Low Amp Probe EETA308A

Similar documents
1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

LEM~flex RR3020 AC Current Probe Operating Instructions Mode d emploi Bedienungshandbuch Manuale Operativo Manual de uso

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

i3000s/i2000 Flex AC Current Probe

i400s Calibration Information Introduction

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

323/324/325 Clamp Meter

AC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL

CP GermanCp 41_CP C. Operating Instructions. CP 30 CP 330 CP 1100 AC/DC current probe /7.10

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

362 Clamp Meter. Users Manual

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

AC/DC CURRENT TRANSDUCER 600A 10mV/1A, 1mV/1A

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Users Manual. Phase Rotation Indicator

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

OPERATION MANUAL MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 LIST OF PRODUCTS

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

365 Detachable Jaw True-rms Clamp Meter

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

302+/303 Clamp Meter. Users Manual

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

4-20mA DC PROCESS CLAMP METER

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

362 Clamp Meter. Users Manual

Table of Contents Title Page No.


Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

Mini Multimeter with Non-Contact Voltage Detector (NCV)

373 Clamp Meter. Users Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Users Manual. MegOhmMeter

ICA 39T INSTRUCTION MANUAL ICA39T AC/DC CURRENT TRANSDUCER

Mini Multimeter with Non-Contact Voltage Detector (NCV)

707Ex. Users Manual. ma Calibrator

DC POWER SUPPLY ALIMENTATION C.C.

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

Barnant Company (Type J) (Type K) (Type T)

Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

Dawson DAN100. Analog Multimeter User s Manual

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

True RMS Autoranging Multimeter

Calibration Manual. Detachable Jaw True-rms Clamp Meter

USER MANUAL. Insulation Tester + DMM. Model MG320

K100 K110 AEMC INSTRUMENTS ENGLISH. User Manual. n DC/AC MICROPROBE. Model K mv/ma OFF. DC/AC MicroProbe

Phase Sequence Tester

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Visit us at

TMULD-300 ULD-300. Ultrasonic Leak Detector. Users Manual. 99 Washington Street Melrose, MA Phone Toll Free

Autoranging Multimeter

Non-Contact Phase Rotation Tester

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

MultiCal. Operation Manual for MultiCal mmhga/psia Pressure Module

ATD-5570 Deluxe Automotive Meter with RPM and Temperature Functions Owner s Manual Features:

Temperature Calibrator

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Autoranging Industrial Multimeter

Model Insulation Tester / Megohmmeter. User Manual

Dawson DDM190D. Digital Multimeter User s Manual

INSTRUCTION MANUAL DM5B Fax: (503)

Go to to register your product and find more information.

Infrared Thermocouple Probe

For technical questions and replacement parts, please call

INSP-3 Wiring Inspection Tester

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

KMP Insulation-Continuity Tester. Users Manual

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Operator s Manual TC-253A. Temperature Converter

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

MICROMANOMETER ALNOR MODEL AXD610 AIRFLOW INSTRUMENTS MODEL PVM610

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

650mA Phase Dimmable LED Driver

716 Pressure Calibrator

Instruction Manual IVT-10 / IVT-20 Voltage Tester

TMA5 Mini Vane Anemometer

Cable Length Meter INSTRUCTION MANUAL

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

User's Guide. True RMS Multim eter. Extech 430

Digital Multimeter User's Manual

Safety design conforming to the following provisions

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Transcription:

Low Amp Probe EETA308A Reference Manual First Edition

SAFETY WARNING DO NOT APPLY OVER 150V AC (RMS) OR DC. DISCONNECT LEADS BEFORE REMOVING THE BATTERY COVER. DO NOT ALLOW THE CABLE TO BECOME ENTANGLED WITH MOVING PARTS. ELECTRICAL SHOCK OR CONTACT WITH MOVING PARTS CAN CAUSE INJURY. DO NOT USE THE PROBE IF ANY PART OF THE PROBE INCLUDING THE LEAD AND CONNECTOR(S) APPEAR TO BE DAMAGED OR IF A MALFUNCTION OF THE INSTRUMENT IS SUSPECTED. Safety Standards BSEN61010-1: 2001-02 BSEN61010-2-032: 1995 BSEN61010-2-031: 1995 150 VRMS, Category I Rated Transient Overvoltage 800V Pollution Degree 2 Use of the probe on uninsulated conductors is limited to 150 VAC RMS or DC and frequencies below 1 khz. Do not use for measurements with installation categories II, III and IV. EMC Standards BSEN 61326 : 1998 FCC Part 15 Class B

