PSI CASING END SEALS FOR CASING PIPE CLOSURE FOR PROTECTION AGAINST MOISTURE AND DIRT ALSO FOR RETROFITTING INDIVIDUAL CUSTOMIZED SOLUTIONS

Similar documents
PSI RUBBER STEEL FLANGE GASKETS

PSI SEALING PLUGS PRESSURE TIGHT UP TO 3 BAR HORIZONTAL AND VERTICAL MOUNTING POSITION FIVE RUBBER QUALITIES FOR DIFFERENT APPLICATIONS

PSI CASING SPACERS TYPE DSI

PSI HEAT SHRINK PRODUCTS -

PSI FLANGE ISOLATION ACCESSORIES

PSI FLANGE ISOLATION KITS

Table of Contents COOLMANT. 2.0 Table of Contents

PSI Compakt-Seals. Pipeline Accessories. Compakt-Standard Compakt-Special Compakt-Varia. General Information. Selection Guide. Order Submittal Sheet

Table of Contents. EIGERFLEX -Clima. 2.0 Table of Contents

Table of Contents 2.0 COOLFLEX CLX. 2.0 Table of Contents

Pipeline Accessories. Wall Penetration Seals 4 pipes Pressio-Rings Pressio Individual Pressio Universal Pressio 4 cables

Psi casing spacers insulators For PiPE-iN-PiPE systems

DryLin R Linear Plain Bearings, Fast and Quiet

DryLin R Linear Plain Bearings, Fast and Quiet

DryLin R Linear Plain Bearings, Fast and Quiet

DryLin R Linear Plain Bearings, Fast and Quiet

PSI Anti-Corrosion Tape

V-Rings around the clock... around the clock...

PIPE LOG BOOK. Project no:... Project:... Construction section:... On behalf of:... Commissioned by:... Order no:... Date:... Construction period:...

Table of Contents 2.0 EIGERFLEX CPE. 2.0 Table of Contents

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

PRODUCT CATALOGUE DOUBLE PREINSULATED PIPES

Installation instruction do88 performance Intercooler for Volvo S60/V60 T6 MY10-

Manifold Isolation Valves

PFadvantage MF 6850/6855; Ideal 9080/9090

PFadvantage Metalfor Araus 1360

Uponor Infra Fintherm a.s. Pre-insulated pipes and accessories catalogue

Hydraulic Motors. Radial Piston Motors with fixed displacement Series RM...X Vg = 250 cm³/u cm³/u. Repair manual. Doc.-No.

Trelleborg Specialty Mining Hoses

Vibration Control Technology Industry. Catalogue 2012

SCdefault. 900 Monteringsanvisning

Installation instructions, accessories - Rear Seat Entertainment

Installation device. HelaTape. Electrical tapes for sealing, insulation and bundling of cable and conduits.

Heat-Shrinkable Tubing

Installation Devices 4

CS Fiber Optic Splice Case. Instruction

Volkswagen New Beetle Body - Exterior 64 Glass, Window regulators (Page GR-64)

KENNEDY VALVE Plant and Industrial Group 1021 East Water Street Elmira, New York Telephone (607) Fax (607)

RAUVITHERM AND RAUTHERMEX PRE-INSULATED PIPES FOR DISTRICT HEATING PARTS LIST ENERGY EFFICIENCY. Building Solutions Automotive Industry

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

NORMAFIX Retaining Products

DryLin R - Linear Plain Bearings - Fast and Quiet. Linear Bearings. DryLin R. Fax Phone Corrosion resistant

Installation Instructions Supertop for Truck

CALPEX Low Temperature System

INSTALLATION INSTRUCTIONS

PIPE INSULATORS, END SEALS AND INNER-LINKS GLOAZURE CO., LTD

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications.

