BHARAT HEAVY ELECTRICAL LIMITED Boiler auxiliaries Plant Ranipet Vellore ,TamilNadu, India

Similar documents
Price Bid for DG Sets

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

Supply of 63 kva DIESEL GENERATOR SET WITH AMF

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU. INDIA CAPITAL EQUIPMENT/ MATERIALS MANAGEMENT

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

TENDER DOCUMENT TENDER No.: NRO / CON / 592 / 537 FOR SUPPLY & INSTALLATION. DG Sets & Sychronising Panel

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Annex A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 400V (750KVA) DIESEL

TECHNICAL SPECIFICATION FOR D G SET KVA

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

.3 Section Concrete Forms and Accessories: Installation of Anchor Devices, Setting Templates

LP 10. GENERATOR SPECIFICATION Power Rating (KVA) 10. Electric Power (KWe) 8. Rated Current (A) 14. No of Phases/Volts* 3/415

(High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT. Enquiry Date:

Technical Specification. for. Supply, installation and commissioning of Diesel Generators for UNDP

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS

Technical Specifications

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

: Material Description Quantity UOM

University of Houston Master Construction Specifications Insert Project Name

TECHNICAL SPECIFICATIONS FOR 380/410 KVA, 6 CYLINDER DIESEL GENERATOR SET PACKAGED BY SCOPE OF SUPPLY FOR DIESEL GENERATING SET PACKAGE

INTER PLANT STANDARD - STEEL INDUSTRY THYRISTOR CONVERTORS FOR ARMATURE AND FIELD OF MAIN DRIVE MOTORS. Corresponding IS does not exist

017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA

ANNEXURE XI. (Ni Cd Battery Bank) TECHNICAL SPECIFICATIONS OF 125V STATION BATTERY BANK OF GTG I.

045 : 2000 CEB STANDARD

SPECIAL SPECIFICATION 5066 Packaged Engine Generator System

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Inviting Tenders for Supply, Installation, Testing and Commissioning of 500 KVA DG Set for Temperature Controlled Warehouse at Medchal, Hyderabad.

INTER PLANT STANDARD STEEL INDUSTRY NO CORRESPONDING IS

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

NLC INDIA LIMITED (formerly Neyveli Lignite Corporation Limited) ('NAVARATNA'-Government of India Enterprise) MATERIALS MANAGEMENT COMPLEX

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

SPECIFICATION FOR AUTOMATIC PRIMING AND OPERATING SYSTEM FOR CENTRIFUGAL PUMPS.

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Rental Power QSB7 series engine

SPECIFICATIONS OF SINGLE GIRDER UNDER SLUNG E.O.T. CRANE CAPACITY: 5 MT

Mar H: SUPPLEMENTAL PARALLELING GEAR (16315-H)

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

.3 Section Waste Management and Disposal.

GMR - 67P 67P 09/05/2016 GMR - 067P

UK MANUFACTURED GENERATORS PS9P PS20P PERKINS 400 SERIES TECHNICAL DATA SHEET

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Diesel generator set QSX15 series engine

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

Energetech LLC 7427 S. Main (P.O. Box 400) Midvale, Utah (801) Ph. (801) Fx.

DG SYNCHRONIZING &AMF PANEL

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

FLOAT CHARGER (40A) & BOOST CHARGER (35A) FOR NO BREAK POWER SUPPLY SYSTEM WITH REQUIREMENT FOR SCADA

Rental Power QSL9 series engine

EMERGENCY GENERATOR SET

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

(A Government Company) CENTRAL WORK SHOP KOTHAGUDEM

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

BHARAT HEAVY ELECTRICALS LIMITED Industrial Valves Plant Goindwal (AMRITSAR) Enquiry Date:

Diesel generator set QSK50 series engine

UK MANUFACTURED GENERATORS PS100P PS150P PERKINS 1006 SERIES TECHNICAL DATA SHEET

FLOAT CHARGER & BOOST CHARGER F O R NO BREAK POWER SUPPLY SYSTEM (Float 100A & Boost 60 A with SCADA application)

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

SECTION 1 SCOPE, SPECIFIC TECHNICAL REQUIREMENT AND QUANTITIES

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

TECHNICAL SPECIFICATIONS FOR DIESEL GENERATORS kva (CANOPY TYPE) +15 GENERAL ATS PANELS

GUASCOR LEROY SOMER P 732 control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

ELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable All Cables Cables PVC Insulated Cables Fire Resistant Cables Aluminium Cables

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA

Standby Amper VOLTAGE

Standby Amper VOLTAGE

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

TENDER DOCUMENT PART-II

Standby Amper VOLTAGE

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

CORRIGENDUM/ ADDENDUM 09 ADDITIONAL REQUIREMENT OF ELEVATOR.

