INTRODUCTION ZONE CHARACTERISTICS SURGES

Similar documents
FINHRM FINHRM5 FINHRMA FINHRMAC

Surge-Trap Pluggable STPT2 Series - 40kA

STABILINE. Surge Protective Devices. PT1 Series Type 2 SPD. Installation, Operation and Maintenance Manual

D509E. Manual Motor - Starters

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

NH DIN Dual Indication Fuse Links

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP)

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Micro Contactor MA Series

Description. Positive safety relays

Technical data sheets

Compact Circuit Protector (CCP)

Technical data for manual motor starters Type MS325

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

8WH2 Spring-Loaded Terminals

Series KTU7 UL489 Molded Case Circuit Breakers

INNOZED D0 fuse-bases with touch protection

IS46/PS33 Current Power Supply System

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

INNOZED D0 fuse-bases with touch protection

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Industrial Power Supplies

8WH2 Spring-Loaded Terminals

Compact Circuit Protector

Aurora Single Phase Emergency Lighting Inverters

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Compact Circuit Protector

Electronic overload relays EF205 and EF370

DART Charger Product Description, Information and Specification

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Electronic overload relay EF65, EF96 and EF146

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN

Compact Circuit Protector (CCP)

Technical Data Sheets

and other modular devices for low voltage installation

Modulostar US10 Modular fuse-holders

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

Technical Data Sheets

S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Series KTU7 UL489 Molded Case Circuit Breakers

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Modulostar CMS10 Modular fuse-holders

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Synergy EN product information

S1024-2POS / S POS S2024-2POS / S POS

Current transformers. Current transformers

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Uninterruptible Power Supply

Special Purpose Fuses

Technical Information

Terminal Blocks Product Catalog Terminal Block Supplement. Introduction. 8WH6 ipo Plug-In Terminals. 8WH6 ipo Installation Terminals

EE 741 Over-voltage and Overcurrent. Spring 2014

Power Switching Devices

power cable accessories

SECTION DC POWER SUPPLY/BATTERY CHARGER

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

LINOCUR Size D02 63A 230VAC/440VAC

LV Capacitor CLMD03 Power Module Instruction manual

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

CI-TI Contactors and motor starters Types CI 61 - CI 98

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

IEC Low Voltage General Purpose Protection

Technical Data Sheets

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

GREEN PROTECT PROTECTION OF PV SYSTEMS. Green protect - DC POWER NEEDS CONTROL

FMotor Circuit Controllers

Series L9 UL489 Miniature Circuit Breakers

Fuse holders and fuses

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

Series L9 UL-489 Miniature Circuit Breakers

Technical data sheets

CHS Controls. Photovoltaic system protection.

Solid State Relays, 3-phase

Fused Coordination Panelboard

Single-Phase Step Voltage Regulators

Solid State Relays contactor with Integrated Fuse Type RGC1F

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MCD 200 Series Soft Starters

Bussmann PV Application guide. Complete and reliable solar circuit protection

POWERTRONIX QUASAR 5-40 KVA

1329I Integrated Drive/Motor CE Filter Option Kit

Transcription:

Surge Arrester

INTRODUCTION Surge Arresters Safe and Reliable Protection for Electrical Equipment The Enerdoor surge arrester series has been specifically designed to protect electrical equipment. Surge arresters are installed at the front end of a system for the purpose of diverting harmful overvoltage transients caused by external (lightning) and/or internal (switching) events to ground safely. Also known as Surge Protection Device (SPD), or Transient Voltage Surge Suppressor (TVSS), Enerdoor surge arrestors protect against electrical transients resulting from lightning strikes that find their way onto electrical conductors. All models include remote contact, visual indicator, and comply with the UL 1449, IEC 61643-11, and VDE 0675 International Standards. DIN rail or screw mounting options are available with select models offering plug and play replaceable cards for quick and easy installation and replacement. Voltage Lightning Operations Irms Types of Surge Arresters Surge arresters are divided by zone: ZONE CHARACTERISTICS SURGES LZP 0A External zone exposed to direct lightning strikes Full lightning current and unattenuated electric field LZP 0B External zone within lightning prevention system (LPS) and Part of the lightning current protected against direct strikes and unattenuated electric field LZP 1 Internal zone where surge is limited by current spreading, Low currents and up stream SPDs and screening attenuated electric fields LZP 2 Internal zone where surge is less than LZP 1 due to current Minimum currents and spreading, screening and up stream SPDs very attenuated electric fields Recommended max cable length for surge arrester in branch circuits Example of main supply INTRODUCTION 3

INTRODUCTION ENERDOOR SURGE ARRESTERS TN-S/TT Mains Line L1 L2 L3 N PE Description 3-phase, N-PE separated Class 1+2 Class 1+2 Class 1+2 Class 2 Class 2+3 Class 2+3 Class 2+3 BMG 12,5 BGG 25 BGG 50 PR EMG 25 EMG 40 EMG 80 EMG 120 Class 2+3 TN-C L1 L2 L3 PEN 3-phase, N-PE connected BMG 12,5 BGG 25 BGG 50 PR EMG 25 EMG 40 EMG 80 EMG 120 TN-S/TT L1 L2 N PE 2-phase, N-PE separated BMG 12,5 BGG 25 BGG 50 PR EMG 25 EMG 40 EMG 80 EMG 120 BMG 12,5 BGG 25 BGG 50 PR EMG 25 EMG 40 EMG 80 EMG 120 TN-C L1 L2 PEN 2-phase, N-PE connected TN-S/TT L1 N PE 1-phase, N-PE separated BMG 12,5 BGG 25 BGG 50 PR EMG 25 EMG 40 EMG 80 EMG 120 BMG 12,5 BGG 25 BGG 50 PR EMG 25 EMG 40 EMG 80 EMG 120 TN-C L1 PEN 1-phase, N-PE connected INDEX Class I AM SERIES 5 Class I+II BM (G) 12.5 SERIES 7 BG (G) 25 SERIES _ 9 BG (G) 50 SERIES _ 11 Class II+III EMG (G) 20 SERIES 15 EMG (G) 40 SERIES 17 EMG (G) 60 SERIES 19 Class II FINPR SERIES _ 13 FINPRS SERIES 21 4 INTRODUCTION