SAFETY The following symbols appear on the products: Caution! Refer to Manual Double/Reinforced Insulation Read all instructions completely before using this product. To avoid electric shock: use caution during installation and use of this product. High voltages and currents may be present in circuit under test.

Low Amp Probe EETA308A Reference Manual First Edition October 2001

Technical Assistance No: 1 (888) 249-0498 The information, specifications and illustrations in this manual are based on the latest information available at the time of publication. The manufacturer reserves the right to make equipment changes at any time without notice. 2001 Snap-on Technologies, Inc.

Contents Page 1.0 Introduction...2 2.0 Specifications...3 2.1 Electrical Data...3 2.2 General Data...3 3.0 Operating Instructions...4 3.1 Connecting the Probe...4 3.2 Switch on...4 3.3 Low Amp Current Probe Zero Adjustment...4 3.4 Error Factor...4 3.5 Reading the mv Scale...5 3.6 Current Measurement Applications...5 4.0 Current Probe Characteristics...10 5.0 Battery Replacement...11 6.0 Cleaning...12 7.0 Warranty...13 8.0 Declaration of Conformity...14 1

1. 0 INTRODUCTION The Snap-on Low Amp Current Probe measures AC or DC current with digital multimeters, oscilloscopes, and other suitable recording instruments. The probe provides accurate and reliable non-intrusive testing of ignition coils, injectors, fuel pumps, relays, electric motors, and parasitic draw. The jaws of the probe are designed with a built in hook feature to help isolate wires (refer to Figure 1). Using advanced Hall Effect technology, the Snap-on Low Amp Probe accurately measures currents from 10 ma to 40 Amps with a resolution of 1mA over the frequency range of DC to 50 khz. The probe has two scales, 0 to 20 Amps and 0 to 40 Amps. The Snap-on Low Amp Current Probe outputs an analog voltage based on current flow through the circuit. The output is millivolts AC or DC. For example, in the 0 to 20-Amp range, the probe output is 100 mv per 1 Amp. In the 0 to 40-Amp range, the probe output is 10 mv per 1 Amp. Jaws Battery Cover Release Screw On/Off & Low Battery Indicating LED Battery Cover Zero Button On/Off & Range Selector Switch Figure 1 2

2.0 SPECIFICATIONS 2.1 Electrical Data Current ranges : 20A / 40A AC PEAK or DC Measuring range : +/- 20A / 40A Output sensitivity : 100 mv / 10 mv /A Accuracy (20A Range) : +/- 1.5% of reading +/- 5 ma Accuracy (40A Range) : +/- 1.5% of reading +/- 50 ma Resolution : +/- 1 ma / 10 ma Load impedance : >10 kohm and 100 pf Conductor position Sensitivity : +/- 1% relative to center reading Frequency range : DC to 50 khz (-3dB) Temperature coefficient : +/- 0.1% of reading / C Power supply : 9V Alkaline, MN1604/PP3 : 50 Hours, low battery indicator Working voltage (see Safety Standards section) : 150V AC (RMS) or DC. 2.2 General Data Maximum conductor size : 11 mm diameter Output connection : 4 mm safety plugs Output zero : Auto zero via push button Cable length : 1.5 meters Operating temperature range : 0 to +50 C / 32 to +122 F Storage temperature range : -20 to +85 C / -4 to +185 F Operating humidity : 15% to 85% (non condensing) Weight : 250 g / 0.55 lb 3

