Transient Fault Location for Branch Circuit Breakers TFT Turquoise Circle Newbury Park, CA Toll Free:

Similar documents
INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

INSP-3 Wiring Inspection Tester

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

User Manual. Solar Charge Controller 3KW

Owner s Manual. Solar Controller GP-PWM-30

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

General Precautions. Personnel Precautions

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Phoenix Inverter

CPS Energy Balancer. Version: 1.0

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

Rental Industry Safety Tester Safe Check 5s

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

Extended Battery Cabinet for Nfinity

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

PowerOhm Installation Manual for LG ATV Series Braking Modules

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

User Manual Solar Charge Controller 3KW

User Manual 1KVA-5KVA INVERTER / CHARGER

User Manual. 3kW Hybrid PV Inverter HX-3000

poollux Power plx-pw60 & plx-pw100

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

PAGE Both power cords must be connected & powered to operate the E-TES SD 120 volt unit.

PF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual

Model (Circuit Tester) Model (GFCI Tester)

Go Power! Manual. GP-SW1500 Inverter. Table of Contents. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4

STONESTAR AUSTRALIA PTY LTD

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Pump Station. Models ADW2W31, ADW2W51, ADW2W71, ADW2W73

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

Autoranging Industrial Multimeter

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

USER'S GUIDE. WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Installation Instructions: Read these instructions in its entirety before performing any installation work.

55185 EMERGENCY PACK FOR LED PANEL TECHNICAL DATA SHEET

Installation Instructions

USER MANUAL. Insulation Tester + DMM. Model MG320

WF-5110R True Sine Wave Inverter

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

1329I Integrated Drive/Motor CE Filter Option Kit

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

Switching DC Power Supply

Product Manual & Installation Guide Vertical Rack Mount 5.0 to 8.6 kw

MODEL 422 Submersible Pump Controller

4KVA/5KVA Parallel Installation Guide

User Manual. Hybrid PV Inverter. Version: 2.1

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

PHASEPERFECT 240V. Digital Phase Converter. Operation & Installation Manual. Single-Phase to Three-Phase Solid State Technology 97% Efficient

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

Foreword

HYBRID 5048E. Hybrid Inverter INSTALLATION AND OPERATION MANUAL. Version 2.0E

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Pure Sine Wave Inverter Charger

True RMS Autoranging Multimeter

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

NIGHT-LITE PRO II. Electrical System Troubleshooting Guide and Procedures

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

Table of Contents 文管中心 發行章

12 VOLT 30 AMP DIGITAL SOLAR CHARGE CONTROLLER

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

AFM500X Automatic Flashing Module

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

SAVE THESE INSTRUCTIONS

1.Safe testing IMPORTANT:

Autoranging Multimeter

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

Mini Multimeter with Non-Contact Voltage Detector (NCV)

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

Power Inverter. Model BI800T and BI800F. w w w.apc.com. Installation Guide and User s Manual

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company

USER MANUAL ONLINE UPS

PAGE Both power cords must be connected & powered to operate the E-TES 120.

w w w.apc.com Home Appliance & Lighting UPS HI800SQ Installation Guide and User s Manual

Troubleshooting Suggestions for Cables and Thermostats

Portable Pack USER MANUAL

These devices meet the requirements of OSHA 29 CFR (b)(1)(ii) and OSHA 29 CFR (a) (2)(ii)(G). Airpax LEL series

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

Electromagnetic Industries LLP

U. Electric Golf Cart (egc) CHARGING PROCEDURE. California Roadster. HUMMER H3 egc. Cadillac Escalade egc

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives VAC and VAC

BRAVO Inverter/Battery Charger. Table of Contents

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Transcription:

TFT100 2450 Turquoise Circle Newbury Park, CA 91320 Toll Free: 800-749-5783

User Manual Introduction Fault Trapper is a new class of tester intended to locate the distance to a circuit anomaly that is either intermittently causing a change in the circuit s characteristics or blowing the circuit breaker. Fault Trapper can capture and save both types of events and saves them separately. If the circuit breaker trips, the backup battery powers the Fault Trapper to allow for an orderly shutdown. The last faults can be viewed using the battery power. The In-Line Adapter isolates the circuit being monitored from the breaker panel and all other breakers. This product should only be used by and connected/disconnected from circuit to be tested by qualified service personnel or certified electricians. Features In line monitoring of branch circuits up to 300 VAC and 40 amps Fault Location reported as distance from Fault Trapper. Simple user interface - Backlit LCD display and three buttons Back-up battery allows capture of breaker trips/unpowered display of results Safety Information Symbol Definition Warning: Potential for personal injury. Caution: Potential for damage to or destruction of equipment. Conformité Européenne. Conforms to European Economic Area directives. Disposal information Safety Alert Symbols To ensure safe operations of the Fault Trapper, follow instructions carefully when using the unit and observe warning and caution messages listed in this manual. Failure to observe warnings can result in severe injury or death and can damage the unit. Fault Trapper is for use only by persons qualified to work in and around breaker panels. Toll Free: 800-749-5783 Page 2 of 8 V 1.4

