 1 E1 A2 A1 8A 7A 6A A 4A A 1C NC 1C 4678 Terminals E1, E2, E4, E6, and E8 are electrically connected together, A1 and A2 are electrically connected together, B1 and B2 are electrically connected together. I/O Terminal Block with Barrier Terminals (IC670CHS001 and 101) Com 8A Com 7A Com 6A Com A Com 4A Com A 2C NC 2C 16 14 12 10 8 6 4 2 B 1 1 11 9 7 1 A 8A 7A 6A A 4A A 1C NC 1C 4642 4628 I/O Terminal Block with Wire to Board Connectors (IC670CHS00 and 101) 6A Com 6A 7A Com 7A 8A Com 8A 11 12 1 14 1 16 A2 A1 B2 B1 10 9 8 7 6 4 2 1 Com A A Com 4A 4A Com A A 2C 1C NC 2C NC 1C