3.0 OPERATING INSTRUCTIONS Refer to Figure. 1 on page 2 3.1 Connecting the Probe To connect the probe to the Vantage equipment connect the red plug of the probe connector to CH1 and the black to COM. To connect to oscilloscopes use the Snap-on BNCto-Banana adaptor (EETA308A6). 3.2 Switch on When the probe is turned on, the RED LED illuminates. You will also notice that when the battery voltage is too low for normal operation, the LED flashes, to warn the user that the battery needs to be changed. The Battery Replacement procedure is described in section 5.0. 3.3 Low Amp Current Probe Zero Adjustment The Snap-on Low Amp Current Probe has a push button auto zero feature. The output zero offset voltage of the probe may change due to thermal shifts and other environmental conditions. To adjust the output voltage to zero: 1. Ensure that the probe is away from the current carrying conductor. 2. Connect the Low Amp Current Probe to your instrument and select the voltage scale to view the reading. 3. Turn the Low Amp Current Probe on by using the On/Off and Range Selector switch to select the 20A or 40A scale. Press the Zero button. 3.4 Error Factor Current probes work by reading the magnetic field around a conductor. The error factor is the amount of induced error or false reading from a current probe. Some current probes can have an error factor of over 100 ma. This induced error reading can be caused by many magnetic fields. Any device that generates a magnetic field can induce an error. Even the earth s magnetic field has an influence on current probes. To reduce the error factor, zero the Low Amp Current Probe in the same direction and inclination as intended use! 4

3.5 Reading the mv scale When reading the millivolt scale, remember that a probe setting of 100 mv equals 1 Amp (20 Amp scale on the Snapon Low Amp Current Probe). Similarly: A reading of: 0.8 mv = 8 ma A reading of: 1.8 mv = 18 ma A reading of: 21.8 mv = 218 ma A reading of: 100 mv = 1000 ma or 1A 3.6 Current Measurement Applications 3.6.1 Parasitic Draw Measurement Recommended Probe Setting: 20A scale Recommended Vantage Setting: 200 mv scale Note: Before taking measurements or clamping the probe jaws around any wire, complete the Setup steps below. Setup 1. Use the On/Off and Range Selector switch to select the 20A setting. 2. Perform the Low Amp Current Probe Zero Adjustment procedure (refer to section 3.3). Test To measure parasitic draw: 1. Clamp the Low Amp Current Probe jaws around the B+ supply wire to the power distribution box, or to the positive or negative battery cable. The parasitic draw readings display. 2. If a negative reading displays, open the probe jaws and clamp the probe in the opposite direction. Note: Computer-controlled vehicles require a small amount of current to keep module memories alive. Refer to the appropriate vehicle service manual for module time-out and maximum parasitic draw information. The term time-out refers to the amount of time that modules operate, before going into sleep mode. 5

3.6.2 Fuel Pump Current Measurement Recommended Probe Setting: 20A Recommended Vantage Setting: Waveform Viewer 0 to 1 Volt Note: Before taking measurements or clamping the probe jaws around any wire, complete the Setup steps below. Setup 1. Use the On/Off and Range Selector switch to select the 20A setting. 2. Perform the Low Amp Current Probe Zero Adjustment procedure (refer to section 3.3). Test Important Note: If the vehicle has more than one fuel pump, test each pump independently. To measure fuel pump current: 1. Clamp the Low Amp Current Probe jaws around the fuel pump voltage supply circuit near the fuel tank or at the fuel pump relay. 2. Verify that the probe jaws are fully closed. The fuel pump current readings display. 3. If a negative waveform displays, open the probe jaws and clamp the probe in the opposite direction. Humps in the waveform represent the condition of the pump commutator and brushes (Figure 2). Waveform humps are considered normal. Figure 2. As brushes wear, the waveform will degrade, and the pump speed may slow down (refer to Figure 3). Figure 3. 6

