INSTALLATION INSTRUCTIONS 410/420 SERIES PUSH SWITCH

Similar documents
INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK

SECURITY DOOR CONTROLS

Security Door Controls

INSTALLATION INSTRUCTIONS 1576DE DELAYED EGRESS EMLOCK

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

EZ-B-10 MAGNETIC BOND SENSOR EZ-T-10 TIMER INPUT MODULE. Modular Kit. Modular Kit. EZ-D-10: DOOR POSITION SENSOR Modular Kit

INSTALLATION INSTRUCTIONS MICRO SHEAR EMLOCKS 1561 & 1562 MAX. HOLDING FORCE 2000 LBS.

INSTALLATION INSTRUCTIONS SHEAR LOCKING MAGNET 1561TJ MAX. HOLDING FORCE 2000 lbs.

INSTALLATION INSTRUCTIONS MINI EXIT CHECK DELAYED EGRESS EMLOCK 1581S

S6100 SERIES REVERSIBLE PANIC/FIRE EXIT RIM DEVICES INSTALLATION INSTRUCTIONS

cel SECURITY DOOR CONTROLS Value Engineered Access Hardware sdcsecurity.com Power Supplies Exit Switches

630 Series Power Supplies

EMLock 1500 Series. MEA Listed. New Modular Kits. Online System Wizard and Project Manager at

Excel Series Value Engineered Access Hardware

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

Electrified Products TABLE OF CONTENTS. P Power Supply Power Transfers Pressure Sense Bars Proximity Cards & Keys...

Spectra Class. N6000 Series Exit Devices SECURITY DOOR CONTROLS. N6100 Rim Mount Exit Device. N6200 Surface Vertical Rod Exit Device.

Accessories 286 SDC SECURITY DOOR CONTROLS

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

GRADE 1 ELECTRIFIED CYLINDRICAL & UNIT LOCKS

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS DEGR7700 DELAYED EGRESS ALL IN ONE DEVICE

S6000 Spectra Exit Devices

ACCESS & EGRESS POWER SUPPLY & DOOR CONTROLS SOLUTIONS. The lock behind the system. SDCSecurity.com

Flight Systems. Replacement for KASSEC DESCRIPTION

Programmable Output Module Installation Manual

ADA Compliant Solution REV

ADA Compliant Solutions

Spectra Class - Specification Grade Exit Devices for superior Architectural Style & Performance

ARCHITECTURAL DOOR HARDWARE POWER SUPPLIES & TRANSFORMER CATALOG

Power Supplies DORMA PS

ELECTROMAGNETIC LOCKS

SOLUTIONS ACCESS & EGRESS. The lock behind the system EGRESS CONTROL. 3.1 Egress Bars Key & Exit Switches

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

WIRING DIAGRAMS FB4C FE4A/FE5A FH4C FV4C FX4D FY5B PF4MA PF4MB LABEL

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

Aura CM-54i Surface Mount Illuminated Enclosure Installation Instructions

PS24/AC Volt AC 16 Amp

Installation Instructions

CB-9 CONTROL BOARD INSTRUCTION MANUAL

Aura CM-55i Flush Mount Illuminated Enclosure Installation Instructions

GCU-10. Automatic Engine Control Unit Operators Manual

ELECTRICAL SYSTEM RP-7

HANDLING MECHANICAL INSTALLATION

EMLock 1500 Series. MEA Listed

Security alarms, warning systems.

LOCKNETICS Power Supplies. 510 Series Power Supply Controller 12 and 24 VDC. 505 Series Power Supply. 505DE Series Delayed Egress Controller

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS

SAFETY

ELECTROMAGNETIC LOCKS

7281-EA/ET INSTRUCTIONS

Doc. No: part_numbering_400.doc Phone (860) Dolphin Road Rev: A Date: 01/26/2007. Fax (860) Bristol, CT, 06010

Electro-Mechanical Swing Operator. Table of Contents

SmartLock Accessories

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

Installation and Wiring Instructions for the TL- Prefix SARGuide Illuminated Touchpad for 80 Series Exit Devices to ElectroLynx Connector System

Package Contents. Mounting Hardware

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

B100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Electric Dropbolts. Secure and Intelligent Bolts. Fail-Safe Series Functions. DPS & BSS Outputs. Fail-Secure Series Functions

Access & Egress Solutions for Building Security and Life Safety

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

ELECTRIC BOLT LOCKS AR-1203A SERIES. (Fail-Safe)(Power to Lock) INSTALLATION INSTRUCTIONS. RoHS. AR-1203A Ver Patent No.

