Content 1. Laserline series 3

Similar documents
Volume Extraction Extraction Units

More Powerful. Faster.

Parts Manual PL C 12/28/2010. MP4400 Series (Type 4) Random Orbital Sander. Non-Vacuum Models. Vacuum Models MP 44 XX - XX XX

Parts Manual EN

Product Manual PL31-15LF 04/02/ LF Series Inline Grinders

15D Series Pistol Grip and Inline Drills

10R90 Series Light Duty Precision Turbine Grinder

14TTA-2311 Pistol Grip Clecomatic Clutch Nutrunner

Airetool. Gas Line Cleaners Range: 3/4 (19.05mm) to 1-1/2 (38.10mm) Operating & Service Manual PL EN 10/01/2015

Parts Manual EN PL30-12R04 07/21/ R04 Series 0.1 HP Inline Pencil Grinder

TURBOMOLECULAR PUMPS ATP SERIES

10LF and 12LF Series Right Angle Grinders

35 Series Screwdrivers

Parts Manual PL EN 05/19/ L4321 Router. For additional product information visit our website at

Series Mobile Fume Extraction Filter Systems

15K Series Extented Mini Right Angle Drill Attachment

User Manual. Model: FSL300 Dual Port Laser Fume Extractor

12-10 Series Inline Grinder

Parts Manual EN PL /18/ L41 Series Inline Extended Grinders

10N10 Series Inline Grinder

21L1341 Series Inline Vent Trimmer

75RM-2024 Right Angle Fixtured Nutrunner

HYBRID TURBOMOLECULAR PUMPS ATH SERIES

48EP Series Electronically Controlled Pistol Grip Nutrunner

Airetool. 999-C-45 ( ) Electric Rolling Motor. Operating & Service Manual PL EN 01/26/2012

14PTA & 14TTA Series Pistol Grip Nutrunners

Parts Manual PL

10LF and 12LF Series Right Angle Grinder and Sander

PRODUCT GUIDE. For a better workbench environment!

10N M6 Series Right Angle Grinder

Parts Manual EN

N60 Rotary Vane Pneumatic Motor

MG200 Filter system OPERATING INSTRUCTIONS FOR A BETTER WORKBENCH ENVIRONMENT FILTRONIC

48EP Series Electronically Controlled Pistol Grip Nutrunner

PRODUCT GUIDE Version 2004:02 For a better workbench environment

A6R-2218 Reversible Axial Piston Power Motors

Peck Feed Drills ADVANCED DRILLING EQUIPMENT 3-1 SP EN M

14RA Series Right Angle Nutrunners

STAUFF STAUFF. Local solutions for individual customers worldwide. Medium Pressure Filters SMPF FILTRATION TECHNOLOGY

88 Series Inline and Pistol Grip Screwdrivers

PARTS LIST. d25mhv... UT08067C, UT08084, UT08105 HB25255V... UT08100, UT08121 i25mhv... UT08090 Vac Attack...UT08052C, UT08085, UT08107 P/N PS03956

MA3W-2238 Radial Piston Power Motor

SP-1037EN M. Durable Production Performance. CurrentControl For Quality Critical Joints

21 Series Double Reduction Rotary Vane Power Motors

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

FilterBox Wall. Automatically or manually cleaned for dust & fume applications.

Parts Manual EN

19RA Series Right Angle Nutrunner

MC10. Marine Remote Commander System. Operating Instructions Please read before using this equipment.

Corded Electric Assembly Tools 1 MILLION CYCLES MAINTENANCE-FREE*

Product Data Sheet 4184 N/17X. The engineer's choice

Technical Information Cutting Speeds

SW100PRY220 ( ) Reversible Pistol Grip Swivel Reaction Bar Nutrunner

PKS-FD Servo System

Operating manual UPS - System

200-SERIES EXTRACTION

KNC-PKS-FD S-AAK-DKH

A6R-2221 Reversible Axial Piston Power Motor

FILTER TESTING FOR AIR FILTER AND MEDIA EFFICIENCY MEASUREMENT

Automated Systems. AutomatedSystems. Your Global Automation Solutions Partner.

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

TFS 1000 EXTRACTION / FILTER / POLLUTION CONTROL // TECHNOLOGY

OPERATIONAL INSTRUCTIONS

Quality and Service worldwide. Hydraulic Accessories Flow Indicators

COMPACT DRY PUMPING SYSTEMS DRYTEL SERIES

Fume extractor is warranted for two years, parts and labor.

