How to bias: V3M, V3MC Rev A 9/23/2011

Similar documents
How to bias: MTS3200, MTS3212 Rev A 8/1/2008 carvinservice.com

How to bias: Vintage 16 Rev C 6/27/2012 carvinservice.com

Biasing the Vintage Series (Nomad, BelAir, VT50, Vintage 33)

Mableaudio Company limited

MARK I. Maintenance and repair information.

Models: EP EP EP EP EP EP USER MANUAL ENGLISH

Experiment 3: Ohm s Law; Electric Power. Don t take circuits apart until the instructor says you don't need to double-check anything.

Crimson 275 Stereo Vacuum Tube Amplifier. Owner s Manual

Notice Regarding this Upgrade. WARNING! Danger Potential

350 Watt Vacuum Tube Amplifier. Owner s Manual

Replacing the Batteries in the Fortress LI 660

MOD 102 GUITAR AMP KIT (K-MOD102)

True RMS Autoranging Multimeter

TECHNICAL SERVICE BULLETIN GO-BASTA TROUBLESHOOTING A DEAD BATTERY

Autoranging Industrial Multimeter

Troubleshooting Guide for Okin Systems

This appendix gives you a general introduction to what electricity is

2003 Cadillac DeVille

Grant Fidelity RITA-880S Tube Amplifier

100 Watt Power Amp 50 Watts x 50 Watts Single Rack Space

Installation Manual Lock-Switch KIA Sorento V3 Installation Manual Lock-Switch V3 for KIA Sorento (02-06) and KIA Sorento (07-09)

HOW IS ELECTRICITY PRODUCED?

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

Autoranging Multimeter

Fitting instructions for the Petrol power amplifier

MOD 102+ GUITAR AMP KIT (K-MOD102+)

troubleshooting guide Robotic Massage Chair

OV4 Installation Manual

Model 2300DL Installation Guide

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

SLIDING DOOR OPERATOR INSTRUCTION MANUAL

Model: OBD-L On-Board-Diagnostics II Memory Saver Detector

GFM-40ac COMPLIANCE WESTUSA. Ground Circuit Tester. Instruction Manual

Replacing the Battery in the Patriot SPS 250, SPS 300 and SPS 450

SAFETY PRECAUTIONS AND WARNINGS...

Troubleshooting Guide for Limoss Systems

CONGRATULATIONS. Dear Friend,

2012 Chevrolet Volt Chevrolet Volt Owner Manual Document ID:

Riverside. Placid Cove Entertainment PIER Assembly Instructions. Pier Left & Right Item # THANK YOU FOR YOUR PURCHASE.

How to Install and Operate the LXA300 Amplifier. Contents. Technical Assistance

MS-1771 User Guide. Caution! Hazardous voltages are present inside amplifier components. Caution! The MS-1771 can produce high sound pressure levels.

Sensors W2 and E2 are optional. Installation guide, 'Pickle Fork' Back-and-Forth Model Train Controller

User s Manual. Automatic Switch-Mode Battery Charger

Amp & Speaker Upgrade Install Instructions for Victory Cross Country

CHAPTER 2. Current and Voltage

INTELLIGENT BATTERY CHARGER/MAINTAINER

Mini Multimeter with Non-Contact Voltage Detector (NCV)

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

MOD 101 GUITAR AMP KIT (K-MOD101)

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

Model 2300JL Installation Guide

OPERATING INSTRUCTIONS

B. Land Rover Range Rover

MODEL 8002SW (1996 MSRP $ )

INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual

DYNACO STEREO 120 C7 REPLACEMENT MANUAL

SECTION 7 3 DO IT YOURSELF MAINTENANCE MR2 U. Electrical components

MICRO P-711 Exerciser Instruction Book

Model: SE-4020-CA Automatic Battery Charger

PET UNIT DOSE CABINET

Controlled Ferroresonant Ballast (CFB) Generation #3. Manual

Electricity. Teacher/Parent Notes.

SFGH-100 SIREN & FLASHING LIGHT SYSTEM Installation & Operation

s4.5mp s4.5 MP System Owner s Manual Architects and custom home builders Everything you need to know.

