Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

Similar documents
Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 85,0/68,0 93,5/74,8 130,23 400/ ,8 85,0/68,0 93,5/74,8 135,12

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 172,9/138,3 190,6/152,5 265,44 400/ ,8 172,9/138,3 190,6/152,5 275,4

TECHNICAL SPECIFICATIONS

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32

VOLTAGE HZ PHASE COS PRP KVA/KW LTP KVA/KW AMPERAGE A

Code: KOHLER KDW 1404 ZANARDI ATO 28-1VS/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 10,0/8,0 11,0/8,8 15,9

ENGINE MAKE MODEL CONTINUOUS POWER PERKINS 2206A-E15TAG2 STAND-BY POWER

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 102,6/82,1 113,0/90,4 157,32 400/ ,8 102,6/82,1 113,0/90,4 163,22

1 / Genset general description

1 / Genset general description

1 / Genset general description

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

Standby Amper VOLTAGE

Technical specification

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

GBW22Y. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GE.PK.022/020.SS+0_all

Standby Amper VOLTAGE

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GE.VO.360/325.SS+0_all

Standby Amper VOLTAGE

GSW35Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

HFW-85 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Standard soundproofing Powered by FPT_IVECO

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

Alpha SERIES LWA 10(A)*, LWA 15(A), LWA 20(A), LWA 27(A) 50 Hz; 1500 r/min; power outputs: kva 60 Hz; 1800 r/min; power outputs:

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

WPS20/S EP Series. Features:

,QGXVWULDO#*HQVHW. 3RZHU#5DWLQJ 4833#USP283#+] 4;33#USP293#+] 3ULPH 27.5kVA, 22.0kW 32.5kVA, 25.9kW 6WDQGE\ 30.0kVA, 24.1kW 35.5kVA, 28.

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

70 KW / 90 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Power kva 9,3 10 Power kw 9,3 10 Rated Speed r.p.m Standard Voltage V 240 Rated at power factor Cos Phi 1

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

WPS350/S EP Series. Features:

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

16 KW / 20 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set is manufactured in facilities certified to ISO Voltage kva kw kva kw Amp 400/

JCB Diesel Generator Technical Specifications G45QX. Electrical. Prime

60 KW / 75 KVA POWERED by

WPS100/S EP Series. Features:

JCB Diesel Generator Technical Specifications G31RX. Electrical. Prime

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

LWALR LIQUID COOLED LONG RUNNING GENSETS

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

P6000s 230V 50Hz #CONN #DPP

Large autonomy Safety Ease of handling Silent. 18,0/14,4 20,0/16,0 Yanmar 4TNE88PG. 18,5/14,8 19,6/15,7 Deutz F3M 1011 F

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

SIVASA Doosan Series. SD250 Technical Data

MSW Series P. Main applications: Construction Mobile Workshop Emergency stand-by (residential / industry) Island/Mains synchro (from 100kVA)

TPD2250H6.3 TECHNICAL DATA

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

30 KW / 40 KVA POWERED by

WPS60/S EP Series. Features:

130 KW / 165 KVA POWERED by

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

GMR - 67P 67P 09/05/2016 GMR - 067P

WPS250/S EP Series. Features:

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

18 KW / 18 KVA POWERED by

Standby Amper VOLTAGE

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

57 KW / 71 KVA POWERED by

WPS150/S EP Series. Features:

28 KW / 28 KVA POWERED by

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Transcription:

Genset with manual control panel. Image for guidance purposes. PRP CONTINUOUS POWER: LTP 30 kva STAND-BY POWER: 33 kva PRP Prime Power norma ISO 8528-1 LTP Limited Time Power norma ISO 8528-1 ENGINE ALTERNATOR MAKE MODEL MAKE MODEL FPT F32AM1A MECC-ALTE ECP 28-VL / 4 VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/230 50 3 0,8 30,0/24,0 32,5/26,0 46,97 Teléfono: +34 968 380 129 T: Phone: +31 +34 174968 51380 60879

