SBCB-6, SCCB-12, 28, 52 6 to 52 Circuit Combiner Boxes

Similar documents
Combiner Manual #OMBINER #OMBINER < 2* )NSTALLATION 7(&+12/ i 62/$5

Disconnect Combiner Box Installation Manual

Contactor Combiner Box Installation Manual

Combiner Box Installation Manual

Sunny Boy Accessories SUNNY BOY COMBINER BOX TLUS SBCBTL6

Sunny Central Accessories SUNNY CENTRAL STRING-MONITOR US

Installation Guide. Trace Combiner Box 6

Solar Inverter SUNNY BOY 5000US / 6000US / 7000US

System Monitoring SUNNY SENSORBOX

PV Inverter SUNNY BOY 2000HF-US / 2500HF-US / 3000HF-US

RSDCOM. Installation and Operation Guide. Commercial Rapid Shutdown Combiner. DOCR Published March 2017 Revision C English

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

Model LA 4300 Time Delay OFF Controller

Micro Inverter with Communication Unit SUNNY BOY 240-US SUNNY MULTIGATE-US

Model LA 4100 Time Delay OFF Controller

Patient Care Facility

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Model LA 4400 Time Delay OFF Controller

Patient Care Facility

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

PVI 60KW, PVI 82KW, PVI 95KW

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

GS-IOB-120/240VAC. Input/Output/Bypass Assembly. Installation Instructions. Purpose. Scope. Requirements. Grounding Instructions

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Installation Manual AUTOMATIC BACKUP UNIT

CONTACTS RELAY TESTER 66249

Solar Power Installation Application

MIL-24/2600Q MIL-24/3200DQ

CONTACTS EGR VALVE TESTER 66248

Acme Conduit Entry. String Combiner/Pass-Through. FOR PHOTOVOLTAIC INSTALLATION Installation Manual

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

Solar PV Standard Electrical Plan

Mechanical Spiral Sensor

Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS. User Manual

DCCB. Installation Guide. Sine Wave Plus DC Conduit Box (DCCB)

Micro-Air Corporation Route 526 Allentown, NJ 08501

Central Inverter SUNNY CENTRAL 500U

Installation Manual AXITEC SOLAR MODULES

OWNERS MANUAL JANUARY 2007 ISO

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable

Operations Manual. Zero Speed Switch Sensor Model ZS09P


General Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07

Sunny Island 4248U SOLARTECHNOLOGY. Installation & Operating Instructions. Battery Inverter/Charger for Stand-Alone and Back-up Applications

User s Guide. Includes Mounting, Installation, and Product Registration

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

GENERAL INFORMATION. INSTRUCTIONS FOR 500A Lithium Jump Starter

User Manual. Solar Charge Controller 3KW

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

Installation Manual Model 3800/3810

DC to AC Power Inverters

360 Watt Charge Controller

High Performance Output Sine Wave Filter Installation, Operation, and Maintenance Manual

Copyright 2012 DelSolar Co. Ltd MQWRD installation manual-iec Ver. 1.4

Application Note Three Phase String Inverters NEC 2014 Compliance

Installation Manual. Rev

Installation Manual SMA SPEEDWIRE/WEBCONNECT DATA MODULE

END USER TERMS OF USE

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings

INSTALLATION GUIDE AND USER MANUAL

INSTALLATION GUIDE AND USER MANUAL

Compressor Duty Motor - 1 HP. Model 40132

Installation Manual SMA SPEEDWIRE/WEBCONNECT DATA MODULE

DC to AC Power Inverters

Solar Combiner Solutions

OWNERS MANUAL JANUARY 2007 ISO

Cabling for power, control, and video must be run to the installation site before the mount is installed.

CPS 3Phs String Inverters NEC 2014 Compliance

Microinverters and AC PV modules are becoming. Microinverters and AC PV Modules. Different Beasts. Perspectives on PV.