Tech Note If the fuel pump is difficult to access, it may be possible to check the fuel pump current at the fuse box (if applicable). To check the fuel pump current at the fuse box: 1. Locate fuse box and remove the fuel pump fuse. 2. Install an inline fuse harness in place of the fuse. 3. Clamp the Low Amp Current Probe around the inline fuse harness. Fuel Pump RPM Calculations Most fuel pumps run at about 5000 to 6000 RPM and draw about 6 to 8 amps. Pumps may cause driveability symptoms below 3000 RPM. Most fuel pump commutators have 8 segments. Using an 8-segment commutator as an example, RPM may be estimated by measuring the delta time of the 8 humps present in the waveform. One of the formulas to find RPM is 60,000 (the number of ms in a minute) divided by the time measurement of the 8 humps of the waveform. Let s say if in our example that the time measurement of the 8 humps is 12 ms, we would divide 60,000 by 12 to get 5000 RPM. To measure amperage, measure the average voltage of the waveform and use 100 mv = 1A for calculation. 3.6.3 Ignition Coil Current Measurement Recommended Probe Setting: 20A Recommended Vantage Setting: Waveform Viewer 0 to 1 Volt Note: Before taking measurements or clamping the probe jaws around any wire, complete the Setup steps below. Setup 1. Use the On/Off and Range Selector switch to select the 20A setting. 2. Perform the Low Amp Current Probe Zero Adjustment procedure (refer to section 3.3). Test To measure ignition coil current: 1. Clamp the Low Amp Current probe around the B+ side or the control side wire of the ignition coil. Do not clamp the probe around both wires. 2. Verify that the probe jaws are fully closed. The ignition coil current readings display. 3. If a negative waveform appears, open the probe jaws and clamp the probe in opposite direction. The ignition coil waveform should have a gradual rise or ramp as current begins to flow (refer to Figure 4). 7

Figure 4. If the vehicle is DIS equipped, current flow through each coil should be about the same. If the ignition coil waveform has a sharp rise at the beginning of the ramp upward, suspect shorted coil windings (refer to Figure 5). Figure 5. To measure amperage, measure the maximum voltage of the waveform and use 100 mv = 1A for calculation. Tech Note If the ignition coil is difficult to access, it may be possible to check the ignition coil current at the fuse box (if applicable). To check the ignition coil current at the fuse box: 1. Locate fuse box and remove the ignition or DIS fuse(s). 2. Install an inline fuse harness in place of the fuse. 3. Clamp the Low Amp Current Probe around the inline fuse harness. 3.6.4 Injector Current Measurement Recommended Probe Setting: 20A Recommended Vantage Setting: Waveform Viewer 0 to 0.2 Volt Note: Before taking measurements or clamping the probe jaws around any wire, complete the Setup steps below. Setup 1. Use the On/Off and Range Selector switch to select the 20A setting. 2. Perform the Low Amp Current Probe Zero Adjustment procedure (refer to section 3.3). 8

Test To measure injector current: 1. Clamp the Low Amp Current Probe around the B+ side or the control side wire of injector. Do not clamp the probe around both wires. 2. Verify that the probe jaws are fully closed. The injector current readings display. 3. If a negative waveform displays, open the jaws and clamp the probe in the opposite direction. Tech Note If injectors are difficult to access, it may be possible to check injector current at the fuse box (if applicable). To check injector current at the fuse box: 1. Locate the fuse box and remove the injector fuse(s). 2. Install an inline fuse harness in place of the fuse. 3. Clamp the Low Amp Current Probe around the inline fuse harness. On sequential fuel injected vehicles, each waveform represents current flow through one injector. On bank-fired injectors, each waveform represents current flow through the injector bank. The injector waveform should have a gradual rise or ramp as the current begins to flow through the injector or the injector bank. Current flow through each injector or injector bank should be about the same (refer to Figure 6). Figure 6. If an injector or an injector bank has high current flow, suspect a shorted injector (refer to Figure 7). Figure 7. If an injector peak is missing, suspect an open injector, wiring, or defective PCM driver circuit (refer to Figure 8). Figure 8 To measure amperage, measure the maximum voltage of the waveform and use 100 mv = 1A for calculation. 9