ANTI VIBRATION MOUNTS

TBM Series 3-Way Ball Valve

SS41HF Mitsubishi Pajero NS & NT V8/V9 Series 3.2 Litre Turbo Diesel (4M41 Engine) 3.8 Litre V6 Petrol (6G76 Engine)

5. STRAUB-FLEX / STRAUB-REP

PIPINGSOLUTIONS, INC.

ROWEKO LOAD-SECURING EQUIPMENT

Installation Manual. For inner sealing sleeves in accessible pipelines, nominal diameters DN inch and Liner End Seal DN 8 inch

PSI Link-Seal Modular Seals

Pipe-Seal-Fix Pipe-Seal-Flex

Heat-Shrinkable Tubing

ITEM PART NO. DESCRIPTION QTY BODY - SNORKEL (SS1410HP) " AIR RAM ASSEMBLY BRACKET - UPPER MOUNTING 1

MATERIAL DATA SHEET* ALPANA d.o.o.

RE / STAR Tolerance Rings STAR Ball Knobs, Knob and Lever Type Handles

h Technical Product Data CC Pressure Pipe Systems

4.0 Table of Contents. CASAFLEX district heating pipe CFL

SS730HF NISSAN D40 NAVARA DUAL CAB/R51 PATHFINDER - 2.5L YD25DDTi ENGINE

Casing Spacers & Insulators For Centering Or Custom Positioning Within Casing

NORTH AMERICAN APPLICATION MANUAL PIPES AND FITTINGS

EVERCONNECT TM. Table of Contents. No-Hub Pipe. Flexible. 7 Couplings. Pipe Caps. Heavy Weight. Test Plugs. Couplings. Shielded Transition

Installation Instructions Supertop for Truck

TM-1620 OPERATING INSTRUCTIONS AND OWNERS MANUAL

INDUSTRIAL VACUUM SYSTEMS MADE AND MANUFACTURED IN GERMANY RANGE OF ACCESSORIES COMPETENCE CENTRE INDUSTRIAL VACUUMING. Valid from

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

Process Inline Filter PLF1

2011 Cadillac CTS Coupe EGX Exhaust Tip & Rear Valance Mesh Accent Kit Part #: Complete E

Elite Skimmer Installation Manual. Manufacturers of Quality Pond Equipment & Supplies Item #PBESIM

Wolf Kunststoff ZEDEX ZX-530 A5D Polymer Alloy

Combi-Seal Flange Isolation Gaskets 4 pipes

CABLE CLAMPS FOR LOW AND HIGH VOLTAGE CABLES

Pipeline Accessories. PSI Pigs. General Information Technical Data Type Selection

ACO Marine product catalogue ACO GM-X and GM-X-VACplus drainage pipes and steel fittings for the marine industry

1. Open front door (20124) and support using Rotunda Flexi-Work Table or equivalent.

Expansion Joint. Ball Joint Flexible Joint

INSTALLATION INSTRUCTIONS

Expansion Joints Guide Module 2a - Axial Expansion Joints General - Standard Program (EFB) - Installation Instructions

PART NUMBER: MINI Cooper S L4-1.6L SEE * NOTE

h Technical Product Data FW Pressure Pipe Systems

PE-HDXc pipes (physically cross-linked polyethylene pipes)

Table of Contents 6.0. PREMANT district heating pipe PRE. 6.0 Table of Contents

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0

GRP backing flanges DIN 2501 Flange connecting dimension PN10 WORK STANDARD. GRP backing flanges made of Polyester resin.

Branch Splice QS-2001B

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

FMCZTINT Mitsubishi Colt CZT front mounting intercooler installation

Table of Contents 6.0. PREMANT district heating pipe PRE. 6.0 Table of Contents

SILENCER ACCESSORIES

WRSS Wraparound Repair Sleeve Installation Instructions

CASING SPACERS DESIGNED FOR WATER, SEWER, OIL & GAS

Positioner Mount Assembly

WET WALL. EvApORATIvE COOLINg SySTEm. 10" x 8" Tee INSTALLATION INSTRUCTIONS

INSTALLATION GUIDELINE -SARAN VAPOR RETARDER FILM AND SARAN VAPOR RETARDER TAPE ITW INSULATION SYSTEMS

11 - Fairings. Fairings. February XLF Page 11-1

Use this NT Supplementary Instruction Sheet along with the standard NT1 Instruction Manual included in the kit.