12V/25A BATTERY CHARGER MAINTAINER / JUMPSTARTER

MODEL 2202 ( MSRP $549.00)

BLUE LIGHT FOR DYNACO STEREO 120 OR PAT-4 ROCKER SWITCHES

How to Convert a Universal Starter Box for Revo 3.3/Platinum

Advanced Troubleshooting Guide Snorkel V Battery Charger Rev 0 3JAN07

HT Dielectric Withstand Tester Volts AC Output Volts DC Output COMPLIANCE WESTUSA. Instruction Manual

GF-30AC. Ground Circuit Tester COMPLIANCE WESTUSA. Instruction Manual

THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER

Using your Digital Multimeter

OPERATING INSTRUCTIONS

Manual Supplement. For IEC V, CAT I & 600, CAT II Meters only. Serial NO and greater.

HIGH VOLTAGE POWER SUPPLY REPLACEMENT

HT-25kVdc Dielectric Withstand Tester Volts DC Output

DIY Synth Kit - Manual

Installation Instructions

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

MASTERsine Inverter PXA Series Installation Guide

Harris IRT Enterprises Digital Resistance Tester Model XP

Ford Super Duty 5.4L Spark Plug Change F250 4x4 XLT Sport Crew Cab

INSTALLATION INSTRUCTIONS

Triple Output Power Supply

PET UNIT DOSE TABLE INSTALLATION MANUAL FN: Rev A 1/18

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

Digital Multimeter: This handheld device is used by this course to measure voltage and resistance we will not use this to measure current or capacitan

Table of Contents Title Page No.

2603 Battery Pal 3 AMP, 1 2 VOLT BATTERY CHARGER

Musical Surroundings Presents:

IMPORTANT SAFETY INSTRUCTIONS

Instruction Manual AMP-1270 AMP-870

DODGE RAM QUAD CAB. Vehicle Specific Subwoofer Enclosure. Made in the USA

Operations and Service Manual. X30208 Load Bank

Hasse Mods for the Ampeg J20 Guitar Amp

innovations in battery charging

Transcription:

How to bias: V3M, V3MC Rev A 9/23/2011 www.carvinservice.com - 1 -

Only a certified technician should bias Carvin amps, this can be very dangerous, you can get hurt, please be very careful when working with any tube amp! If you are changing the tubes make sure they are a matched set. -The bias for the V3M, V3MC should be 80mA (measured across the Standby switch) in the 50W Power Mode setting. These are the tools you will need: 1. A Phillips head screw driver. 2. A small (plastic if available) flat head screwdriver. 3. A multi-meter, with milli amp (ma) reading. 4. Banana to clip meter leads. 5. An Amp Stand or several wood blocks. STEP 1 (A) For the V3M, first remove the top grill with the 4 large side screws. -or- (B) For the V3MC, first remove the amp from the speaker cabinet: 1. Unplug speaker from rear amp jack. 2. Remove rear wood panel (4 screws on back of cabinet) 3. Remove 4 screws on top of amp. 4. Slide amp out of speaker cabinet, to the rear. -Replace tubes now if they are to be changed. *Be very careful with the tubes they can break. STEP 2 Set the amp with tubes down, on an amp stand. NOTE: If you don't have an amp stand, steadily support the chassis on solid blocks of wood so that the power tubes are not touching anything - they get very hot. * Be very careful with the tubes they can break.* STEP 3 Remove the bottom lid by removing the 10 screws where indicated. For the V3MC, there are 6 screws to remove the metal plate. - 2 -

STEP 4 Plug in a speaker to output 1 or 2, they are both the same, both jacks are in parallel. IMPORTANT: Do NOT turn on the amplifier without a speaker plugged in! STEP 5 Next to the Speaker Output you will find the OHM setting. Set the OHM switch to match your speaker. Improper OHM settings will not bias properly, and could result in damage to the amp! STEP 6 Set the Power Mode switch in the back to 50W. NOTE: This step is very important, if you don t set this to 50W setting you will not get the correct bias setting when you adjust it later in the procedure. - 3 -

