Fulton Electric Steam Boilers

Similar documents
Electric Resistance Boilers Steam or Hot Water

CIRCULATION HEATERS SPECIFICATIONS DESCRIPTION FEATURES CH & CHP SERIES HEAT EXCHANGE AND TRANSFER, INC. 6 to 480 kw and higher. Flanged construction

SUSSMAN 'ES, HU and MBA' SERIES PARTS LIST EFFECTIVE: 7/24/2017

IMMERSION FIRED HOT WATER BOILER

Hamilton 3VO Submittal

Power Rating Minimum Power 218 bkw 292 bhp Maximum Power 359 bkw 482 bhp mm (5.4 in) mm (6.5 in)

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

Series Low Pressure Steam Boiler Safety Valves

Commercial Product Catalog and Price List June Commercial Steambathing Systems

W4100, W4200 & W4300 Electric Pump

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SRH2. Steam Rig Heater. Industrial Grade Heat-Exchanger Unit Heaters. CRN: 0H C 150 psig (1034 KPa)

CSM-K High Capacity Clean Steam Generator

BITZER Liquid Injection Guidelines for CSH Compressors

Universal is a family of commercial gas water heaters that are designed to fit into tight retrofit applications

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h

Steam output 0.3 to 3.0 t/h Operating Pressure 10 to 16 bar

Series CC Condensate Units

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

Series Low Pressure Steam Heating Boiler Safety Valves

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

Electric Furnace KF/KFS Series

254 Series Convector. Standard Construction Features

SECTION H3 TRAYMASTER SERIES DEAERATORS

Date: Project #: Engineer: Prepared By: Bid Date:

Convector. Standard Construction Features

CC3060 TYPE 12 COMPACT CABINET COOLER AIR-TO-WATER FLUSH-MOUNT MODEL

CIRCULATION HEATERS. Applications: Options:

m-csg Ultra-compact Clean Steam Generation System

29 Series OEM Style Bronze Safety Valves for Steam, Air and Non-Hazardous Gas

Pressure Relief Valves. 1541/1543 Series. Consolidated Safety Valve

PIPING PACKAGES TABLE OF CONTENTS

Crest Heating Boilers FBN(L)

National Board Update

Unit Heaters. Catalog MANUFACTURERS HEATING PRODUCTS. Tel: (905) Fax: (905) OF HYDRONIC.

Delivering unsurpassed quality, design and value.

Pressure Relief Valves Series. Consolidated Safety Valve

Pressure Switch with Gauge for Pressure

Penberthy Automatic Injectors

COMMERCIAL CONCENTRATED ENERGY ELECTRIC BOILER 22.5 KW TO 180 KW

Guide Specification SECTION HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY

PREHEATER BYPASS SYSTEMS

Industrial Pumping Equipment Air-Operated Diaphragm Pumps

Controls the destructive forces inherent in high pressure drop service through rapid energy dissipation.

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

NO.2311 AN API Q1, 8C AND ISO 9001:2008 REGISTERED COMPANY

Tamas Hydronic Panels BTU Snow Melt Submittal Technical Data

PIPING PACKAGES For Chilled and Hot Water Fan Coil Units

1541/1543 Series. Consolidated * Valves. Safety Valve

Model CBEX Elite HP

MCU Steam Outlet Pressure 420 psig (29.5 kg/cm 2 ) MCU Steam Outlet Temperature 571 F (299 C). MCU Net Steam Production

UD SERIES COMPRESSORS

General Stem-Guided Control Valves

COMPONENTS FOR SOLAR THERMAL SYSTEMS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

ALSIDENT SYSTEM 75. Easily positioned all-round fume extraction arm

Tamas Hydronic Panels BTU Snow Melt Submittal Technical Data

General Stem-Guided Control Valves

H i g h P r e s s u r e V a l v e

Super Shot Melter/Applicator

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

New Fan Coil Piping Packages

Series 774 Automatic Skid Package

HPUs Hydraulic Power Units

PRESSURE RELIEF VALVES AND ACCESSORIES FOR A WIDE RANGE OF COMMERCIAL AND INDUSTRIAL APPLICATIONS. safety and relief valve catalog

BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS

OMEGA V ECHOS Water/water cooled chillers and heat pumps kw

* T Temperature-Indicating Dial (Must be field set and calibrated to an actual thermometer)

Yarway Hy-Drop Throttling valve

Giotto and Cellini Evoluzione machine range

Commercial Radiant HeaterRH Series

Secondary Coolant 301

RAYPAK ILLUSTRATED PARTS LIST

KRAL Pumps with Magnetic Coupling.