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

2 GALLON COOLANT PUMP

Wenger Corporation 2011 Printed in USA 08/11 Part #158E006-02

BMRX Series ROTARY LEVEL CONTROL

POWER INVERTER 1,000 WATT / 2,000 WATT PEAK

Digital Auto Multi-Tester

Owner's Manual. GenReady Load Center and Transfer Switch. This manual should remain with the unit. Model Numbers. GenReady Basic Panelboard

INSTALLATION MANUAL.

Electric Vehicle Charging Station

TESTER SET SOCKET & VOLTAGE

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

CP /240-MC4 User Manual

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016

PY-11 Voltage & Continuity Tester

AquaPure Ei TM Series Replacement Kits

SUNNY TRIPOWER 12000TL-US / 15000TL-US / 20000TL-US / 24000TL-US / 30000TL-US

SUNTURA SOLAR TRACKER

OnBoard Drum Major Podium

Installation Manual. Installation Manual. AXITEC, LLC 160 Greentree Drive, Suite 101 Dover, Delaware

Installation Instructions Model Geobeam

Lighting Control Unit Installation Instructions

3 Phase Power Systems - Designed for Canada

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

Transcription:

Combiner Manual SBCB-6, SCCB-12, 28, 52 6 to 52 Circuit Combiner Boxes User Manual U.S. Version 2.4 DOC-CBUG-01 i

ii Combiner Manual

Combiner Manual Copyright 2012 SMA America, LLC. All rights reserved. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photographic, magnetic or otherwise, without the prior written permission of SMA America, LLC. SMA America makes no representations, express or implied, with respect to this documentation or any of the equipment and/or software it may describe, including (with no limitation) any implied warranties of utility, merchantability, or fitness for any particular purpose. All such warranties are expressly disclaimed. Neither SMA America nor its distributors or dealers shall be liable for any indirect, incidental, or consequential damages under any circumstances. (The exclusion of implied warranties may not apply in all cases under some statutes, and thus the above exclusion may not apply.) Specifications are subject to change without notice. Every attempt has been made to make this document complete, accurate and up-to-date. Readers are cautioned, however, that SMA America reserves the right to make changes without notice and shall not be responsible for any damages, including indirect, incidental or consequential damages, caused by reliance on the material presented, including, but not limited to, omissions, typographical errors, arithmetical errors or listing errors in the content material. Revision History Rev. No. Date By Description 1.0 Nov. 1, 2004 ES / JP Preliminary Release 1.1 Dec. 1, 2004 KS / JP First Release 1.2 Dec. 10, 2004 JP Torque Update 1.3 Feb. 09, 2005 JP Revised Specifications 2.0 Feb, 2006 JP Update 2.1 Jul, 23, 2007 JL Add Drawings for all 4 models 2.2 July 17, 2009 WZ Address Change 2.3 September 9, 2009 WZ Warranty Change 2.4 February 24, 2012 WZ Revised Specifications SMA America, LLC 6020 West Oaks Blvd., Ste 300 Rocklin, California 95765 Tel +1 916 625 0870 Fax +1 916 625 0871 www.sma-america.com iii

Combiner Manual IMPORTANT SAFETY INSTRUCTIONS *SAVE THESE INSTRUCTIONS* This manual contains important instructions for the Combiner Box models SBCB-6-90, SCCB-12-240, SCCB-28-420 and SCCB-52-416 that must be followed during the installation and use of the Combiner Boxes. The Combiner Boxes are designed and tested according to international safety requirements, but as with all electrical and electronic equipment, certain precautions must be observed when installing the Combiner Boxes. To reduce the risk of personal injury and to ensure the safe installation and operation of the Combiner Boxes, you must carefully read and follow all instructions and warnings in this Installation Guide. Safety and Hazard Symbols This symbol is used to call attention to important information that you must have when installing and/or operating the Combiner Boxes. Failure to read and follow instructions marked with this symbol could result in serious injury and/or damage to the equipment. This symbol appears beside instructions and warnings that deal with dangerous voltages that can injure people who come in contact with them. Warnings WARNING: A Warning describes a hazard to equipment or personnel. It calls attention to a procedure or practice, which, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the SMA equipment and/or other equipment connected to the SMA equipment or personal injury. Warnings may also be accompanied by one or more of the safety and hazard symbols described above to indicate the type of hazard described therein. Other Symbols In addition to the safety and hazard symbols described previously, the following symbol is also used in this Installation Guide: This symbol accompanies notes that call attention to supplementary information that you should know to ensure optimal operation of the system. iv

