QSSE, QSSEX INDUSTRIAL Battery Chargers

Similar documents
QPET, QPETXU Battery Chargers

OBE, OBEXU, ON BOARD Battery Chargers

OBAE, OBAEXU, ON BOARD Battery Chargers

O P E R A T I N G I N S T R U C T I O N S

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS Ext. 322

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

LESTRONIC II BATTERY CHARGER MODEL 19740

FULLY AUTOMATIC SCR BATTERY CHARGER

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS

36 VOLT AUTOMATIC BATTERY CHARGER PART NO

LESTRONIC II BATTERY CHARGER MODEL 07210

FULLY AUTOMATIC SCR BATTERY CHARGERS

OWNERS MANUAL BATTERY CHARGER MODEL 19300

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

48 VOLT FULLY AUTOMATIC BATTERY CHARGER MODEL 25320

MODEL 6017 OPERATOR'S MANUAL

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

CLEAN POWER TM CPS Series Operator s Manual

24 VOLT DUAL MODE WHEELCHAIR BATTERY CHARGER MODEL TYPE 24EL8 E&J PRODUCT NO

2/10/50 AMP 12 VOLT BATTERY CHARGER/ ENGINE STARTER

LESTRONIC II FULLY AUTOMATIC BATTERY CHARGER MODEL TYPE 36LC36-8ET

User s Manual. Automatic Switch-Mode Battery Charger

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

IMPORTANT SAFETY INSTRUCTIONS

BusPro Series Instruction Manual

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

innovations in battery charging

Safety, Installation And Operating Instructions For The Following Battery Charger Models: i2412, i3612, i4809, i2425, i3625, and i4818

10 AMP ON BOARD BATTERY CHARGER

OWNER S MANUAL. Model YUA2AMPCH 2 AMP Dual-Bank Automatic Battery Charger & Maintainer READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

AUTO CHARGE D PUMP PLUS

SP6. Automatic Battery Charger. Model

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

POWERDRIVE_TYPE LEAD ACID BATTERY POWER-SUPPLY-CHARGER

USER S MANUAL Industrial Battery Charger Important Safety, Installation, Operation, and Maintenance Instructions

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

BATTERY SAVER LOW RIPPLE HO

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

Models: SP3, SPSS3 Automatic Battery Charger

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

OWNER S MANUAL Revised JULY 2, IMPORTANT: Read this manual before installing, operating, or servicing this product.

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

600 Amp Battery Jumper with Air Compressor

Installation and Operating Instructions (for chargers shown below)

USER S MANUAL Industrial Battery Charger Important Safety, Installation, Operation, and Maintenance Instructions

Snap-on BC4200B Fast 420 Battery Charger User's Manual

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

A48 / A48B (base plate) BATTERY CHARGER

High Frequency SMT Golf Car Chargers Battery Tender Battery Charger Models: 12 Volt 20 Amp, 24 Volt 20 Amp, 36 Volt 15 Amp, 48 Volt 10 Amp

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

LESTRONIC II AUTOMATIC BATTERY CHARGER MODEL TYPE 36LC21-6ET

VAc A. Rc Ah. Table of contents. OpERATION MAINTENANcE. Safety... 2 Specifications... 6 Operation Maintenance Warranty...

OWNER S MANUAL AC150 MANUAL TIMER CHARGE CONTROL

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

February EN-B POWER CHARGE PSC-700. Power Supply / Maintenance Charger for 12-volt Batteries/Systems INSTRUCTION MANUAL

BATTERY & STARTER ANALYSER (BSA-12) User Manual

Operating Instructions for PAC800 Battery Charger

innovations in battery charging

User Guide IGD Series

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

USER S MANUAL Model Important Safety, Installation, Operation, and Maintenance Instructions

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

Installation and Operating Instructions (for chargers shown below)

PUMP PLUS 1000 PLC MODEL #: PP AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

FJC, Inc. Part # V BATTERY Charger/Maintainer INSTRUCTION MANUAL SAFETY WARNINGS AND PRECAUTION

Installation and Operating Instructions (for chargers shown below)

Go Power! Manual. GP-Smart Charger

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

WARNING: When using tool, basic safety precautions should always be followed to reduce the risk of personal injury and damage to the equipment.

DISCHARGER-ANALYZER BDX USER'S MANUAL

Battery. Charger Model: Save Important Safety Instructions

SUNC3000 / Item #40885

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

USER S MANUAL Model Important Safety, Installation, Operation, and Maintenance Instructions

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

installation and operating instructions for the following xtreme Battery chargers:

LPC 40 MODEL #: LOW PROFILE CHARGER WITH PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

High Capacity Battery Charger

AUTOMATIC SUBMERSIBLE UTILITY PUMP

COLT CELL BATTERY CHARGER Installation and Operating Instructions

AUTOMATIC BURNISHER MODEL FURY 21 HSB

INTELLIGENT BATTERY CHARGER/MAINTAINER

DC TO AC POWER INVERTER PWRINV150W INSTRUCTION MANUAL

POWERDRIVE BATTERY CHARGER OWNER S MANUAL

DC to AC Power Inverters

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

Transcription:

C O R P O R A T IO N O P E R A T I N G I N S T R U C T I O N S QSSE, QSSEX INDUSTRIAL Battery Chargers INTRODUCTION The QSE line are electronically controlled float chargers. The batteries are brought to the gassing threshold, and held indefinitely. Finish current can be as low as 1 amp depending on battery size and age. Designed for wet starting batteries, or gel type batteries. SOME APPLICATIONS Stand-by power, UPS systems, any application where batteries must be kept in a full state of charge IMPORTANT: DO NOT USE THIS CHARGER UNTIL YOU HAVE READ ALL THE INSTRUCTIONS. INITIAL INSTALLATION: Before making AC connections, refer to the AC requirements labeled on the charger. If your charger is not equipped with an AC plug (a 220 volt model) have a qualified electrician install one. CAUTION: To reduce the risk of fire, use this charger only on circuits provided with a maximum of 30 ampere branch circuit protection (circuit breaker or fuse), in accordance with the National Electric Code, ANSI/NFPA 70, and all local codes and ordinances. GROUNDING INSTRUCTIONS: This battery charger must be grounded to reduce the risk of electric shock. If the charger is equipped with a grounding type plug, it must be plugged into a nominal 115 volt, 60 Hertz circuit. If the charger is supplied with no plug, have a qualified service person install one. WARNING: Improper connection of the equipment grounding conductor can result in a risk of an electric shock. DO NOT USE THIS CHARGER ON A TWO POLE UNGROUNDED OUTLET OR ATTEMPT TO BREAK OFF THE GROUND PRONG FOR USE ON A RECEPTACLE OR EXTENSION CORD NOT HAVING A GROUND. The use of an extension cord with this charger should be avoided. The use of an improper extension cord result in a risk of a fire or electric shock. If an extension cord must be used, make sure it is in good condition. Use a three conductor cord no smaller than 12 AWG. And keep it as short as possible. Locate all cords so that they will not be stepped on, tripped over, or otherwise subjected to damage or stress. Do not operate this charger if it shows any signs of physical damage. 1 Quick Charge Corp. 1032 S.W. 22nd St. Oklahoma City, OK. 73109 800 658-2841

PROPER CARE AND USE OF BATTERIES: CAUTION: Always wear protective eye shields and clothing when working with batteries. Batteries contain acids which can cause bodily harm. Do not put wrenches or other metal objects across the battery terminal or battery top. Arcing or explosion of the battery can result. Do not wear jewelry when working around batteries. Arcing can cause sever burns. New batteries will not deliver their full performance until after several cycles. The tops of the batteries and battery hold downs must be kept clean and dry at all times to prevent excessive self discharge and flow of current between the battery post and frame. Maintain the proper electrolyte level by adding water when necessary. Never allow the electrolyte level to fall below the top of the battery plates. Electrolyte levels fall during discharge and rise during charging. Therefore, to prevent the overflow of electrolyte when charging, add water ONLY AFTER the batteries have been fully charged DO NOT OVERFILL. Old batteries require more frequent additions of water than do new batteries. Do not over discharge the batteries. Excessive discharge can cause polarity reversal of individual cells resulting in complete battery failure. Provide adequate ventilation for the batteries and charger. Do not obstruct the flow of cooling air around the charger. Provide at least 1" of space around charger. Do not allow clothing, blankets or other material to cover the charger. WARNING: Chargers can ignite flammable materials and vapors. Do not use near fuels, grain, dust, solvents, or other flammable s. CAUTION: Before connecting the charger to the batteries, make sure the battery pack is of the same voltage rating of the charger. If you are unsure, count the number of cells on the battery pack and multiply by two. This figure should be the same as the DC voltage rating of the charger. (see ratings label on charger). Below is an illustration of Parallel and Series battery packs. + Red Charge Lead + + + Black Charge Lead - - - - Parallel When batteries are connected in parallel, the battery amp hour rating is additive, and the voltage remains the same. Example: Two 180 amp hour, 12 volt batteries would equal 12 volts, and 360 amp hours capacity. Series When batteries are connected in series, the voltage is additive, and the amp hour rating remains the same. Example: Two 180 amp hour, 12 volt batteries would equal 24 volts, and 180 amp hours of capacity. Red Charge Lead Black Charge Lead 2