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Expert Design...Trusted Power

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK

TECHNICAL SPECIFICATIONS FOR BATTERY OPERATED HEAVY DUTY FORK LIFT TRUCK - 20 T

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Transcription:

NOTE:- BHARAT HEAVY ELECTRICAL LIMITED Boiler auxiliaries Plant Ranipet Vellore-632 406,TamilNadu, India Enquiry No. : Due Date : Supplier Qtn.No.: Date : Annexure - C: SPECIFICATION CUM COMPLIANCE CERTIFICATE 1X1010KVA DIESEL GENERATOR SET SYSTEM BAP/CAPITAL/2012-13/OT-5 1. The "Offer" Column and where applicable, the "Deviations" & "Remarks" Column of this format shall be filled in by the Vendor and submitted along with the offer. Inadequate / incomplete, ambiguous, or unsustainable information against any of the clauses of the specifications/ requirements shall be treated as non-compliance. 2. The offer and all documents enclosed with offer should be in English language only. NAME & ADDRESS OF THE SUPPLIER : TELEPHONE NOS.: FAX NOS.: E-MAIL ADDRESS : Part -1 Supply, Installation, Testing, Commissioning and proving the performance of 1010 KVA, 11 KV Diesel Generator, supplying standard accessories along with synchronising panel and 5No of VCBs with panels having AMF functionality. SI.No Description - BHEL's Requirement Specified Offered Deviations Remarks SCOPE: 1 GENERATOR SET 1010KVA 11KV DG set comprising of : engine developing suitable power at 1500 rpm complete with standard accessories coupled to alternator mounted on a channel iron base frame, Under NTP conditions of BS :5514 with an over load capacity of 10% for one hour in every 12 hours operation. 1.1 DIESEL ENGINE 1.1.1 Make Cummins/caterpillar/mitsubishi /Perkins/MTU 1.1.2 Model Vendor to specify 1.1.3 Cooling system: radiator cooled engine, mounted blower fan, engine mounted water pump, and thermo stat.initial filling of corrosion inhibitor coolant by vendor 1.1.4 Fuel system : Two nos of 990 ltr capacity fuel tanks with connected pipes lines/hoses, stand for two fuel tanks, over flow pipes,drain valves, air vent valves,strainers openings for inspection and cleaning with cover,level indication in the tank with scale to indicate the fuel stored, common outlet of two tanks should be connect to engine), full flow spin-on filters to the engine, fuel pump, injectors. Initial filling of fuel (high speed diesel )in BHEL scope. 1.1.5 lubricating system : oil pump, strainer, spin-on filter, pipes,intimate lube grade, capacity of sump,intial filling of lube oil by vendor. 1.1.6 Air intake system :dry type filter, air manifold with necessary connection,turbo charger with after cooler. Page 1 of 7

