GRUNDFOS DATA BOOKLET. Control HVAC. For variable-primary-flow systems

Similar documents
GRUNDFOS INSTRUCTIONS. Control HVAC. Installation and operating instructions. Other languages. net.grundfos.com/qr/i/

GRUNDFOS DATA BOOKLET. Hydro Multi-B. Booster systems with 2 or 3 pumps. 50/60 Hz

Grundfos Direct Sensors

GRUNDFOS DATA BOOKLET. Hydro Multi-B. Booster systems with 2 or 3 pumps 60 Hz. Drinking Water System Component NSF / ANSI 61 NSF / ANSI 372

GRUNDFOS DATA BOOKLET. Fire NKF. Grundfos fire systems. Fire pump sets with electrically and diesel-powered pumps according to DBI 251/CEA4001

OPTIMUM PERFORMANCE AND APPLICATION FIT

HYDRO BOOSTER RANGE HYDRO MULTI-S HYDRO MULTI-B CME HYDRO MULTI-B CR HYDRO MPC

grundfos INSTRUCTIONS BMS/ BMST/ BMSX High pressure and reverse osmosis systems

Note! Product picture may differ from actual product

GRUNDFOS DATA BOOKLET. Self-priming multistage pumps 50 Hz

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

NB80-160/161 A-F2-A-BQQE

CMBE Booster. Lenntech. Description 50/60 Hz. Horizontal, multistage centrifugal boosters

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete booster systems 50/60 Hz

Grundfos Direct Sensors

Company name: Created by: Phone: Date: Note! Product picture may differ from actual product

Company name: Created by: Phone: Note! Product picture may differ from actual product

GRUNDFOS DATA BOOKLET. Grundfos RSI. Renewable solar inverter for pump control kw

NBE50-250/205 A-F2-A-BAQE

Grundfos Home Booster

GRUNDFOS INSTRUCTIONS. Hydro MPC. Installation and operating instructions

CRE20-08 A-F-A-E-HQQE 3x HZ

CRE A-F-A-E-HQQE 3x HZ

Renewable Solar Inverter, RSI

CRNE15-12 A-FGJ-G-V-HQQV 3x HZ

GRUNDFOS INSTRUCTIONS. Hydro MPC. Installation and operating instructions

Renewable Solar Inverter, RSI

MGE MOTORS kw

CRE5-16 A-A-A-E-HQQE 3x400 50HZ

CRNE AN-F-G-E-HQQE 3x HZ

TPED /4-A-F-A-BQQE 3X400 50HZ

NBE40-125/139 AS-F2-A-BAQE

GRUNDFOS DATA BOOKLET NS, PF. 50 Hz

CRE15-01 A-F-A-E-HQQE 1x HZ

CRE10-02 A-A-A-E-HQQE 1x HZ

TPED /4-S-A-F-A-BAQE 3X400 50HZ

CRNE5-10 A-FGJ-G-E-HQQE 3x400 50HZ

GRUNDFOS MGE MOTORS kw MGE MOTORS kw. Lenntech. Tel Fax.

GRUNDFOS DATA BOOKLET. Grundfos CUE. Frequency converters for pump control. 50/60 Hz

Company name: GSI Created by: Xiao Ying Wong Phone: Date: 10/03/2017 Client: Client Number: Contact:

TPE S-A-F-I-BQQE

Service instructions. MAGNA Series 2000

GRUNDFOS DATA BOOKLET TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D. In-line circulator pumps. 50 Hz. Lenntech

Hydro MPC-E 3 CRIE5-9 U1 A-A-A-GH GNL

GRUNDFOS DATA BOOKLET. Oxiperm OCD to 2000 g/h. Preparation of chlorine dioxide from diluted solutions

CRE10-12 AN-FJ-A-E-HQQE 3x HZ

GRUNDFOS DATA BOOKLET. Self-priming. 50/60 Hz

Pumping station systems

TPE /2 B U-G-Z-BUBE

BoosterpaQ - Hydro MPC

GRUNDFOS PRODUCT GUIDE. Grundfos CUE. Frequency converters for pump control 60 Hz

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

TPE /2 U-G-A-BUBE

TPE S-A-F-A-BUBE

TPE /2-S-A-F-A-BAQE 3X400 50HZ

TPE /2 U-G-A-BUBE

Accutrol, LLC Product Sheet AVC6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