ENGINE CHARACTERISTICS MAKE FPT MODEL F32AM1A General Data Power PRP (kwm) Power LTP (kwm) No. cylinders Cylinder capacity (L) Diameter per stroke (mm) Compression ratio Cooling system Injection Suction Series regulator Fly wheel coupling 28.50 31.50 4 3.20 99 x 104 17.00 LIQUID DIRECT NATURAL MECHANICAL 3-11,5" Lubrication system Oil capacity (L) Oil consumption (%) Min. alarm oil pressure (bar) 10.50 0.10 0.60 Ventilation system Air cooling flow (m 3 /h) Combustion air flow (m 3 /h) Max. back pressure for fan (mbar) 5040 112 20 Exhaust system Exhaust gas flow (m 3 /h) Exhaust back pressure (mbar) Temp. exhaust gases (ºC) 152 50 400 Electrical system VDC (V) Battery (Ah) Engine start-up (kw) 12 100 3 Teléfono: +34 968 380 129 T: Phone: +31 +34 174968 51380 60879

ALTERNATOR CHARACTERISTICS MAKE MODEL MECC-ALTE ECP 28-VL / 4 General Data Power PRP (kva) Power LTP (kva) Efficiency Alt. 3/4 % Efficiency Alt. 4/4 % No. Poles Voltage regulator No. wires Insulation Xd (%) X d (%) X Degree of protection 30 32.50 88.50 88.10 4 DSR 12 H 165 15.40 8.80 IP23 GENERATOR SET CONSUMPTION % POWER USED LITRES/HOUR 50% 4.30 75% 100% 6.50 8.30 DIMENSIONS, CAPACITIES, APPROXIMATE WEIGHT Dimensions (mm) LENGTH WIDTH HEIGHT 2000 950 1353 FUEL TANK (LITRES) WEIGHT (KG) 85 980 NOISE LEVEL (db (A)) 62 @ 7 m

INMESOL GENERATOR SET GENERAL DESCRIPTION The INMESOL generator set is an electrical energy generating machine which is used in places where there is no mains supply or when there is a MAINS failure. The mobile elements, distribution belt, fan, etc., and those parts which reach high temperatures during operation, exhaust manifold, etc, include their corresponding protections, in compliance with the requirements of the Machinery Directive 2006/42. REGULATIONS The machine holds the CE marking, and the corresponding Declaration of Conformity is issued with each of them, in which it specifies that the machine complies with R.D 842/2002 Low Voltage Regulations and with the European Directives: 2006/42 on Safety in Machinery. 2006/95/CE on Electrical Safety. 2004/108/CE on Electromagnetic Compatibility. 2005/88/CE on NOISE EMISSIONS by equipment for outdoor use (for SOUNDPROOF GENERATOR SETS). Teléfono: +34 968 380 129 T: Phone: +31 +34 174968 51380 60879

IN INDUSTRIAL RANGE Scope of supply Engine/alternator monobloc directly connected and installed via silent blocks on a frame made from high tensile electro welded steel profiles that are treated with degreasing liquids and aplicated with a phosphate coat and polyester (QUALICOAT) paint. Canopy of steel sheet sound proofed with fireproof rockwool, and treated with degreasing liquids and aplicated with a phosphate coat and polyester (QUALICOAT) paint. Sealed chassis Fuel tank integrated in the base frame provided with fuel level jauge and fuel connections to the engine. Engine with mechanical engine driven pusher fan. Residencial silencer with -35 db(a) noise reduction with exhaust tube and protection cap. Electric control cubicle with control module including protection and reading of electrical meassures engine instrumentation fuel level and engine running hours, etc. remote start possibility Termal and magnetic circuit breaker and termal and magnetic circuit breaker and earth fault relay. Battery charge alternator. Starter battery complete with cables to the engine and pole protection. Installation prepared for earthing spike (spike not included). Security protection for heat and moving parts as well as live electrical components. External emergency stop push button. Manual engine oil extraction pump. Self excited and auto regulated alternator. Integrated lifting hook for single point lifting with crane, gensets up to 450 kva (Except in swing-out cover model) Base frame is prepared for trailer kit installation. Standard electronic speed governor on engines from 220 kva (LTP) and up. Horizontal outlet for hot air (till canopy 4200x1600x2245) OPTIONS Battery charger Coolant preheating AMF/ATS panel to turn a manual gen set to automatic version (consult the last page) Integral additional socket panel from 20 kva till 400 kva PRP Residential silencer PREWIRED VERSION FOR AMF GENSETS WITH AMF/ATS PANEL AND 4 POLE CIRCUIT BREAKER GENSET WITH AMF CONTROL PANEL BUT WITHOUT ATS PANEL AND SEPARATED ATS PANEL

