CM707 (UK Version) PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Similar documents
CM707 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

TheraPro HR90 ELECTRONIC RADIATOR CONTROLLER OVERVIEW MAIN FEATURES PRODUCT DATA SHEET

DS DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL

HERZ Electronic room thermostat analog and digital

VisionPRO 8000 Thermostats

TIMER INTERFACE USER MANUAL

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

Installation Guide. ECL Comfort 210 / 310, application A231 / A Table of Contents

KCR1. Kiln Controller Handbook. Kilncare Ltd. The Kiln Works 907 Leek New Road Baddeley Green Stoke-on-Trent Staffordshire, ST2 7HQ United Kingdom

Cooling mode. Temperature adjustment button. Override button. 24 VAC COM AN1 COM OPEN CLOSED T2/AN2 T2/COM T3 T3 COM SENSOR COM C-Over COM NSB

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Digital Room Thermostats with Touch Screen LCD

MC200CAB/4 Integral Version

Fan Coil Thermostat. Specification & Installation instructions TFC54F3X1. Technical Data

USER GUIDE Digital Thermostat GUIDE D UTILISATION Thermostat digital Bedienungsanleitung Termostato digital 50-72

User Manual. Solar Charge Controller 3KW

PROPORTIONAL BAND ZERO ENERGY BAND DEFINITION S1 S2

AUTOMATIC 12 WAY HEAT TREATMENT CONSOLE

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

Opening hours Monday - Friday, 8.00am pm Weekends and Bank Holidays, 8.30am pm We are closed on Christmas Day and New Year s Day.

Programming Guide. Futura Spas TMTM. in.k300. in.k300. the essential spa keypad. Bright LCD screen Spa function icons. Spa function icons.

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

PowerView PV380-R2 Mechanical Configuration

Digital Time Switches

LK Control v.3 & LK Control v.3 - RA

User Manual Solar Charge Controller 3KW

OPTOTRONIC Programmable LED Emergency Driver and Battery Pack

Product Data. SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control. EVOLUTION r CONNEX t CONTROL

Digital Room THERMOSTAT for Model No. RT300

USERS MANUAL MCD REMOTE OPERATOR

AGA Oil to Electric Conversion kit with AIMS (AGA INTELLIGENT MANAGEMENT SYSTEM)

Garden Thermometer with Solar Lighting

Features and Benefits. Control Features

Product Data. SYSTXCCITC01---B Infinityr System Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR SYSTEM CONTROL

HEAVY DUTY POWER RELAYS FEATURES

AT EVO SERIES BATTERY CHARGER

2011 International Comfort Products, LLC

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

EVO AT SERIES BATTERY CHARGER

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.

AC Induction Motor Controller with VCL

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

ECL Comfort Installation and Maintenance. User s Guide. ECL Comfort. C60 Double mixing controller C60. Table of Contents. Daily use.

The next generation of controllers and valves

Electro Controls. Temperature Controllers WattsIndustries.co.uk

ZonePlus Z322 zone valve Installation and commissioning instructions

The Ultracom Range High Efficiency Condensing Boilers A guide for homeowners

Product Data. SYSTXBBECC01-B Evolutionr Connext Control INDUSTRY LEADING FEATURES/BENEFITS. EVOLUTION r CONNEX t CONTROL

CHOOSE TOSAVE. Take control of your electric bill by choosing the pricing plan that is right for you. Time-of-Use. Peak Demand. Demand Time-of-Use

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

MiG2 TIME SWITCHES. 1, 2 & 4 Channel, 365 Day, Energy Saving Time Switches

Wireless Digital Room Thermostat with Night Set-Back

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

ATevo SERIES BATTERY CHARGER

WP37 & HT37 User Manual

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

Transfer switch GTEC open or delayed transition

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

BROCHURE. ABB drives for HVAC applications ACH550, 1 to 550 Hp

Submittal Data Information

NoMAX 900 SERIES. Instruction SWITCHED CAPACITOR CONTROLS

RDG160TU Commercial Thermostat

Three axis ( X, Y, Z ) electromagnetic field measurement 3 D EMF TESTER. Model : EMF-828