Excellence in gas analyzers since Over 180 years of JY optical experience. The expertise of Horiba combustion technology

MICROPROCESSOR BASED CONTROLLER

B4R Series Reversible Axial Piston Power Motors

PARTS LIST BLOWERS P/N PS03955

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

Oil Solutions. RIF 300 Return Line Filters. Local solutions for individual customers worldwide FILTRATION TECHNOLOGY

PARTS LIST. Models UT10868 BCS35. i3350b

Harris IRT Enterprises Digital Resistance Tester Model XP

OPERATIONAL INSTRUCTIONS

Operating Instructions. International English. CCS Dust Extractor

DA 35/70 EFI MIL SPEC

Operating instructions

Heating chamber with mechanical convection

The installation and maintenance of this product must be done under the supervision of an experienced

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

MTC Series. Marine Temperature Calibrator

S Series Technical Data...7 How to Order...8 Dimensions...8 Manifold Dimensions and Part Numbers...9

The future of wet and dry vacuum cleaning

D M M. AC Servo Motor DHT Series. Specification Manual Revision 1.4a 01/14. Dynamic Motor Motion Technology Corporation

OPERATING INSTRUCTIONS

FISCHBEIN CONVEYORS FISCHBEIN CONVEYORS

High ingress protection ratings make a difference REO EMC-Filter with IP66

HMM Series Mechanical Heat Meters

series 260 LAS 260 HD FK

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Model TUR-200D Turbine Flowmeter

No.1. Side approach mechanism Precise lateral contacting. Catalogue 1.1. Test Probes Test Fixtures

OPERATION MANUAL TALLY OPEN COLLECTOR UNIT HVS-TALOC. TALLY RELAY UNIT HVS-TALR (1 ST EDITION - Rev. 1) FOR-A COMPANY LIMITED

CONTROL UNITS LOCAL EXTRACTORS LOCAL EXTRACTORS. Pure advantage

MM Series Radial Piston Power Motors

DC Electric Assembly Tools

4.1 Functional diagram FM100 fume hood monitor... 4 Functional description FM Interfaces Terminal diagram FM100...

Heating chamber with mechanical convection

Bench Top Extraction Arms

Transcription:

FT LASERLINE Series TECHNICAL DATA SHEET

FT LASERLINE Series 1. Laserline series Content 1. Laserline series 3 2. Connectors 4 3. Control system 4 4. Options 5 4.1 Automatic flow control 5 4.2 FT communication system 5 4.3 Remote control 5 LASERLINE 450 LASERLINE 250 LASERLINE 150 5. Installation example 5 Laserline series is a wide range of filter systems designed to eliminate hazardous gases and particles from applications like marking, cutting, engraving, welding and barcoding. Laserline 250 and Laserline 450 can be equipped with special filters depending on application. 6. Communication protocol 6 7. External equipment 7 7.1 Pressure drop switch 7 7.2 Sensor for pressure of air blowing out 7 7.3 Temperature sensor 7 7.4 Humidity sensor 7 7.5 Spark & fire protection 7 High effective 3-stage filter Very low sound level Low cost of ownership Interface for fully integrated control Minimal need of service Filter service indicator Technical data LL 150 LL 250 LL 450 Max suction capacity, m3/h (CMF) 100 (58,8) 250 (147) 400 (235) Blower capacity, m3/h (CMF) 140 (82,3) 310 (182) 645 (380) Sound level, db(a) at 1 m < 44 < 50 < 50 HEPA class micro filter, separation degree MPPS, % > 99,98 > 99,98 > 99,98 Gas filter - chemisorbtion - separation degree, % > 99,98 > 99,98 > 99,98 Pre filter bag quality F8 F8 F8 Power, W 100 300 300 Voltage, V 115/240 115 or 230 115 or 230 Height, mm (in) 680 (26,4) 1016 (40) 1016 (40) Width, mm (in) 340 (13,4) 400 (15,7) 796 (31,3) Depth, mm (in) 340 (13,4) 402 (15,9) 402 (15,9) Weight, kg (lb) 18 (39,6) 43 (94,8) 68 (150) Warranty, except for filters, years 2 2 2 2

