Model Number Structure

Similar documents
Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

Ordering Information. Text PCB Power Relay G5LE

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

Model Number Structure

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Transistor Remote Modules

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

Model Number Structure

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0

Ordering Information. Text Surface-Mounting Signal Relay G6K

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

Model Number Structure

The full feature relay includes the combination for rotary button or plain button or light or indicator flag.

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

AC 250V AC 250V AC 250V AC 250V DC 110V DC 110V DC 110V DC 110V Max. Allowable Current 15A 10A 10A 10A

General Purpose Relay

Model Number Structure

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Model Number Structure

Subminiature Basic Switch

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

General Purpose Relay

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Switching Power Supply

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Type Terminal Coil Contact form Model

Model Number Structure

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Tactile Switch (Hinged Type)

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM

Safety-door Switch. Ordering Information

1 Form A 5A small size power relay for interface

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

General Purpose Relay

Surface mounting, flush mounting, and DIN track mounting

Analog Output Terminal

Analog Input Terminal

Solid State Relays G3NA. Model Number Structure. Model Number Legend

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

Industrial Relay KML(1C, 2C)

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

Model Number Structure

A22NK. Key-type Selector Switches

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

H3DS-X - Solid State Two-Wire Timer

Hinged Safety Door Switch

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

D4DL. Guard Lock Safety-door Switch. Model Number Structure

General Purpose Relay

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Power Contactor with Mirror Contacts

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Power Controller. (see note 1) 10 sec

Small Limit Switch D4V

Inductive Proximity Sensor

Product discontinuation. Notices. Discontinuation Notice of Safety Relay and Socket. G7S series, P7S series. Wire connection

Manual Reset Limit Switch

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

Model Number Structure

Ordering Information. Solid State Relay G3NA. New Models with 75-A and 90-A Output Join the Previous Models with 5- to 50-A Output.

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

2c 15A, 4c 10A polarized power relays

Digital display Pressure range ON/OFF output Linear output Model

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Transcription:

Terminal Relay G6B-4@@ND Compact Terminal Relay with 4 Independent Outputs Equipped with four G6B Mini-relays that are compact, highly sensitive, and highly resistant to dielectric surges, and that can switch 5 amps of power. Sealed plastic construction used for relays. Easy wiring with separated input/output terminals. Special P6B Mounting Socket used to facilitate maintenance (except for high-reliability models). Standard models meet UL508 and CSA requirements. DIN Track mounting, and screw mounting models are available. Model Number Structure Model Number Legend G6B-@@@@ND 1 2 3 Note: UL508 and CSA requirements met by standard models. 1. Number of Poles 4: 4 poles (4PST-NO standard circuit) 47: 4 poles (4PST-NO long-life circuit) 48: 4 poles (4PST-NO high-reliability circuit) Ordering Information 2. Mounting None: DIN Track or screw mounting F: Screw mounting 3. Input Terminal B: Phillips screw (3.5 mm) terminals (4 independent points) B1: Flat-bladed screw terminals (4 points with same common) P: Connector terminals (4 independent points) List of Models Classification Contact form Mounting method Terminals Rated voltage Model Equipped with operation indicator and diode to absorb coil surge 4PST (standard) 4PST (long-life) 4PST (high reliability) DIN Track or screw mounting DIN Track or screw mounting DIN Track or screw mounting Phillips screw terminal Phillips screw terminal Phillips screw terminal 4PST (standard) Screw mounting Flat-bladed screw terminal 4PST (standard) Screw mounting Connector G6B-4BND G6B-47BND G6B-48BND G6B-4FB1ND G6B-4FPND Note: 1. For replacement relays, use relays with the same voltage specifications as the relays provided with the Terminal when it was purchased. Longer operating life can be achieved by replacing the G6B-4@@ND with the G6B-1147P-FD-US. 2. Standard models are also available without relays mounted to the sockets. To obtain such terminals, replace the G6B portion of the model number with P6BF. For example, to order G6B-4BND with empty sockets, use model number P6BF-4BND. Also specify voltage specifications for models with operation indicators. 202 Terminal Relay G6B-4@@ND

