ATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech

Similar documents
ATEX instruction APP S 674 pumps APP S , APP S and APP S

APP pump instruction APP and APP 16-22

APP pump instruction APP 21-43

APP S pumps APP S / APP S / APP S 21-38

PAHT pump PAHT X

2/4/6.3, PAH 10/12.5, PAH 50/63/70/80/100 pumps

Disassembling and assembling PAH , PAHT and PAHT G

PAHT pumps / PAHT G pumps / ATEX PAHT G pump

Changing pistons APP and APP 16-22

APP S 674 pumps APP S / APP S APP S

PAH / PAHT / PAHT G pumps

Changing pistons APP 21-43

MAKING MODERN LIVING POSSIBLE. Data sheet. Data sheet APP ro-solutions.com

APP pumps APP / APP / APP / APP (W) / APP / APP / APP 21-43

MAKING MODERN LIVING POSSIBLE. Data sheet. Data sheet APP ro-solutions.com

Tel: +44 (0) E mail: Web: Data sheet. APP pumps APP ro-solutions.com

3/2-Way Zone-Drain-Valves VDHT 2E, VDHT 15E and VDHT 15EC

Parallel coupled APP pumps

Disassembling and assembling isave 21

APP pumps APP / APP / APP (W) / APP / APP / APP Lenntech. Data sheet

Solenoid valve VDHT Standard BSP (British Standard Pipe)

Data sheet APP

Nessie High-Pressure Pumps for technical water, type PAH

Energy Recovery Device isave 21-40

MAKING MODERN LIVING POSSIBLE. Product overview. . Energy efficient. Reliable. Very long service intervals HIGH-PRESSURE SYSTEMS

Solenoid coil for control in potentially explosive areas Type BZ

Pumps and pumping units SL i & Micro C

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Operating Instructions

Series TMM Axial Piston Motor. Technical Information

Explosion-Proof Motors Increased Safety

Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC and VDH 30EC "Soft-Charge"

Swing Piston Compressors and Vacuum Pumps

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

TopGear TG L/RBS-series

Installation Instructions In-bottom/Out-back Cooling Kit for E4h Drives VLT FC Series FC 102, FC 103, FC 202, and FC 302

Crankcase pressure regulator Type KVL

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Technical Data. Dimensions

Ex m Solenoid Operator Type 0519

Crankcase pressure regulator Type KVL

Installation Instructions In-back/Out-back Cooling Kit for D5h/D6h and D7h/D8h Enclosures VLT Series FC 102, FC 202, and FC 302

SonoSensor 30 Ultrasonic flow meter for heating and cooling applications

ATEX instruction for OMR Special conditions for safe use

Explosion protected terminal boxes type, GHG 72.

INDUSTRY PROCESS AND AUTOMATION SOLUTIONS. Technical Bulletin

VALIADIS S.A. HELLENIC MOTORS

Data sheet. Data sheet. APP pumps APP APP Pumps APP 53 / APP 65 / APP 78 / APP 86. ro-solutions.com. hpp.danfoss.com

SITRANS P measuring instruments for pressure

Instruction Manual. for Heating Cables and Cold Leads Type and Catalogue no and Hemstedt GmbH.

Filter solutions for Danfoss PAH, APP and CLP pumps

ELIMINATOR Hermetic filter drier Types DML and DCL

Oil pump type RSA. Catalogue 1. Burner Components

ELIMINATOR Hermetic filter drier Types DCL and DML

Direct-acting 3/2 way plunger valve

ATEX instruction for OMS, OMT and OMV Special conditions for safe use

Installation Instructions 500 A Current Sensor Kit for F1 F4/F8 F13 Enclosure Sizes VLT Series FC 102, FC 202, and FC 302

Data sheet. Data sheet. APP pumps APP APP Pumps APP 53 / APP 65 / APP 78 / APP 86. ro-solutions.com