BROCHURE. Low voltage AC drives ABB general purpose drives ACS580, 1 to 350 hp

CME1-4 A-R-I-E-AQQE S-A-D-N

HVW701 HVAC Drive with By-Pass

Product brochure. Medium voltage AC drive ACS 2000, 4kV 6.9kV HP

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, p/n Revision 0

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E

GRUNDFOS INSTRUCTIONS. Hydro Multi-B. Installation and operating instructions

CME5-5 A-R-I-E-AQQE S-A-D-N

SECTION ELECTRONIC ACTUATED PRESSURE REDUCING VALVES AND ACCESSORIES

TPE 25-80/2-A-O-A-BUBE 1X230 50HZ

NKE80-160/175A2F2AE-SBQQE

SL B. Grundfos pump GRUNDFOS DATA BOOKLET

CRIE10-03 A-FGJ-I-E-HQQE 3x HZ

High-efficiency Drinking Water Pump. Rio-Eco Therm N. Type Series Booklet

Smart Products. Maxon Workshop Richard Reyes

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, P/N: , Revision 1

Constant Pressure Guaranteed Pressure boosting for water supply in commercial buildings

Acid Resistant AVC6000

Lenntech GRUNDFOS DATA BOOKLET. CME 15. Horizontal, multistage centrifugal pumps 50/60 Hz

TPE /4-A-F-A-BAQE 3X400 50HZ

2.7. IT system floor-standing distribution cabinet Series -IPS-F

BT300 Variable Frequency Drives. Redesigned, re-tooled, and ready to meet rigorous demands.

TPE N-A-F-A-GQQE

Ucontrol. 1 Data sheet. Multipurpose controllers for variable voltage 3 ~ fans PXDM Examples of application. 1.2 Equipment / Function

SOLAR PUMPING SOLUTIONS

BoosterpaQ - Hydro MPC

Accutrol, LLC Product Sheet AVT6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Improves fan ef ciency

GRUNDFOS DATA BOOKLET. CHV booster. Hydro Pack, Hydro Dome 50 Hz

Grundfos pressure boosting systems

Multilift M, MD, MDV, and MD1 ranges

GRUNDFOS DATA BOOKLET. Hydro Multi-E. Booster systems with 2 to 3 CRE pumps 60 Hz

TPE N-A-F-I-BUBE

Variable Speed Product Line

DDA AR-PVC/V/C with access.

Company name: Created by: Phone:

Grundfos pump

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Actual-position Feedback Unit. SISTO-SK-i. For Valves with Linear Actuators Stroke: 5-46 mm. Type Series Booklet

GRUNDFOS PRODUCT GUIDE. BoosterpaQ Hydro MPC. Booster sets with 2 to 6 pumps 60 Hz

Ventilation in balance

CRE20-03 A-A-A-E-HQQE 3x HZ

TPE N-A-F-A-GQQE

Transcription:

GRUNDFOS DATA BOOKLET Control HVAC For variable-primary-flow systems

Control HVAC Table of contents 1. Product description 3 Introduction.................................................................................. 3 Applications.................................................................................. 3 Benefits..................................................................................... 4 Features..................................................................................... 4 Energy-optimised control........................................................................ 5 2. Construction 6 Main cabinet.................................................................................. 6 Subcabinets.................................................................................. 6 3. System configuration 7 Pumps...................................................................................... 7 Bypass valve................................................................................. 7 Sensors..................................................................................... 7 4. Installation 8 Location..................................................................................... 8 Mechanical installation.......................................................................... 8 Electrical installation........................................................................... 8 5. Control functions 9 Operating modes.............................................................................. 9 System monitoring............................................................................. 9 6. Product range 10 Type key................................................................................... 10 Options..................................................................................... 10 7. Technical data 11 Inputs and outputs............................................................................ 11 Dimensions................................................................................. 11 Materials................................................................................... 11 8. Accessories 12 DPI V.2 differential-pressure sensor.............................................................. 12 M12 cable.................................................................................. 12 Capillary tube................................................................................ 12 VFI vortex flow sensor......................................................................... 13 TTA temperature sensor....................................................................... 13 2