Combiner Manual Warranty All Combiner Boxes sold in the USA have a five-year warranty. For warranty coverage, or if you have questions about the Combiner Box warranty, contact SMA America at the address, telephone number, or Web site listed on page iii (to send E-mail, see the Contact section of the SMA America Web site: www.sma-america.com). WARNING: All electrical installation must be done in accordance with the National Electrical Code ANSI/NFPA 70, local building codes and the requirements of the authority having jurisdiction. WARNING:To prevent electrical shock or injury, all wiring and commissioning procedures must be performed by qualified personnel. WARNING: Before installing or using the Combiner Box, read all of the instructions and warnings on the Combiner Box and in this Installation Guide. WARNING: PV arrays produce electrical energy when exposed to light and thus create an electrical shock hazard. This GROUND symbol marks areas in the Combiner Box for connecting equipment grounds only. v

vi Combiner Manual

Combiner Manual Introduction Introduction SMA America has introduced a new line of PV combiner boxes designed for use with the SMA family of inverters. Combiner Box features include: Listed to UL 1741 for the United States and Canada Simplified input and output wiring Compact, low-cost design Wall-mount NEMA type 3R outdoor steel enclosure (NEMA type 4 available for SCCB-12, SCCB-28). Reliable bus-work for combined high current conductors Unpacking and Inspection All SMA Combiner Boxes are thoroughly checked before they are packaged and shipped. Although they are shipped in sturdy packaging, damage can still occur during shipping and delivery. It is important to carefully inspect the shipping container and contents prior to installation. If you detect any external damage after unpacking, report the damage immediately to your SMA dealer and shipping company that delivered the unit. If it becomes necessary to return the Combiner, use the original packing material. If you need assistance in dealing with a damaged unit, contact SMA America at 916 625 0870. Input Circuit Configurations The SBCB and SCCB Combiner Boxes are commonly available with 6, 12, 28 or 52 PV input circuits. Other sizes in between 6 and 52 circuits may be special ordered. Please allow sufficient lead time when custom ordering. Contact SMA America for details. 1

1 Installation Combiner Manual 1 Installation Refer to Figures 1-1 through 1-4 for enclosure dimensions. Use appropriate hardware for the mounting surface. The weight of the units is shown in the specification list. 8.50 2X 2.75 2X 3.00 2X 0.47 11.00 12.00 10.23 X X 4X.21 X.40 SLOT 6.05 SECTION X-X Figure 1-1 SBCB-6-90 type 3R Dimensions 2

Combiner Manual 1 Installation 16.50 2X 1.75 2X 13.00 2X.47 2X 17.00 X X 16.06 18.00 4X.32 X.50 SLOT 6.10 SECTION X-X Figure 1-2 SCCB-12-240 type 3R Dimensions 3

1 Installation Combiner Manual 2X 0.62 20.32 2X 3.66 2X 13.00 X X 2X 21.25 20.33 22.25 4X.32 X.50 SLOT 20.00 6.10 SECTION X-X Figure 1-3, SCCB-28-420 type 3R Dimensions 4

Combiner Manual 1 Installation 3X 0.47 2X 1.83 2X 13.50 2X 13.50 3X 43.01 42.23 44.01 X X 4X.32 X.50 SLOT 30.66 12.10 SECTION X-X Figure 1-4, SCCB-52-416 type 3R Dimensions 5