Installation Instructions 300 A Current Sensor Kit for D1h/D3h/D5h/D6h Enclosure Sizes VLT Series FC 102, FC 103, FC 202, and FC 302

Powerful centrifugal fans for universal use: The product ranges TEM and REM

FILTER, REGULATOR AND FILTER/REGULATOR stainless steel 316L compact 1/4, high flow 1/4-1/2

Explosion proof electric motor For Fuel dispensing application. Main characteristic

SERIES R - MD MOR & GOR

ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB

Resistance thermometer Model TR10-B, for additional thermowell

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems

PAH, PAHT, PAHT G pumps PAH , PAHT and PAHT G Disassembling and assembling

A good connection. International approvals.

Resistance thermometer Model TR10-E, for additional thermowell

Series 20 Axial Piston Pumps. Technical Information

Series 20 Axial Piston Pumps. Technical Information

SSM Floor Heating Manifold

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

SonoSensor 30 Ultrasonic flow sensor

manual addendum ROBUS Ex

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Installation Instructions Bus Bar Kit for 6-pulse, 4-drive System VLT Series FC 102, FC 202, and FC 302. Description. Kit Part Number.

Unused flameproof threads for cable glands have to be closed with certified plugs.

Installation Guide. DEVIreg 527. Electronic Time Regulator.

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

Special Radial piston pumps Type SRK-ATEX

Product Overview. Rotary Encoders for Potentially Explosive Atmospheres (ATEX)

Danfoss VDHT Solenoid Valves WATER SOLUTIONS

Operating Instructions

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35

TAP Gear Pumps Technical Information Tap Gear Pumps Standard Flange. OpenCircuitGear. Installation dimensions. Specification Data

Switching DC Power Supply

ANNEX No 1. C 17/05/2006 SGA112B TERMINAL BOX ARRANGEMENT Ex e, Ex na &Ex td V (OPTION 2)

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

DSA HIGH EFFICIENCY DROPLET SEPARATOR DROPLET SEPARATOR DSA. With heated vanes

Technical Information Series 45 G Frame powersolutions.danfoss.com

Gas-actuated thermometer with switch contacts For sanitary applications, stainless steel version Model 74

UD and UC Gear pump unit

Thermocouples Model TC10-B, for Additional Thermowell

Transcription:

MAKING MODERN LIVING POSSIBLE Instruction ATEX instruction for APP 0.6-10.2 / PAH 2-100 PAHT G 2-90 / PAH 25-80 Tech danfoss.high-pressurepumps.com

Table of Contents 1. Common demands for Category 2 and 3 installations...3 2. Design guide for Category 2 (zone 1) systems...5 2.1 Temperature sensor...5 2.2 Pressure sensor...6 2.3 Preferred system design and P&ID for Category 2 pump....7 3. Design guide for Category 3 (zone 2) systems....9 3.1 Pressure sensor...9 3.2 Preferred system design and P&ID for Category 3...9 4. EU Declaration of Conformity....11 The Danfoss pumps are marked for application in Group II Category 2 or Category 3 systems. II 3 G c T6 II 2 G c b T6 Example ATEX pump label This document describes how to integrate a pump in a system depending on the Category demand. Equipment groups (Annex I of the EC-Directive 94/9/EC) Group I (mines, mine gas) Group II (other explosive atmospheres gas) Category M Category 1 Category 2 Category 3 1 2 G (gas) (Zone 0) For equipment providing a very high level of protection when endangered by an explosive atmosphere For equipment providing a high level of protection when likely to be endangered by an explosive atmosphere For equipment providing a very high level of protection when used in areas where an explosive atmosphere is very likely to occur G (gas) (Zone 1) For equipment providing a high level of protection when used in areas where an explosive atmosphere is likely to occur G (gas) (Zone 2) For equipment providing a normal level of protection when used in areas where an explosive atmosphere is less likely to occur 2 180R9113 / DKCFN.PI.010.A6.02 / 521B1026 / 02.2013

