Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40

Similar documents
Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40TA, with component testing

Differential pressure switch Model DPS40

Differential pressure gauge with output signal For the process industry, all-metal media chamber Models DPGT and DPGT43.160

Mechatronic pressure measurement. Applications. Special features. Description

Differential pressure gauge with switch contacts For the process industry, all-metal media chamber Models DPGS43.100, DPGS43.160

Differential pressure gauge Model , copper alloy Model , stainless steel version

Differential pressure gauge For the process industry Models , , high overload safety up to 40, 100 or 400 bar

Differential pressure gauge with switch contacts For the process industry Models DPGS43HP.1x0, high overload safety up to 40, 100, 250 or 400 bar

Bourdon tube pressure gauge with switch contacts Stainless steel case Model PGS21, NS 100 and 160

Absolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models , and

Bourdon tube pressure gauge, copper alloy Panel mounting series Models and

Gas-actuated thermometer with switch contacts Stainless steel version Model 73

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

Compact differential pressure switch Models DC, DCC

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

Differential pressure gauge with electrical output signal Model A2G-15

Surface thermocouple Model TC50

Mini pressure switch Stainless steel switch enclosure Model PXS

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Bimetal thermometer Model 52, industrial series

Measuring insert for process resistance thermometer

Gas-actuated thermometer with switch contacts Model 73, stainless steel version

Compact pressure switch Model PCS

Pressure switch, high adjustability of switch differential

Compact temperature switch Model TCS

Duct thermometer Model TF40

Gas-actuated thermometer Highly vibration resistant Model 75, stainless steel version

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Bimetal thermometer Model 52, industrial series

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Diaphragm pressure gauge, flush For sanitary applications Model PG43SA-S, NS 100

Insertion thermometer With connection lead Model TF45

Mini temperature switch Stainless steel switch enclosure Model TXS

Bourdon tube pressure gauge per DIN Panel mounting series for rail-vehicle braking systems Model PG21PB, NS 60, 80 and 100

Cable resistance thermometer Model TR40

Gas-actuated thermometer with switch contacts For sanitary applications, stainless steel version Model 74

Diaphragm seal with threaded connection Plastic version Model

Diaphragm pressure gauge, flush For sanitary applications, NS 100 Model PG43SA-D, with integrated diaphragm element monitoring

Diaphragm seal with sterile connection For homogeniser machines Model

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

Resistance thermometer with digital display Model TR75, battery operation

Thermocouple Without thermowell Model TC10-H

Thermocouple For additional thermowell Model TC10-B

Cable thermocouple Model TC40

Duplex pressure gauge per DIN Panel mounting series for rail-vehicle braking systems Model PG21DPB, NS 60, 80, 100 and 130

Reed sensor For bypass level indicators Model BLR

Bourdon tube pressure gauge with switch contacts Models PGS21.1x0, industrial series

Gas-actuated temperature switch Stainless steel switch enclosure Model TWG

Diaphragm seal with flange connection For the pulp and paper industry Model

Resistance thermometer Without thermowell Model TR10-H

Gas-actuated thermometer Model 73, stainless steel version

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and

Accessories for diaphragm seals Block flange and saddle flange Models , ,

Cable resistance thermometer Model TR40

Machine glass thermometers Model 32, V-Form

Cable resistance thermometer Model TR40

Bourdon tube pressure gauges with switch contacts Models PGS23.1x0, stainless steel version

High-pressure thermocouple Model TC90

High-quality pressure sensor with mounted diaphragm seal With threaded connection, threaded design Model DSS10T

High-quality pressure sensor with mounted diaphragm seal With threaded connection, welded design Model DSS34T

Bimetal thermometer with Pt100 electrical output signal Model 54, stainless steel version

Diaphragm seal with sterile connection With union nut (milk thread fitting) Models , , and

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Bimetal Thermometers Process Industry Series, Model 55

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Pressure gauge per EN with mounted diaphragm seal With threaded connection, threaded design Model DSS10M

Resistance thermometer Model TR10-E, for additional thermowell

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Measuring insert for resistance thermometer Model TR10-A

Temperature multi-function calibrator Model CTM

High-quality pressure sensor with mounted diaphragm seal With flange connection, flush diaphragm Model DSS27T

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

Diaphragm seal with sterile connection For sanitary applications Models , , and , threaded connection

Cable thermocouple Model TC40

Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Thermocouple Model TC10-H without thermowell

Pressure gauge per EN with mounted diaphragm seal With SMS threaded connection Model DSS19F

OEM pressure transmitter with thin-film technology For mobile hydraulics Model MH-2

Bourdon Tube Pressure Gauges with Switch Contacts Models /160, Stainless Steel Version Models /160, Stainless Steel Safety Version

Float switch For industrial applications, with temperature output Model RLS-3000

Thermocouple with spring-loaded tip Model TC55

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Electronic flow switch With display, for liquid media Model FSD-3

Portable pressure calibrator, Wally Box III Model CPH7600

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A

High-quality pressure sensor with mounted diaphragm seal With clamp connection Model DSS22T

Pressure gauge per EN with mounted diaphragm seal With clamp connection Model DSS22F

Bimetal Thermometers Model 54, Heavy Duty Series

Pressure gauge in hygienic design with mounted diaphragm seal With clamp connection Model DSS22P

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Gas Actuated Thermometers Stainless Steel Series, Model 73

DPT 200. Differential Pressure Transmitter for Process Industry with HART -Communication. accuracy according to IEC 60770: 0.