Control HVAC 1 1. Product description Introduction The Control HVAC is designed to optimise pump operation in a variable-primary-flow system being part of an air-conditioning system. The controller controls speed-controlled pumps and a bypass valve positioned between the flow and return pipes of the air-handling zones. According to the demand of the air-handling zones, the controller operates the pumps in the most efficient way. Additionally, when the demand is low, the controller adjusts the opening of the bypass valve to ensure a minimum flow through the operating chillers. The controller can handle up to eight pumps, eight chillers and 26 air-handling zones. Applications The Grundfos Control HVAC is suitable for new as well as existing systems in large buildings, such as: airports large hotels office buildings shopping malls hospitals universities. Product description CHILLER ZONE T T CHILLER ZONE F CHILLER ZONE Up to eight pumps Up to eight chillers Up to 26 zones M T TM062783 4614 Fig. 1 Example of a variable-primary-flow system with three pumps, three chillers and three air-handling zones Pos. Description Pos. Description Pos. Description T M Temperature sensor Bypass valve CHILLER Chiller F Flow sensor Isolating valve ZONE Air-handling zones: air-handling units, fan coils, etc. Differential-pressure sensor Speed-controlled pump 3

1 Control HVAC Product description Benefits Energy-optimised control Supply-to-demand philosophy. Reduced energy consumption without compromising comfort. Pumps are connected in parallel and operate in the most efficient way. Can handle up to eight pumps, eight chillers and 26 air-handling zones, e.g. the most critical zones. Bypass valve ensures minimum flow through chillers. High quality High system stability durability. Simplicity Intuitive user interface easy commissioning easy system configuration easy integration into any building management system (BMS) standard-packaged system. Features Control Designed for variable-primary-flow systems speed and cascade control of pumps two operating modes for the system: Auto/Remote Manual/Local. three operating modes for pumps: Auto Manual Off. two operating modes for the bypass valve: Auto Manual. Hardware Main cabinet with user interface subcabinets for additional air-handling zones inputs for flow, differential-pressure and temperature sensors alarm outputs. User interface 7" colour touchscreen selector switches for system and pumps. Remote management (optional) Possible integration into building management and SCADA systems via standard protocols BACnet IP and Modbus TCP possible integration with Grundfos Remote Management (GRM). 4

Control HVAC 1 Energy-optimised control Grundfos Control HVAC is designed to optimise pump operation, regardless of the demand of the airhandling zones. Chillers can only operate correctly within a specific flow range. Using the bypass valve, the controller ensures that this requirement is met at all times. System requirements In order for the Control HVAC to operate correctly, the following requirements must be met: Pumps, chillers and air-handling zones must be connected in parallel. The pump system must have a differential-pressure sensor. Each chiller must have a differential-pressure sensor. At least one differential-pressure sensor must be placed between the inlet and outlet of all the zones. Up to 26 differential-pressure sensors can be placed in critical zones in the system. Isolating valves with an electric contact must be placed at the outlet of every chiller. A bypass valve must be placed between the flow and the return pipes of the zones. System control The air-handling zones, chillers and isolating valves must be controlled by an external building management system. The Control HVAC controls the pumps and the bypass valve based on the feedback from the sensors and chiller isolating valves. The cooling load of the air-handling zones determines the number of chillers in operation. According to the number of chillers in operation, the controller adjust the pump operation to maintain a differential pressure or flow rate across the chillers within the permissible range. The controller then adjusts the pump operation further in order to meet the demand of the air-handling zone with the highest differential pressure, or in other words, with the highest flow rate. If the flow rate is lower than the minimum flow rate required through the chillers, the controller opens the bypass valve and thus maintains a minimum flow rate across the chillers. Pump cascade control The Control HVAC is designed to control Grundfos E- pumps and CUE frequency converters, as well as other types of pumps with variable frequency drives (VFD). The performance is adjusted to the demand through cutting pumps in or out and through parallel control of the pumps in operation. The Control HVAC maintains a constant differential pressure through continuous adjustment of the speed of the pumps. Pump changeover is automatic and depends on load, operating hours and fault. All pumps in operation run at the same speed. The number of pumps in operation also depends on the energy consumption of the pumps. If only one pump is required, two pumps will run at a lower speed if this results in a lower energy consumption. Examples of operation with one and with three E- pumps: H H set Fig. 2 H H set Fig. 3 One E-pump in operation Three E-pumps in operation Bypass valve control The Control HVAC takes the characteristics of the bypass valves into account when controlling the valve position. This ensure smooth and accurate adjustment of the valve at all times. Q Q TM00 7995 2296 TM00 7996 2296 Product description 5