Transcription:

PSI CASING END SEALS FOR CASING PIPE CLOSURE FOR PROTECTION AGAINST MOISTURE AND DIRT ALSO FOR RETROFITTING INDIVIDUAL CUSTOMIZED SOLUTIONS WWW.PSI-PRODUCTS.COM 111

PSI Casing End Seals Pipes carrying media (e.g. gas pipes, water pipes, sewage pipes, etc.) below motorways, main roads, rail tracks, etc. are often laid in casing pipes. Casing end seals serve to protect the annular space between carrier pipe and casing pipe from moisture, dirt and animals. PSI casing end seals are available for new installations and pipes already installed. Description / Technical Data Type KT casing end seal (only for new installation) Advantages of the PSI type KT casing end seals are, in particular, low storage costs, because of only five different KT sizes suitable for casing pipe sizes from ND 100 to ND 600. Two casing pipe sizes per type are already pre-molded for installation convenience as a collar. The stainless steel straps included in the delivery can be used for all diameters. EPDM approx. 3-4 mm Shore hardness A: 60 ± 5 10-508 mm 110-610 mm Compensation for eccentric Pipe position: yes Fastening strap material: stainless steel Type DU casing end seal (only for new installation) Casing end seals type DU are always supplied in a suitable size for the carrier pipe / casing pipe combination. Further adaptation on the construction site is no longer necessary. EPDM approx. 5-6 mm Shore hardness A: 50 ± 5 20-762 mm 90-965 mm Fastening strap material: stainless steel Type KG/KO casing end seal (KG for for new installation, KO for retrofitting) The type KG/KO casing end seals are manufactured in a conical shape. Due to individual production of the casing seals, they are available for nearly all pipe sizes and carrier pipe/casing pipe combinations. If the opening is a bit too small for the carrier pipe, it can be adjusted on site (see installation instructions). Standard material: Neoprene rubber Material on request: Silicone (only as KG type) and NBR approx. 2-3 mm Shore hardness A: 65 ± 5 32-1320 mm 48.3-2000 mm Special sizes: upon request Fastening strap material: stainless steel 112

PSI Casing End Seals Type HA casing end seal (only for new installation) HA - casing end seals are used when installing new house service lines. EPDM approx. 2-3 mm Shore hardness A: 50 ± 5 25-50 mm 50-90 mm Fastening strap material: stainless steel Type STM casing end seal (only for new installation, split version upon request, installation service available) Seamless STM casing seals are manufactured according to special requirements. They are available for nearly all pipe sizes. This sealing sleeve is the appropriate type especially for extreme eccentricities or if several openings are required, e.g. for additional cable ducts. This sealing sleeve is also available in a reinforced version (type STMV) for higher mechanical loads. Rottolin STM approx. 6-8 mm, STMV approx. 9-11 mm Shore hardness A: approx. 50 ± 5 50-1200 mm 200-1600 mm Compensation for eccentric pipe positioning: yes Special sizes: upon request Fastening strap material: stainless steel More content can be found on www.psi-products.com 113

PSI Casing End Seals Type FW PSI casing end seals type FW are specially developed to provide a pressure-tight seal between carrier and casing pipes. The casing end seal is made of high-quality Rottolin and, thanks to its 9-11 mm thickness, it is particularly dimensionally stable and pressure-tight up to 0.5 bar. As a result of its exceptional flexibility, the casing end seal allows axial and radial movement between casing and carrier pipe. To ensure tightness, the annular space should be no larger than 70 mm. A special, permanently elastic adhesive sealant is sprayed from a cartridge on to the underside of the collar of the sealing sleeve, which is then secured over the casing and carrier pipe with two stainless steel fastening straps. Before backfilling, the casing end seal needs to be covered with foam pads. Technical Data: Rottolin Material thickness: 9-11 mm Color: red Shore hardness: approx. 50 Tensile strength: 11 N/mm 2 Elongation at breaking point: 400% Tear strength: 27 N/mm Max. continuous operating temp. 55 C Sectional view FW-type casing end seal Stainless steel strap Special sealant-adhesive Carrier pipe Stainless steel strap Special adhesive sealant Casing pipe 114