Diaphragm monitoring system with clamp connection For sanitary applications Model DMS-FP

Thermowell For sanitary applications Model TW61, for orbital welding

Tubeskin thermocouple assembly Model TC59-W

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

Transcription:

Mechatronic pressure measurement Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40 WIKA data sheet PV 17.19 Applications weitere Zulassungen siehe Seite 5 DELTA-trans Monitoring of filters, compressors and pumps in: Marine boilers, pressure vessels, bilge-water collection Drinking and cooling-water treatment plants Pressure-boosting stations, heating technology, fire-extinguishing systems Special features Transmission of process values to the control room (e.g. 4... 20 ma) Robust aluminium case with shatterproof window High ingress protection, IP65 Optional: Explosion protection per ATEX Differential pressure gauge with output signal, model DPGT40 Description The differential pressure gauges of the DELTA-line product family are primarily used for the monitoring of low differential pressures where there are high requirements in terms of one-sided overpressure and static pressure. Typical markets for these products are the shipbuilding industry, process heating technology, the heating, ventilation and air-conditioning industries, the water/wastewater industry, and machine building and plant construction. For these, the main function of the measuring instruments is the monitoring of filters, compressors and pumps. Wherever a signal transmission is needed and, at the same time, a differential pressure must be displayed locally, the DELTA-trans finds its use. An electronic angle encoder, proven in safety-critical automotive applications, determines the position of the pointer shaft - it is a non-contact sensor and therefore completely free from wear and friction. From this, the electrical output signal proportional to the pressure, e.g. 4... 20 ma, is produced, which then acts to transmit the signal to the control room. In addition, the electrical zero point can be set manually. Often in these applications, alongside the indication of the differential pressure, the current working pressure is also relevant. For this reason, a working pressure indication is integrated within the DELTA-trans differential pressure gauge with output signal as standard. The two local, easily readable, mechanical displays need no power supply and enable the simultaneous reading of the working and the differential pressure. Furthermore, this saves on an additional measuring and sealing point, reducing additional expense for piping and mounting. The robust aluminium case and shatterproof window enable a long service life of the product, even under harsh ambient conditions. This ensures that there is no danger from the instrument and it is resistant to external mechanical impacts. The new and functional design completes the appearance of the measuring instrument. WIKA data sheet PV 17.19 12/2017 Page 1 of 5 Data sheets showing similar products: DELTA-plus, differential pressure gauge; model DPG40; see data sheet PM 07.20 DELTA-comb, differential pressure gauge with micro switches; model DPGS40; see data sheet PV 27.20 DELTA-switch, differential pressure switch; model DPS40; see data sheet PV 27.21

Design and operating principle Illustration of the principle Pressures p 1 and p 2 act on the media chambers and, which are separated by an elastic diaphragm (1). The differential pressure (Δp = p 1 - p 2 ) leads to an axial deflection of the diaphragm against the measuring range springs (2). The deflection, which is proportional to the differential pressure, is transmitted to the movement (4) in the indicating case via a pressure-tight and low friction rocker arm (3). A magnet (5), fixed to the rear of the movement, affects the electromagnetic field of the HALL sensor. The signal that results from this is converted to a standardised current output signal by the signal conditioning board (6). Overpressure safety is provided by metal bolsters (7) resting against the elastic diaphragm. Mounting according to affixed symbols, high pressure, low pressure 14077606.01 Mounting: Rigid measuring line Wall mounting with available mounting links Standard version Specifications Mechanical data Nominal size DELTA-trans model DPGT40 Differential pressure indication: Ø 100 mm Working pressure indication: Ø 22 mm Accuracy Differential pressure indication: 2.5 % of span (option 1.6 %) Working pressure indication: 4 % of span Scale ranges (EN 837) Max. working pressure (stat.) Overpressure safety Permissible temperature Differential pressure: 0... 0.16 to 0... 10 bar Working pressure: 0... 25 bar 25 bar Either side max. 25 bar Ingress protection IP65 per IEC/EN 60529 Ambient: -10... +70 C (Ex version: -10... +60 C) Medium: -10... +90 C Storage: -40... +70 C Media chamber (wetted) Aluminium, EN AC Al Si9Cu3(Fe), black lacquered (option: Stainless steel 1.4571) Process connections (wetted) Pressure elements (wetted) Transmission parts (wetted) Sealings (wetted) Movement Dial Pointer Zero adjustment for differential pressure indication Case Window Weight 2 x G 1/4 female, lower mount, in-line, centre distance 26 mm Differential pressure: Compression springs from stainless steel 1.4310 and separating diaphragm from FPM/FKM (option: NBR) Working pressure: Bourdon tube from Cu-alloy Stainless steel 1.4301, 1.4305, 1.4310, FPM/FKM (option: NBR) FPM/FKM (option: NBR) Copper alloy Differential and working pressure indication: White dial, black lettering Differential and working pressure indication: Blue pointer Via screw in the dial Aluminium, EN AC Al Si9Cu3(Fe), black lacquered Plastic, with plug screw for zero adjustment approx. 1.3 kg Page 2 of 5 WIKA data sheet PV 17.19 12/2017

