Process Analyzer. Viscosity Index Analyzer Model P-950. Credible Solutions for the Oil and Gas Industry

Similar documents
Process Analyzer. Flash Point Analyzer Model P-500. Credible Solutions for the Oil and Gas Industry

Process Analyzer. Reid Vapor Pressure Analyzer Model P-700. Credible Solutions for the Oil and Gas Industry

Process Analyzer. Cold Filter Plugging Point Process Analyzer CFPP-4. Credible Solutions for the Oil and Gas Industry

FPA4 DATASHEET JUNHO 2013

Flash Point Process Analyzer

CFPP Process Analyzer

Technical Offer. ViscoPro Measure Viscosity and Temperature on line for continuous process improvement

State-of-the-art viscosity monitoring

Stabinger Viscometer SVM 3001

Physical Property Analyzer PPA4100 Series. On-Line RVP Analyzer

Why measure viscosity in-line?

better analysis counts

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

ViscoSense 3D. Viscosity & Density Measurement Enabling Mass Flow Measurement. Product Bulletin TO BE REALLY 1 SURE

Micro Motion 7827 Digital Viscosity Meter

STANDARD COMPLIANT VAPOR PRESSURE

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

Flow Measurement Technology Training

Turbine flowmeters Series TM

Coriolis Flow Solutions for a Global Marketplace

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

DUCOM HIGH FREQUENCY RECIPROCATING RIG

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

Online data sheet S710 E S700 EXTRACTIVE GAS ANALYZERS

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

MiniLab EL Series for High Performance Engine Development and Maintenance

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Coriolis Flow Solutions for a Global Marketplace

Sample gas pumps P2.x ATEX

Agilent 7693A Automated Liquid Sampler

AKVdiesel. Automated kinematic Viscometer key features. Fully complies with ASTM D445. Two measuring positions. Remove cap and pour in sample

ISBN SANS 342:2006 Edition 4 SOUTH AFRICAN NATIONAL STANDARD Automotive diesel fuel Published by Standards South Africa 1 dr lategan roa

Instruments for the Analysis of Petroleum Products. Oxidation Stability

A unique density, viscosity sensor. High technology brick. Field oriented. For light & medium petroleum products. Related norms

VersaFlow Vortex 100 Vortex Flow Meter Specifications

White Paper.

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

K - Flow Meter with Float

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

Agilent 7693A Automated Liquid Sampler

Viscomaster TM series viscosity transmitters for marine and power HFO applications

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

Series 3730 Electropneumatic Positioner Type

Magnetic-inductive flow meter for hazardous areas

Oil/Air Cooler Units. Standard series OK-P type. Test procedure certified following EN

PAB Atex-certified centrifugal pumps

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Vapor Pressure Measurement Of Gasoline, Crude Oil & LPG With New ASTM D5191 & D5188 Speed Test

Oil Mist Detection multi-sensor-system for 2-stroke engines

Viscomaster TM series viscosity transmitters for marine and power HFO applications

Product Specification. EF2100 Series

Stabinger Viscometer Series. SVM Series

VISCOSITY CALIBRATION STANDARDS

Explosion proof electric motor For Fuel dispensing application. Main characteristic

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

EC series GMS30CS-AU 50

DDA AR-PVC/V/C with access.

Measuring Systems for Quality Control in Biodiesel Production. ::: Great People Great Instruments

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

RMF SYSTEMS CONDITION MONITORING CENTER PURE POWER

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

Phase Technology PPA-70Xi Pour Point Analyzer

CWD2000 EX. Calorimeter with type examination certificate for operation in hazardous areas. Measurement parameter. Applications

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light

Jet Fuel Conductivity Analysers & Additive Management systems

MiniLab EL Series for High Performance Engine Development and Maintenance

High Accuracy Bunker Blending / Bunker Control

POWER TRANSMISSION. Product range

8,000 Watt Diesel Generator

Manual Kinematic Viscosity Bath Tamson TV12

HG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS

Density Solution. TDF Series. Direct Insertion Density Meter. Characteristics

Leading the way in hazardous areas Features EATON

CYCLOPS X Purge Controller SM Version

High Accuracy Bunker Blending / Bunker Control

The Advantage of Real Atmospheric Distillation using D7345 Test Method. Presented by Jonathan Cole, PAC

Flowmeters. The Satam flowmeter range is used for the custody transfer measurement of liquid hydrocarbons, liquid gas and liquid chemicals.