AM SERIES Surge Arrester Class I The Enerdoor surge arrester AM series provides advanced surge protection. This device is designed for maximum discharge of 300 ka. As a standard this series is offered in a metal enclosure and includes a visual indicator and optional remote alarm. GENERAL CHARACTERISTICS SCCR Lightening counter current Fail pre test Protection Power status indication Working status indication Power connecting cable Signal cable Working enviroments Dimensions WxDxH (in mm) 256 x 205 x 104 Net weight 5.4 Kg 200 ka >200 ka Press 2 sec reset button L N, N PE, L PE Normal = Power LED ON Normal = Blue LED ON Fail = Red LED ON 8 AWG (L1=yellow, L2=green, L3=red N=blue, PE=black) 16 AWG (C=red, NC=blue, NO=brown) Temperature ( 40 C + 70 C, Humidity relative up to 95% (25 C), altitude <2000 meter) AM System Voltage (50/60Hz) Protection Mode Voltage Protection Rated (VPR@6KV/3KA) Surge Capability KA L-N L-PE N-PE L-L L-N L-PE N-PE L-L PHASE MODE Max Continuos Voltage AM120SP100-5 120/240 split (fig.1) - 800 800 800 1200 100 50 180 AM120SP200-5 120/240 split (fig.1) - 800 800 800 1200 200 100 180 AM120SP300-5 120/240 split (fig.1) - 800 800 800 1200 300 150 180 AM127Y100-7 220Y127 WYE (fig.2) - 800 800 800 1200 100 50 180 AM127Y200-7 220Y127 WYE (fig.2) - 800 800 800 1200 200 100 180 AM127Y300-7 220Y127 WYE (fig.2) - 800 800 800 1200 300 150 180 AM220Y100-7S 380Y220 WYE (fig.2) - 1200 1200 1200 2000 100 50 320 AM220Y200-7S 380Y220 WYE (fig.2) - 1200 1200 1200 2000 200 100 320 AM220Y300-7S 380Y220 WYE (fig.2) - 1200 1200 1200 2000 300 150 320 AM277Y100-7 480Y277 WYE (fig.2) - 1200 1200 1200 2000 100 50 320 AM277Y200-7 480Y277 WYE (fig.2) - 1200 1200 1200 2000 200 100 320 AM277Y300-7 480Y277 WYE (fig.2) - 1200 1200 1200 2000 300 150 320 AM347Y100-7 600Y347 WYE (fig.2) - 1500 1500 1500 2500 100 50 420 AM347Y200-7 600Y347 WYE (fig.2) - 1500 1500 1500 2500 200 100 420 AM347Y300-7 600Y347 WYE (fig.2) - 1500 1500 1500 2500 300 150 420 AM120H100-7 120/240 H LEG (fig.3) - 1000 1000 800 1500 100 50 180/275 SURGE ARRESTER CLASS I 5

AM SERIES Surge Arrester Class I AM System Voltage (50/60Hz) Voltage Protection Rated Protection Mode Surge Capability KA Max (VPR@6KV/3KA) Continuos Voltage L-N L-PE N-PE L-L L-N L-PE N-PE L-L PHASE MODE AM120H200-7 120/240 H LEG (fig.3) - 1000 1000 800 1500 100 50 180/275 AM120H300-7 120/240 H LEG (fig.3) - 1000 1000 800 1500 100 50 180/275 AM240D100-6S 240 Delta (fig.4) - - - 1200-1400 100 50 320 AM240D200-6S 240 Delta (fig.4) - - - 1200-1400 200 100 320 AM240D300-6S 240 Delta (fig.4) - - - 1200-1400 300 150 320 AM480D100-6S 480 Delta (fig.4) - - - 1900-2200 100 50 550 AM480D200-6S 480 Delta (fig.4) - - - 1900-2200 200 100 550 AM480D300-6S 480 Delta (fig.4) - - - 1900-2200 300 150 550 AM600D100-6S 600 Delta (fig.4) - - - 2400-2800 100 50 690 AM600D200-6S 600 Delta (fig.4) - - - 2400-2800 200 100 690 AM600D300-6S 600 Delta (fig.4) - - - 2400-2900 300 150 690 AM127S100-3 127 Single (fig. 5) - 800 800 800-100 50 180 AM127S200-3 127 Single (fig. 5) - 800 800 800-200 100 180 AM127S300-3 127 Single (fig. 5) - 800 800 800-300 150 180 AM240S1003S 240 Single (fig. 5) - 1200 1200 1200-100 50 320 AM240S200-3S 240 Single (fig. 5) - 1200 1200 1200-200 100 320 AM240S300-3S 240 Single (fig. 5) - 1200 1200 120-300 150 320 Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 SPLIT 2 Hots, 1 Neu, 1 Grnd WYE 3 Hots, 1 Neu, 1 Grnd HI-LEG DELTA (B High) 3 Hots, (B HIGH), 1 Neu, 1 Grnd DELTA & HRG WYE 3 Hots, 1 Grnd SINGLE POLE 1 Hot, 1 Neu, 1 Grnd 6 SURGE ARRESTER CLASS I