PSI Support Elements for Type STM 3 1 2 1 STM casing end seal 2 Foam segment 3 Plastic holders Fix plastic holders with clip on the inner wall of the casing pipe. Cut to suitable length if necessary. The distance must be chosen according to the recesses of the support segments. Place foam segments on the carrier pipe and insert into casing pipe. Hereby the raised flange rests on the outer front of the casing pipe. This means that secure support is guaranteed. The cable duct has to be pulled through between the semicircular recesses. If the recesses are too small, they can be slightly enlarged by cutting them out further with a knife. Pull casing end seal over the pipe and fit fastening straps (included). 115

Application Recommendation for Casing End Seals APPLICATION RECOMMENDATION Penetration through casing pipes Casing pipe - Carrier pipe 1. 2. 3. With a flush connection to the casing end seal one layer of expansion pads is wrapped around the carrier pipe. (Width of the expansion pad min. 50 cm) By means of adhesive tape, fastening straps, cable ties etc. it has to be fixed proper to the pipe, so that a moving or opening of the expansion pad layer is not possible during the backfilling process. Step 1 needs to be repeated (layer by layer) until the the top layer of the expansion pad is at the same level as the casing pipe circumference. Finally one layer needs to be wrapped and fixed covering the the entire installation. (Overlapping the casing end seal on the casing pipe at least 20 cm). Penetration through the wall PSI Compensating Wall Seal Type VDW 1. 2. With a flush connection to the dynamic end seal one layer of expansion pads is wrapped around the carrier pipe. (Width of the expansion pad min. 50 cm). By means of adhesive tape, fastening straps, cable ties etc. it has to be fixed proper to the pipe, so that a moving or opening of the expansion pad layer is not possible during the backfilling process. Step 1 needs to be repeated (layer by layer) until the the top layer of the expansion pad is flush with the wall -covering the dynamic end seal. 3. Finally one more layer of expansion pads is wrapped and fixed over the entire installation 116

Foam Pads Expansion pads are state-of-the-art in the field of district heating. They are used to reduce the pressure of the soil on the pipe surface of buried pre-insulated pipes in case of thermal expansion. Around elbows the expansion pads are applied to the inner-side (protection for longitudinal reduction and to the outer-side (protection for longitudinal increase) of the elbow. Depending on the manufacturer and type they are usually made of cross-linked or non-cross-linked PE or PUR foams. This means that important material properties such as being rot-proof, low water absorption, excellent mechanical, chemical and physical resistance and contour stability are given. This ensures a long service life and great functionality. As casing end seals for district heating pipes have to deal with pipe movement, space for movement needs to be available around the casing end seal. Expansion pads therefore offer two advantages at the same time: 1. First they provide protection for the casing end seals when backfilling the trench and hold back the pressure while the material compresses 2. They ensure room for movement of up to 25 mm Using expansion pads is generally recommended. Fixing expansion pads Expansion pads Casing pipe Carrier pipe Fastening straps Fixing expansion pads Expansion pads Wall PSI Compensating Wall Seal Type VDW Carrier pipe Fastening strap Loose flange 117

PSI Products GmbH Ulrichstrasse 25 72116 Mössingen / Germany Phone: 0 049 (0)7473 3781 0 Fax: 0 049 (0)7473 3781 35 E-Mail: vertrieb@psi-products.de www.psi-products.de PSI Products GmbH, 04 I 2017