2 Control HVAC Construction 2. Construction Main cabinet The main cabinet hosts the controller, the user interface and the input and output terminals for the pumps, bypass valve, sensors, etc. Terminals The main cabinet is equipped with terminals which are connected to all the devices of the system. The terminals have status indicator lights. For more information, see section Technical data, page 11. Fig. 4 Front panel of the main cabinet Front panel with touchscreen The front panel of the cabinet hosts the controller, which has an embedded 7" colour touchscreen. It allows the user to configure the system and to monitor and control the operation. TM063855 1115 Selector switches The front panel of the cabinet is equipped with the following selector switches: 1 for the system: Remote Local Off. 1 for the power supply: On Off. 1 for each pump: Auto Manual Off. Subcabinets When more than two air-handling zones are to be connected to the controller, up to three subcabinets supporting eight air-handling zones each can be connected to the main cabinet via an EtherCat cable. TM063854 1115 Fig. 5 Controller and touchscreen 6

Control HVAC 3 3. System configuration Pumps The Control HVAC is designed for Grundfos E-pumps, Grundfos pumps with a CUE frequency converter and other pumps with a 0-10 V variable frequency drive. The following Grundfos pumps are compatible with the Control HVAC: end-suction pumps: NK, NKE, NB, NBE vertical in-line volute pumps: TP, TPE horizontal split case pump: HS, KP, LS. System configuration Bypass valve As standard, the Control HVAC requires a bypass valve with a control signal of 4-20 ma. On request, the Control HVAC can be adapted for a bypass valve with a control signal of 0-10 V. The Control HVAC has an input for feedback of the bypass valve position. Sensors Pump sensor The pump system requires a differential-pressure sensor with a signal of 4-20 ma. We recommend the Grundfos differential-pressure sensor, type DPI V.2. Chiller sensors The chillers require a differential-pressure sensor with a signal of 4-20 ma. We recommend differential-pressure sensors with a short response time such as the Grundfos differentialpressure sensor, type DPI V.2. Sensors for air-handling zones The zones require differential-pressure sensors with a signal of 4-20 ma. We recommend the Grundfos differential-pressure sensor, type DPI V.2. Flow sensor An additional flow sensor with a signal of 4-20 ma can be placed in the system and monitored via the controller screen. The calculation of the specific energy requires a flow sensor. We recommend the Grundfos vortex flow sensor, type VFI. Temperature sensors Two temperature sensors with a signal of 4-20 ma can be placed in the system and monitored via the controller screen. We recommend the Grundfos TTA sensor. For more information about Grundfos sensors, see section Product range, page 10 or productselection.grundfos.com. 7

4 Control HVAC Installation 4. Installation Location Main cabinet The main cabinet must be installed in a well-ventilated room to ensure sufficient cooling of its components. Note: The main cabinet is not designed for outdoor installation and must not be exposed to direct sunlight. Subcabinets The subcabinets must be installed in a well-ventilated room to ensure sufficient cooling of the system. They must be installed at maximum 100 metres (328 feet) from the main cabinet. Note: The subcabinets are not designed for outdoor installation and must not be exposed to direct sunlight. Mechanical installation The main cabinet and subcabinets can be mounted on a wall. Electrical installation The electrical installation must be carried out by authorised staff in accordance with local regulations and the wiring diagram supplied with the product. The electrical installation must be according to enclosure class IP54 (UL type 1). The voltage and frequency of the power supply for the Control HVAC must correspond to the model delivered. The devices of the system connect fast and easily to the terminals in the cabinets. 8