24HR 30A SPST TM SW. Features. Long Description

AT SERIES EVO BATTERY CHARGER

The Baxi GA Combi & System Boiler Range

EMF TESTER OPERATION MANUAL. ELECTROMAGNETIC FIELD RADIATION TESTER Model : EMF-832

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

RVS-DN Digital Reduced Voltage Motor Starter

P od o u d c u t line n : S B S B Inv n erter N I P P r P esent n ation

MEGA WAY LCD PAGER ALARM WITH REMOTE ENGINE STARTER. Operation Manual MEGATRONIX CHATSWORTH, CA U.S.A. MEGA 2700 OPERATE 1

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

ABB Component Drives ACS150, 0.5 to 5 Hp

TECHNICAL INFORMATION

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Pivotell Advance Automatic Pill Dispenser Instructions

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

RVD120 RVD G2510. Installation. Place of installation. Electrical installation. Permissible cable lengths

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

Gate & Door Controller with LCD and Intelligent Technology

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor

RVS-DX Digital Reduced Voltage Motor Starter

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

LF Series At A Glance

EXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

i n s t r u c t i o n m a n u a l

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Operating principle Application diagram. Regulator-actuator Wiring diagrams

ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES

EFFICIENT SLEEPER COMFORT. Volvo s Battery-powered Parking Cooler Option

RC-DO. Room controllers with display and manual forced ventilation function

Transcription:

CM707 (UK Version) PROGRAMMABLE THERMOSTAT PRODUCT SPECIFICATION SHEET The CM707 thermostat is designed to provide automatic time and temperature control of heating systems in villas and apartments. It can be used as part of a system in conjunction with combiboilers, oil-burners and gas fired boilers, circulation pumps, thermal actuators, zone valves and electric heat systems (<5A). The CM707 is designed with the installer in mind and includes a moulded back-plate with trunking guides and wiring breakouts to make installation quick and easy. The CM707 large LCD display, button layout based on the same simple programming philosophy used on our acclaimed CM20 products and the introduction of an OK button makes it easier to install and more user friendly. The unit is ideal for consumers who want reliable precise temperature control from a modern looking, simple to program and easy to use product. FEATURES Attractive slim, modern styling makes it ideal for location in any type of home. 7 day heating program. Up to 4 daily independent time and temperature level changes let you set 4 time and temperatures pairs to suit your lifestyle. LCD Backlighting to illuminate the display for easier viewing in low light conditions. Temporary programmed temperature override to temporarily override the programmed temperature till the next switch point. Holiday button provides energy savings by reducing the temperature from to 99 days when people are on holiday, returning to normal operation (AUTO or MANUAL) on the day of their return. Room Enquiry. EEPROM memory holds the user program indefinitely. OFF mode has an integral frost protection setting at minimum 5 C (installer adjustable) so that pipes in the house will never freeze in winter. 24...230V 5A resistive, 2A inductive SPDT relay provides compatibility with most domestic central heating systems reducing the need to stock many different models. Battery powered by 2 x AA size (LR6) alkaline cells. Minimum battery life of 2 years with low battery warning indicator. Built-in default heating program. Automatic Summer / Winter time change adjusts the time automatically to daylight saving time. Scheduled Maintenance Alert Period. Surface or wall box mounting options, with trunking guides and wiring breakouts to simplify installation. No installer links or special installer switches on the back of the unit mean no adjustment is required for combi-boilers and most domestic central heating systems. User Set-Up Mode allows extra functions to be set at the discretion of the user: AM-PM or 24hr time display. Resetting the heating profile to factory default. Enable / disable of Auto Summer / Winter time change. Installer Set-Up Mode allows extra functions to be set at the discretion of the installer to match the consumers applications and needs: Optimisation. Pump Exercise. Upper / Lower Set point Adjust. offset. Minimum ON time. Cycle rate. Proportional Band Width. Diagnostic Mode to assist in fault finding.