VALIADIS S.A. HELLENIC MOTORS

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

ElvaX Sulfur in Oil analyzer

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Conditioning Module Reservoir Extraction CM-RE

T u r b i n e P e r f o r m a n c e L i d a r

7829 Visconic industrial viscosity transmitter on line real time viscosity measurement

U tube viscometer. Kinematic viscosity bath RASAYAN

HY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm)

Viscosense 3. Viscosity Measurement & Control Systems. Product Bulletin TO BE REALLY SURE

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

UPGRADE PROGRAM. V141 Series Pumps vs Turbo-301 Series Pumps. Technical Memo

ISO 2909 / ASTM D

Online data sheet GMS800 FIDOR EXTRACTIVE GAS ANALYZERS

Transcription:

Process Analyzer Viscosity Index Analyzer Model P-950 Credible Solutions for the Oil and Gas Industry

Viscosity Index Analyzer Process Model P-950 Analyzer To remain competitive, today s refiners must employ all optimization and product control techniques available. The use of online physical property analyzers is one of the key features to reach those objectives because they measure important quality properties in the process directly. The viscosity index is a widely used and accepted measure of the variation in kinematic viscosity due to changes in the temperature of a petroleum product between 40 C and 100 C. A higher viscosity index indicates a smaller decrease in kinematic viscosity with increasing temperature of the product. Your partner for innovative system solutions. Capillary type of viscometer Correlates with ASTM D445 / ASTM D2270 Certified for installation in hazardous areas The BARTEC specialists have many years of experience. They create system solutions that you can rely on: efficient and dependable for decades to come. APPLICATION Given today s highly competitive environment, oil refiners are demanding instrumentation that aids in the optimization of the refining process. Therefore, refineries require a reliable and accurate viscosity analysis system to meet the required specifications. This analysis will allow the operators to optimize the refining process and therefore lower production costs while improving product quality.

Special Features: Customizable 2-4000 cp Sample Range (kinematic output in cst) Continuous Sample Viscosity and Viscosity Index output Does not require atmospheric recovery system Modbus Remote Bath Temperature Set Point Change Up to 8 programmable Viscosity Points Norms and Standards: Correlates with: ASTM D445 ASTM D2270 Make your decision for a strong partner! Choose BARTEC GROUP also for: Fast Loop Systems Sample Conditioning Systems Validation Systems Recovery Systems Chillers Air Conditioning Systems/HVAC Pre Commissioned Analyzer Shelters/ Turn-Key Solutions oil gas refineries petrochemistry chemistry

Viscosity Index Analyzer Model P-950 EXPLOSION PROTECTION Ex protection marking TECHNICAL DATA Technology Method Measuring ranges and temperatures Repeatability Reproducibility Measuring cycle Product streams Electrical data Nominal voltage ATEX: Ex d II B + H2 [ia II C] T3 Gb CSA/CUS Class I Div 1 Group C + D dual bath capillary type correlates with: ASTM D445, ASTM D2270 up to 4000 cp ± 1 % full scale correlates with: ASTM D445, ASTM D2270 continuous lube oils, asphalts and bunker fuels 220 VAC, 50/60 Hz, 1 phase Heater and Pumps 120/220 VAC, 50/60 Hz, 1 phase Electronics Maximum power consumption 30 A, less than 6000 W Protection class IP 65 Ambient conditions Ambient temperature operation 5 to 40 C (41 to 104 F) Ambient humidity up to 90 % Sample Quality Properties Consumption Pressure at inlet Temperature at inlet Process sample 0518 less than 10 µm, filtered 5 l/h (fixed meter in pump) 1.4 to 14 bar (20 to 203 psi) ± 38 C (68 F) of bath temperature max temperature 111 C (232 F) Signal outputs and inputs Analog outputs 3 standard, VI, V40 and V100 Digital outputs up to 3 dry contacts programmable, remote standby, analyzer fault, value alarm Digital inputs up to 2, customer alarm, remote standby Electrical data of signal outputs and inputs Analog outputs Digital outputs Digital inputs User interfaces Display Keyboard Connections Sample inlet Sample outlet Weight and dimensions Weight Dimensions (W x H x D) 3 standard 3 standard dry contact 7 color graphics 5 button magnetic, no hot work permit required 1/4 FNPT 1/4 FNPT approx. 272 kg (600 Ibs) approx. 1575 x 1938 x 381 mm (62 x 76 x 30 in) Optional interfaces Analog outputs optional (bath temperature, density) MODBUS interface TCP/IP or Serial/RTU 485 Utilities Coolant Consumption Temperature Pressure at inlet Quality depends on application (consult factory) 0 to 50 C (32 to 122 F) 1 to 60 bar (14 to 870 psi) clean and filtered (10 µm) Important notice P-950 is subject to continuous product improvement, specifications are preliminary and may be subject to change without notice. If your technical data do not comply with existing data, please contact us for technical clarification. BARTEC ORB 4724 South Christiana Chicago, IL 60632 / USA Tel: + (1) 773 927-8600 Fax : + (1) 773 927-8620 sales@bartec-orb.com www.bartec-orb.com

Viscosity Index Analyzer Model P-950