2. Connectors 4. Options The filter systems are equipped with a D-sub connector, size E with 9-connectors (DE-9). The filter systems are equipped with the female part. DE-9 female connector (on the filter system) 5 4 3 2 1 DE-9 male connector (on the cable) 1 2 3 4 5 4.1 Automatic flow control Automatic adjustments of the air speed through the filter. Increases the life time of the filters. Control system that has a pressure sensor in the inlet, before the pre filter. Keeps the airflow constant as long as the inlet pressure (vacuum) is constant. Another pressure sensor is placed between the main filter and the blower. The pressure drop between the two sensors will indicate the amount of dust cought. To high pressure drop Alarm starts, time for filter change 9 8 7 6 Description 1. Available for options 2. DC 24V on LL250/LL450 (DC 36V on LL150) 3. Ground (GND) 4. Available for options 5. Tx (Transmit) 6 7 8 9 6. Rx (Receive) 7. C 8. Pre filter alarm NO (Normally open) 9. Micro filter alarm NO (Normally open) 4.2 FT Communication system Interface for communication to the filter system via interface RS232. The communication system is an easy tool to use for controlling the filter system and it gives an overview of the filter systems functions. The system is very easy to use, just install the software and then the filter system is controllable. 4.3 Remote control Remote control for easier controlling of the filter system. 3. Control system 5. Installation example Laserline interface is capable of the following: Speed settings with 5 % increments from 0-100 % The air is sucked through a nozzle inside the laser, an pressure drop switch (A) is attached to monitor. The pressure difference between nozzle and ambient air, as this gives a good measurement of the airflow. Ambient air measured inside the laser box gives a more correct value, but the difference should be small when compared to ambient air outside the box. Start/stop function External power devices Safe extraction The laser can control the fume extractor when the Rx (6) to GND (3) circuit is open and stop fume extractor after 3 sec when this circuit is closed. The connector can support external devices with power (2).(36VDC for LL150 and 24VDC for LL250 and LL450). The interface can send information "Filter system running" to the laser, to start the laser.this to be sure that the filter system is on and functional when the laser starts. For added functionality a pressure drop switch could be connected to the filter system (see chapter 7). Laser Line 450 has been equipped with a pressure drop switch (B) to monitor the pressure difference before and after the pre filter, as high pressure will give a signal to change pre filter. Additionally a pressure drop switch is attached (C) to monitor the pressure difference before and after the main filter, as high pressure will give a signal to change main filter. The A, B & C sensors can be adjusted between 30 300 Pascal. One cable is connected to COM (Common) and the other cable is connected to NO (Normally open) to give a signal to the laser. When the pressure difference increases the connection COM & NC will change to COM & NO. - Filter service indication - Pre filter and Hepa system A lowest airflow could be set and send an audible alarm signal through the protocol. - Gas filter Monitoring the gas filter is achieved by measuring the gas filters operating time. We also add the Start/Stop interface, so the laser can open the connection between pin 3 & 6 to start the Laser Line 150/250/450 unit. The laser can then wait until "Airflow OK" sensor is closed, before starting to use the laser. The laser can continue to work as long as "Airflow OK". The sensors for "Pre-filter OK" and "Main filter OK" are only a signal to prepare maintenance. Wiring of interface between the laser and the Laser Line 150/250/450 unit. - P 2 3 1 NO NC COM 4