ALARM CONTROLS CORPORATION MSRP PRICING 2014

CAPACITANCE LEVEL SWITCH

Power Transfer Devices

Eternity-TK-Controller (EDC700 Series)

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

Electromagnetic Locks DORMA EML

GENSET CONTROL MODULE A121A / A241A

CX-EMF-2 MULTI-FUNCTION RELAY

Multi-function. Mono-function 1 NO (SPST-NO)

EMLock Magnetic Locks

Vertical Housing EMLock Discount Code GK LIST. Retrofit Kit for Discontinued Locknetics 390+ PLUS

MAXIGARD A2000 SPEED SWITCH. Introduction

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

BZ-150. Installation Instructions. Power Pack SPECIFICATIONS

Gate & Door Controller with LCD and Intelligent Technology

CONTROLLER DIAGNOSTIC GUIDE

Product Catalogue Date:

Typical applications are the control of barriers/booms in the parking and access control environments.

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

115 VAC Control Boxes for

Electrified Products ELECTRIFIED PRODUCTS

Figure 3-9. Right-Hand Port Connector Configuration. 1. Remove electrical power to the Hydraulic Control Unit.

GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM. Special logic to re-establish cranking following a false start.

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

VARIFAN ELECTRONIC TEMPERATURE/ SPEED CONTROLS

PRICE LIST - MARCH 2015

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator

Note: For all general information, refer to Installation and Instruction Manual supplied with the operator.

functions: --Staircase timer --Staircase timer + maintenance function --Staircase timer with early warning

EQ73 Parts list Reference Value Qty Description Marking Dim Manuf. YEL-VIO-BLK-GLD-BRN RED-RED-BRN-BRN RED-RED-BLK-BLK-BRN GRN-BLU-BRN-BRN

Installation/Owner s Manual 1601 / 1602

Emergency Bypass / Shunt Relays (UL924)

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

CAPTROL MODEL 500 MANUAL # R.F. Capacitance Point Level Switch

B-PC20 Power Close Module

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

Transcription:

801 Avenida Acaso, Camarillo, Ca. 93012 (805) 4940622 www.sdcsecurity.com Email: service@sdcsecurity.com 410/420 SERIES PUSH SWITCH (N/C) Contact Type: SPDT (Form C) (COM) (N/O) LAMP 28VDC MAX P:\INSTALLATION INST\Push and Key Switch\INST410420.vsd REV A 0311 Page 1

3580 Willow Lane, Westlake Village, CA 913614921 (805) 4940622 Fax: (805) 4948861 www.sdcsecurity.com Email: service@sdcsecurity.com MODEL 422 PUSH SWITCH 422GPE 422NGPE (N/C) Contact Type: SPDT (Form C) (COM) (N/O) LAMP 28VDC MAX P:\INSTALLATION INST\Push and Key Switch\INST 422.vsd 0305 Page 1

1 2 3 4 5 6 7 8 9 * 0 # PUSH TO EXIT 1 2 3 4 5 6 7 8 9 * 0 # PUSH TO EXIT SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, CA 93012 (805) 4940622 www.sdcsecurity.com Email: service@sdcsecurity.com MODEL 413NU & 423U PUSH SWITCH 160 SECOND ADJUSTABLE TIME DELAY When the button is pressed, the lock releases for 160 seconds. If pressed again during the lock release period, the unit will Retrigger starting a new release period. Input Voltage : 12/24VDC @90ma. Indicator : 12/24VDC @ 10/20ma Output Relay: DPDT Max Load : 30VDC @ 5 AMP 12/24VDC 423U TYPICAL WIRING 413NU 12/24VDC 160 SEC ADJ POT BLK /BLK /BLK COM B /BLK A VIO BLU COM 413NU OR 423U MANUAL RELEASE DEVICE BLK /BLK /BLK COM B /BLK A VIO BLU COM 413NU OR 423U MANUAL RELEASE DEVICE C MD31D FAIL SAFE REQUESTTOEXIT SENSOR DEVICE C MD31D FAIL SAFE REQUESTTOEXIT SENSOR DEVICE C V V C V V ACCESS CONTROL ACCESS CONTROL MD31D MD31D EMLOCK C C FAILSAFE LOCK FAIL SECURE LOCK ACCESS 413NU CONTROL OR 423U ELECTRIC STRIKE ACCESS 413NU CONTROL OR 423U P:\INSTALLATION INST\Push and Key Switch\INST413NU423U.vsd REV E 1013 Page 1