INDUSTRIAL APPLICATIONS OF GAS TURBINES Fall 2010 Course

P a c k a g e s. One step ahead. Energy-efficient Reliable Compact Quiet

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve

1200 Series 1204F-E44TA Industrial Open Power Unit EU Stage IV, EPA Tier 4 Final kw / hp

Rotameters Variable Area Flowmeters

ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

Domestic. Pump Series CS Condensate Units SINGLE OR DUPLEX 1,000 THRU 150,000 SQ. FT. EDR-250 THRU 37,500 LB./HR.

XIII. Repair Parts 106

ELECTRIC SUBMERSIBLE PUMPS SEMISOM/80

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS

91 \\SERVER\CATALOG 2018\2018 Catalog Rev 1 SHUT OFF BALL VALVE

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

Rotameters Variable Area Flowmeters

YARWAY THROTTLING VALVES HY-DROP MODEL 5817/ 5827

VersaFlow Vortex 100 Vortex Flow Meter Specifications

MARINE BOILER SOLAREKS - MARINE BOILER BOILERS & ELECTRIC WATER HEATERS FOR SHIPS SI UNIT CATALOGUE

Hot Water Generator Systems Water to Water Steam to Water. Horizontal or Vertical Jacketed & Insulated

Consolidated* Series

SECTION AIR TERMINAL UNITS

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

Laura Espresso Coffee Machine

Capacity Charts. Direct Spring Acting Safety Relief Valves for Air, Gas, Liquid, and Steam Service

L_Series. L_500 Liquid Ring Compressors

Controls the destructive forces inherent in high pressure drop service through rapid energy dissipation.

High performance safety valve for the protection of large boilers and superheaters, certified to ASME Section I.

Transcription:

Fulton Electric Steam Boilers From 12 to1000 kw (1.2 to100 BHP) A complete line of packaged boilers (15 models) for efficient, quiet and safe operation for any commercial/industrial process application. Built/certified in accordance to ASME Boiler and Pressure Vessel Code. All Fulton Electric Steam Boilers are UL Approved. 1.2-15 BHP are CSA Approved. November 2009

Fulton Electric Steam Boilers Are Efficient, Quiet, And Safe For Your Process Needs Fulton manufactures a complete line of electric steam boilers from 12 kw to 1000 kw (1.2 to 100 BHP) up to 300 PSI for heating and process applications. Fulton's vertical design is a full packaged steam boiler built to ASME specifications and applicable standards and codes. They are very efficient because the heating elements are totally immersed in water and the pressure vessel is fully insulated. Radiation losses are minimal. With a carefully calculated heat to steam ratio, operating pressures are achieved quickly with maximum efficiency. Electric boilers have no wasted fuel going out the stack as associated with fossil fuels, therefore, electric boilers are environmentally friendly. No NOx (nitrogen oxides) are being transmitted to the atmosphere. Stainless steel heating elements Fulton uses low watt density elements* made of stainless steel. Stainless will not melt or anneal as easily as copper elements. The small 12 to 36 kw boilers use horizontally mounted elements at the bottom. *Consult factory for specific watt densities.

50 to 1000 kw elements mount vertically Can be serviced and periodically maintained simply by unbolting the element(s) from the flanges in the top of the boiler's "head". Expansion and contraction of the top mounted elements cause scale to flake off and drop to the bottom of the boiler. Strategically located 3" x 4" handholes allow easy inspection and periodic clean-out maintenance. Fulton can custom build completely piped and wired skid mounted units. Save valuable time and expenses in the field by ordering complete skid mounted units ready for power and water hook up at the sight Unit 1-50 kw (5 BHP) 600 PSIG steam boiler with dual level controls, skid-mounted, pre-piped with feed system and tandem feedwater preheaters. This unit is used for steam injection for pharmaceutical crystallization process. Unit 2-36 kw (3.6 BHP) 15 PSIG electric steam boiler with 3 kw electric steam superheater skid mounted and pre- piped with return system and chemical feed system. Explosion proof, Class 1, Group C, D DN 1. All controls, instrumentation by Fulton including single source power connection. This unit is used for manufacturing/sterilization of surgical equipment. 1 The element(s) are easily accessible-- permit quick removal for service or inspection. Heating element thermostats are optional. Features and advantages Nearly 100% efficient Quiet, clean No NOx emissions Ideal choice where fossil fuels are not available or where electricity rates are favorable Built to ASME Code and UL Approved Vertical design requires minimal floor space Completely wired control panel box located in front of the boiler. Safe. Solid state relays. All wiring meets NEC specifications. Second (auxiliary) low water water cut-off probe standard 2

