HWP2/HWP3/HWP4 Hydraulic Submersible Pumps

Similar documents
HWP2/HWP3/HWP4 Hydraulic Submersible Pumps

Rhino HPP18V FLEX Hydraulic Powerpack

Rhino HPP13 Flex Hydraulic Powerpack

Rhino HBR 60 Hydraulic Breaker

Operating Manual. Type: Hydraulic Submersible Pump 3 inch WARNING! PN: H % electric shock proof. explosion proof.

HCS14/16/18 Hydraulic Cut-off Saw. Prior to Operation. We thank you for choosing a HYCON cut-off saw.

HPD Hydraulic Post Driver

HH10/HH10RV Hydraulic Breaker

Hydraulic Breakers HH35. Prior to Operation. From Serial No Revised We thank you for choosing a HYCON breaker.

Addendum to GPD-30 Owner s Manual

HPP13D Hydraulic Powerpack

Operating Manual TYROLIT ( ) A Company within the SWAROVSKI Group

HPP18V MULTI FLEX Hydraulic Powerpack

HPP09E Hydraulic Powerpack

HYDRAULIC POWER PACK

3 SUBMERSIBLE HYDRAPUMP INSTRUCTIONS

Extreme Duty Grapple (Rock, Skeleton, Scrap & Tine) Operation and Maintenance Manual

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Power Float Manifold. Installation and Operations Manual Module 11A

StormPro BA Series Sump Pump

Operator s Manual. Nitro 1000 Nitro 1000X. Nitro 750 Nitro 750X. September REV0

Operator s Manual. Sabre Crop Divider

Hydraulic Bead Breaker Kit

2019-ON RAM 1500 INSTALLATION INSTRUCTIONS

RAM 1500, 2019 CLASSIC & 2010-ON 2500/3500 INSTALLATION INSTRUCTIONS

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

GRAIN GUARD ROCKET 6000/7000/8000/CR 8000 SERIES INSTALLATION MANUAL

DI-SP/TP. Operators Guide SUBMERSIBLE HYDRAULIC PUMPS HDI Inc. PO Box 1671 Gresham OR (FAX)

Fitting Instruction for EZI-GRIP Bike Rack

COMPRESSED AIR LOADER MODEL: AL-1

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

AUTOMATIC SUBMERSIBLE UTILITY PUMP

Prime Attachments & Custom Fab Brush Mower Owners/Operators Manual

Air Curtain. Installation, Operating and Maintenance Instructions

OPERATIONS AND MAINTENANCE

4-Ton Electric Log Splitter

Sawhorse with Chainsaw Holder

StormPro BCV400 Sewage Ejector Pump

Mulcher Operators Manual

Installation, Operating and Maintenance Manual

UNIVERSAL CUSTOMIZABLE MUD FLAP INSTALLATION INSTRUCTIONS

Installation and Operation Manual

Adjustable Steel Welding Table

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

Large Hydraulic Bead Breaker

Universal Bevel Drives Service Manual

JD-2 TOLL FREE UG August /2011

1. Contents 1. CONTENTS INTRODUCTION SAFETY WARNINGS POWER TILT STANDARD OPERATING INSTRUCTIONS... 5.

TPHK Series Immersible Pump

PIVOTING TANDEM CARRIER 558P

SPECIFICATIONS GENERAL SAFETY RULES PERSONAL SAFETY. Save This Manual TOOL USE AND CARE WORK AREA

Installation Precautions. Use Precautions. Specifications

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

OPERATORS MANUAL SAFETY & WARRANTY SECTION

OWNERS MANUAL HF4263

PIAA Multi-Fit 005/1100X Light Bracket Kits

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

TRUCK PRODUCT LINE A DIVISION OF DAKOTA FLUID POWER, INC.