Do not use the Fault Trapper or cables if they appear damaged or the unit is not working properly. Do not use with voltages and currents higher than the Fault Trapper is rated for - 100 to 240Vac and 40amp branch circuits or less. Turn off circuit breaker prior to attaching Fault Trapper and inline adapter to circuit to be monitored. Do not use around explosive or flammable gas. Safety Information (cont.) Use only test leads provided between Fault Trapper and In-Line adapter. Before opening the battery door, remove cables from Fault Trapper. Always wear personal protective equipment when working with the Fault Trapper Do not open case of either the Fault Trapper of the In-Line Adapter with any cables connected to it Included Equipment: Fault Trapper Main Unit 40amp In-Line Adapter Banana Plug Leader Cable Two Plug-in 2 Wire Terminal Blocks - 8 to 24 AWG (0.2 to 10mm 2 ) Optional Accessories: Spare Plug-in 2 Wire Terminal Blocks Adapters to Standard Plugs/Outlets for inline monitoring Toll Free: 800-749-5783 Page 3 of 8 V 1.4

Fault Trapper Front Panel and Connections: 1 4 2 5 7 8 6 3 Connectors: 1. Power Source - Usually attached to circuit breaker terminal or terminals using plug in terminal blocks supplied. Screws on terminal block should be tightened to 7in-lbs. Connectors (continued): 2. Load - Wire or wires removed from circuit breaker attach here 3. Supplied Leader cable connects 40amp adapter to Fault Trapper. Toll Free: 800-749-5783 Page 4 of 8 V 1.4

Display (4.) - Backlit LCD display shows distance to fault, time to fault, fault type and battery status. Buttons: 5. Display - Used to power unit on briefly to view faults when not powered by AC and to toggle between a breaker trip fault and a non-breaker trip fault, if there is one. 6. Ignore - Press to ignore events that are part of the circuit s normal operation. 7. Test - Press button to start a monitoring. Stops a test if running. 8. Distance Units Hold the Display and Ignore buttons for 3 seconds. The ft or m icons will flash denoting the new unit used for measurement. Caution - Turn off power to circuit the In-Line Adapter is being connected to! Connecting In Line Adapter to Circuit Breakers (USA) 120V Breaker Connection 240V Breaker Connection To connect to a 120Vac Standard Breaker (up to 40amps): All connections to the Fault Trapper 40 Amp adapter are madding using plug in terminal blocks, torque screws to 7in-lbs: 1) Remove the hot wire from the breaker and attach to the load-side of the Fault Trapper 40Amp Adapter, terminal L1. 2) Connect a white jumper wire from the other load-side terminal, L2, to the neutral/ground bus bar. Toll Free: 800-749-5783 Page 5 of 8 V 1.4

3) Connect a jumper wire from the source terminal S2 to the breaker terminal that the wire in step 1 was removed from in step 1. To connect to 220Vac Standard Breaker (up to 40amps): All connections to the Fault Trapper 40 Amp adapter are madding using plug in terminal blocks, torque screws to 7in-lbs: 1) Remove the two hot wires from the breakers and attach to the load side of the Fault Trapper 40Amp Adapter - terminal L1 black wire, terminal L2 red wire. 2) Connect a jumper wire from the source terminal S1 to the breaker terminal that the black wire was removed from in step 1. 3) Connect a jumper wire from the source terminal S2 to the breaker terminal that the red wire was removed from in step 1. 120V AFCI or GFCI Breaker Connection To connect to a 120Vac GFI or AFCI breaker (up to 40amps): All connections to the Fault Trapper 40 Amp adapter are madding using plug in terminal blocks, torque screws to 7in-lbs: 1) Remove the hot and neutral (not the neutral connected to the neutral bus bar) wires from the breaker and attach to the load side of the Fault Trapper 40Amp Adapter - Terminal L1 black wire, terminal L2 white wire. 2) Connect a white jumper wire from the other source terminal, S2, to the neutral contact on the breaker. 3) Connect a black jumper wire from the source terminal S2 to the breaker hot terminal. Instructions for Use -After Connecting in one of the configurations above and switching on the breaker(s). Powering on Unit Once the unit is powered by the AC power connection the battery level will be Toll Free: 800-749-5783 Page 6 of 8 V 1.4