1.1.7 exhaust system : exhaust manifold, stainless steel flexible / pipe, canopy, residential silencer.heat resistance epoxy painting coat on pipe, insulation and hanger, support structurer starting from engine to side DG room ( aluminium cladding, chiken mesh mineral wool up to canopy, etc ), provision for temperature and pressure, test and measurement for checking compliance with statutory requirement. 1.1.8 PCB: stack of required height as per pcb norms has to be provided.emission shall be with in norms specified by Pollution control board and environment protection rules. Room design to be given by vendor.room construction by BHEL. 1.1.9 Governing system : electronic governer controller / class Vendor to specify 1.1.10 starting system :DC starter motor, battery charging alternator with in built regulator. suitable stand,suitable nos. of charged maintainace free batteries, with cable leads and terminal holders. battery make :exide/ amaron/cummins pulse / amco/prestolite/sf 1.1.11 Spare parts of filters Includes Lub Oil, Fuel& Air filter to be replaced up to 1000 hrs at free of cost whenever required. 1.1.12 Motor driven prime pump for lube oil 1.1.13 Cylinders in the Engine is Maximum of 12 Numbers 1.1.14 Fly wheel housing,flexible coupling,coupling guard, base frame :sturdy,fabricated, welded costruction, channel iron frame for mounting the above engine and below alternator. 1.1.15 Battery charger from mains 230V AC 1.1.16 Starting Electric & Battery Start 1.2 ALTERNATOR: 1.2.1 Power Rating (KVA) - 1010 KVA 1.2.2 Output Voltage & Frequency -11K V, 50 Hz 1.2.3 Frequency Regulation Vendor to specify 1.2.4 Power Factor (lagging) - 0.80 1.2.5 No.of Phases - 3 Phase + Neutral 1.2.6 Self regulated,brushless, horizontal mounted, single shaft with double bearing 1.2.7 Field Vendor to specify 1.2.8 Automatic Voltage Regulator suitable for parallel operation of generators Vendor to specify 1.2.9 Voltage Regulation (+/-1%)- no load to full load Vendor to specify 1.2.10 Insulation Class H Vendor to specify 1.2.11 Enclosure Vendor to specify 1.2.12 Make Kirloskar/Stamford/ToyoDenki/Leroysomer or equivalent Vendor to specify 1.2.13 Any other description Vendor to specify 1.3 NEUTRAL GROUNDING RESISTOR Page 2 of 7

1.3.1 1.3.2 Made of stainless steel of copper/nickel alloy Indoor metal Clad,dust & Vermim Proof Temperature riseup to 375 Deg.C above ambient temp Panel- Thermostat, star formation bus bar and lamp indication NGR Panel as per IS 8623,cubicle mounting type with front open arrangement with hinged door. Neutral Isolator Vaccum Contactor 1no of 11kv, 400A 1.4 Microprocessor based control panel for Alternator and Engine for monitoring, metering, control and protection against fault. with detailed specification 1.4.1 All control cables & their wiring are in the Scope of the Vendor. 1.4.2 Battery Voltage Sensing & Monitoring and charging current 1.4.3 Push Buttons for Manual Start / Stop 1.4.4 Manual Test -Mode Selector Switch 1.4.5 Annunciation, Alarm & Trip Features 1.4.6 Indications for DG "ON/OFF 1.4.7 Indications for MAINS "ON" for load 1.4.8 Indications for Over Current & Earth Fault 1.4.9 Coolant temp. 1.4.10 LOP 1.4.11 RPM indication 1.4.12 Service hour meter 1.4.13 Protection 1.4.14 High Water Temperature 1.4.15 Low Lube Oil Pressure 1.4.16 Over / Under speed 1.4.17 Air Filter Clog Indicator 1.4.18 Starting Failure 1.4.19 Generator Overload 1.4.20 Battery Voltage Low 1.4.21 Others Vendor to specify EARTHING 1.4.22 Neutral,Body earthing pits,including civil work in the scope of vendor 1.4.23 GI strip for DG set body earthing, copper strip for neutral earthing. 2 TOOLS FOR OPERATION & MAINTENANCE: Page 3 of 7 with detailed specification