OWNERS MANUAL HF4550 PREACHER CURL. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

Grundfos.bk Page 1 Thursday, June 11, :59 PM GRUNDFOS INSTRUCTIONS. CRN MAGdrive. Installation and operating instructions

GORE TRAILER MANUFACTURING INCORPORATED 305 Gore Trailer Road Whiteville, North Carolina 28472

Installation Instructions

Complete Raised Rail Roof Rack System SR1098 SR1099

GRAIN GUARD ROCKET 6000/7000/8000/CR 8000 SERIES INSTALLATION MANUAL

Table of Contents. Page 2. midlandusa.com. Model PPG100

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

OPERATIONS MANUAL MODEL MT-500

OWNERS MANUAL HF PAIR VERTICAL DUMBBELL RACK. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

OPERATOR S MANUAL HD 2.3/24 P CD HD 2.3/23 P CD

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

OWNERS MANUAL HF

Fifth Wheel Power Hitch Operations Manual

Pressure Washer Hose Reel

HIGH DUMP ROLL-OUT BUCKET

Grapple Kit Install & Grapple Bucket Manual

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

EF SERIES MOTORS OPERATION & PARTS MANUAL

LEXION SINGLE FUNCTION HYDRAULIC VALVE KIT

Female Plug. connecting to Fuel Quantity

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

HALLMARK INDUSTRIES INC

Component Size Weight Capacity

GRAIN GUARD ROCKET 6000/7000/8000/CR 8000 SERIES INSTALLATION MANUAL

Woolich Racing. Bike Harness Installation Instructions Suzuki Harness Type 4a GSX1300R (Hayabusa)

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

Hydro-Park High-end Four Post Parking Lift PROFESSIONAL PARKING SOLUTION PROVIDER!

SLAB SAW SERIES PARTS LIST

Welding Clips. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

Series 2100 Operating Instructions

MK AUGERS POWER SWING KIT ASSEMBLY & OPERATION MANUAL

Tower Dryer. Wiring Diagrams Manual PNEG-554r09

OWNER S GUIDE 8A DURALIFT II 13,200 LB. CAPACITY. Link Mfg. Ltd th St. N.E. Sioux Center, IA USA

HPP06. Hydraulic Powerpack. HYCON A/S Juelstrupparken 11 DK-9530 Støvring Denmark

IMPORTANT SAFETY INFORMATION

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

Installation Instructions / Warranty

SAVE THESE INSTRUCTIONS

Transcription:

HWP2/HWP3/HWP4 Hydraulic Submersible Pumps 2-3 -4 Revised 6/10/2016 Prior to Operation We thank you for choosing a Rhino submersible pump. To ensure smooth operation and long-lasting performance of your pump, we recommend you to study this operating manual carefully and pay special attention to the chapters about Safety and Service Precautions We hope you will be satisfied with your new Rhino submersible pump. Rhino Tool Co. Inc. 620 Andrews Ave. Kewanee, IL 61443 Tel: 309.853.5555 main Tel: 866.707.1808 toll-free Fax: 309.856.5905 info@rhinotool.com www.rhinotool.com Best regards Rhino Tool Co.

Contents Page Safety Precautions... 2 Oil Flow and Pressure... 3 Useful Information regarding the Use of the Pump... 4 Starting Instructions... 5 Technical Data... 6 Dimensions... 7 Connection to Hydraulic Power Sources... 8 Service and Maintenance... 9 Oil Types... 9 Warranty Terms... 10 1

Safety Precautions Read the pump and power source operating manuals prior to use. Check the oil flow to the submersible pump (see technical data). Please also refer to page 4. A too high oil supply can cause the velocity on the pump to be too high and thereby involve a risk of damage. Make sure that the quick-release couplings are properly connected and locked. When disconnecting the couplings during operation, there is a risk of damage to the motor. Make sure that hose couplings and water hose are properly connected and locked. A fine jet of oil at pressure can penetrate the skin. It is therefore important never to use your fingers to check for oil leaks and never to hold your face close to suspected leaks use a piece of cardboard instead. If oil has penetrated the skin, you should get medical treatment immediately. Always use approved hoses. Contact your dealer, if necessary. The operator must pay extra attention and show caution when working in difficult working areas, such as slopes and other dangerous ground. Do not reach too far with the submersible pump, but always maintain a good footing and keep your balance. In excavations there is always a risk of landslides. The operator must always use protective goggles, earplugs, hard hat and shoes when operating the submersible pump. Inspection or cleaning of the submersible pump and change or disconnection of hoses must never be done while the pump is connected to the powerpack. Always connect hoses to the submersible pump before starting the powerpack. Be sure that all couplings are tight. The pump may not be operated if the oil temperature is above 176 F (80 C ). Operation at higher temperatures may result in the pump (the motor) getting warmer than normal and the operator risks getting burnt on it. To avoid all personal injury and damage to material, all repair, maintenance and service work must be carried out by authorized or properly trained persons only. 2