BM (G) 12.5 SERIES Surge Arrester Class I+II The Enerdoor surge arrester BM (G) 12.5 series provides advanced surge protection. This device is designed for maximum discharge of L N 65 ka and N PE 100 ka, meets the UL 1449 3rd edition and IEC61643 11:2011 Standards, and includes a visual and remote contact indicator. BM (G) 12.5 Nominal Voltage Vac L-L (L-N) GENERAL CHARACTERISTICS Class category IEC/VDE I + II / B+C Operating temperature range 40 C + 80 C Operating humidity range 0 ~ 90% Response time L N (N PE) 25 ns (<100ns) Backup fuse 250 Amps gl/gg (only required if not in the main) Flow current L N No N PE If 100 Arms @ 255 Vac Enclosure material Thermoplastic, UL94 V 0 Mounting 35mm DIN rail according to the EN50022/DIN46277-3 Standard Max size of connecting wire Single strand 35mm2 (or # 2AWG) Multi strand 25mm2 (or # 4AWG) Remote alarm contact type Isolated form C Switching capability Un/In AC: 250V/0.5A DC: 250V/0.1A Max size of connecting wire Max 1.5mm 2 (or #16AWG) Max Continuous Operation Voltage NPE - Vac Nominal Discharge (In, KA) 8/20 Max Discharge Current (Imax, KA) Voltage Protection Rated (kv) L-N N-PE L-N N-PE LN@In L-N@VPR NPE (1.2/50) BM.150 1P12.5 150-12.5-65 - <0.7 <0.6-1 BM.275 1P12.5 275-12.5-65 - <1.0 <0.8-1 BM.320 1P12.5 320-12.5-65 - <1.4 <1.2-1 BM.385 1P12.5 385-12.5-80 - <1.6 <1.4-1 BM.420 1P12.5 420-12.5-80 - <1.8 <1.5-1 BMG.150 2P12.5 N25 208 (150) 150 12.5 25 65 100 <0.7 <0.6 <0.8 2 BMG.150 2P12.5 N50 208 (150) 150 12.5 50 65 100 <0.7 <0.6 <0.8 2 BMG.275 2P12.5 N25 320 (275) 150 12.5 25 65 100 <1.0 <0.8 <1.5 2 BMG.275 2P12.5 N50 320 (275) 150 12.5 50 65 100 <1.0 <0.8 <1.5 2 BMG.320 2P12.5 N25 400 (320) 255 12.5 25 65 100 <1.4 <1.2 <1.5 2 BMG.320 2P12.5 N50 400 (320) 255 12.5 50 65 100 <1.4 <1.2 <1.5 2 BMG.385 2P12.5 N25 480 (385) 255 12.5 25 80 100 <1.6 <1.4 <1.5 2 BMG.385 2P12.5 N50 480 (385) 255 12.5 50 80 100 <1.6 <1.4 <1.5 2 BMG.420 2P12.5 N25 600 (420) 255 12.5 25 80 100 <1.8 <1.5 <1.5 2 BMG.420 2P12.5 N50 600 (420) 255 12.5 50 80 100 <1.8 <1.5 <1.5 2 BMG.150 3P12.5 N25 208 (150) 150 12.5 25 65 100 <0.7 <0.6 <0.8 3 BMG.150 3P12.5 N50 208 (150) 150 12.5 50 65 100 <0.7 <0.6 <0.8 3 BMG.275 3P12.5 N25 320 (275) 150 12.5 25 65 100 <1.0 <0.8 <1.5 3 BMG.275 3P12.5 N50 320 (275) 150 12.5 50 65 100 <1.0 <0.8 <1.5 3 BMG.320 3P12.5 N25 400 (320) 255 12.5 25 65 100 <1.4 <1.2 <1.5 3 BMG.320 3P12.5 N50 400 (320) 255 12.5 50 65 100 <1.4 <1.2 <1.5 3 BMG.385 3P12.5 N25 480 (385) 255 12.5 25 80 100 <1.6 <1.4 <1.5 3 BMG.385 3P12.5 N50 480 (385) 255 12.5 50 80 100 <1.6 <1.4 <1.5 3 BMG.420 3P12.5 N25 600 (420) 255 12.5 25 80 100 <1.8 <1.5 <1.5 3 BMG.420 3P12.5 N50 600 (420) 255 12.5 50 80 100 <1.8 <1.5 <1.5 3 Case SURGE ARRESTER CLASS I+II 7

BM (G) 12.5 SERIES Surge Arrester Class I+II ELECTRICAL DIAGRAM SCHEMATIC 1 SCHEMATIC 2 SCHEMATIC 3 MECHANICAL DIMENSIONS (mm) CASE 1 CASE 2 CASE 3 8 SURGE ARRESTER CLASS I+II