Specifications Ratings Coil Ratings (per G6B Relay) Rated voltage Rated current 35.5 ma 19.1 ma 10.7 ma Coil resistance 125 Ω 720 Ω 2,880 Ω Must operate voltage Must release voltage Max. voltage Power consumption Note: 1. Rated current and coil resistance were measured at a coil temperature of 23 C with a tolerance of ±20%. 2. Operating characteristics were measured at a coil temperature of 23 C. 3. The maximum allowable voltage is the maximum value of the allowable voltage range for the relay coil operating power supply. There is no continuous allowance. 4. Diodes to absorb coil surge are equivalent to S5688J (reverse voltage resistance: 600 V; forward current: 1 A). Contact Ratings Note: This value fulfills the P reference value of opening/closing at a rate of 120 times per min (ambient operating environment and determination criteria according to JIS C5442). Characteristics Note: 1. The above values are initial values. 2. Measurement condition: 1 A at 80% max. of rated voltage 10% min. of rated voltage 130% of rated voltage Approx. 200 mw Classification G6B-4BND (standard), G6B-47BND (long-life) G6B-48BND (high-reliability) Load Resistive load (cosφ = 1) Inductive load (cosφ = 0.4, L/R = 7 ms) Resistive load (cosφ = 1) Inductive load (cosφ = 0.4, L/R = 7 ms) Rated load 5 A at 250 VAC, 5 A at 30 VDC 2 A at 250 VAC, 2 A at 30 VDC 2 A at 250 VAC, 2Aat 30 VDC 0.5 A at 250 VAC, 0.5 A at 30 VDC Rated carry current 5 A 2 A Max. switching voltage 380 VAC, 12 Max. switching current 5 A 2 A Max. switching power 1,250 VA, 150 W 500 VA, 60 W 500 VA, 60 W 125 VA, 15 W Error rate (reference value) (see note) 10 ma at 1 ma at 1 VDC Contact resistance (see note 2) Operate time Release time Switching power Insulation resistance Dielectric strength 100 mω max. 10 ms max. (approx. 3 ms) 15 ms max. (approx. 4 ms) Mechanical: 18,000 operations/hr Rated load: 1,800 operations/hr 1,000 MΩ min. (at 500 VDC) 2,000 VAC, 50/60 Hz for 1 min between coil and contacts 2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity 250 VAC, 50/60 Hz for 1 min between coils of different polarity Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Shock resistance Destruction: 1,000 m/s 2 (approx. 100G) Malfunction: 100 m/s 2 (approx. 10G) Endurance Mechanical: 50,000,000 operations min. (at 18,000 operations/hr) Electrical: 100,000 operations min. (at 1,800 operations/hr, rated load) 500,000 operations min. for long-life at 2 A 100,000 operations min for long-life at 5 A Ambient temperature Operating: 25 C to 55 C (with no icing or condensation) Storage: 25 C to 55 C (with no icing or condensation) Ambient humidity Operating: 35% to 85% Weight Approx. 75 g Terminal Relay G6B-4@@ND 203

Engineering Data Maximum Switching Power Switching current (A) AC inductive load (cosφ = 0.4) DC inductive load (L/R = 7 ms) DC resistive load AC resistive load Endurance (x10 3 operations) 4,000 1,000 500 300 100 Endurance G6B-47@ (long life) 250 VAC resistive load 30 VDC resistive load G6B-4@ (standard) 250 VAC resistive load 30 VDC resistive load G6B-4@ (standard) G6B-47@ (long-life) 250 VAC inductive load (cosφ = 0.4) 30 VDC inductive load (L/R = 7 ms) G6B-48@ (high-reliability) 250 VAC resistive load 30 VDC resistive load Contact resistance (mω) Contact Reliability (High-reliability Models) Switching voltage (V) Switching current (A) Number of switching operations ( 10 4 times) 204 Terminal Relay G6B-4@@ND

Dimensions Note: All units are in millimeters unless otherwise indicated. Philip Screw Terminals G6B-4BND G6B-47BND G6B-48BND Note: G6B-4BND is shown in illustration (terminal numbers are incised). 16, M3.5 Phillips head screws Mounting Holes Two, 4 dia. holes or M3.5 screw holes Terminal Arrangement/ Internal Connections (Top View) 78 max. Operation indicator Flat Screw Terminal G6B-4FB1ND 61 max. 43 max. 28 max. (30 max. for G6B-47@@ long-life model) 43 max. Five, M2.6 Operation indicator 24 max. Mounting Holes Two, 4 dia. holes or M3.5 screw holes Note: Do not reverse the coil polarity. Terminal Arrangement/ Internal Connections (Top View) Eight, M3.5 Phillips head screws Connector Terminal G6B-4FPND Note: Do not reverse the coil polarity. 43 max. 24 max. Mounting Holes Terminal Arrangement/ Internal Connections (Top View) 60 max. Operation indicator Two, 4 dia. holes or M3.5 screw holes Eight, M3.5 Phillips head screws Note: Do not reverse the coil polarity. Terminal Relay G6B-4@@ND 205