IMPORTANT A submersible pump not in use should always be kept in a safe and dry place. Always use hoses, couplings and spares as such recommend by Rhino. Always mount the hoses correctly, so that the pump runs the right way. If the pump runs the wrong way there is a risk of defects that are not covered by warranty. Repairs may only be carried out by experienced personnel. Make sure that all couplings are cleaned before connection. Always disconnect the hydraulic circuit before connecting or disconnecting the pump. If this is not done, there is a risk of damage to the quick release couplings, the motor, or the hydraulic system due to overheating. Oil Flow and Pressure Your new Rhino submersible pump is designed for a certain oil flow, working pressure and maximum pressure. A too high oil flow and/or a too high pressure results in overload of the pump, meaning that the lifetime of your new Rhino tool will not be as expected, resulting in repair costs. It is important to check that the pump is not supplied with an oil flow beyond its design capacity, that the working pressure is correct and that the maximum allowed pressure is not exceeded. On page 6 you will find the technical data, and on page 8 there is a guide to connecting to hydraulic power sources and how to ensure that the submersible pump is not overloaded. 3

Useful Information regarding the Use of the Pump The Rhino submersible pump is compact and light and offers high performance. The 2 pump weighs only 16.9 lb (7.7 kg) and pumps up to 12,151 gal. per hour (46 m³ per hour), the 3 pump weighs only 24.2 lb (11 kg) and pumps up to 21,137 gal. per hour (80 m³ per hour) and the 4 pump weighs 58.8 lb. (26.7 kg) and pumps up to 54,120 gal. per hour (204 m³ per hour). Only hydraulic submersible pumps have such high performance in relation to size. Rhino submersible pumps are perfect tools for pumping all kinds of fluids especially dirty fluids. The pumps are VORTEX pumps, which are designed specifically to pump dirty fluids, without a need for extra maintenance and without reducing the lifetime of the pump and its components. The 2 pump can pump solids up to 1.5 inches (ø38 mm), the 3 pump solids up to 2.5 inches (ø63 mm) and the 4 pump solids up to 3 inches (ø74 mm) The pump can be used for many purposes and in many connections. In this respect an important feature of the pump is that it will not give any sparking. The construction of the pump allows it to run dry without damage. 4

The pump can also be connected to excavators and other machines. We recommend the use of a Rhino oil flow divider to protect the pump against a too high oil supply, a too high pressure and backwards rotation. Please refer to page 8. For operation in sensitive environments, you should only use bio-degradable oil. Starting Instructions START Attach the discharge hose with the Snap-Tite coupling to the top of the pump Connect hydraulic hoses clean couplings before connection. Get a good footing before you start pumping water. Avoid overly large debris. Lower the pump into the fluid. Make sure that the water hose is fixed. Do not use the discharge hose or hydraulic hoses to raise or lower the pump. Always raise or lower by using the handle on top of the pump. Set the power source to ON. STOP Set the power source to OFF. 5

Technical Data 2 Pump 3 Pump 4 Pump Weight w/o hoses (lbs) 17 (7.7 kg) 24.25 (11 kg) 58.8 (26.7 kg) Oil flow (g.p.m.) 5-8 (20-30 l.p.m.) 5-8 (20-30 l.p.m.) 5-9 (20-34 l.p.m.) Working pressure nominal (PSI) 1305-2030 (90-140 bar) 1740-2030 (120-140 bar) 1740-2175 (120-150 bar) Pressure relief valve in power source (PSI) Max. 2450 (Max. 172 bar) Max. 2450 (Max. 172 bar) Max. 2450 (Max. 172 bar) Max. return pressure (PSI) 580 (40 bar) 580 (40 bar) 580 (40 bar) Max. oil temperature 176 F (80 C) 176 F (80 C) 176 F (80 C) Max. water temperature 176 F (80 C) 176 F (80 C) 176 F (80 C) Max. solid size - inches 1.5 in. (ø38 mm) 2.5 in. (ø63 mm) 3 in. (ø74 mm) Max. pumping capacity 202 gal/min 46 m³/hour 352 gal/min 80 m³/hour 902 gal/min 204 m³/hour Max. head - feet 92 ft. (28 m) 72 ft. (22 m) 46 ft. (14 m) Connection water hose 2 thread internal BSP 3 thread internal BSP 4 thread internal BSP May run dry Yes Yes Yes 6