BG (G) 25 SERIES Surge Arrester Class I+II The Enerdoor surge arrester BG (G) 25 series provides advanced surge protection. This device is designed for maximum discharge of L N 100 ka and N PE 200 ka, meets the UL 1449 3rd edition and IEC61643 11:2011 Standards, and includes a visual and remote contact indicator. BG (G) 25 Nominal Voltage Vac L-L (L-N) GENERAL CHARACTERISTICS Class category IEC/VDE I + II / B+C Operating temperature range 40 C + 80 C Operating humidity range 0 ~ 90% Response time L N (N PE) 25 ns (<100ns) Backup fuse 250 Amps gl/gg (only required if not in the main) Flow current L N If 10 karms @ 255 Vac N PE If 100 Arms @ 255 Vac Enclosure material Thermoplastic, UL94 V 0 Mounting 35mm DIN rail according to the EN50022/DIN46277-3 Standard Max size of connecting wire Single strand 35mm 2 (or # 2AWG) Multi strand 25mm 2 (or # 4AWG) Remote alarm contact type Isolated form C Switching capability Un/In AC: 250V/0.5A DC: 250V/0.1A Max size of connecting wire Max 1.5mm 2 (or #16AWG) Max Continuous Operation Voltage NPE - Vac Nominal Discharge (In, KA) 8/20 Max Discharge Current (Imax, KA) Voltage Protection Rated (kv) L-N N-PE L-N N-PE LN@In NPE (1.2/50) Electrical Diagram BG.150 1P25 150-25 - 100 - <1.2-1 1 BG.275 1P25 275-25 - 100 - <1.5-1 1 BG.320 1P25 320-25 - 100 - <1.6-1 1 BG.385 1P25 385-25 - 100 - <1.8-1 1 BG.420 1P25 420-25 - 100 - <2.0-1 1 BG.150 2P25 150-25 - 100 - <1.2-2 2 BG.275 2P25 275-25 - 100 - <1.5-2 2 BG.320 2P25 320-25 - 100 - <1.6-2 2 BG.385 2P25 385-25 - 100 - <1.8-2 2 BG.420 2P25 420-25 - 100 - <2.0-2 2 BG.150 3P25 150-25 - 100 - <1.2-3 3 BG.275 3P25 275-25 - 100 - <1.5-3 3 BG.320 3P25 320-25 - 100 <1.6-3 3 BG.385 3P25 385-25 - 100 - <1.8-3 3 BG.420 3P25 420-25 - 100 - <2.0-3 3 BG.150 4P25 150-25 - 100 - <1.2 4 4 BG.275 4P25 275-25 - 100 - <1.5-4 4 BG.320 4P25 320-25 - 100 - <1.6-4 4 BG.385 4P25 385-25 - 100 - <1.8-4 4 BG.420 4P25 420-25 - 100 - <2.0-4 4 BGG.150 2P25 N50 208 (150) 150 25 50 100 150 <1.2 <0.8 5 2 BGG.150 2P25 N100 208 (150) 150 25 100 100 200 <1.2 <0.8 5 2 BGG.275 2P25 N50 320 (275) 255 25 50 100 150 <1.5 <1.5 5 2 BGG.275 2P25 N100 320 (275) 255 25 100 100 200 <1.5 <1.5 5 2 Case SURGE ARRESTER CLASS I+II 9

BG (G) 25 SERIES Surge Arrester Class I+II BG (G) 25 Nominal Voltage Vac L-L (L-N) Max Continuous Operation Voltage NPE - Vac Nominal Discharge (In, KA) 8/20 Max Discharge Current (Imax, KA) Voltage Protection Rated (kv) L-N N-PE L-N N-PE LN@In NPE (1.2/50) Electrical Diagram BGG.320 2P25 N50 400 (320) 255 25 50 100 150 <1.6 <1.5 5 2 BGG.320 2P25 N100 400 (320) 255 25 100 100 200 <1.6 <1.5 5 2 BGG.385 2P25 N50 480 (385) 255 25 50 100 150 <1.8 <1.5 5 2 BGG.385 2P25 N100 480 (385) 255 25 10 100 200 <1.8 <1.5 5 2 BGG.420 2P25 N50 600 (420) 255 25 50 100 150 <2.0 <1.5 5 2 BGG.420 2P25 N100 600 (420) 255 25 100 100 200 <2.0 <1.5 5 2 BGG.150 3P25 N50 208 (150) 255 25 50 100 150 <1.2 <0.8 6 4 BGG.150 3P25 N100 208 (150) 255 25 100 100 200 <1.2 <0.8 6 4 BGG.275 3P25 N50 320 (275) 255 25 50 100 150 <1.5 <1.5 6 4 BGG.275 3P25 N100 320 (275) 255 25 100 100 200 <1.5 <1.5 6 4 BGG.320 3P25 N50 400 (320) 255 25 50 100 150 <1.6 <1.5 6 4 BGG.320 3P25 N100 400 (320) 255 25 100 100 200 <1.6 <1.5 6 4 BGG.385 3P25 N50 480 (385) 255 25 50 100 150 <1.8 <1.5 6 4 BGG.385 3P25 N100 480 (385) 255 25 100 100 200 <1.8 <1.5 6 4 BGG.420 3P25 N50 600 (420) 255 25 50 100 150 <2.0 <1.5 6 4 BGG.420 3P25 N100 600 (420) 255 25 100 100 200 <2.0 <1.5 6 4 ELECTRICAL DIAGRAM SCHEMATIC 1 SCHEMATIC 2 SCHEMATIC 3 Case SCHEMATIC 4 SCHEMATIC 5 SCHEMATIC 6 MECHANICAL DIMENSIONS (mm) CASE 1 CASE 2 CASE 3 CASE 4 10 SURGE ARRESTER CLASS I+II