Component Locations of the Fulton12 to1000 kw (1.2 to 100 BHP) Steam Boilers 1. Pressure Vessel Is Built To ASME Code 5 Year Warranty 2. Electrical Control Panel Box 3. Electric Heating Elements 4. Low Water Cut Off Probe 5. Second (Auxiliary) Low Water Cut Off Probe 6. Pump "On" Probe 7. Pump "Off" Probe 8. Sight Glass Assembly 9. Operating Pressure Control 10. High Limit Pressure Control w/ manual reset 11. Steam Outlet 12. Safety Valve 13. Steam Gauge Assembly 14. Steam Pressure Gauge 15. High Temperature Insulation Surrounds The Pressure Vessel 16. Large (3" x 4") Easily Access Handholes 17. Feedwater Shut Off Valve 18. Blowdown Valve 19. Water Bottle Assembly For 300 to 1000 kw only Note: Al l Fulton Electric Steam Boilers have a second (auxiliary) low water cut-off probe. 12 13 15 50 to 200 kw (5 to 20 BHP) Elements are vertically mounted. All probes are mounted in the top of the boiler. 11 14 3 4 6 7 5 8 12 to 36 kw (1.2 to 3.6 BHP) Element(s) are horizontally mounted at the bottom of the pressure vessel. All probes are located in the top of the boiler. 16 17 18 10 9 2 11 3 1 Note: All Fulton Electric Steam Boilers Have a second (auxiliary) low water cut-off probe.

300 to 1000 kw (30 to 100 BHP) Elements are vertically mounted. These boilers have an externally mounted water bottle assembly housing the low water cut-off probe, pump on probe and pump off probe.the second (auxiliary) low water cut off probe is mounted in the top of the boiler. 6 4 7 19 5

Dimensions Model FB-L 012 015 018 024 030 036 050 075 100 150 200 300 500 750 1000 Unit Size: kw 12 15 18 24 30 36 50 75 100 150 200 300 500 750 1000 HP 1.2 1.5 1.8 2.4 3.0 3.5 5.0 7.5 10 15 20 30 50 75 100 Height (A) Boiler Overall IN 24 24 24 24 24 24 55 55 55 55 55 75 75 75 75 610 610 610 610 610 610 1397 1397 1397 1397 1397 1905 1905 1905 1905 (B) Boiler w/piping IN 30 30 30 30 30 30 65 65 65 65 71 80 80 80 80 762 762 762 762 762 762 1651 1651 1651 1651 1803 2032 2032 2032 2032 (C) Feedwater Inlet IN 8 8 8 8 8 8 16 16 16 16 16 24 24 24 24 203 203 203 203 203 203 406 406 406 406 406 610 610 610 610 (D) Blowdown Outlet IN 4 4 4 4 4 4 6 6 6 6 6 6.5 6.5 6.5 6.5 102 102 102 102 102 102 152 152 152 152 152 165 165 165 165 (E) Electric Control Box IN 20.5 20.5 20.5 20.5 20.5 20.5 50 50 50 50 48 64 64 64 64 521 521 521 521 521 521 1270 1270 1270 1270 1219 1626 1626 1626 1626 (F) Hand Hole IN 11 11 11 11 11 11 38 38 38 38 38 55 55 55 55 279 279 279 279 279 279 965 965 965 965 965 1397 1397 1397 1397 Width & Depth (G) Boiler Only IN 20 20 20 20 20 20 17 24 24 28 32 36 44 50 63 508 508 508 508 508 508 432 610 610 711 813 914 1118 1270 1600 (H) Overall Depth Electric IN 30 30 30 30 30 30 35 35 35 39 46 46 56 62 83 Panel to Blowdown 762 762 762 762 762 762 899 899 899 991 1168 1168 1442 1575 2108 (I) Electric Panel Width IN 14 14 14 14 14 14 17 17 32 32 40 52 64 64 64 356 356 356 356 356 356 432 432 813 813 1016 1321 1626 1626 1626 (J) Boiler Width Overall IN 33 33 33 33 33 33 35 42 42 46 52 56 64 72 91 Minimum Clearances 838 838 838 838 838 838 889 1067 1067 1168 1321 1422 1625 1829 2311 (K) Horizontal IN 14 14 14 14 14 14 -- -- -- -- -- -- -- -- -- to remove elements 356 356 356 356 356 356 -- -- -- -- -- -- -- -- -- (L) Floor to Ceiling IN -- -- -- -- -- -- 95 95 95 95 95 139 139 139 139 to remove elements -- -- -- -- -- -- 2413 2413 2413 2413 2413 3531 3531 3531 3531 (M) Front of Boiler IN 24 24 24 24 24 24 24 32 32 32 34 34 36 36 36 610 610 610 610 610 610 610 813 813 813 864 864 914 914 914 (N) Sides & Rear of Boiler IN 12 12 12 12 12 12 12 12 12 12 24 24 24 24 24 305 305 305 305 305 305 305 305 305 305 610 610 610 610 610 Dimensions are approximate. We reserve the right to change specifications. Indicates not available. Panel Box size may change depending on voltage. N Models FB-L 012-036 12 to 36 kw (1.2 to 3.6 BHP) Models FB-L 050-1000 50 kw to 1000 kw (5-100 BHP) N TOP N M TOP N J G H J G M K H FRONT L SIDE B FRONT I A E SIDE F D C B I A E F D C