CONTROLS/ DISPLAY LAYOUT PRODUCT LAYOUT:. LCD Screen 2. Battery Low Indicator 3. Time Display 4. Burner On Indicator 5. Day Indicator 6. Display 7. Change Buttons 8. Information Enquiry Button 9. Operating Mode Buttons 0. Green OK Button. Battery Compartment 2. Battery Cover 3. Holiday Function Button 4. Program Buttons 5. Copy Day Button 6. Date / Day Select Button 7. Time Change Buttons SPECIFICATIONS Batteries Battery life Battery replacement Switch type Electrical rating Time display Time keeping accuracy Program Time setting resolution : 2 x.5 V IEC LR6 (AA) Alkaline cells : Minimum 2 years : Program retained in EEPROM : SPDT (potential free) : 230 V~, 50...60 Hz, 0. A to 5 A resistive 0. A to 2 A inductive (0.6 pf) 24 V~, 50...60 Hz, 0.5 A to 5 A resistive 0.5 A to 2 A inductive (0.6 pf) : 24 hour or 2 hour AM/PM format : Typically better than 0 minutes per year : 7 day with 4 daily time and temperature level changes : Time of day - minute Program - 0 minute steps Sensing element : 00K (@ 25 o C ) NTC thermistor setting range : Program : 5 to 35 o C in 0.5 o C steps Frost : 5 o C or equal to lower limit (5 o C to 2 o C). control accuracy Room display range Control form Minimum ON time Cycle rate Wiring Wire access : ±0.5 K (nominal) @ 20 o C, 50% load 3 K Δ/hour : From 0 o C to 50 o C : P + I (Proportional + Integral) : 0% of cycle time (min one minute), adjustable to 2 to 5 min (see installer set up) : Selectable by application (see installer set up) : Terminal block capable of accepting wires up to 2.5 mm 2 : Mains wiring rear right. Low voltage wiring rear right. Dimensions : 33 x 88.5 x 26 mm (w x h x d) 33 x 75 x 26 mm (w x h x d) (flap open) Environmental Approvals : Operating temperature range 0 to 40 o C Shipping and storage temperature range -20 to 55 o C Humidity range 0 to 90% rh, noncondensing : Designed to meet European EN approvals EN60730-(Nov 2000), EN5504- (997), EN5504-2 (2000) 2

INSTALLER SET-UP To enter the installer set-up mode: a) Press the OFF button. b) Press and hold the INFO i button and the two program buttons < > together. c) The unit will display the first parameter of installer parameter group category (from n. to n.9). d) Press the TEMP or buttons to change the factory setting. The display will flash indicating that a change has been made. e) Press the green OK button to confirm this change and the display will stop flashing. f) Press the + button to go to the next parameter. g) Press the program button > to go to category 2 in the Installer mode (from n. to n.5). h) To exit the installer mode, press the AUTO, MAN or OFF buttons. Abbreviated Set-Up Description e.g. Cl = Clock Format In Installer set-up we can: Set-up specific applications Enable special features Installer Set-up Number (Press + or - to change) e.g. = Clock Format Factory Setting or New Choice Press TEMP or to change e.g. 2 = AM/PM Format 24 = 24hr Format Specific Applications Setting What do you need to change? Cycle/ Hour Minimum ON time (in minutes) Note : a. To change Cycle/Hour, please go to parameter n. 2, category 2 in the installer set-up mode. b. To change Minimum ON Time, please go to parameter n., category 2 in the installer set-up mode. Heating Gas Boilers (<30KW) 6 No action required Oil Boiler 3 4. Set Minimum ON Time to 4 minutes. 2. Set Cycle/Hour to 3. Thermal Actuator 2 Set Cycle/Hour to 2. Zone valve 6 No action required. Electric heating (for applications <5A) 2 Set Cycle/Hour to 2. 3