BG (G) 50 SERIES Surge Arrester Class I+II The Enerdoor surge arrester BG (G) 50 series provides advanced surge protection. This device is designed for maximum discharge of L N 100 ka and N PE 200 ka, meets the UL 1449 3rd edition and IEC61643 11:2011 Standards, and includes a visual and remote contact indicator. BG (G) 50 Nominal Voltage Vac L-L (L-N) GENERAL CHARACTERISTICS Class category IEC/VDE I + II / B+C Operating temperature range 40 C + 80 C Operating humidity range 0 ~ 90% Response time L N (N PE) 100 ns Backup fuse 500 Amps gl/gg (only required if not in the main) Flow current L N If 10 karms @ 255 Vac N PE If 100 Arms @ 255 Vac Enclosure material Thermoplastic, UL94 V 0 Mounting 35mm DIN rail according to the EN50022/DIN46277-3 Standard Max size of connecting wire Single strand 35mm 2 (or # 2AWG) Multi strand 25mm 2 (or # 4AWG) Remote alarm contact type Isolated form C Switching capability Un/In AC: 250V/0.5A DC: 250V/0.1A Max size of connecting wire Max 1.5mm 2 (or #16AWG) Max Continuous Operation Voltage NPE - Vac Nominal Discharge (In, KA) 8/20 Max Discharge Current (Imax, KA) Voltage Protection Rated (kv) L-N N-PE L-N N-PE LN@In NPE (1.2/50) Electrical Diagram BG.150-1P50 150-50 - 150 - <1.2-1 1 BG.275-1P50 275-50 - 150 - <1.5-1 1 BG.320-1P50 320-25 - 150 - <1.6-1 1 BG.385-1P50 385-50 - 150 - <1.8-1 1 BG.420-1P50 420-50 - 150 - <2.0-1 1 BG.150-2P50 150-50 - 150 - <1.2-2 2 BG.275-2P50 275-50 - 150 - <1.5-2 2 BG.320-2P50 320-50 - 150 - <1.6-2 2 BG.385-2P50 385-50 - 150 - <1.8-2 2 BG.420-2P50 420-50 - 150 - <2.0-2 2 BG.150-3P50 150-50 - 150 - <1.2-3 3 BG.275-3P50 275-50 - 150 - <1.5-3 3 BG.320-3P50 320-50 - 150 - <1.6-3 3 BG.385-3P50 385-50 - 150 - <1.8-3 3 BG.420-3P50 420-50 - 150 - <2.0-3 3 BG.150-4P50 150-50 - 150 - <1.2-4 4 BG.275-4P50 275-50 - 150 - <1.5-4 4 BG.320-4P50 320-50 - 150 - <1.6-4 4 BG.385-4P50 385-50 - 150 - <1.8-4 4 BG.420-4P50 420-50 - 150 - <2.0-4 4 BGG.150-2P50-N50 208 (150) 150 50 50 150 150 <1.2 <0.8 5 2 BGG.150-2P50-N100 208 (150) 150 50 100 150 200 <1.2 <0.8 5 2 BGG.275-2P50-N50 320 (275) 255 50 50 150 150 <1.5 <1.5 5 2 BGG.275-2P50-N100 320 (275) 255 50 100 150 200 <1.5 <1.5 5 2 Case SURGE ARRESTER CLASS I+II 11

BG (G) 50 SERIES Surge Arrester Class I+II BG (G) 50 Nominal Voltage Vac L-L (L-N) Max Continuous Operation Voltage NPE - Vac Nominal Discharge (In, KA) 8/20 Max Discharge Current (Imax, KA) Voltage Protection Rated (kv) L-N N-PE L-N N-PE LN@In NPE (1.2/50) Electrical Diagram BGG.320-2P50-N50 400 (320) 255 50 50 150 150 <1.6 <1.5 5 2 BGG.320-2P50-N100 400 (320) 255 50 100 150 200 <1.6 <1.5 5 2 BGG.385-2P50-N50 480 (385) 255 50 50 150 150 <1.8 <1.5 5 2 BGG.385-2P50-N100 480 (385) 255 50 100 150 200 <1.8 <1.5 5 2 BGG.420-2P50-N50 600 (420) 255 50 50 150 150 <2.0 <1.5 5 2 BGG.420-2P50-N100 600 (420) 255 50 100 150 200 <2.0 <1.5 5 2 BGG.150-3P50-N50 208 (150) 255 50 50 150 150 <1.2 <0.8 6 4 BGG.150-3P50-N100 208 (150) 255 50 100 150 200 <1.2 <0.8 6 4 BGG.275-3P50-N50 320 (275) 255 50 50 150 150 <1.5 <1.5 6 4 BGG.275-3P50-N100 320 (275) 255 50 100 150 200 <1.5 <1.5 6 4 BGG.320-3P50-N50 400 (320) 255 50 50 150 150 <1.6 <1.5 6 4 BGG.320-3P50-N100 400 (320) 255 50 100 150 200 <1.6 <1.5 6 4 BGG.385-3P50-N50 480 (385) 255 50 50 150 150 <1.8 <1.5 6 4 BGG.385-3P50-N100 480 (385) 255 50 100 150 200 <1.8 <1.5 6 4 BGG.420-3P50-N50 600 (420) 255 50 50 150 150 <2.0 <1.5 6 4 BGG.420-3P50-N100 600 (420) 255 50 100 150 200 <2.0 <1.5 6 4 Case ELECTRICAL DIAGRAM SCHEMATIC 1 SCHEMATIC 2 SCHEMATIC 3 SCHEMATIC 4 SCHEMATIC 5 SCHEMATIC 6 MECHANICAL DIMENSIONS (mm) CASE 1 CASE 2 CASE 3 CASE 4 12 SURGE ARRESTER CLASS I+II