Maximum values for the supply circuit (only Ex version) Parameters Instrument group II Potentially explosive gas atmosphere Potentially explosive dust atmosphere Terminal marking I+ and GND Voltage U i DC 30 V Current l i 100 ma Power P i 1 W 750 mw for -10 C Ta +40 C 650 mw for -10 C Ta +60 C Effective internal capacitance C i Effective internal inductance L i 17.5 nf Negligible Electrical data Power supply U B DC 12 V < U B 30 V (variant 1 + 3) DC 14 V< U B 30 V (variant 2) DC 15 V < U B 30 V (variant 4) Influence of power supply Permissible residual ripple 0.1 % FS/10 V 10 % ss Output signal 4 20 ma, 2-wire, passive, per NAMUR NE 43 (variant 1) 4 20 ma, 2-wire, Ex version (variant 2) 0... 20 ma, 3-wire (variant 3) 0... 10 V, 3-wire (variant 4) Permissible max. load R A (variant 1-3) Effect of load (variant 1-3) Electrical zero point R A (U B - 12 V)/0.02 A with R A in Ω and U B in V, however max. 600 Ω 0.1 % FS Long-term stability of electronics < 0.3 % FS/a Electr. output signal 2.5 % of span (option 1.6 %) Linear error Electrical connection Through a jumper across terminals 5 and 6 (see operating instructions) 2.5 % of span (option 1.6 %), terminal method Via angular connector, 180 rotatable, wire protection, cable gland M20 x 1.5, incl. strain relief, connection cable: Outer diameter 7... 13 mm, conductor cross-section 0.14... 1.5 mm 2, temperature resistance up to 70 C Wiring protection Angular connector: IP65 per IEC/EN 60529 Assignment of terminals, 2-wire (variant 1 and 2) 1) Do not use this terminal U B +/I+ Terminals 3 and 4: For internal use only Terminals 5 and 6: Reset zero point 0 V/GND 1) For 3-wire connection see operating instructions Options Without working pressure indication Scale range for working pressure 0... 10 or 0... 16 bar (max. working pressure and overpressure safety up to 10 or 16 bar) Accuracy class 1.6 for differential pressure indication with scale ranges 0... 1 bar to 0... 10 bar 4-way manifold from Cu-alloy or stainless steel (1 x pressure compensating, 2 x shut-off, 1 x for purging and ventilating) Sealings (model 910.17, see data sheet AC 09.08) Other process connections for female and male threads Compression fittings with ferrule or clamp ring for pipe diameters 6, 8 and 10 mm Panel mounting flange (available in 2 versions: Stainless steel or stainless steel, black lacquered) WIKA data sheet PV 17.19 12/2017 Page 3 of 5

Dimensions in mm 14078303.01 Option Panel mounting Option 4-way manifold Pressure compensating Vent Cutout Panel 14078276.01 Shut-off side Shut-off side 2261821.04 Page 4 of 5 WIKA data sheet PV 17.19 12/2017

Approvals Logo Description Country EU declaration of conformity Pressure equipment directive Low voltage directive RoHS directive ATEX directive (option) European Union - Ex i Zone 1 gas [II 2G Ex ia IIC T4... T6 Gb] Zone 21 dust [II 2D Ex ia IIIB T135 C Db] IECEx (option) - Ex i Zone 1 gas [Ex ia IIC T3... T6 Gb] Zone 21 dust [Ex ia IIIB T135 C Db] EAC (option) EMC directive Pressure equipment directive Low voltage directive GOST (option) Metrology/measurement technology KazInMetr (option) UkrSEPRO (option) Uzstandard (option) - CRN Safety (e.g. electr. safety, overpressure,...) International Eurasian Economic Community Russia Kazakhstan Ukraine Uzbekistan Canada Certificates (option) 2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing, indication accuracy) 3.1 inspection certificate per EN 10204 (e.g. indication accuracy) Approvals and certificates, see website Ordering information Model / Scale range / Process connection / Material of separating diaphragm and sealings / Output signal / Options 2014 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. 12/2017 EN WIKA data sheet PV 17.19 12/2017 Page 5 of 5 WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de