Specifications Model FB-L 012 015 018 024 030 036 050 075 100 150 200 300 500 750 1000 Number of Elements Output Steam Output** Approx. Shipping Weight Water Capacity 1000 BTU/HR 1000 KCAL/HR LB/HR KG/HR LB KG GALLONS LITERS Boiler Connection Sizes Steam Outlet 15 PSI IN Steam Outlet 16-300 PSI IN Feedwater Inlet IN Blowdown Outlet IN Water Col. Blowdown Outlet IN Sight Glass Blowdown Outlet IN Safety Valve 15 PSI IN Safety Valve 16-300 PSI IN Electrical Power Requirements 208V 3 Phase 230V 1 Phase 230V 3 Phase 460V 3Phase 575V 3 Phase Dimensions are approximate. We reserve the right to change specifications. Voltage applied higher than above ratings will result in higher amp draws. Probe liquid level control is standard on all units. Optional Water Level Controls McDonnell Miller 53-2 McDonnell MIller 157-157M Notes: --Indicates not available. * Indicates voltages available at special request. **Steam output ratings, at 180 o F (82 o C) feedwater temperature,(0 PSIG). Standard Electrical Control Panel Components Low Water Relay Water Level Relay High Limit Pressure Control Switch w/manual reset Operating Pressure Control Element Contactor(s) Switch Pump Starter (1 phase) Power Switch Power Lamp Element Energized Lamp CSD-1 Low Water Relay With Manual Reset Models FB-L 100 to FB-L 1000 include a step sequencer. 1 1 1 2 2 2 2 3 4 6 4 4 7 10 14 41 51 61 82 102 123 171 256 341 512 683 1025 1708 2561 3416 10 13 15 21 26 31 43 64 86 129 172 258 430 645 860 40 50 60 81 101 121 169 252 336 505 674 1011 1684 2526 3368 18 23 27 37 46 55 77 115 153 230 306 460 765 1148 1530 420 420 420 440 450 450 580 850 970 1225 1380 1440 1850 2150 2300 191 191 191 200 204 204 263 386 440 556 623 655 839 977 1043 7 7 7 7 7 7 13 39 39 50 79 115 195 270 360 26 26 26 26 26 26 49 148 148 189 299 435 738 1022 1362.75.75.75.75.75.75 1 1.5 1.5 2 3 3 4 4 6 19 19 19 19 19 19 25 38 38 51 76 76 100 100 150 75.75.75.75.75.75.75 1 1 1.25 1.5 2 3 3 3 19 19 19 19 19 19 19 25 25 32 38 51 76 76 76.75.75.75.75.75.75.75 1 1 1 1 1 1 1 1.25 19 19 19 19 19 19 19 25 25 25 25 25 25 25 32 1 1 1 1 1 1 1 1 1 1 1.25 1.25 1.5 1.5 2 25 25 25 25 25 25 25 25 25 25 32 32 38 38 51 NA NA NA NA NA NA NA NA NA NA NA.75.75.75 75 -- -- -- -- -- -- -- -- -- -- -- 19 19 19 19.25.25.25.25.25.25.25.25.25.25.25.25.25.25.25 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6.75.75.75.75.75.75 1 1 1 1.25 1.50 1.5 1.5 2 2.5 19 19 19 19 19 19 25 25 25 32 38 38 38 51 64.50.50.50.50.50.50.75.75.75.75 1 1 1.25 1.5 2 13 13 13 13 13 13 19 19 19 19 25 25 32 38 51 (In Amps) 34 42 50 67 84 100 139 208 278 416 556 832 * * * 52 65 78 -- -- -- -- -- -- -- -- -- -- -- -- 30 35 46 60 76 92 126 188 252 378 512 756 * * * 15 19 23 30 38 46 63 94 126 189 256 378 630 941 1260 13 16 18 24 30 36 50 76 101 150 201 301 502 756 1004

Applications - Pressing operations in drycleaning and tailor shops, food, chemical, pharmaceutical, plastics processing, sterilization, humidification control anywhere heat/steam is needed. The Fulton Companies 972 Centerville Road Pulaski, NY 13142 Call: (315) 298-5121 Fax: (315) 298-6390 www.fulton.com Fulton is a global manufacturer of steam, hot water & thermal fluid heat transfer systems 2009-1113 Electric BRO