Type overview. R B2 en-gb subject to changes 1

Similar documents
DN [ ] DN [ ] Functional data Media Cold and hot water, water with glycol up to max. 50% vol.

Overview of types. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems

PN [ ] D7150NL/BAC D7200WL/BAC D7250WL/BAC D7300WL/BAC [ ]

Characterised Control Valves with Actuators

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Globe Valves. Technical Databook Version 1.2. Belimo Asia Pacific

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Overview of types. Technical data

Technical data sheet. Type overview. Technical data. Safety notes

[ ] Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

k v max 1) [m 3 /h] [mm]

Characterized Control Valves Actuators. Technical Databook Ver. 2

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

2-port ball valves with flanged connection, PN25

Product Table of overview contents and table of contents. Table of contents

TRF.. series spring return rotary actuators for CCV

2-port and 3-port ball valves PN 40

BUD: 3-way flanged valve, PN 6 (pn.)

Butterfly Valves. Technical Databook Version 7.2. Belimo Asia Pacific

Butterfly valves, PN6, PN10, PN16

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Butterfly valves PN6, PN10, PN16

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

VUD: 2-way flanged valve, PN 6 (pn.)

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

BUN: 3-way valve with male thread, PN 16

Overview of types. Technical data. Safety notes

Connection. k VS value m 3 /h

2-Port and 3-Port Zone Valves PN 16

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Power consumption In operation At rest For wire sizing

2-port shutoff valves and 3-port changeover ball valves, PN 40, with internally threaded connection

P. R2...P. Two. have. become. Range of Pressure-Independent Control Valves. one

BQE: 3-way flanged valve, PN 16

Variable Flow Rate Control Unit

BUE: 3-way flanged valve, PN 16/10 (el.)

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

2-port seat valves PN16 with flanged connection

Butterfly valves PN6, PN10, PN16

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing. Non-operating temperature

Open/close ball valves 2-port and changeover ball valves 3-port, PN40

Combi valves PN 16 with flanged connections

3-Port Seat Valves with Male Thread, PN 16

3-Port Seat Valves with Male Thread, PN 16

Connection. k VS -Value m 3 /h

Butterfly valves PN 16

Three-port slipper valves PN10, female-threaded

2-Port Seat Valves with Flange, PN 25

VG6000 Series Forged Brass Valves

76.116/1. BUE: Flanged three-way valves, PN 16/10. Sauter Components

Connection. k VS -Value m 3 /h

2-Port Seat Valves with Flange, PN 25

VBF21.. Three-port slipper valves PN6. Series 02: DN40 and DN50 Series 01: DN

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

VE-S_15-32 Pressure Independent Balancing & Control Valves

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor

3-Port Seat Valves with Flange, PN 6

3-port valves vxf42..

3-Port Seat Valves with Flange, PN 10

3-port seat valves, external thread, PN16

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

2-Port and 3-Port Zone Valves PN 16

Characterised Control Valves with Actuators

Butterfly valves PN 16

Two-port seat valves with male thread, PN16

3-port seat valves PN16 with flanged connection

2-port and 3-port terminal unit valves PN16

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

3-port seat valves PN16 with flanged connection

Power consumption In operation At rest For wire sizing

2-port seat valves PN25 with flanged connection

2-port and 3-port valves with T-bypass PN 16

DESCRIPTION 9.4 G 3/4"M

ZTV/ZTR. Externally threaded 2- and 3-way zone valves. Function. No leakage in closed position

Combi valves, PN 25. for rooms, zones, ventilation and air-conditioning systems

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

2- and 3-port valves with flanged connections, PN 16

3-port seat valves PN6 with flanged connection

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

See «Overview of types»

3-port seat valves PN40 with flanged connection

Air Operated 3 Way Brass Ball Valve

VPI45..Q with pressure test points. Combi valves, PN 25

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

Power consumption In operation At rest For wire sizing. Non-operating temperature

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX

2- and 3-port valves with flanged connections, PN 6

Economy Air Operated Brass Ball Valve

These installation and maintenance instructions must be read in full and completely understood before the installation!

Fan-coil valves Series

2- and 3-port valves with flanged connections, PN 16

Characterized Port -CP Three-Way Ball Valves

2-position electric actuators with Ball valves VBZ ½...11/4

3-port seat valves PN10 with flanged connection

ZONE CONTROLE / 2-WAY

Transcription:

Technical data sheet R30..-..-..-B2 Characterised control valve, 6-way, Internal thread Two sequences (cooling/heating) with one 90 rotary actuator Switching or modulating control on the water side of thermal heating/ cooling elements For closed cold and warm water systems overview kvs (Sequence I) kvs (Sequence II) R3015-P25-P25-B2 15 1/2 0.25 0.25 16 R3015-P25-P4-B2 15 1/2 0.25 0.4 16 R3015-P25-P63-B2 15 1/2 0.25 0.63 16 R3015-P25-1-B2 15 1/2 0.25 1 16 R3015-P25-1P3-B2 15 1/2 0.25 1.3 16 R3015-P25-1P8-B2 15 1/2 0.25 1.8 16 R3015-P4-P25-B2 15 1/2 0.4 0.25 16 R3015-P4-P4-B2 15 1/2 0.4 0.4 16 R3015-P4-P63-B2 15 1/2 0.4 0.63 16 R3015-P4-1-B2 15 1/2 0.4 1 16 R3015-P4-1P3-B2 15 1/2 0.4 1.3 16 R3015-P4-1P8-B2 15 1/2 0.4 1.8 16 R3015-P63-P25-B2 15 1/2 0.63 0.25 16 R3015-P63-P4-B2 15 1/2 0.63 0.4 16 R3015-P63-P63-B2 15 1/2 0.63 0.63 16 R3015-P63-1-B2 15 1/2 0.63 1 16 R3015-P63-1P3-B2 15 1/2 0.63 1.3 16 R3015-P63-1P8-B2 15 1/2 0.63 1.8 16 R3015-1-P25-B2 15 1/2 1 0.25 16 R3015-1-P4-B2 15 1/2 1 0.4 16 R3015-1-P63-B2 15 1/2 1 0.63 16 R3015-1-1-B2 15 1/2 1 1 16 R3015-1-1P3-B2 15 1/2 1 1.3 16 R3015-1-1P8-B2 15 1/2 1 1.8 16 R3015-1P3-P25-B2 15 1/2 1.3 0.25 16 R3015-1P3-P4-B2 15 1/2 1.3 0.4 16 R3015-1P3-P63-B2 15 1/2 1.3 0.63 16 R3015-1P3-1-B2 15 1/2 1.3 1 16 R3015-1P3-1P3-B2 15 1/2 1.3 1.3 16 R3015-1P3-1P8-B2 15 1/2 1.3 1.8 16 R3015-1P8-P25-B2 15 1/2 1.8 0.25 16 R3015-1P8-P4-B2 15 1/2 1.8 0.4 16 R3015-1P8-P63-B2 15 1/2 1.8 0.63 16 R3015-1P8-1-B2 15 1/2 1.8 1 16 R3015-1P8-1P3-B2 15 1/2 1.8 1.3 16 R3015-1P8-1P8-B2 15 1/2 1.8 1.8 16 PN www.belimo.eu R30..-..-..-B2 en-gb 2017-02-01 subject to changes 1

overview kvs (Sequence I) kvs (Sequence II) R3020-P63-1P6-B2 20 3/4 0.63 1.6 16 R3020-P63-2P5-B2 20 3/4 0.63 2.5 16 R3020-P63-4-B2 20 3/4 0.63 4 16 R3020-1-1P6-B2 20 3/4 1 1.6 16 R3020-1-2P5-B2 20 3/4 1 2.5 16 R3020-1-4-B2 20 3/4 1 4 16 R3020-1P6-P63-B2 20 3/4 1.6 0.63 16 R3020-1P6-1-B2 20 3/4 1.6 1 16 R3020-1P6-1P6-B2 20 3/4 1.6 1.6 16 R3020-1P6-2P5-B2 20 3/4 1.6 2.5 16 R3020-1P6-4-B2 20 3/4 1.6 4 16 R3020-2P5-P63-B2 20 3/4 2.5 0.63 16 R3020-2P5-1-B2 20 3/4 2.5 1 16 R3020-2P5-1P6-B2 20 3/4 2.5 1.6 16 R3020-2P5-2P5-B2 20 3/4 2.5 2.5 16 R3020-2P5-4-B2 20 3/4 2.5 4 16 R3020-4-P63-B2 20 3/4 4 0.63 16 R3020-4-1-B2 20 3/4 4 1 16 R3020-4-1P6-B2 20 3/4 4 1.6 16 R3020-4-2P5-B2 20 3/4 4 2.5 16 R3020-4-4-B2 20 3/4 4 4 16 PN Technical data Functional data Media Cold and warm water, water with glycol up to max. 50% vol. Medium temperature 6...80 C Permissible pressure ps 1600 kpa Differential pressure pmax 100 kpa Differential pressure note low-noise operation pv100 < 50kPa Flow characteristic Linear Leakage rate Leakage rate A, air-bubble-tight (EN 12266-1) Pipe connector Internal thread according to ISO 7-1 Angle of rotation 90 Angle of rotation note Sequence 1: 0...30 (Cooling recommended) Dead zone: 30...60 Sequence 2: 60...90 (Heating recommended) Installation position Upright to horizontal (in relation to the stem) Maintenance Maintenance-free Materials Housing Brass body nickel-plated Closing element chrome-plated brass Stem Nickel-plated brass Stem seal O-ring EPDM Ball seat PTFE, O-ring EPDM Flow rate diaphragms rostfreier Stahl Safety notes! The valve has been designed for use in stationary heating, ventilation and airconditioning systems and must not be used outside the specified field of application, especially in aircraft or in any other airborne means of transport. Only authorised specialists may carry out installation. All applicable legal or institutional installation regulations must be complied during installation. The valve does not contain any parts that can be replaced or repaired by the user. The valve may not be disposed of as household refuse. All locally valid regulations and requirements must be observed. When determining the flow rate characteristic of controlled devices, the recognised directives must be observed. 2 R30..-..-..-B2 en-gb 2017-02-01 subject to changes www.belimo.eu