1 2 4 7 5 8 3 6 9 0 # * PUSH TO EXIT SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 4940622 Fax: (805) 4948861 www.sdcsecurity.com Email: service@sdcsecurity.com MODEL 413MN & 423M PUSH SWITCH FIXED 30 SECOND TIME DELAY This push to exit button is specifically intended for installation on Access Controlled Egress doors as described in the Boca code. A motion detector is the primary means of releasing a magnetic lock on the door. The push to exit button is intended, as a back up means of releasing the lock in the event there is a problem with the motion detector. When the button is pressed, the lock releases for 30seconds. If pressed again during the 30seconds lock release period, the unit will Retrigger starting a new 30second lock release period. TYPICAL WIRING 12/24VDC BLK /BLK /BLK COM B /BLK VIO BLU COM C A 413MN OR 423M MANUAL RELEASE DEVICE MD31D FAIL SAFE REQUESTTOEXIT SENSOR DEVICE 423M 413MN Input Voltage : 12/24VDC @90ma. Indicator : 12/24VDC @ 10/20ma Output Relay: DPDT Max Load : 30VDC @ 5 AMP C V V ACCESS CONTROL MOTION DETECTOR EMLOCK C FAILSAFE LOCK ACCESS CONTROL MODEL 413MN/423M PUSH TO EXIT SWITCH P:\INSTALLATION INST\Push and Key Switch\INST413M423M.vsd REV D 0213 Page 1

801 Avenida Acaso, Camarillo, Ca. 93012 (805) 4940622 www.sdcsecurity.com Email: service@sdcsecurity.com 414 & 424 PUSH SWITCH 424U 414NU Contact Type: DPDT (Form C) (COM) (COM) (N/O) (N/O) (N/C) (N/C) LAMP 28VDC MAX P:\INSTALLATION INST\Push and Key Switch\INST414424.vsd REV A 0608 Page 1

SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 913614921 (805) 4940622 Fax: (805) 4948861 www.sdcsecurity.com Email: service@sdcsecurity.com MODEL 415N & 425 ON/OFF PUSH SWITCH 425 415N Contact Type: DPDT (Form C) (N/C) (COM) BLK GRN GRN (N/O) (N/C) (COM) (N/O) P:\INSTALLATION INST\Push and Key Switch\INST 415N425.vsd 0908 Page 1

3580 Willow Lane, Westlake Village, CA 913614921 (805) 4940622 Fax: (805) 4948861 www.sdcsecurity.com Email: service@sdcsecurity.com MODEL 460 REQUEST TO EXIT SWITCH Adjustable Timer 1 40 Seconds * With the jumpers as shown the red s are on in standby and the green s turn on when the relay is on. 1224 VDC * 1 COM1 COM2 2 Specifications Input Voltage: 12/24VDC Current: On: Idle60mA, Active 120mA Off: Idle10mA, Active60mA Outputs: 1 N.O., 1 N.C., 2 Amp @ 30VDC Switch Operating Environment 40 F to 160 F (40 C to 70 C) Dimensions 4.5" H x 2.75" W x 1.25" D (11.4 x 7 x 3.2 cm) Selectable Bicolor Illumination Status Relay Off Red, Green or None Relay On Red, Green or None Red On Standby Green On Relay Action Red On Relay Active Green On Standby Red Off Green Off P:\INSTALLATION INST\Push and Key Switch\INST460.vsd 0305 Page 1