4.0 CURRENT PROBE CHARACTERISTICS 10

5.0 BATTERY REPLACEMENT The RED LED flashes when the minimum operating voltage is approached, indicating that the battery needs to be replaced (refer to Figure 9). When replacing the battery, use the 9-volt alkaline (PP3/MN1604) type only. Using any other type of battery in the Snap-on Low Amp Current Probe will invalidate your warranty. To replace the battery: 1. Unclamp the probe from the conductor. 2. Using the On/Off and Range Selector switch, turn the Low Amp probe off.. 3. Disconnect the output leads from external equipment. 4. Turn the battery cover release, Screw A, counter clockwise 90 degrees to loosen the screw. 5. Hold the battery cover at the top and pull the cover clear of the probe body as shown in Figure 9. The battery is then accessible. 6. Insert the new 9-volt alkaline (PP3/MN1604) battery. 7. Replace the battery cover by inserting the bottom of the cover into the base of the probe. 8. Re-tighten the battery cover release screw. Figure 9 11

6.0 CLEANING Clean the case periodically by wiping it with a damp cloth and detergent. Do not use abrasive cleaners or solvents. Do not immerse the probe in liquids. 12

7.0 WARRANTY SNAP-ON INCORPORATED WARRANTS THAT SNAP-ON ELECTRONIC DIAGNOSTIC PRODUCTS ARE FREE FROM DEFECTS IN WORKMANSHIP AND MATERIALS. Snap-on will repair or replace this product if it fails to give satisfactory service due to defective workmanship or materials. This warranty for Snap-on electronic diagnostic products is for ONE YEAR from the date of the original purchase. Repair or replacement shall be at the election and expense of Snap-on. Except where unreasonable, the product must be returned to Snap-on or a Snap-on dealer for warranty service. Snap-on does not provide any warranty for products subjected to abnormal use. Abnormal use includes misuse, modification, unreasonable use, neglect, lack of maintenance, use in production-related service, or use after the tool is significantly worn. Consumable products are not covered by any warranty. Consumable products are goods, reasonably expected to be used up or damaged during use, including but not limited to filters, ribbons, printer paper, gases, oxygen sensors, batteries and air conditioning leak detector tips. SNAP-ON SHALL NOT BE LIABLE FOR ANY INCIDENTAL, SPECIAL OR CONSEQUENTIAL COST OR DAMAGES INCURRED BY THE PURCHASER OR OTHERS (including, without limitations, lost profits, revenues, anticipated sales, business opportunities, goodwill, or interruption of business and any other injury or damage). Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you. This is your exclusive remedy and is in place of all other rights and remedies. You may have other rights, which vary from state to state or country. SNAP-ON INCOPORATED Kenosha, WI. 53141-1410 13

8.0 DECLARATION OF CONFORMITY D.O.C. No.: 65 Equipment Name/Type Number: EETA308A Low Amp Current Probe Manufacturer: Address: LEM HEME LIMITED 1 Penketh Place, West Pimbo, Skelmersdale, Lancashire, WN8 9QX. United Kingdom. European Standards: - EMC BS EN 61326 : 1998 Electrical equipment for measurement, control and laboratory use - EMC requirements Safety BS EN 61010-1 : 2001-02. Safety requirements for electrical equipment for measurement, control and laboratory use:- Part 2-032 : 1995 Particular requirements for hand held current clamps for electrical measurement and test. Part 2-031 : 1995 Particular requirements for hand held probe assemblies for electrical measurement and test. 150V Cat I Pollution degree 2. Description of Equipment: AC/DC clamp on current probe I certify that the apparatus identified above conforms to the requirements of Council Directives:- (1) Electromagnetic Compatibility Directive 89/336/EEC (2) Low Voltage Directive 73/23/EEC (3) CE Marking Directive 93/68/EEC Signed: Name: P.D.Morgenroth Research & Development Manager Date: 11/10/01 Company Name:- LEM HEME LIMITED. 1 Penketh Place, West Pimbo, Skelmersdale, Lancashire, WN8 9QX United Kingdom. Having made this declaration the CE mark may be affixed to the product, its packaging, instruction manual or guarantee certificate. 14

NOTES 15

NOTES 16

Snap-on Kenosha, WI 53141-1410 ZEETA308A Printed 10/01