shown on the display. The unit will be ready at this point to run a test. If there is no AC power connection the Display button can be used to power the unit on using battery power to show the results from a previous test. Starting a Test While powered by the AC power connection press the Test button. The Fault Trapper will not run a test under battery power. The velocity of propagation used for distance measurement is 70% the speed of light, a nominal value for power wiring, and is not configurable. Test Running When a test is started boxes running left to right in the test results area and the up down arrows on the left side will be flashing until a fault is shown. Once a fault is found the up down arrows will continue to flash while the test is running while the distance to the last fault found is shown. The lower left portion of the screen denotes the time. Before a fault is found the time will show how long it has been since the test started. Once a fault is found the last fault will be shown and the time will show how long the time was between the beginning of the test and the last fault found. Stopping a Test The three ways a test can stop are when the A/C power goes down, the Test button is pressed and when the Ignore button is pressed. When the A/C power goes down the unit will run on battery power for long enough to finish scanning for the fault which may have caused the A/C to power off (breaker trip). If a fault occurred with the last 30 seconds before the A/C went down it will be classified as the Breaker Trip Fault, the "Voltage!" icon will be displayed when this occurs. A nonbreaker trip fault (if found earlier during the test) will also be saved. When the Test button is pressed during a test any fault found will be saved as a Non-Breaker Trip Fault and testing halted. A second press of the Test button will restart testing and clear any previous faults and Ignores. Ignore Feature - The Ignore button is used to tell the Fault Trapper that a fault it is detecting is part of the normal operation of the circuit such as a motor starting up or a switch being toggled. Pressing the Ignore button will save the location information and fault type and resume monitoring. The ignored fault will be shown on the screen. To clear any saved ignores hold down the ignore button for 3 seconds. Clr will be shown on the screen to indicate the ignore fault was cleared. If the Ignore button is pressed while testing the test will be stopped. If ignore is pressed and there is no fault saved from a previous test dashes will be shown in the test result area to denote that no event is currently ignored. If the ignored fault occurs during the last 30 seconds before the A/C power goes down it will still be shown as the Breaker Trip Fault. The ignored fault is +/- 3% of the distance to the ignored fault location (regardless of being a Short or an Open event). Test Results - The Display button is used to show test results. If the AC power connection is off the unit will use the 9 volt battery to power on the display and show the results from the last test. There can be a Breaker Trip fault and a Non-Breaker Trip fault. The voltage icon will flash indicating that the fault shown caused the breaker to trip. Tap the Display button to cycle between the two faults (if there are more than one). Ft and M units can be toggled by holding down the Display and Ignore buttons for 3 seconds. Battery Remaining In the lower right portion of the screen is a battery icon with bars showing how much remains for the 9V battery. Three bars shows a full battery, two bars is between 33% and 66%, one bar is between 33% and 10%. A flashing battery outline icon shows that there is less than 10% battery life remaining. Since the test runs for a short time after the A/C power shuts off it is recommended to replace the 9V battery (with no A/C power present) once the battery indicator shows one bar or a flashing battery outline icon. Toll Free: 800-749-5783 Page 7 of 8 V 1.4

Warning! - Remove any cables attached to the Fault Trapper before opening battery compartment! Changing Battery 1) Remove screw on rear of unit near the middle with a #1 Philips head screwdriver. 2) Remove battery and disconnect from battery snaps. 3) Attach a new 9 volt alkaline battery to the battery snaps and return to battery compartment. 4) Place battery cover in slot and rotate shut. Fasten shut with screw removed. Do not over tighten! Specifications Physical Dimensions Fault Trapper Main Unit Size: 15.25 x 7.6 x 3.8 cm (6.0 x 3.0 x 1.5 inches) Weight: 255 grams (9 oz.) With battery 40amp In-Line Adapter Size: 11.5 x 7.6 x 5.85 cm (4.5 x 3.0 x 2.3 inches) Weight: 312 grams (11 oz.) Input Rating: Fault Trapper Main Unit: 90 to 265 Volts ac rms 50/60 Hz, 4 watts max. 40amp In-Line Adapter: 300 Volts ac rms, 40 amp circuits maximum, supplies power to main unit Measurement Method: Spread Spectrum Time Domain Reflectometry (SSTDR) Accuracy: +/-10% Maximum Length: 300 ft on NM-B or Wire in Conduit Battery is used to review results when not AC powered Battery Low Level: Approximately 5.5 volts Battery Life (9 Volt alkaline battery, typical) - Standby: 2 years Active: 4 hours typical Environmental Temperature - Operating: 0 to 50 C (32 to 122 F) Storage temperature: -20 to 60 C (-4 to 140 F) Long Term Storage w/ battery: 35 C maximum (95 F) Humidity: 10% to 90%, non-condensing Altitude: 2,000 meters (6,561ft) maximum Toll Free: 800-749-5783 Page 8 of 8 V 1.4