STEP 7 A) Set the Master volume and all channel Volumes to 0. B) Unplug your guitar cord from the input of the amp. NOTE: If you have signal going through the amp, it will not be the true reading when you set the bias. STEP 8 Plug in AC Cord. *Make sure the rear AC switch is set for the voltage in your area.* NOTE: Sometimes when the AC Cord is new it does not want to go in all the way. Push firmly to force it in, if that is the case. STEP 9 Turn the Power Switch ON. Wait at least 15 seconds, then turn the Standby Switch to RUN (ON). 15secs. > RUN Allow 2 minutes for the amp to warm up. During this time you can set up your Meter to measure the current (ma) DC. CAUTION: The tubes get very hot! Don t touch them, you will burn your skin if you do. IMPORTANT: During biasing and normal amp operation if there is a burning smell or loud crackling noise that comes from the speaker, you should turn off the amp as the amp may have a bad tube. The tubes should never glow RED on the gray plate material, the largest metal part inside the tube. This indicates a major problem and extremely unsafe condition. If this happens turn off the amp immediately! - 4 -

STEP 10 A) Connect the leads to the meter. B) Set your meter to the milliamp (ma) position. Make sure the fuse inside is good. Set meter to DC Current, not AC current. On the meter above, the (ma) and (COM) jacks are used, you have the option to use the (A) jack, but because the setting will be set to 80mA it s best to use (ma). NOTE: If the Fuse inside your meter is open, the meter will not work. It will always read 0mA. STEP 11 * WARNING: The Standby switch is connected to HIGH VOLTAGE! DO NOT touch any metal of the meter lead clips while the meter is connected! 1. 2. Carefully, connect the two meter lead clips, one to each connector of the Standby switch. * Once one lead is connected, BOTH leads will have HIGH VOLTAGE. Make sure the metal of the leads do not touch anything else. It is usually easier to clip the leads to the wires on the Standby switch than connecting to the main circuit board. IMPORTANT: Make sure the Standby switch is set to RUN (ON) before connecting the leads, or you will get a big spark, and may blow the fuse in the Meter. - 5 -

STEP 12 With the meter connected to the Standby switch, turn the switch to Standby (OFF). The meter should now display a reading near 80mA. If you have new tubes, this reading will likely be higher or lower. NOTE: If your meter reads higher that 150mA or goes into overload OL, you should turn off the amp immediately as the amp may have a bad tube. STEP 13 Use a small, flat head screwdriver. * A plastic screwdriver is preferred. Use caution if using a metal screwdriver, to not touch other parts. -If the meter reads over 80mA, lower the bias by turning the bias potentiometer clockwise. -If the reading is under 80mA bring it up by turning the potentiometer counter-clockwise. IMPORTANT: Set your meter to DC Current, your meter should read ma DC. It is OK and normal for the bias reading to fluctuate a little bit and may not be exactly 80mA, but as close as possible. Good Bias Congratulations! Your amp is now properly biased. *PLEASE READ NEXT PAGE FOR SAFE METER REMOVAL and Power off. - 6 -

STEP 14 Power down Steps: 1. Turn the STANDBY switch to RUN. (to protect the Meter) 2. Turn the Power switch OFF. 3. Disconnect the meter clips. (Turn the Standby switch OFF for next time) 4. Unplug the AC cord and wait for the tubes to cool down. 5. Attach the bottom cover with screws. 6. Attach the (V3M) top cover, or (V3MC) speaker cabinet. IMPORTANT: During biasing and normal amp operation if there is a burning smell or loud crackling noise that comes from the speaker, you should turn off the amp as the amp may have a bad tube. The same is true if your meter reads higher that 150mA or goes into overload. The tubes should never glow RED on the gray plate material, the largest metal part inside the tube. This indicates a major problem and extremely unsafe condition. If this happens turn off the amp immediately! CAUTION: The tubes get very hot! Don t touch them, you will burn your skin if you do. If the amp is ON the tubes will get hot, even if you are not playing the amp, wait 30 minutes before handling the unit to ensure the amp cooled down. NOTE: This is not the only way to set the bias on this amp, this is the Carvin Approved method which is used on the Production line in the San Diego, California Factory. NOTE: If you don t see any reading on your meter, check the meter. You may have the leads connected to the wrong jacks on your meter, or the fuse on the meter is open. Comments or questions? You can email us at Carvinservice@carvin.com - 7 -