FINPR SERIES Surge Arrester Class II The Enerdoor surge arrester FINPR series provides advanced surge protection. This device is designed for maximum discharge of 50 ka, meets the UL 1449 3 rd edition and IEC61643 11:2011 Standards, and includes a visual and remote contact indicator. GENERAL CHARACTERISTICS Class category IEC/VDE II / C Operating temperature range 40 C + 80 C Operating humidity range 0 ~ 90% Response time 25 ns Backup fuse 125 Amps gl/gg (only required if not in the main) Enclosure material Thermoplastic, UL94 V 0 Mounting 35mm DIN rail according to the EN50022/DIN46277-3 Standard Max size of connecting wire Single strand 35mm 2 (or # 2AWG) Multi strand 25mm 2 (or # 4AWG) Remote alarm contact type Isolated form C Switching capability Un/In AC: 250V/0.5A DC: 250V/0.1A Max size of connecting wire Max 1.5mm 2 (or #16AWG) FINPR Nominal Nominal Discharge Max Discharge Current Voltage Protection Rated (kv) Voltage (In, KA) 8/20 SCCR Electrical Mechanical (Imax, KA) AC (ka) Diagram Case L-N N-PE L-N N-P @In @VPR L-N@MLV N-PE@MLV L-N@1.2/50 PR.150 150 20 20 50 50 <0.8 <0.6 <1.7 - - 200 1 1 PR.275 275 20 20 50 50 <1.4 <0.9 <2.1 - - 200 1 1 PR.320 320 20 20 50 50 <1.5 <1.0 <2.2 - - 200 1 1 PR.420 420 20 20 50 50 <2 <1.5 <2.4 - - 200 1 1 PR.550 550 20 20 50 50 <2.5 <1.8 <2.5 - - 200 1 1 PR.690 690 20 20 50 50 <3 <2.8 <3.2 - - 200 1 1 PR.150-2P 150 20 20 50 50 <0.8 <0.6 <1.7 - - 200 2 2 PR.275-2P 275 20 20 50 50 <1.4 <0.9 <2.1 - - 200 2 2 PR.320-2P 320 20 20 50 50 <1.5 <1.0 <2.2 - - 200 2 2 PR.420-2P 420 20 20 50 50 <2 <1.5 <2.4 - - 200 2 2 PR.550-2P 550 20 20 50 50 <2.5 <1.8 <2.5 - - 200 2 2 PR.690-2P 690 20 20 50 50 <3 <2.8 <3.2 - - 200 2 2 PR.150-3P 150 20 20 50 50 <0.8 <0.6 <1.7 - - 200 3 3 PR.275-3P 275 20 20 50 50 <1.4 <0.9 <2.1 - - 200 3 3 PR.320-3P 320 20 20 50 50 <1.5 <1.0 <2.2 - - 200 3 3 PR.420-3P 420 20 20 50 50 <2 <1.5 <2.4 - - 200 3 3 PR.550-3P 550 20 20 50 50 <2.5 <1.8 <2.5 - - 200 3 3 PR.690-3P 690 20 20 50 50 <3 <2.8 <3.2 - - 200 3 3 PR.150-4P 150 20 20 50 50 <0.8 <0.6 <1.7 - - 200 4 4 PR.275-4P 275 20 20 50 50 <1.4 <0.9 <2.1 - - 200 4 4 PR.320-4P 320 20 20 50 50 <1.5 <1.0 <2.2 - - 200 4 4 PR.420-4P 420 20 20 50 50 <2 <1.5 <2.4 - - 200 4 4 PR.550-4P 550 20 20 50 50 <2.5 <1.8 <2.5 - - 200 4 4 PR.690-4P 690 20 20 50 50 <3 <2.8 <3.2 - - 200 4 4 SURGE ARRESTER CLASS II 13

FINPR SERIES Surge Arrester Class II Nominal Voltage Vac L-L (L-N) Nominal Discharge (In, KA) 8/20 Max Discharge Current (Imax, KA) Voltage Protection Rated (kv) SCCR Electrical FINPR (ka) Diagram L-N N-PE L-N N-P @In @VPR L-N@MLV N-PE@MLV L-N@1.2/50 PR.150-PN 208 (150) 20 20 50 50 <0.8 <0.6 <1.7 <1.2 <1.5 200 5 2 PR.275-PN 320 (275) 20 20 50 50 <1.4 <0.9 <2.1 <1.7 <1.5 200 5 2 PR.320-PN 400 (320) 20 20 50 50 <1.5 <1.0 <2.2 <1.7 <1.5 200 5 2 PR.385-PN 480 (385) 20 20 50 50 <2 <1.5 <2.4 <1.7 <1.5 200 5 2 PR.420-PN 600 (420) 20 20 50 50 <2.5 <1.8 <2.5 <1.7 <1.5 200 5 2 PR.150-3PN 208 (150) 20 20 50 50 <0.8 <0.6 <1.7 <1.2 <1.5 200 6 4 PR.275-3PN 320 (275) 20 20 50 50 <1.4 <0.9 <2.1 <1.7 <1.5 200 6 4 PR.320-3PN 400 (320) 20 20 50 50 <1.5 <1.0 <2.2 <1.7 <1.5 200 6 4 PR.385-3PN 480 (385) 20 20 50 50 <2 <1.5 <2.4 <1.7 <1.5 200 6 4 PR.420-3PN 600 (420) 20 20 50 50 <2.5 <1.8 <2.5 <1.7 <1.5 200 6 4 Mechanical Case ELECTRICAL DIAGRAM SCHEMATIC 1 SCHEMATIC 2 SCHEMATIC 3 SCHEMATIC 4 SCHEMATIC 5 SCHEMATIC 6 MECHANICAL DIMENSIONS (mm) CASE 1 CASE 2 CASE 3 CASE 4 14 SURGE ARRESTER CLASS II