Control HVAC 5 5. Control functions Operating modes In automatic mode, the system operates according to the signals from the sensors, chillers, pumps and the bypass valve. For maintenance or fault-finding purposes, it is, however, possible to control the system, pumps and valve manually from the controller, or to disconnect them individually from the controller. Pumps The operating mode of each pump can be set to "Manual", "Auto" or "Off" by means of selector switches on the main cabinet. Mode Auto Manual Off Description The pump is controlled by the internal pump controller and runs as part of the pump cascade system. The pump runs according to the settings made on the touchscreen. It can either start at a selected speed or stop. The pump is not controlled by the internal pump controller and therefore runs independently of the pump cascade system. The pump is switched off. The pump cannot be started via the touchscreen nor by a building management system. System The operating mode of the system can be set to "Remote", "Local" or "Off" by means of a selector switch on the main cabinet. Mode Auto/Remote Manual/Local Off Description The system operates according to the data collected by the controller. It can be controlled and monitored via the Grundfos Remote Management or a building management system. The communication to the Grundfos Remote Management or a building management system is deactivated. The controller operates according to the setting made on the touchscreen. The user can set a manual setpoint for the pump system and can stop the pump system. The controller is switched off. It cannot be activated via the touchscreen nor by a building management system. Note: The touchscreen is still on, and settings can be changed. Bypass valve The control of the bypass valve can be set to "Auto", "Manual" or "Off" on the touchscreen. Mode Auto Manual Off Description The valve is controlled by the controller. The valve is not controlled by the controller, and its position can be changed manually via the touchscreen. The valve cannot be controlled by the controller. Fault indications The Control HVAC can show the following fault indications: sensor fault valve fault pump fault controller fault communication fault (between main cabinet and subcabinets). System monitoring To facilitate monitoring and testing of the system, the touchscreen shows information about each device connected to the controller. Pumps Status: on, off or fault speed as percentage of maximum speed reference pressure of the pump system specific energy. Chillers Status: on or off minimum differential pressure required across the chiller in focus, i.e. the one with the greatest deviation between the minimum differential pressure required and the actual differential pressure. differential pressure measured across the chiller in focus. Air-handling zones Differential pressure of each zone reference differential pressure of the zone in focus, i.e. the one with the highest differential pressure differential pressure measured across the zone in focus. Bypass valve Position as percentage of maximum opening angle. Temperature Temperature at the pump system outlet temperature at the chiller outlet temperature at the zone outlet. Flow rate Flow rate at the pump system outlet. Note: Monitoring of temperature and flow rate requires sensors in the system. Control functions 9

6 Control HVAC Product range 6. Product range Designation Product number Kit, HVAC, VPF 4, GENI 98899279 Kit, HVAC, VPF 4, VFD 98899391 Kit, HVAC, VPF 8, GENI 98899395 Kit, HVAC, VPF 8, VFD 98899396 Description Controller for 1-4 Grundfos E-pumps or pumps with a Grundfos CUE frequency converter Controller for 1-4 pumps with a variable frequency drive Controller for 5-8 Grundfos E-pumps or pumps with a Grundfos CUE frequency converter Controller for 5-8 pumps with a variable frequency drive Type key Example: Control HVAC 3x 0-13 3x380 Type 3R OPT Type range Number of pumps (2x - 8x) Current range of pumps in Ampere [A] Supply voltage Panel type: 3R (UL) or IP54 (IEC) OPT: Optional equipment. See the nameplate for details. Options 0-10 V control and feedback of bypass valve position All standard models are equipped with a 4-20 ma terminal for the control and feedback of the bypass valve position. Optionally, it can be ordered with a 0-10 V terminal. See section Subcabinets, page 6. Data communication The Control HVAC can be monitored and controlled by Grundfos Remote Management using GENIbus communication. It can also support other types of building management systems using BACnet IP and Modbus TCP. This option must be ordered with the Control HVAC as it is configured during production. Grundfos Remote Management requires a separate contract with Grundfos which hosts the Grundfos Remote Management database and servers. Selector switches for pumps All standard models are equipped with selector switches for pumps on the front panel. See section Selector switches, page 6. On request, it can be ordered without pump selector switches. In this case, the default pump operating mode is "Auto". Subcabinet Product name Product number Kit set extension, IO 98913800 10

Control HVAC 7 7. Technical data Inputs and outputs The main cabinet has the following inputs and outputs. Type Signal Connection Comments Differential-pressure sensors of pumps Differential-pressure sensors of chillers Differential-pressure sensors of the first two zones Dimensions Width Height Depth [mm] [inch] [mm] [inch] [mm] [inch] Main cabinet 600 23.63 600 23.63 250 9.84 Subcabinet 380 14.96 380 14.96 210 8.26 Materials The main cabinet and subcabinets are made of powder-coated steel. Technical data 4-20 ma Temperature sensors Option Analog inputs Feedback of bypass valve position Flow sensor Option Feedback of VFD power consumption VFD model 0-10 V Feedback of bypass valve position Feedback of VFD power consumption Option Option for VFD model 4-20 ma Control signal for bypass valve Analog outputs 0-10 V Control signal for VFD Control signal for bypass valve VFD model Option On/off switch Selector switch for pump operating mode: Auto, Manual, Off. Digital inputs Selector switch for system operating mode: Remote, Local, Off. Status of chiller isolating valve: open/closed, i.e. chiller on/off VFD status: ready, on/off, fault VFD model External emergency switch for system External emergency switches for pumps Start/stop of VFD VFD model Digital outputs Alarm signal (BMS) System status on/off (BMS) RS 485 interface GENIbus from Grundfos E-pumps or CUE frequency converter GENIbus model RJ45 LAN 1 GRM, Modbus TCP, BACnet IP Option RJ45 EtherCAT Subcabinets More than two zones 11

