Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

Similar documents
GMS350C/S EC Series. Features:

GMS200C/S EC Series. Features:

GMS100C/S EC Series. Features:

WPS150/S EP Series. Features:

WPS100/S EP Series. Features:

WPS60/S EP Series. Features:

WPS20/S EP Series. Features:

WPS350/S EP Series. Features:

WPS250/S EP Series. Features:

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

TPD2250H6.3 TECHNICAL DATA

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

DIESEL GENERATOR SET DE220E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

DIESEL GENERATOR SET DE165E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

EC series GMS30CS-AU 50

SIVASA Doosan Series. SD250 Technical Data

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

PGDLS352KW 380/ / / / / / / / /

PGDLS / / / / / / / / /

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

BC DIESEL GENERATORS TECHNICAL DATA DIESEL GENERATING SET 60HZ

EP series WPS800S rpm,3-phase/5-wiring

WPS137S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

PGDLS / / / / / / / / /

EP series WPS100S-AU rpm,3-phase/5-wiring

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

WCS2000 / WCS2000S. Features: WCS Series

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

WPS10S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

PGKT / / / / / / / / / / / /

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

GMS1400C / GMS1400CS. Features: EC Series

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET MPS180S-1E / MPS180-1E

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

EP series WPS150BS-AU rpm,3-phase/5-wiring

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

DIESEL GENERATOR SET. DE22E3 (B Series) Output Ratings. Technical Data

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Generator Set Model - 3 Phase Prime* Standby*

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

APD-ULJ250. Standby Power

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

K26M POWER 240 MONO 230 MONO 220 MONO

KV550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

K17M POWER 240 MONO 230 MONO 220 MONO

APD-NG400. NG Standby Power

KH275. Frequency (Hz) Optional control panel POWER. Voltage

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

J66K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

DIESEL GENERATOR SET. 60 Hz FEATURES

KV500C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION. Soundproof version with CE directive (CN09 option) Type soundproofing

DS100C6S. 2 Years or 2000 Hours Warranty. Power Your Dream! Enclosed structure, Small in size, High safety, Easy installation and operation

J165K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

USP&E Cummins Series Diesel Generator Set

V500UC2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

Model MP150 W W

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

ANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V275C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Model NA 2 L

Rating Definitions and Conditions

GMS100C / GMS100CS. Features: EC Series

Rental Power QSB7 series engine

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

28 KW / 28 KVA POWERED by

KV550C2. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel Optional control panel POWER

DIESEL GENERATOR DATA SHEET

GMS800C/ Features:

Powered by Cummins Model:YN-95C

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Rating Definitions and Conditions

Transcription:

WGP-C30/S CUMMINS Series Rotate speed governor: Mechanical governor Excitation system: Self excited, SHUNT A.V.R model: AS480 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life maintenance free battery Lockable battery isolator switch Powder coated canopy (Only for Soundproofed sets) 50 radiator Oil pump on the engine Steel base frame with fork holes Vibration isolators between the engine/alternator and base frame Dry type air filter Base fuel tank for daily running Drain points for fuel tank Operation Manual / Specifications Dimensions and Weights Output Ratings Model L W H Generating Set Prime Power Standby Power WGP-C30 1850 650 1250 WGP-C30 30/24kW 33/26kW WGP-C30S 2250 1050 1380 WGP-C30S 30/24kW 33/26kW Ratings at 0.8 power factor Notes: *Prime Power Continuous duty operation,under variable load 24/24h-10% over load Ratings and Performance Data **Standby Power Engine Model: Cummins 4B3.9-G1 Standby duty, operation under variable load, without Alternator Brand: Stamford over load; Alternator Model: PI 144G Control System: Auto Genset / AMF Standard Reference Conditions Circuit Breaker Type: 3 Pole MCCB Note: Standard reference conditions 25 C (77 F) Air Frequency & Phase: 50Hz & 3PH Inlet Temp, 100m(328 ft) A.S.L. 30% relative humidity. Engine Speed: RPM 1500 Fuel consumption data at full load with diesel fuel with Fuel Tank Capacity: L specific gravity of 0.85 and conforming to BS2869: 1998, WGP-C30 10 hrs WGP-C30S 10 hrs Fuel Consumption: l/hr (100% Load) - Prime Power -Standby Power 6.7 7.5 www.waltpower.com E-mail: sales@waltpower.com 1/5

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Method: Governing Type: Governing Class: Naturally Water Mechanical Compression Ratio: 16.5:1 Displacement: L 3.9 Moment of Inertia:kg.m² 0.143 Engine Electrical System: ISO 8528 G2 - Voltage / Ground 24/Negative - Battery Charger 40 Amp Weight: kg - Dry 308 - Wet 324 Performance Engine Speed: RPM 1500 Gross Engine Power: kwm - Prime 24 - Standby 26 BMEP: kpa - Prime 492 - Standby 553 Lubrication System Oil Pressure @ Idle Speed kpa 207 @ Rated Speed kpa 345 Maximum Oil Temperature: C 121 Total Oil Capacity: L 11 Oil Type: API CH4/15W-40 Exhaust System Silencer Type Industrial Silencer Quantity: 1 Silencer Noise Reduction Level: 15 20dBA Maximum Allowable Back Pressure: mmhg 76 Exhaust Gas Flow: l/s - Prime - Standby Exhaust Gas Temperature: C - Prime - Standby 67.5 71.1 380 410 Cooling System Cooling System Capacity: L 7.2 Maximum coolant Friction Head External to Engine: kpa Maximum Static Head of Coolant Above Engine Crank Centerline m : Standard Thermostat (Modulating) Range: C Injection System Type: BYC A Stanadyne Recommended Fuel Type: Diesel Fuel No.2-D(ASTMD975) Fuel Consumption: l/hr Prime 110% Load 100% Load 75% Load 50% Load WGP-C30 7.5 6.7 5.2 4.0 WGP-C30S 7.5 6.7 5.2 4.0 (Based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869,Class A2) Air Filter Type: Dry type replaceable Element Intake Air Flow: l/s - Prime 32.8 - Standby 32.9 Max. Air Intake Restriction: mmh2o -With Dirty Filter Element 508 -With Normal Duty and Clean Filter Eleme n254 -With Heavy Duty and Clean Filter Elemen 305 28 14 82-95 Minimum Pressure Cap: kpa 69 Maximum Top Tank Temperature for Standby / prime Power: C 104/100 Designed to operate in ambient conditions up to 50 C (122 F) Contact a representative for power ratings at specific site condi Fuel System Air Systems www.waltpower.com E-mail: sales@waltpower.com 2/5