Accessories (Order Separately) Replacement Relays Applicable terminal relay Rated voltage Model G6B-4BND G6B-1114P-FD-US G6B-47BND Note: Relays cannot be replaced for G6B-48BND, which is mounted directly to boards. Relay Mounting Products G6B-1174P-FD-US Name Relay Removal Tool Short Bars Mounting Track End Plate Spacer P6B-Y1 Relay Removal Tool Model P6B-Y1 G6B-4-SB PFP-100N PFP-50N PFP-100N2 PFP-M PFP-S G6B-4-SB Short Bars Short Bars are used to wire crossovers for common terminals for coils or contacts. G6B-4-C Terminal Covers (Two per set) 206 Terminal Relay G6B-4@@ND

Precautions Wiring Be sure to turn OFF the power when wiring the Unit and do not touch the charged terminals of the Unit. Otherwise, an electric shock may result. Do not apply overvoltage to the input terminals. Otherwise, the Unit may malfunction or burn. Relay Models Do not connect the Unit to loads exceeding the rated switching power (switching voltage or current). Otherwise, faulty insulation, contact weld, or faulty contact of Relays, or damage to Relays may result, or the Relays may malfunction or burn. The life of Relays varies with the switching condition. Test the Relays under the actual operating conditions before using the Relays within the permissible switching frequency. The use of deteriorated Relays may result in the faulty insulation of the Relays or cause the Relays to burn. Do not use the Unit in locations with inflammable gas. Otherwise, a fire or explosion due to the heat of the Relays or sparks from the Relays may result when they are switched. Correct Use Mounting Heat generated by the relays must be conred when gang-mounting. Space must be provided between the relays or other methods must be taken to maintain the relays ambient temperature at 55 C or lower. Replacement of Relays G6B-4@@ND Use the P6B-Y1 Removal Tool as shown in the following diagram. Be sure to turn OFF the power to the Unit before replacing a Relay. Relays must be inserted straight onto the socket connector pins to ensure proper connection. G6B-48BND models (high reliability) are connected directly to boards to increase reliability and the relays are thus not replaceable. If relay replacement is necessary, use the P6BF-4BND Terminal Sockets together with the G6B-1184P Mini Relays. P6BF-4BND Terminal Sockets are equipped with relay replacement sockets. Do not mount Relays that are different to one another in voltage. Relays Mounted G6B-4@@ND standard: G6B-1114P-FD-US G6B-4@@ND long life: G6B-1174P-FD G6B-4@@ND high reliability: G6B-1184P-US Replacement is not possible for G6B-48BND. Wiring Be sure to connect the input terminals with the correct polarity. Coil Voltage Be sure not to impose voltage exceeding the permissible voltage on the coil continuously. Do not use the relays when other inductive loads are connected in parallel with the coil input or when there are surges during power supply because the built-in diodes used to absorb surge may be destroyed. Do Not Use the Following Circuit Handling Inductive load G6B Coil Do not drop, shock, or vibrate the Unit excessively. Otherwise, damage to the Unit may result or the Unit may malfunction. Make sure that all the Relays are properly mounted before use. Screw Tightening Torque Tighten each terminal screw to a torque of 0.78 to 1.18N m. Tighten each mounting screw to a torque of 0.59 to 0.98 N m. Installation Environment Coil surge current absorption diode Do not install the Unit in the following locations. Otherwise, damage to the Unit may result or the Unit may malfunction. Locations with direct sunlight. Locations with an ambient temperature range not within 0 C to 55 C. Locations with rapid temperature changes resulting in condensation or locations with relative humidity ranges not within 10% to 90%. Locations with corrosive or inflammable gas. Locations with excessive dust, salinity, or metal powder. Locations with vibration or shock affecting the Unit. Locations with water, oil, or chemical sprayed on the Unit. Disassembly, Repair, and Modification Do not disassemble, repair, or modify the Unit. Otherwise, an electric shock may result or the Unit may malfunction. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J098-E1-02A In the interest of product improvement, specifications are subject to change without notice. Terminal Relay G6B-4@@ND 207