Dimensions HWP4 BSP 7

Connection to Hydraulic Power Sources The submersible pump can be connected to various hydraulic power sources, such as excavators, trucks, loaders, tractors etc., and of course Rhino powerpacks, the design of which ensures your new Rhino pump the absolute best working conditions. It is important that the submersible pump is not subjected to an oil flow and a working pressure beyond its design capability. Please refer to the ID-tag. Check the oil flow and the working pressure by means of test equipment. The test equipment should comprise a pressure gauge, a flow meter and a valve for adjustment of pressure. Make sure that: the oil supply is not too high the working pressure is not too high the return pressure is not too high the pressure relief valve is not set higher than 2495 psi (172 bar) the internal diameter of the hoses is sufficient (min. ½ ) all couplings are in order the power source is equipped with an oil filter of min. 25 Micron Hoses with too small internal diameter and/or defect couplings cause the pump to work with incorrect working pressure. Your dealer can help you check this. If the output of the power source is too high: the power source must be adjusted to correct output or you can choose to mount a Rhino oil flow divider to protect the pump against overload or you can choose one of our Rhino powerpacks. Your dealer can guide you in choosing the right powerpack. In case of doubt, please contact your dealer or Rhino Tool Company. 8

Service and Maintenance Service/Maintenance Daily Weekly Yearly Check couplings and clean carefully Check hydraulic hoses NOTE: At service/repair it is important that the quick-release couplings are mounted correctly. X X Oil Types The Rhino submersible pump uses standard hydraulic oil, i.e. all types of mineral oil and biodegradable oil, which comply with the following values: Recommended viscosity 20-40 cst Permitted viscosity 15-1000 cst Viscosity index Min. 100 Temperature area -4 to +160 F (-20-70 C) If using biodegradable oil, we recommend the use of oil based on Rapeseed Oil. Other types of oil can be detrimental towards parts of the pump. 9

General Warranty Conditions & Limitations on Liability Rhino Tool Company, Inc. ( Rhino ) warrants to the original purchaser, purchasing the Equipment in new condition, in original packaging from an authorized dealer that its Hydraulic Tool(s) will be free from defects in workmanship and materials (the Limited Warranty ). The Limited Warranty shall survive for twelve (12) months with regard to all other components, excluding the Honda 13 HP engine and Vanguard 18 HP engine for which Rhino provides no warranty and for which the warranty is provided by American Honda Motor Co., Inc and by Briggs and Stratton Corporation respectively and the shall be the sole warranty applicable thereto. This Limited Warranty is non-transferable. In the event of a warranty claim, the Hydraulic Tool(s) must be returned freight prepaid to Rhino or delivered in person to a Registered Rhino Servicing Dealer within the applicable warranty period with proof of original purchase provided. Rhino s obligation under this Limited Warranty is expressly limited to the repair or replacement, at Rhino s election, of such defective Hydraulic Tool(s), which is proved to be defective upon inspection by a Rhino-certified/authorized technician. This Limited Warranty does not extend to a Hydraulic Tool(s) which has been subject to misuse, neglect, or accident, nor does it extend to any Hydraulic Tool(s) which has been repaired, altered, or serviced by unauthorized persons. This Limited Warranty does not cover any damage or adjustments required to any Hydraulic Tool(s) if such damage or adjustment is caused by the use of supplies, parts, or attachments not sold or approved by Rhino. EXCEPT AS OTHERWISE PROVIDED HEREIN, RHINO DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. UNDER NO CIRCUMSTANCES SHALL RHINO BE LIABLE FOR ANY LOSS OF BUSINESS, REVENUES, OR PROFIT OR OTHER INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES OR LOSS ARISING OUT OF ANY DEFECTS IN OR PERFORMANCE OF THE HYDRAULIC TOOL(S), HOWSOEVER CAUSED. 10