1. Common demands for Category 2 and 3 installations This instruction is a supplement to existing product instruction as ATEX components are subject to some limitations compared to standard components. The limitations are described in this ATEX instruction. Validity: Approvals are only related to water as fluid. If other fluids are used these must be non-flammable fluids. The pumps are designed to pump liquids and not gasses! It is the user s responsibility to ensure that the pump is filled with fluid during start-up and operation. Fluids: If the pump is to operate on other fluids than water, please contact Danfoss. Other operation and maintenance conditions might apply. Minimum suction pressure: The user must always ensure that the pump is filled with the fluid to be pumped. The pumps must always be operated with a positive head on suction port. The allowable minimum and maximum inlet pressure for the suction port can be found in the pump data sheet. Maximum discharge pressure: It is the user s responsibility that the pump discharge pressure does not exceed the max continuous discharge pressure stated in the pump data sheet. Temperature: The pump is not to be operated in systems where the fluid temperature exceeds 50 C/122 F. Filtration: The fluids entering the pump must as a minimum always be filtered according to the specification found in the pump data sheet. External impacts due to: Gases: The pumps are made in materials resistant to most common gases. The user of the pump must ensure that materials used are resistant to the gases applied. Assembly of pump drive unit: Motor - Pump assembly and system integration: When assembling the pump with the bell housing, flexible couplings and motor, it is the builder s responsibility that the parts used conform to the ATEX directive and that the components are assembled and running according to the operational data/design found in product data sheets and instructions. All parts must be potential equalized, in a Category 2 and 3 system, all parts must be potential equalized by electrical wires, according to local regulations. The wire gauge must be equal to the wire gauge applied in the supply of the electric motor and may as a minimum not be smaller than 16mm 2. (EN 60079-0 Item15.4). It is important to ground connect each component directly to a base point. Grounding connector Grounding connector, mark with Grounding connector, mounting bolt 180R9113 / DKCFN.PI.010.A6.02 / 521B1026 / 02.2013 3

Choice of bell housing and coupling The material for the bell housing can be steel, stainless steel or aluminium with a magnesium content below 7,5%. The bell housing must have an inspection and a drain hole. The drain hole must be placed at the lowest point to ensure the fluid can get out if there is a small leak from the pump shaft seal. The distance between bell housing and the rotating parts must be at least 5mm. Coupling for use in hazardous areas are marked with regard to the respective permissible conditions of use. Aluminium as coupling material is generally excluded for explosive areas. See special conditions for safe use in coupling operation- and ATEX instruction from coupling supplier. D C B A Mounting of bell housing and coupling: 1. Mount the coupling on pump shaft. Ensure an air gap between end of coupling and pump flange of min. 4 mm (0.16 in) D. 2. Mount the bell housing on pump. Secure bolts with the right torque - see pump instruction. 3. Measure the longest distance A from top of bell housing to the bottom of coupling claw. 4. Mount the coupling on motor shaft. Ensure the coupling and motor flange are not in contact with each other. 5. Measure from motor flange to the top of the coupling. That measurement B shall be 3-5mm (0.12-0.2 in) shorter than the measurement A. 6. Adjust respectively, verify the measurement, and secure both couplings with the right torques on the locking screws (see coupling operation & mounting instruction). 7. Mount the elastic gear ring and mount the bell housing/pump on the motor. After mounting it must be possible to move the elastic gear ring 3-5mm (0.12-0.2 in) axial C. The check can be done through the inspection hole of bell housing. Secure motor flange bolts with the right torque - see pump instruction. Caution! Read the pump & coupling Installation, Operation, Maintenance instructions before mounting. Electric motor Motor for use in hazardous areas are marked with regard to the respective permissible conditions of use. Marking: Category 2, Zone 1: Ex d, Ex de, Ex e Category 3, Zone 2: Ex na All rating plate values relating to certification must be carefully checked to ensure that the motor protection, atmosphere and zone are compatible. See special conditions for safe use in electric motor operation manual and ATEX instruction. Caution! Ensure with regular inspection the motor flange is not affected by severe corrosion. Motors in variable speed operation: Certain criteria must be considered to ensure that the combination of VFD and motor can be used safely. The requirements depend on the protection type in use. The motor must be dimensioned so that its surface temperature remains at a safe level with respect to the temperature class. In most cases 4 180R9113 / DKCFN.PI.010.A6.02 / 521B1026 / 02.2013