Alternator Model: PI 144G Alternator Physical Data Manufactured by: Stamford Model: PI 144G No. of Bearings: Single Insulation Class: H Winding Pitch Code: 2/3 Wires: 12 Ingress Protection Rating: IP23 Excitation System: Self excited,shunt AVR Model: AS480 Alternator Operating Data Overspeed: rpm 2250rpm Voltage Regulation: (Steady state) ±1.0% Wave Form NEMA = TIF: <50 Wave Form IEC = THF: <2% Air Flow: m3/s 0.1 Altitude: m 1000 Alternator Performance Data: WGP-C30 WGP-C30S Time constants/400v:ms T d 24 24 T d 5 6 T do 550 550 Ta 7 7 Short Circuit Capacity** % 1/Xd 1/Xd Reactances: Per Unit Xd 1.57 1.57 X'd 0.14 0.4 X"d 0.11 0.11 Voltage Technical Data WGP-C30 Voltage Prime Standby 380/220 27.5 32.3 400/230 27.5 32.3 415/240 27.5 32.3 440/254 26.1 30.6 Voltage Technical Data WGP-C30S Voltage Prime Standby 380/220 27.5 32.3 400/230 27.5 32.3 415/240 27.5 32.3 440/254 26.1 30.6 Control System DSE4620 (Standard ) Large back-lit icon LCD display. 3-phase generator sensing. 3-phase generator and mains (utility) sensing. 600 V ph-ph nominal system compatibility. Generator & load power monitoring (kw, kv A, kv Ar, pf). Generator overload protection (kw). Configurable inputs & outputs. Fuel & crank outputs. Magnetic pick-up speed sensing. Battery voltage monitoring. Configurable event log (50). DSE Configuration Suite PC Software. Engine speed protection, engine hours counter, engine pre-heat, engine run-time scheduler, engine idle control for start/stop. www.waltpower.com E-mail: sales@waltpower.com 3/5

Control System DSE7420 (Option ) Microprocessor control, with high stability and credibility. Mains supply and generator operation monitoring. Indicating operation status and fault conditions. Multiple protections; multiple parameters display such as pressure, temperature. Manual and automatic work mode selectable. Real time clock for time and date display, overall runtime display, 99 log entries Overall power output display. Integral speed/frequency detecting, telling status of start, rated operation, overspeed. Communication with PC via RS485 or RS232 interface, using MODBUS protocol. Engine ECU is available. Common USB cable is usable for parameter configuration. Multi-language is available Optional Engine Alternator Generator Set Water Jacket Preheater PMG excitation Tools with the machine Fuel-water separator Alternator heater Coolant (-30 C) Oil pump Winding Temperature Measuring Oil preheater Anti-damp and anti-corrosion treatmen Battery preheater Anti-condensation heater Hired type Trailer Canopy Fuel System Control System Low fuel level alarm AMF function Automatic fuel feeding system ATS control cabinet Fuel T-valves Double HZ & Volt Dual Wall Integral Fuel Tanks ABB & MCCB Dual Wall Sub-base Fuel Tanks Automatic Fuel Fill Options Fuel level shut down sensor Air Inlet system Lube system Starting /Charging system Air pre-heater Manual sump pump Lubricant oil pre-heater Jacket water heater Maintain free battery The following lists are optional by the needs of customers: 4B series 1000 Hrs Maintaining Lits No. Parts Name Part No. Qty Remark 1 Cartridge, Lub LF3345 5 2 Filter, Fuel FF5052 5 3 Filter, Fuel FS1280 5 4 Gasket, Valve cover C3930906 12 5 Belt, V Ribbed C3288790 5 6 Cleaner, Air 838011499 5 7 Bearing, Main 3802010 1 8 Bearing, connecting rod C3971970 8 9 Nozzle tip P332 4 10 Motor, Starting set 4B 1 ONE SET 11 Gasket, upper 4B 1 12 Thermostat C4930315 1 13 Sensor, oil pressure C3967251 1 14 Sensor, temperature C3967250 1 15 Sensor, speed C3971994 1 16 Bushing A3941476 1 17 Solenoid, fuel pump C4942879 1 18 Set, engine GSKT pump 4B 1 www.waltpower.com E-mail: sales@waltpower.com 4/5

WGP-C30/S CUMMINS Series WALT GLOBAL POWER EQUIPMENT CO.,LTD E-mail: sales@waltpower.com Walt reserves the right to make changes in model, technical specification, color, configuration and accessories without prior notice. Please contact the salesman before ordering. 2015 by WALT, All right reserved www.waltpower.com E-mail: sales@waltpower.com 5/5