DSE 3110 MANUAL CONTROL PANEL MANUAL CONTROL, PROTECTION AND DISTRIBUTION panel, assembled on the generator set in metal cabinet with a DSE 3110 engine protection unit. Image for guidance purposes. It has the following: 1. STARTER SWITCH 2. EMERGENCY STOP PUSHBUTTON 3. MEASURING INSTRUMENTS: Analogue(s) ammeter(s) Fuel level indicator. Analogue voltmeter Digital Hz display and hour meter (DSE 3110)

DSE 3110 MANUAL CONTROL PANEL 4. SET CONTROL AND ENGINE PROTECTION: DSE 3110, allows: START AND STOP the set MANUALLY. Possibility of doing it AUTOMATICALLY via START ON SIGNAL Digital readings of the operating hours and the Frequency Controls the main characteristics of the engine, causing an alarm or stopping the machine: Low and High Voltage (STOP) Low and High Frequency and Speed (STOP) Low Oil Pressure and High Coolant Temperature (STOP) Failure of the Alternator Battery-Charger (ALARM) Low fuel level (ALARM) 5. PROTECTIONS MAGNETO. PROTECTION (A) EARTH LEAK PROTECTION DISTRIBUTION 50A, 4P Modular 63A, 30mA CEE5P63A+CEE5P16A+Sc huko

OPTIONS OPTIONAL 1: AUTOMATIC PANEL FOR MANUAL GENERATOR: ATS DSE 334 This panel provides the manual control generator with a reserve operation from the Mains, as the ATS sends the command to start and stop the generator, when it detects a supply failure and when the Mains is restored. It has the following: Change over switch made up of two contactors with mechanical and electrical latching. Battery charger Fuses Mains and group input and charge output connection terminal block. DSE 334 Automatic Transfer Control Module, providing the following functions and features: Output to voltage free relay. Automatic supply failover. Real time clock 10 inputs and 5 outputs can be customised Events log Customisable timers Setup can be completed through PC and/ or through the panel itself. LED indicators. Four-line screen Input for generator set failure. Electric current monitoring (optional) Voltage levels can be adjusted to mains failure Generator availability indicator. Start signal to the engine Image for guidance purposes.

OPTIONS OPTION 2: FAILOVER TO DSE 6010 MKII MANUAL DIGITAL CONTROL MODULE LCD SCREEN: It has a digital LCD screen, which provides easy reading of the information regarding the ENGINE, ALTERNATOR and CHARGING. ENGINE: Coolant temperature Oil pressure Turning speed (rpm) Fuel level Battery voltage Battery alternator voltage Operating hours Number of start-ups CONTROL of the set: ALTERNATOR AND CHARGE: Voltages between phases and between phases and neutral. Intensities Frequency START AND STOP the set MANUALLY. Possibility of doing it AUTOMATICALLY via START ON SIGNAL. Protection of the engine and alternator, with the ALARMS activated: ENGINE: Low oil pressure High coolant temperature Low and High battery Voltage. Failure of the alternator to charge batteries Low fuel level.. Other characteristics: The real-time clock records the last 50 events.s. Configurable inputs and outputs. Configurable alarms and timers. USB connectivity ALTERNATOR: Low and High Voltage Low and High Frequencya Overload due to Intensity (A) Fully configurable via software and PC. Communication via USB cable for remote control Programmable clock with multiple maintenance events which can be configured for optimal motor functioning. Weekly and/or monthly programming for up to 8 startups and shutdowns per week. ALTERNATIVE CONFIGURATIONS, which open up the working possibilities.