2.1 Standard tools like Torque Wrench, Spanners, Keys, grease guns etc.for operation and maintenance Vendor to Furnish of the DG Set should be supplied. List of such tools should be submitted with offer. 3 SPARES: 3.1 Itemised breakup of mandatory mechanical & Electrical spares as per recommendation of Vendor for 2 years of trouble free operation should be offered by vendor. (Unit Price of each item of spare should be offered) 3.2 Complete list of spares for DG Set and accessories, along with specification / type / model, and name & address of the spare supplier shall be furnished along with documentation with circuit diagram to be supplied with the machine 4 DOCUMENTATION (To be furnished along with supplies): Three sets of following documents (Hard copies) along with the machine in English language should be supplied Vendor to furnish list 4.1 Operating & Maintenance Manuals & spare parts manual for the Diesel Engine 4.2 Operating & Maintenance Manuals for the Alternator 4.3 General arrangement plan of DG set. 4.4 Piping schematic diagram and engine control electrical circuit 4.5 Operating & Maintenance Manuals for synchronising panel & VCB panels 4.6 One additional set of all the above documentation on CD ROM, wherever possible. 4.7 Operation & Maintenance Manual for Batteries 5 ERECTION & COMMISSIONING at BHEL /RANIPET 5.1 Supplier shall be responsible for carrying out the Erection, start up testing and commissioning of the new DG Set and synchronising of existing 1000KVA, proving auto load sharing between the two gensets etc. Required technical personnel and labour required for the same shall be provided by the vendor. Tools, tackles, required for the same shall be a arranged by the vendor. Crane, if required, will be provided by BHEL free of cost. Service requirement like power, air & water shall be provided by BHEL at only one point at free of cost. 5.2 Erection of the Stack and thermal insulation of the exhaust system is also the responsibility of the vendor. 6 OPERATING CONDITIONS : 6.1 The DG Set should work trouble free and efficiently under following operating conditions: Height above MSL: 195 m Ambient Conditions: Temperature = 20 to 50 degree Celsius Relative Humidity = 95% max. 6.2 Weather conditions are tropical, Atmosphere may be dust laden during some part of the year. 7 APPLICABLE CODES & STANDARDS: 7.1 Rating Definition as per ISO 3046 / BS 5514 7.2 IS 4722 7.3 BS 5000 Page 4 of 7

7.4 IEC 34/1 7.5 ISO 8528 7.6 IS- 4889, 10000, 10002 7.7 Pollution Control Board directives with regard to exhaust stack height 7.8 Fuel conforming to IS 1460 7.9 Fuel consumption tolerance as per BS 5514 7.10 Environmental Protection Rules 8 Tests/Activities to be carried out at supplier s works in the presence of BHEL Engineers before dispatch : 8.1 Verification of Original test certificates for engine, alternator, room enclosure, and all other bought out items. 8.2 Run test of DG Set 9 Test /Activities to be carried out at BHEL works while commissioning the DG Set: 9.1 8 Hour Run Test 10 Foundation: 10.1 BHEL will carryout the civil work for foundations if any. Vendor shall provide details of the foundation for this purpose immediately after placement of LOI/P.O Vendor to Confirm 11 Guarantee 11.1 The DG set shall be guaranteed for a period of 24 months from the date commissioning or 5000 hrs from the date of commissioning whichever occurs earlier. 12 Coordination for Approval from Statutory Authority 12.1 Coordination for Approval from Statutory Authority all Input like Drawing & other Supporting Document & Coordination with the agency Vendor Scope SEB, CEIG,CEA,CPCB etc approvals in the scope of the vendor 1 Supply, Installation, Testing & Commissioning SYNCHRONISING PANEL Part-2 1.1 Synchronising panel with facility to synchronise new DG set with existing 1000 KVA DG set, 1500rpm 11kV, KIRLOSKAR alternator frame size: 4AB450/8, Engine:Mitsubishi. Connection: STAR, Excitation voltage:86, Excitation Ampere: 2.65A, Phase sequence:is4728, P.Code: FERT6598. Provision should be available to synchronise proposed 3rd DG set in the future. Synchronising logic panel comprising synchronising lamps, digital meters for generator/ Bus voltage/ frequency, synchroscope etc. as required. Vendor need to synchronise new DG set with existing old DG set and prove the performance of auto load sharing between them. 1.2 The existing genset and the new genset are to be placed approximately 35m apart.the incoming VCB panel to be placed in between the two gensets.the supply of power cables and adapter box for the connection between gensets and outgoing VCBs(via incoming VCB & synchronising panel ) is in the scope of the vendor. with any related specifications Page 5 of 7