8 Control HVAC Accessories 8. Accessories DPI V.2 differential-pressure sensor Features Compact design MEMS technology standard M12 connector. Fig. 6 DPI V.2 sensor Technical overview The differential-pressure sensor, type DPI V.2 from Grundfos Direct Sensors, is designed for industrial purposes and to be mounted directly on the unit, for example a pump. The DPI V.2 is used together with a capillary tube in order to measure the differential pressure between two points of the system. The DPI V.2 sensors are fully compatible with wet, aggressive media. They use MEMS sensing technology in combination with the Silicoat corrosionresistant coating technology on the sensor chip. This makes the DPI sensors very robust and ideal for pump integration and monitoring in harsh environments. Benefits Compatible with wet, aggressive media accurate, linearised and temperature-compensated output signal cost-effective and robust design system solution with Grundfos pumps. TM04 7866 2510 Pressure See the complete product range in the data booklet: http://net.grundfos.com/qr/i/97790251 M12 cable 4-wire screened cable with a M12 connector in the sensor end and an open end in the equipment end. Designation Cable, industry M2.000X Cable, industry M5.000X Capillary tube [bar] [psi] 0-0.6 0-8.7 0-1.0 0-14.5 0-1.6 0-23.2 0-2.5 0-36.3 0-4.0 0-58.0 0-6.0 0-87.0 0-10.0 0-145.0 0-16.0 0-232.1 Length 2 m (6.56 feet) 5 (16.40 feet) Product number 96841343 96841344 The capillary tube is used to connect a DPI, DPI V.2 or DPI+T, DPI V.2 +T sensor to the low-pressure side of the equipment. Designation Product number Capillary tube UNS 7/16" 00ID5225 12

Control HVAC 8 VFI vortex flow sensor Features Wide operating temperature range: -30 - +120 C (-22 - +248 F) compact design MEMS technology. Accessories Fig. 7 VFI sensor Technical overview The VFI sensor from Grundfos Direct Sensors is a flow sensor designed for industrial purposes. It is based on the principle of vortex shedding behind a bluff body. The VFI sensors are fully compatible with wet, aggressive media. They use MEMS sensing technology in combination with the Silicoat corrosionresistant coating technology on the sensor chip. This makes the VFI sensors very robust and ideal for pump integration and monitoring in harsh environments. The sensor is supplied with a stainless-steel flow pipe and has flanged or threaded ends for use with union nuts. Benefits No moving parts compatible with wet, aggressive media accurate, linearised and temperature-compensated output signal quick temperature response (direct contact with medium) cost-effective and robust design system solution with Grundfos pumps. TM04 7362 2210 Flow rate See the complete product range in the data booklet: http://net.grundfos.com/qr/i/97790189 For flow rates greater than 240 m 3 /h (1057 gpm), contact your local Grundfos sales company. TTA temperature sensor [m 3 /h] [gpm] 0.3-6 1.32-26.42 0.6-12 2.64-52.83 1.3-25 5.72-110.07 2.0-40 8.81-176.11 3.2-64 14.09-281.78 5.2-104 22.89-457.89 8-160 35.22-704.46 12-240 52.83-1056.69 The sensor is a Pt100 temperature sensor fitted into a measuring tube. The sensor is built into the system either by means of a cutting ring bush or by means of a protecting tube. Features 4-20 ma output measuring tube made of stainless steel DIN 1.4571 sensor built into a type B connection head (DIN 43729) made of painted pressure-diecast aluminium with a Pg 16 screwed connection optional protective tube with G 1/2 connection. Contact your local Grundfos company for product range. 13

98800761 0915 ECM: 1167474 The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide. Copyright Grundfos Holding A/S GRUNDFOS A/S DK-8850 Bjerringbro. Denmark Telephone: +45 87 50 14 00 www.grundfos.com