2 Wiring Combiner Manual 2 Wiring Input Wiring NOTE: The combiner enclosure is shipped with no entry holes. A knock-out is required for the appropriate conduit size. SMA recommends wire entry be made from the bottom, but there is no restriction, other than local code, for making wire entries from other locations in the enclosure. Refer to Figures 2-1 through 2-4 for the input and output wiring locations of the combiner box. PV ungrounded conductors (positive in a negative ground system, negative in a positive ground system) are wired into the outside fuse holder terminals. PV grounded conductors (negative in a negative ground system, positive in a positive ground system) are wired into the terminal buses located at the top of the combiner box. All PV safety ground conductors are wired into the terminal busses located at the bottom of the combiner box. Output Wiring The SBCB 6 circuit combiner box has a 90A DC fault current rating. The SCCB 12 circuit combiner boxes has a 240A DC fault current rating. The SCCB 28 circuit combiner boxes has a 420A DC fault current rating. The SCCB 52 circuit combiner boxes has a 416A DC fault current rating. When temperature and voltage drop adjustments are considered, the output conductor sizes can become quite large (500 mcm or greater) and difficult to manage. NEC 310.4 allows paralleling of conductors greater than 1/0 to achieve higher ampacities. The SCCB-28, and 52 circuit combiner boxes provide output terminals for paralleling two conductors for the PV positive and negative, as well as the equipment ground conductors. Combiner Box Output Fusing If more than three combiner boxes are needed for one inverter, it may be necessary to fuse the combiner box output conductors. Please contact SMA America for further details. Refer to Figures 2-1 through 2-4 for the terminal locations of the combiner circuits. 6

Combiner Manual 2 Wiring ETL #3061752-1 ED ED ED EQUIPMENT GROUND WARNING: Risk of Fire Replace only with the same type and rating of fuse! Figure 2-1, Combiner Box Wiring, SBCB-6-90 6 PV input fuse holders, 15 Amp maximum fuse size 7

2 Wiring Combiner Manual ETL #306172-1 ED ED ED EQUIPMENT GROUND WARNING: Risk of Fire Replace only with the same type and rating of fuse! Figure 2-2, Combiner Box Wiring, SCCB-12-240 12 PV input fuse holders, 20 Amp maximum fuse size 8

Combiner Manual 2 Wiring ETL #3061752-1 ED ED S ED ED WARNING: Risk of Fire Replace only with the same type and rating of fuse! EQUIPMENT GROUND EQUIPMENT GROUND Figure 2-3, Combiner Box Wiring, SCCB-28-420 28 PV input fuse holders, 15 Amp maximum fuse size 9

2 Wiring Combiner Manual ED ED ED S ED EQUIPMENT GROUND EQUIPMENT GROUND WARNING: Risk of Fire Replace only with the same type and rating of Figure 2-4, Combiner Box Wiring, SCCB-52-416 52 PV input fuse holders, 8 Amp maximum fuse size 10

Combiner Manual 2 Wiring Fuse Sizing In any electrical system, fuses are used to protect wiring and equipment from excessive currents that can cause damage, heating or in extreme cases even fire. If the fuse rating is too small it could open during normal operation. If the fuse rating is too large, it cannot provide the needed protection. In PV systems, the minimum and maximum size of the series fuse is determined by the electrical ratings of the PV module as well as by UL and National Electrical Code (NEC) requirements. Be sure to consult with your PV module manufacturer for appropriate fuse ratings. The minimum size of fuses and wiring are calculated using the Short Circuit Current Rating (Isc) of the PV module. The NEC requires that all fuses and wiring be sized for a minimum of 1.56 times the Isc of the PV module used in the system. The proper size PV string fuse is determined by calculating 1.56 x Isc (of the PV module) and then rounding up to the next standard fuse size. Example: If the Isc of the PV module equals 6.9 Adc, then the fuse size is determined by 1.56 x 6.9 = 10.76. The next standard fuse size would be a 12A, 600Vdc fuse. DC Disconnect Requirements NEC 690.15-18 allows the use of fuse holders as a suitable means of disconnecting PV arrays for servicing. Additional DC disconnects external to the inverter may be required by the local authority having jurisdiction. WARNING: Never open a fuse holder while it is under load. Electrical arcing and damage to the fuse holder will occur if a fuse holder is opened under load. PV String Fuses The SBCB/SCCB is shipped without PV string fuses. SMA America maintains stock of common fuse sizes for the SBCB/SCCB products. The current rating of the fuse is dependent upon the specific PV module used in the PV array. Please contact SMA America to order the appropriate fuses for your project. 11