this requires either combined type tests or the use of direct temperature control. Caution! Consult motor manufacturers for right dimensioning. Cabling and electrical connections Suitable cable lugs must be used for the connection of all main cables. The cable connection must fulfil the requirement stated in the national standards for installation or in the standard EN 60204-1 and EN 60079-14. In addition, earthing or bonding connection facilities on the outside of electrical apparatus must provide effective connection of a conductor. Caution! Read the Installation, Operation, Maintenance manual of the chosen motor to ensure all applicable warranties. Failure modes due to operational conditions Following operational conditions can cause a pump failure: Pump running dry Too high inlet pressure Too low inlet pressure Too high temperature of the fluid being pumped Too high ambient temperature Pump is pumping against blocked port Pump operate with a non-specified/ approved fluid Pump running the wrong direction Non-return valve in front of the pump inlet Insufficient filtration Pump is not being serviced accordance to Danfoss specifications. Danfoss recommends building systems with a high inherent safety degree. The PI&D on the next pages shows how a high degree of safety can be reached when using a Danfoss pump. 2. Design guide for Category 2 (zone 1) systems 2.1 Temperature sensor Pump housing temperature increase causing problems due to pump breakdown/failure in a Category 2 rated system. In a Category 2 system, the pump housing temperature must be monitored. Pump housing temperature must always be lower than 85 C / 185 F. A sensor integrated on the pump must be used to monitor pump housing temperature. This sensor must be mounted on the pump as shown in the drawings. The system must stop the pump, if a temperature of 60 C / 140 F is exceeded. Electronic equipment/control of temperature and pressure measuring must comply with EN 954 (Category 3) or EN 13849-1 to fulfil IPL2. Caution: The sensors may not be exposed by direct cooling as it will affect the thermal readings. Therefore they shall be protected against direct wind. PAHT G 20-90 PAHT G 20-90 S1 Use the M6x10 (A) or M8x10 (B) thread to locate the temperature sensor. Ensure good thermal contact between the sensor and pump end cover and avoid corrosion (material choice of sensor, crevice corrosion). Temperature sensor WIKA TR50-O Explosion protected version with stainless steel contact block can be used (see S1 at picture). Mount the sensor with a M6 screw on the pump end cover. Ensure good thermal contact between the sensor and pump end cover and avoid crevice corrosion. 180R9113 / DKCFN.PI.010.A6.02 / 521B1026 / 02.2013 5

S2 S2 PAH 2-12.5 PAHT G 2-12.5 APP 0.6-3.5 Temperature sensor WIKA TR50-Q Explosion protected version with worm drive hose clip made of stainless steel can be used on these pump types (see S2 at picture). Ensure good thermal contact between the sensor an pump housing and avoid crevice corrosion. Select the right diameter size of the worm drive hose clip. Find the diameter of pump housing in the pump data sheet. S3 Ø4 120 M6 5 42 20 6 APP 5.1-10.2 PAH 20-100 PAH 25-80 Tech 4 Sensor WTH 160-250 Ø6x1.5 Temperature sensor WTH 160-250 Explosion protected version from Heinz Messtechnik can be used on these pump types (see S3 at picture). Mount the sensor in the M6x7 thread hole at pump mounting flange. Ensure good thermal contact and avoid crevice corrosion. 2.2 Pressure sensor Checking whether suction port is fluid filled and fluid flows unrestricted: To monitor if suction line is fluid filled at right pressure, a pressure switch/sensor must be placed in the pump suction port. This switch/ sensor must as a minimum be set to the minimum suction pressure specified in the pump data sheet. Pump must be stopped by system, if pressure declines below sensor pressure setting. 6 180R9113 / DKCFN.PI.010.A6.02 / 521B1026 / 02.2013