EMG (G) 20 SERIES Surge Arrester Class II+III The Enerdoor surge arrester EMG (G) 20 series provides advanced surge protection. This device is designed for maximum discharge of 40 ka, meets the UL 1449 3 rd edition and IEC61643-11:2011 Standards, and includes a visual and remote contact indicator. GENERAL CHARACTERISTICS Class category IEC/VDE II+III / C+D Operating temperature range -40 C + 80 C Operating humidity range 0 ~ 90% Response time 100 ns Backup fuse 125 Amps gl/gg (only required if not in the main) Enclosure material Thermoplastic, UL94 V-0 Mounting 35mm DIN rail according to the EN50022/DIN46277-3 Standard Max size of connecting wire Single-strand 35mm 2 (or # 2AWG) Multi-strand 25mm 2 (or # 4AWG) Remote alarm contact type Isolated form C Switching capability Un/In AC: 250V/0.5A DC: 250V/0.1A Max size of connecting wire Max 1.5mm 2 (or #16AWG) EMG (G) 20 Nominal Voltage Vac L-L (L-N) Nominal Discharge (In, KA) 8/20 Max Discharge Current (Imax, KA) L-N N-PE L-N N-PE Voltage Protection Rated (kv) @In @VPR N-PE (1.2/50) EMG.150-1P20 150 20-40 - <0.6 <0.5-1 EMG.275-1P20 275 20-40 - <1.2 <0.8-1 EMG.320-1P20 320 20-40 - <1.3 <0.9-1 EMG.420-1P20 420 20-40 - <1.6 <1.1-1 EMG.150-3P20 150 20-40 - <0.6 <0.5-2 EMG.275-3P20 275 20-40 - <1.2 <0.8-2 EMG.320-3P20 320 20-40 - <1.3 <0.9-2 EMG.420-3P20 420 20-40 - <1.6 <1.1-2 EMG.150-4P20 150 20-40 - <0.6 <0.5-3 EMG.275-4P20 275 20-40 - <1.2 <0.8-3 EMG.320-4P20 320 20-40 - <1.3 <0.9-3 EMG.420-4P20 420 20-40 - <1.6 <1.1-3 EMGG.150-3P20N20 208 (150) 20 20 40 40 <0.6 <0.5 <0.8 4 EMGG.275-3P20N20 320 (275) 20 20 40 40 <1.2 <0.8 <1.5 4 EMGG.320-3P20N20 400 (320) 20 20 40 40 <1.3 <0.9 <1.5 4 EMGG.420-3P20N20 600 (420) 20 20 40 40 <1.6 <1.1 <1.5 4 Case SURGE ARRESTER CLASS II+III 15

EMG (G) 20 SERIES Surge Arrester Class II+III ELECTRICAL DIAGRAM SCHEMATIC 1 SCHEMATIC 2 SCHEMATIC 3 SCHEMATIC 4 MECHANICAL DIMENSIONS (mm) CASE 1 CASE 2 CASE 3 CASE 4 16 SURGE ARRESTER CLASS II+III

EMG (G) 40 SERIES Surge Arrester Class II+III The Enerdoor surge arrester EMG (G) 40 series provides advanced surge protection. This device is designed for maximum discharge of 80 ka, meets the UL 1449 3 rd edition and IEC61643-11:2011 Standards, and includes a visual and remote contact indicator. GENERAL CHARACTERISTICS Class category IEC/VDE II+III / C+D Operating temperature range -40 C + 80 C Operating humidity range 0 ~ 90% Response time 100 ns Backup fuse 200 Amps gl/gg (only required if not in the main) Enclosure material Thermoplastic, UL94 V-0 Mounting 35mm DIN rail according to the EN50022/DIN46277-3 Standard Max size of connecting wire Single-strand 35mm 2 (or # 2AWG) Multi-strand 25mm 2 (or # 4AWG) Remote alarm contact type Isolated form C Switching capability Un/In AC: 250V/0.5A DC: 250V/0.1A Max size of connecting wire Max 1.5mm 2 (or #16AWG) EMG (G) 40 Nominal Voltage Vac L-L (L-N) Nominal Discharge (In, KA) 8/20 Max Discharge Current (Imax, KA) L-N N-PE L-N N-PE Voltage Protection Rated (kv) @In @VPR N-PE (1.2/50) EMG.150-1P40 150 40-80 - <0.6 <0.5-1 EMG.275-1P40 275 40-80 - <1.2 <0.8-1 EMG.320-1P40 320 40-80 - <1.3 <0.9-1 EMG.420-1P40 420 40-80 - <1.6 <1.1-1 EMG.150-3P40 150 40-80 - <0.6 <0.5-2 EMG.275-3P40 275 40-80 - <1.2 <0.8-2 EMG.320-3P40 320 40-80 - <1.3 <0.9-2 EMG.420-3P40 420 40-80 - <1.6 <1.1-2 EMG.150-4P40 150 40-80 - <0.6 <0.5-3 EMG.275-4P40 275 40-80 - <1.2 <0.8-3 EMG.320-4P40 320 40-80 - <1.3 <0.9-3 EMG.420-4P40 420 40-80 - <1.6 <1.1-3 EMGG.150-3P40N40 208 (150) 40 40 80 80 <0.6 <0.5 <0.8 4 EMGG.275-3P40N40 320 (275) 20 40 80 80 <1.2 <0.8 <1.5 4 EMGG.320-3P40N40 400 (320) 40 40 80 80 <1.3 <0.9 <1.5 4 EMGG.420-3P40N40 600 (420) 40 40 80 80 <1.6 <1.1 <1.5 4 Case SURGE ARRESTER CLASS II+III 17

EMG (G) 40 SERIES Surge Arrester Class II+III ELECTRICAL DIAGRAM SCHEMATIC 1 SCHEMATIC 2 SCHEMATIC 3 SCHEMATIC 4 MECHANICAL DIMENSIONS (mm) CASE 1 CASE 2 CASE 3 CASE 4 18 SURGE ARRESTER CLASS II+III