WARNING: Make sure the DC output leads, clamps, or connector are all in good working condition. DO NOT USE THIS CHARGER IF: The DC output clamps, or connector is loose, worn or does not make good contact; The leads are cut or have exposed wires; The DC output leads or connector/clamps feel hot when used. Using this charger with any of the above symptoms could result in a fire, property damage, or personal injury. Have a qualified service person make the necessary repairs. Repairs should not be made by people who are not qualified. NORMAL OPERATION 1). Plug charger into battery pack. The BATTERY LED should light, indicating DC continuity. 2). Plug charger in AC power, and move power switch to ON position. The AC POWER LED should light, and cooling fan should be heard. WARNING: If the cooling fan does not come on, the charger should be powered down. Operating the charger without the cooling fan will result in transformer and or rectifier burnout. Have the charger serviced by a qualified service person. 3). Initially, the ammeter will read the maximum output of the charger. As the batteries become charged, the ammeter will work it s way down, and the voltage will rise. When the ammeter reads around 25 amps, the fan will shut off, and the END CYCLE LED will come on. The charger should be left ON until the ammeter declines to zero, or very near zero. The battery voltage will level off at 2.3 volts per cell. The charger may be left connected indefinitely in this condition, but the water level on wet batteries should be checked periodically. If after 16 hours, the ammeter does not read zero, or very near zero, this indicates one or more defective cells in the battery. As a battery ages, this condition worsens. Do not leave the charger unattended for long periods with this condition. Replace battery, or defective cell. 5). To discontinue charging, move switch to the OFF position. Remove clamps from battery or unplug connector. WARNING: Do not disconnect the DC output clamps or unplug connector from the batteries when the charger is on. The resulting arcing could cause the batteries to explode. TROUBLE SHOOTING: CAUTION: DO NOT DISASSEMBLE THE CHARGER. Incorrect assembly may result in a risk of electric shock or fire. Contact factory. DANGER: To reduce the risk of electric shock, always disconnect both the AC power supply cord and the output leads or connector before attempting any maintenance cleaning. 3

1). BATTERY LED DOES NOT COME ON WHEN BATTERY CONNECTION IS MADE Check lead connections to clamps, make sure they are not broken, or corroded. The battery voltage may be too low to light the LED and start the charger. 2). AC POWER LED WILL NOT COME ON WHEN POWER SWITCH IS ON Check that you are plugged into a live circuit. Check AC cord, plug and receptacle for damage. These chargers are fused internally. Check fuse card mounted on ammeter. If it is blown, contact factory for a new one, and have a qualified service person install it. 3). FUSE ON CHARGER OR AC LINE BREAKER BLOWS The charger may be shorted internally. Charging a battery with a lower voltage rating than the charger will cause an overload, and damage to battery and charger. 4). NO POWER IS PRESENT ACROSS THE DC LEADS WHEN A VOLT METER IS CONNECTED Good. The charger will not turn on until the clamps are connected to the battery. 5). BATTERIES DON T RECEIVE FULL CHARGE The battery you are charging may be too large for the charger, or if you have the charger plugged into a long extension cord that is too small, a voltage drop will cause a decrease in charger output, extending charge times. If you are charging batteries that require gassing, this charger will not charge above the gassing threshold. 6). THE AC POWER & BATTERY LED s COME ON, BUT THE AMMETER DOES NOT MOVE. The battery may be sulfated so much, internal resistance is too high for current to flow. Sometimes leaving the charger ON will eventually break loose the sulfate and allow the battery to accept the charge. If not, a battery specialist may be able to recover the battery. 7). AMMETER WILL NOT GO TO ZERO A battery with one, or more shorted cells will draw current continuously. Replace the defective cell, or battery. Gassing by the shorted cell(s) will cause a hazardous condition, and performance will be greatly reduced. 8). FAN DOES NOT OPERATE Have a qualified service person replace the fan 4

QUICK CHARGE QSSE Battery Chargers LIMITED WARRANTY Quick Charge corporation warrants the QSSE line of chargers for three (3) years from the date of purchase. After the warranty period, chargers returned to the factory for repair will be charged a minimum rate of $25.00. Charger will be returned, freight and repair charges, C.O.D. unless other arrangements have been made This warranty covers all defects in manufacture and performance, provided the unit is operated in compliance with manufacture s operating instructions. For repairs to be made at the Quick Charge factory, a charger and/or component(s) should be sent, freight prepaid to Quick Charge at: Quick Charge Corp. 1032 S.W. 22nd St. Oklahoma City, OK. 73109 Quick Charge, will at it s option, repair or replace the charger or component in question. The repaired item will then be returned, freight prepaid by Quick Charge. This warranty is void if the charger or component have been altered, changed, or repaired by anyone not authorized by Quick Charge, or if the charger or component, have been subjected to misuse, negligence, or harsh environmental conditions. (Except those chargers designed for such conditions) If returning the charger to the factory is not practical, replacement parts may be shipped to the customer for field repair at no charge. On parts such as circuit boards, the customer will be required to return the board suspected to be defective to Quick Charge, freight prepaid. If such defective parts are not returned, the customer will be invoiced for the repair parts. Field repairs are made at the user s own risk. Authorization by Quick Charge to repair refers to maintaining the warranty only. Quick Charge assumes no responsibility or liability for field servicing, and shall not be responsible for incurred travel or labor charges. Quick Charge corporation shall not in any event be liable for the cost of any special, indirect or consequential damages to anyone, product or thing. This warranty is in lieu of all other warranties expressed or implied. Quick Charge neither assumes nor authorizes any representative or other person to assume for us any liability in connection with the sale of this product. 5

This document was created with Win2PDF available at http://www.daneprairie.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only.