2.3 Preferred system design and P&ID for Category 2 pump Pressure and temperature sensors are mounted due to a direct demand originating from ATEX risk evaluation. The pump is directly fed by a pressure line (feed pump). The pump is directly fed by a pressure line (feed pump). Fluid has to be filtrated down to 10µm absolute Pressure switch, Pump is stopped when pressure is below minimum suction pressure according to pump datasheet Category 2 certified electric motor, bell housing and flexible coupling. Pressure feed Temperature swicth set to max 50 C M Temperature sensor mounted on pump. P in P out Danfoss ATEX pumps R out Relief valve To fluid reservoir / drain 180R9113 / DKCFN.PI.010.A6.02 / 521B1026 / 02.2013 7

System where fluid is supplied from tank. Pump is placed outside the tank. Pump suction port is always below fluid level. P in Fluid has to be filtrated down to 10µm absolute Tank Minimum Water Level Switch Maximum Water Temperature Switch set to 50 C Pressure switch, Pump is stopped when pressure is below minimum suction pressure according to pump datasheet Category 2 certified electric motor, bell housing and flexible coupling. M Temperature sensor mounted on pump. P out Danfoss ATEX pumps Relief valve 8 180R9113 / DKCFN.PI.010.A6.02 / 521B1026 / 02.2013

3. Design guide for Category 3 (zone 2) systems 3.1 Pressure sensor Checking whether suction port is fluid filled and fluid flows unrestricted: To monitor if suction line is fluid filled at right pressure, a pressure switch/sensor must be placed in the pump suction port. This switch/ sensor must as a minimum be set to the minimum suction pressure specified in the pump data sheet. Pump must be stopped by system, if pressure declines below sensor pressure setting. 3.2 Preferred system design and P&ID for Category 3 Pressure sensor is mounted due to a direct demand originating from ATEX risk evaluation. The pump is directly fed by a pressure line (feed pump). The pump is directly fed by a pressure line (feed pump). Typical Category 3 systems Fluid has to be filtrated down to 10µm absolute Temperature swicth set to max 50 C Pressure switch, Pump is stopped when pressure is below minimum suction pressure according to pump datasheet Pressure feed M Category 3 certified electric motor, bell housing and flexible coupling. P in P out Danfoss ATEX pumps R out Relief valve To fluid reservoir / drain 180R9113 / DKCFN.PI.010.A6.02 / 521B1026 / 02.2013 9

System where fluid is supplied from tank. Pump is submerged into tank and suction port is always fluid covered. Filter Pressure Switch 10µm filter M Category 3 certified electric motor, bell housing and flexible coupling. R Relief valve Minimum Water Level Switch Maximum Water Temperature Switch set to 50 C P Tank Danfoss ATEX pumps System where fluid is supplied from tank. Pump is placed outside the tank. Pump suction port is always below fluid level. P in Fluid has to be filtrated down to 10µm absolute Tank Minimum Water Level Switch Maximum Water Temperature Switch set to 50 C Pressure switch, Pump is stopped when pressure is below minimum suction pressure according to pump datasheet Category 3 certified electric motor, bell housing and flexible coupling. M P out Danfoss ATEX pumps Relief valve 10 180R9113 / DKCFN.PI.010.A5.02 / 521B1026 / 01.2013

4. EU Declaration of Conformity 180R9113 / DKCFN.PI.010.A6.02 / 521B1026 / 02.2013 11

Danfoss A/S High Pressure Pumps DK-6430 Nordborg Denmark Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 12 180R9113 / DKCFN.PI.010.A5.02 / 521B1026 / 01.2013