Special Features Description What to do if we wish this feature Optimisation (Variable Start Time) Adaptive Intelligence recovery TM The thermostat will adjust the start time in the morning/afternoon so the desired temperature is reached by the start of the program period e.g. Time 7:00, Temp 2 o C. The thermostat will monitor the accuracy of the start up and use this information to modify the calculation for the following day by changing the ramp rate (initial 3 K/hr).The system will restrict the start time to a max of 2 hours. Note: Optimisation will not work in cooling mode. Set parameter n.8, category in the installer set-up mode to. AM-PM/ 24hr Display Change display format (default 24hr). Set parameter n., category in the installer set -up mode to 2. Pump exercise Upper Lower Offset Proportional Band Width Scheduled Maintenance Alert Period When enabled the Pump Exercise will switch the relay on for minute at 2:00 if the relay has not been switched on since 2:00 the previous day. While in Holiday mode the Pump Exercise feature, if enabled, will operate. The normal upper temperature limit of 35 o C can be reduced down to 2 o C to save the homeowner energy. Useful if the homeowner rents to tenants. The normal lower temperature limit of 5 o C can be increased up to 2 o C to protect the inhabitants from cold. Useful if the inhabitants include the elderly, children or disabled. If the thermostat is located in a hot/cold location and cannot be moved because of wiring then the measured/ displayed temperature can be adjusted by +/- 3 o C. Useful if the homeowner wants the reading to match another appliance temperature display. Can be adjusted up to 3 o C (default is.5 o C) to provide better temperature control (less overshoot). Useful for: a. Well insulated homes with over-sized heating systems. b. Air systems with fast response. Can be set to the required number of months between -48. After the specified number of months the Chronotherm will display SERVICE prompting user to arrange a maintenance call Set parameter n.5, category 2 in the installer set -up mode to. Set parameter n.6, category in the limit. Set parameter n.7, category in the limit. Set parameter n.2, category in the offset value. Set parameter n.3, category in the value. Set parameter n.9 in the installer set -up mode to the desired value. 4

Parameter Installer Set-Up Number / Abbreviation (Press + or - keys to select) Factory Setting Optional Setting Installer Set- Up Category Display Description Display/Setting Description (Press PROG keys < or > to select) Category : Thermostat Parameters AM-PM / 24hr Display :Cl 24 24 hr clock display 2 2 hr AM / PM clock display RESET Time / Program 2:rP Time / profile set to factory default Changes to 0 when one of the time/temp profiles are changed 0 Time / are as programmed To restore the factory profile set to Auto Summer/Winter Time Change 3:tC Auto Summer/Winter Time Change enabled 0 Auto Summer/Winter Time Change disabled LCD Backlighting 5:bL Backlighting enabled 0 Backlighting disabled Upper 6:uL 35 35 C Upper Temp. 2 to 34 2 C to 34 C adjustment in C steps Lower 7:LL 5 5 C Lower Temp. 6 to 2 6 C to 2 C adjustment in C steps Optimisation 8:Op 0 Optimisation disabled Optimisation enabled Offset 2:tO 0 No offset -3 to +3-3 C to +3 C adjustment in 0. C steps Proportional Band Width 3:Pb.5.5 C Proportional Band.6 to 3.0.6 C to 3.0 C adjustment in 0. C steps Scheduled Maintenance Alert Period 9:SP 0 Scheduled Maintenance Alert Period disabled 0 to 48 0 to 48 months adjustments in month steps Reset Parameters to Factory Defaults 20:FS All settings held are the factory defaults. Changes to 0 when one of the parameter values are changed 0 Settings are as modified above To restore the factory profile set to Category 2: System Parameters (You must press the > program key to enter this section) Minimum ON Time :Ot minute minimum ON time 2 to 5 2-2 minutes 3-3 minutes 4-4 minutes 5-5 minutes 2 Cycle Rate 2:Cr 6 6 cycles per hour (cph) for gas boilers, zone valves and fancoil 3, 9, 2 3-3 cph 9-9cph 2-2 cph 2 Pump Exercise 5 PE 0 Pump Exercise Pump Exercise Enabled 2 5

DIMENSIONS INSTALLATION LOCATION The CM707 thermostat is the control element of the heating system and, therefore, MUST be located in a position with good air circulation, at average room temperature and on an inside wall,.5 metres above the floor level. Do not position the CM707 thermostat near sources of heat (radiators, hot air vents, TV or lights), near doors or windows, or in direct sunlight. MOUNTING The CM707 thermostat can be mounted directly on the wall surface or on to an electrical wall box. WIRING The CM707 thermostat is designed for fixed wiring only and must be installed in accordance with the latest l.e.e. regulations. Ensure the wiring connection to the supply is via a fuse rated at no more than 5 amps and a Class "A" switch (having contact separation of at least 3 mm in all poles). IMPORTANT. The installer must be a trained service engineer. 2. Disconnect the power supply before beginning installation. 6

WIRING ORDERING SPECIFICATION Description Model Logo Literature Availability Spec Sheet 7-day programmable thermostat CMT707A029 Honeywell English Oct 06 ENOH8558 Honeywell Control Systems ed Newhouse Industrial Estate Motherwell ML 5SB United Kingdom http://europe.hbc.honeywell.com