Specifications Combiner Manual Specifications SBCB-6 (6 Circuit) Number of Inputs 6 Ungrounded Input Wire Size and Grounded Input Wire Size and Output Wire Size Max Input Fuse Rating (Midget) Max Output Current Max Continuous Output Current Number of Output Wires PV Array Configuration Field Wiring Operating Temperature Range Enclosure Type Weight 10 to 6 AWG 14 in-lb. 10 to 6 AWG 35 in-lb. 10 to 1/0 AWG 120 in-lb. 15 A, 600 V DC 90 A DC 72 A DC 1 Positive, 1 Negative SCCB-12 (10, 14, 16 Circuit may be special ordered) Negative or Positive Grounded 75 Deg C minimum -25 to 50 Deg C NEMA type 3R, Steel 11 lbs. (approx.) Dimensions H x W x D (inches) 10 x 8 x 6 Number of Inputs 10 to 16 Ungrounded Input Wire Size and Grounded Input Wire Size and Output Wire Size Max Input Fuse Rating (Midget) Max Output Current 10 to 6 AWG 14 in-lb. 10 to 6 AWG 35 in-lb. 6 AWG to 300 kcmil 350 in-lb. 20 A, 600 V DC 200 to 320 A DC 12

Combiner Manual Specifications Max Continuous Output Current 160 to 256 A DC Number of Output Wires 1 Positive, 1Negative PV Array Configuration Negative or Positive Grounded Field Wiring 75 Deg C minimum Operating Temperature Range -25 to 50 Deg C Enclosure Type NEMA type 3R/4, Steel Weight 48 lbs. (approx.) Dimensions H x W x D (inches) 16 x 16x 6 SCCB-28 (18 to 26 Circuit may be special ordered) Number of Inputs 18 to 28 Ungrounded Input Wire Size and Grounded Input Wire Size and Output Wire Size Max Input Fuse Rating (Midget) Max Output Current Max Continuous Output Current Number of Output Wires PV Array Configuration Field Wiring Operating Temperature Range Enclosure Type Weight 10 to 6 AWG 14 in-lb. 10 to 6 AWG 35 in-lb. 6 AWG to 300 kcmil 350 in-lb. 15 A, 600 V DC 270 to 420 A DC 216 to 336 A DC 2 Positive, 2 Negative Negative or Positive Grounded 75 Deg C minimum -25 to 50 Deg C NEMA type 3R/4, Steel 56 lbs. (approx.) Dimensions H x W x D (inches) 20 x 20 x 8 13

Specifications Combiner Manual SCCB-52 Number of Inputs 52 Ungrounded Input Wire Size and Grounded Input Wire Size and Output Wire Size Max Input Fuse Rating (Midget) Max Output Current Max Continuous Output Current Number of Output Wires PV Array Configuration Field Wiring Operating Temperature Range Enclosure Type Weight 10 to 6 AWG 14 in-lb. 10 to 6 AWG 35 in-lb. 6 AWG to 300 kcmil 350 in-lb. 8 A, 600 V DC 416 A DC 333 A DC 2 Positive, 2 Negative Negative or Positive Grounded 75 Deg C minimum -25 to 50 Deg C NEMA type 3R 70 lbs. (approx.) Dimensions H x W x D (inches) 42 x 30 x 12 14

COMBOX-UUS120824