Product features Mode of operation Pressure compensation The 6-way characterised control valve is adjusted by a rotary actuator. The actuator is connected by a modulating control system or a MP-Bus signal and moves the ball of the ball valve to the position dictated by the positioning signal. If the valve is adjusted in the clockwise direction (till the end stop), e.g. the cooling sequence is completely enabled; if the valve is adjusted in the counter-clockwise direction (90 ), e.g. the heating sequence is completely enabled. In cases of combined heating/cooling control elements, the medium remains in the control element when in the closed position (no heating or cooling). The pressure of the enclosed medium can rise or fall due to changes in medium temperature caused by the ambient temperature. The 6-way characterised control valves have an integrated pressure relief function for the purpose of compensating for such pressure changes. The pressure relief function is active in the closed position (45 ) of the valve; reliable separation of Sequences 1 and 2 continues. For additional information, consult the notes for project planning for the 6-way characterised control valve. Accessories Description Mechanical accessories Pipe connector to ball valve 15 1/2 ZR2315 Fastening angle, for 6-way control valves ZR-004 Pipe connector to ball valve 20 3/4 ZR2320 Installation notes Recommended installation positions The ball valve can be installed upright to horizontal. The ball valve may not be installed in a hanging position, i.e. with the stem pointing downwards. 90 90 Water quality requirements Maintenance The water quality requirements specified in VDI 2035 must be adhered to. Belimo valves are regulating devices. For the valves to function correctly in the long term, they must be kept free from particle debris (e.g. welding beads during installation work). The installation of suitable strainer is recommended. Ball valves and rotary actuators are maintenance-free. Before any service work on the final controlling device is carried out, it is essential to isolate the rotary actuator from the power supply (by unplugging the electrical cable if necessary). Any pumps in the part of the piping system concerned must also be switched off and the appropriate slide valves closed (allow all components to cool down first if necessary and allways reduce the system pressure to ambient pressure level). The system must not be returned to service until the ball valve and the rotary actuator have been correctly reassembled in accordance with the instructions and the pipeline has been refilled by professionally trained personnel. www.belimo.eu R30..-..-..-B2 en-gb 2017-02-01 subject to changes 3

Installation notes Flow direction The flow direction must be observed. The position of the ball can be identified from the L-marking on the stem. Heating and cooling in position accuracy I II 100% 100% Valve characteristic curve The lower diagram shows the valve characteristic curve in relation to the ball position. Valve characteristic curve 0 45 90 kv 30 30 0 45 90 α 4 R30..-..-..-B2 en-gb 2017-02-01 subject to changes www.belimo.eu

Dimensions / Weight Dimensional drawings min. Y 42 H H1 H2 min. X 43 L2 L1 32 M4 B1 L 22 12 B The actuator dimensions can be found on the respective actuator data sheet. L L1 L2 R3015-P25-P25-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-P25-P4-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-P25-P63-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-P25-1-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-P25-1P3-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-P25-1P8-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-P4-P25-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-P4-P4-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-P4-P63-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-P4-1-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-P4-1P3-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-P4-1P8-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-P63-P25-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-P63-P4-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-P63-P63-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-P63-1-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-P63-1P3-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-P63-1P8-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-1-P25-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-1-P4-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-1-P63-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-1-1-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-1-1P3-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-1-1P8-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-1P3-P25-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-1P3-P4-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-1P3-P63-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-1P3-1-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-1P3-1P3-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-1P3-1P8-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-1P8-P25-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-1P8-P4-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-1P8-P63-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-1P8-1-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-1P8-1P3-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3015-1P8-1P8-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 B www.belimo.eu R30..-..-..-B2 en-gb 2017-02-01 subject to changes 5 B1 H H1 H2 X Y Weight [ kg]

Dimensions / Weight L L1 L2 R3020-P63-1P6-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-P63-2P5-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-P63-4-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-1-1P6-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-1-2P5-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-1-4-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-1P6-P63-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-1P6-1-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-1P6-1P6-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-1P6-2P5-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-1P6-4-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-2P5-P63-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-2P5-1-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-2P5-1P6-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-2P5-2P5-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-2P5-4-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-4-P63-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-4-1-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-4-1P6-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-4-2P5-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 R3020-4-4-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 B B1 H H1 H2 X Y Weight [ kg] Further documentation Overview Valve-actuator combinations Data sheets for actuators Installation instructions for actuators and/or ball valves Notes for project planning for 6-way characterised control valves 6 R30..-..-..-B2 en-gb 2017-02-01 subject to changes www.belimo.eu