6. Communication protocol 7. External eqipment Serial communication 1 and 0 sent at a rate of 1200 baud (symbols per second). The remote control or other external unit will send 3 bytes of information in the Rx-cable, when the button is pressed or information need to be sent. At the start of each second the filter system will send 17 bytes of information in thetx-cable and then pause until the start of next second. Each byte is based on 8 bytes (1 or 0) and it is equal to 2 hexadecimal symbols (2 x 4 bits). For special demands or applications a number of external sensors can be used. 7.1 Pressure drop switch A pressure drop switch measures pressure difference. Hexadecimals Hexadecimals (Hex) uses symbols 0-9 for values zero to nine, and A, B, C, D, E, F for values ten to fifteen. The lowest value of a byte is thus 00 and the highest value is FF. In normal "10 base" this represents 0 and 255. Two bytes combined can thus represent 256 x 256 = 65 536 numbers between 0-65 536. Connect the two plastic tubes on the left side to points where you like to measure. When differential pressure increases, the contact 1-3 will open and contact 1-2 will close. Information received (Rx) from external unit to filter system BYTE NAME NOTE EXAMPLE PROTOCOL EXAMPLE VALUE No.1 Start transmission FE Always FE No.2 Button (TG 1 to 4*) TG1=1, TG2=2, TG3=4, TG4=8 05 TG1+TG3 Active No.3 Check sum = Data Byte No.2 05 Same as above * TG1 = Increase, TG2 = Decrease, TG3 = Filter monitoring, TG4 = Start/stop 7.2 Sensor for pressure of air blowing out An electromechanical differential vacuum switch can be used to measure the pressure difference between surrounding air and the pressurized air blowing out. Calibrate this switch to give a signal when the pressure (airflow) is correct. Use pin 1 & 4 in the connector for this circuit or one of these pins and the ground GND to send this signal to the laser. P 2 3 1 NO NC COM Information transmitted (Tx) from filter system to external unit BYTE NAME NOTE EXAMPLE P. EXAMPLE V. No.1 Start transmission FC Always FC No.2 Remaining filter time (High byte) 03FA = 0+(16x16x3)+(16x15)+10 = 1018 03 1018 hours No.3 Remaining filter time (Low byte) FA No.4 PWM = Power to blower 17 = 16+7 =23 (0-99, 0=off ) 17 23 % No.5 Blower speed (Low byte) 00F2 = 0+0+(16x15)+2 = 242 F2 Speed 242 No.6 Blower speed (High byte) 00 No.7 Alarm (triggered by blower speed) 0=off, 1=alarm on without alarm, 02 Alarm ON 2= alarm No.8 Version software (Low byte) B59A = (16x16x16x11) + (16x16x5) + 9A Version 46490 (16x9) + 10 = 46490 No.9 Version software (High byte) B5 No.10 Total operating time (Low byte) 05D7 = 0+(16x16x5)+(16x13)+7=1495 D7 1495 hours No.11 Total operating time (High byte) 05 No.12 Filter time monitoring (6 x 500 hours) Value = 0-5 02 3 x 500 hours No.13 (Not in use) Value = 0 00 0 No.14 (Not in use) Value = 0 00 0 No.15 (Not in use) Value = 0 00 0 No.16 (Not in use) Value = 0 00 0 No. 17 (Check sum) Only (Low byte) Sum of Byte 2 16 gives 2 byte 78 Check sum number. Only (Low byte) sent 7.3 Temperature sensor Use a temperature sensor in the inlet of the machine to make sure that the air is not too warm. You can use pin 1 & 4 in the connector for this circuit, or use one of these pins and the ground GND to send this signal to the laser. 7.4 Humidity sensor Use a humidity sensor in the inlet of the machine to make sure that the air is not too humid.you can use pin 1 & 4 in the connector for this circuit, or use one of these pins and the ground GND to send this signal to the laser. 7.5 Spark & fire protection Laser fumes with sparks and flammable material can cause a fire. It is therefore important to make the installation as safe as possible. 1. Use standard ventilation pipes (metal) to create a distance to the fume extraction unit. A Laser Line 450 can be connected with up to 20 meter ventilation pipe (diameter 160 mm) and this distance will give the sparks time to cool down. 2. Make sure to clean the ventilation pipes often to make sure that large amounts of flammable material is not inside these pipes. 3. A spark trap can be placed in the beginning of the pipe.this spark trap can be made of metal plates or metal mesh. 4. A fire trap can be created with a valve that closes if the temperature rises in the pipe.this will cut off the air flow and the Laser Line 450 unit will then automatically stop. 6

GERMANY Weller Tools GmbH Carl-Benz-Straße 2, 74354 Besigheim Tel.: +49 (0) 7143 580-0 Fax: +49 (0) 7143 580-108 GREAT BRITAIN Apex Tool UK Limited 4th Floor Pennine House, Washington, Tyne & Wear, NE37 1LY Tel: +44 (0191) 419 7700, Fax: +44 (0191) 417 9421 FRANCE Apex Tool Group S.A.S. 25 Avenue Maurice Chevalier B.P. 46, 77832 Ozoir-la-Ferrière Cedex Tel: +33 (0) 160.18.55.40, Fax: +44 (0) 164 64.40.33.05 ITALY Apex Tool S.r.l. Viale Europa 80, 20090 Cusago (MI) Tel: +39 (02) 9033101 Fax: +39 (02) 90394231 SWITZERLAND Apex Tool Switzerland Sàrl Rue de la Roselière 8, 1400 Yverdon-les-Bains Tel: +41 (024) 426 12 06 Fax: +41 (024) 425 09 77 USA Apex Tool Group, LLC 14600 York Rd. Suite A Sparks, MD 21152 Tel.: +1 (800) 688-8949, Fax: +1 (800) 234-0472 CANADA Apex Tools Canada 164 Innisfil Street, Barrie Ontario Canada L4N 3E7 Tel: +1 (705) 728 5564, Fax: +1 (800) 403 8665 CHINA Apex Tools 18th Floor, Yu An Building, 738 Dongfang Road, Pudong, Shanghai, 200122 China Tel: +57 (21) 5111 8300, Fax: +57 (21) 5111 8446 AUSTRALIA Apex Tools P.O. Box 366, 519 Nurigong Street, Albury, N.S.W. 2640, Australia Tel: +61 (2) 6058-0300, Fax: +61 (2) 6021-7403 www.weller.eu 2012, Apex Tool Group, LLC. T0055xxxxx02/13, 1.0, xx