EMG (G) 60 SERIES Surge Arrester Class II+III The Enerdoor surge arrester EMG (G) 60 series provides advanced surge protection. This device is designed for maximum discharge of 120 ka, meets the UL 1449 3 rd edition and IEC61643-11:2011 Standards, and includes a visual and remote contact indicator. GENERAL CHARACTERISTICS Class category IEC/VDE II+III / C+D Operating temperature range -40 C + 80 C Operating humidity range 0 ~ 90% Response time 100 ns Backup fuse 315 Amps gl/gg (only required if not in the main) Enclosure material Thermoplastic, UL94 V-0 Mounting 35mm DIN rail according to the EN50022/DIN46277-3 Standard Max size of connecting wire Single-strand 35mm 2 (or # 2AWG) Multi-strand 25mm 2 (or # 4AWG) Remote alarm contact type Isolated form C Switching capability Un/In AC: 250V/0.5A DC: 250V/0.1A Max size of connecting wire Max 1.5mm 2 (or #16AWG) EMG (G) 60 Nominal Voltage Vac L-L (L-N) Nominal Discharge (In, KA) 8/20 Max Discharge Current (Imax, KA) L-N N-PE L-N N-PE Voltage Protection Rated (kv) @In @VPR N-PE (1.2/50) EMG.150-1P60 150 60-120 - <0.6 <0.5-1 EMG.275-1P60 275 60-120 - <1.2 <0.8-1 EMG.320-1P60 320 60-120 - <1.3 <0.9-1 EMG.420-1P60 420 60-120 - <1.6 <1.1-1 EMG.150-3P60 150 60-120 - <0.6 <0.5-2 EMG.275-3P60 275 60-120 - <1.2 <0.8-2 EMG.320-3P60 320 60-120 - <1.3 <0.9-2 EMG.420-3P60 420 60-120 - <1.6 <1.1-2 EMG.150-4P60 150 60-120 - <0.6 <0.5-3 EMG.275-4P60 275 60-120 - <1.2 <0.8-3 EMG.320-4P60 320 60-120 - <1.3 <0.9-3 EMG.420-4P60 420 60-120 - <1.6 <1.1-3 EMGG.150-3P60N60 208 (150) 60 60 120 120 <0.6 <0.5 <0.8 4 EMGG.275-3P60N60 320 (275) 60 60 120 120 <1.2 <0.8 <1.5 4 EMGG.320-3P60N60 400 (320) 60 60 120 120 <1.3 <0.9 <1.5 4 EMGG.420-3P60N60 600 (420) 60 60 120 120 <1.6 <1.1 <1.5 4 Case SURGE ARRESTER CLASS II+III 19

EMG (G) 60 SERIES Surge Arrester Class II+III ELECTRICAL DIAGRAM SCHEMATIC 1 SCHEMATIC 2 SCHEMATIC 3 SCHEMATIC 4 MECHANICAL DIMENSIONS (mm) CASE 1 CASE 2 CASE 3 CASE 4 20 SURGE ARRESTER CLASS II+III

FINPRS SERIES Surge Arrester Class II The Enerdoor surge arrester FINPRS series provides advanced surge protection for common mode and common mode + differential mode DC surge. This device is designed for maximum discharge of 50 ka, meets the UL 1449 3 rd edition and IEC61643 11:2011 Standards, and includes a visual and remote contact indicator. GENERAL CHARACTERISTICS Class category IEC/VDE II / C Operating temperature range 40 C + 80 C Operating humidity range 0 ~ 90% Response time L N 25 ns Backup fuse 125 Amps gr/gpv (only required if not in the main) Enclosure material Thermoplastic, UL94 V 0 Mounting 35mm DIN rail according to the EN50022/DIN46277-3 Standard Max size of connecting wire Single strand 35mm 2 (or # 2AWG) Multi strand 25mm 2 (or # 4AWG) Remote alarm contact type Isolated form C Switching capability Un/In AC: 250V/0.5A DC: 250V/0.1A Max size of connecting wire Max 1.5mm 2 (or #16AWG) FINPRS Nominal Voltage Vdc Max Continuos Operating Vdc Nominal Discharge (In, KA) 8/20 Max Discharge Current Voltage Protection Rated (kv) L-N L-N @In @VPR L-N@MLV Electrical Mechanical.500-M-CS 500 550 20 50 <2.0 <1.5 <2.4 1 1.600-M-CS 600 745 20 50 <2.5 <1.8 <2.8 1 1.600-M-CDS 600 700 20 50 <2.8 <1.8 <4.2 2 2.750-M-CDS 750 840 20 50 <3.0 <2.0 <4.4 2 2.1000-M-CDS 1000 1120 20 50 <4.0 <3.0 <4.8 2 2.1200-M-CDS 1200 1490 20 50 <5.0 <3.6 <5.6 2 2 Case SURGE ARRESTER CLASS II 21

FINPRS SERIES Surge Arrester Class II ELECTRICAL DIAGRAM SCHEMATIC 1 SCHEMATIC 2 MECHANICAL DIMENSIONS (mm) CASE 1 CASE 2 22 SURGE ARRESTER CLASS II

Transformers and Line Reactors RFI Filters Voltage Stabilizers Passive and Active Harmonic Filters Motor Protection

10-2015 USA ENERDOOR Inc Toll Free 1-877-778-2875 Phone 1-207-210-6511 Fax 1-207-210-6512 info@enerdoor.com www.enerdoor.com GERMANY ENERDOOR Gmbh Phone +49 (0) 6642 223692 Fax +49 (0) 6642 223558 info@enerdoor.de www.enerdoor.de SWITZERLAND ENERDOOR SA Phone +41 (0) 91 9228060 Fax +41 (0) 91 9228061 info@enerdoor.ch www.enerdoor.ch ITALY FINMOTOR Srl Phone +39 02 4891 0020 Fax +39 02 4891 0053 info@finmotor.com www.finmotor.com HUNGARY EICHHOFF ELEKTRO Kft Phone +36 27 511180 Fax +36 27 511187 info@eichhoff-elektro.com www.eichhoff-kft.com