2 VCB Panel with AMF functionality 2.1 Supply and erection of VCB panel consisting of 5No 0f VCBs.3 No.s for incoming and 1No of VCB for outgoing, and 1No spare for future purpose. VCBs should be compatible with our requirement of synchronisation. Vendor toconfirm The panel shall be made of sheet metal totally enclosed dead front pattern, free floor standing type to transfer the load from normal source to diesel generator emergency source. The transfer breaker shall be rated for continuous duty. The breaker shall be interlocked to ensure non-paralleling EB power supply and DG supply. All main contacts shall be protected by arcing contacts. Operation a) The normal source shall be constantly monitored by a mains voltage monitor. b) When mains voltage fails or drops below 70-80% of the rated voltage, the automatic control system shall give a starting signal to the two diesel generator sets. c) As soon as the two diesel generator sets reaches its operating speed and alternator its operating voltage, the load shall be transferred to the generator set and the breaker closing terminal shall be activated to operate the relay and close the breaker and operate all interlocks to ensure that normal supply input is activated and the main breaker trips. d) Upon the return of the normal source voltage of 90% of rated voltage for one minute the switch shall retransfer the load to the normal source and the interlock system described above reverses its operation. e) The automatic control system shall then reset itself and be in readiness to start the engine generator set upon the failure of the normal source(eb supply). f) If the diesel set fails to start or reach its operating speed in 40/50 seconds, in three attempts, the set shall automatically be disconnected and locked in isolated position. In such an event there shall be both a loud alarm and a visual indication.meanwhile the other DG set should be connected to the load. g) A test switch to simulate a normal source failure shall be provided for routine testing of the transfer switch panel and DG set. h) Time delay of minimum 3 seconds shall be provided for change over of supply in both directions. Vendor toconfirm Vendor toconfirm i)common auto/manual selector switch to be provided for selection of auto mode/manual mode of AMF function. j)individual auto/manual selector switch to be provided for selection of individual DG sets on auto/manual mode. Construction: a)panel shall be of sheet metal of minimum 2 mm thickness with adequate working space inside. b) Indication lamps shall be provided on the panel separately for grid supply and generator supply. c) There shall be facility for remote control of generator voltage and engine speed. Page 6 of 7

d) Reverse power relay shall be provided for the generator. e) Neutral switching facility shall be provided. 2.2 AMF, GENERATOR PROTECTION & SYNCHRONISING PANEL: 2.2.1 PLC Based AMF, Protection & Synchronising Panel Vendor to Confirm 2.2.2 Rating of Switchgear Vendor to Specify 2.2.3 Make of Switchgear (Shall be of reputed make like L&T, Areva, ABB, Siemens etc) Vendor to Specify 2.2.4 Bus Bars of suitable rating for incoming & outgoing terminations Vendor to Confirm 2.2.5 Overcurrent & Earth Fault relay to be provided Vendor to Confirm 2.2.6 Supply Failure Timer Vendor to Confirm 2.2.7 Restoration Timer Vendor to Confirm 2.2.8 Automatic Start / Stop of Engine Vendor to Confirm 2.2.9 Generator Voltage, Current & Frequency Monitoring & Display Vendor to Confirm 2.2.10 Battery Voltage Sensing & Monitoring Vendor to Confirm 2.2.11 Push Buttons for Manual Start / Stop Vendor to Confirm 2.2.12 Manual / Auto / Test -Mode Selector Switch Vendor to Confirm 2.2.13 Annunciation, Alarm & Trip Features Vendor to Specify 2.2.14 Indications for DG "ON", Load on DG Vendor to Confirm 2.2.15 Indications for MAINS "ON", Load on Mains Vendor to Confirm 2.2.16 Indications for Over Current & Earth Fault Vendor to Confirm 2.2.17 KW & KWH Meter Vendor to Confirm 2.2.18 Meter for Power Factor Vendor to Confirm 2.2.19 Instrument fuses duly wired Vendor to Confirm 2.2.20 SMPS Based automatic Float cum Boost Battery Charger with DC Voltmeter & Ammeter, Selector Vendor to Confirm Switch for Auto / Manual & Float / Boost 2.2.21 Synchronising logic panel comprising synchronising lamps, digital meters for generator/ Bus voltage/ Vendor to Confirm frequency, synchroscope etc. as required. 2.2.22 Power and control cables for interconnection within the system Vendor to Confirm 2.2.23 Complete technical details of the Panel Vendor to Furnish 2.2.24 The Panels, VCB etc. to be housed in indoor type control room. Room construction under the scope of BHEL. Vendor to give layout and indicate the approx. size of the room. Vendor to Furnish Vendors' signature with seal Page 7 of 7