Experience and History

Similar documents
WELCOME! Today we d like to Introduce you to your North American Rotary UPS Solutions Partner!

CONTINUOUS POWER IN YOUR CONTROL KEM5

Diesel UPS/CPS systems Continuous power

NO-BREAK KS. Dynamic UPS system PRESENTATION

Ride Through Solutions

Transforming Energy.. For Advanced Technology

Switchgear and Distribution Systems for Engineers and Technicians

D Series: UPS UPTO - 300KVA - Three / Three Phase

Master Plus kva

Introduction to Variable Speed Drives. Pekik Argo Dahono Electrical Energy Conversion Research Laboratory. Institute of Technology Bandung

MGE TM Galaxy TM 7000

PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Surabaya Seminar Ferdinand Sibarani, Surabaya, 30 th October Power Quality

Achieving the Highest Power Density in the Smallest Footprint

Power Protection Discrete Automation & Motion South Africa

Compact Energy Storage Module. Modular Systems, EPDS. Product overview

Power Electronics

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

3ph UPS NS3000 series kVA

Steve Schouten. Donna Densmore

MASTERYS IP+ 10 to 80 kva

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Standby Power Systems

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

MGE TM Galaxy TM 7000 GFC

MKN-DSP SERIES - THREE PHASE

Simply Reliable Solutions for Continuous, High Quality Power Tradition. Technology. Innovation.

TLE Series UPS 400/500 kw With eboost Technology

TECHNICAL DATA SHEET KVA UPS Systemss

Induction Motor Control

4100C BOSS AC Shovel Drive System Overview. WMEA Edmonton - June 2008

Industrial PFC UPS System

Reduction of Harmonic Distortion and Power Factor Improvement of BLDC Motor using Boost Converter

GENERATOR DATA MAY 10, 2018

GENERATOR DATA SEPTEMBER 29, 2015

Power Quality Solutions STATCOM, 100kVAr to 30MVAr Dynamic reactive power compensation

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Lesson 16: Asynchronous Generators/Induction Generators

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Diesel generator set QSK95 series engine

Est DCM Double Conversion Module 400kVA - 800kVA

Liebert. FP 50Z kva

Sources, Effect, and melioration. Power Quality Problems. Asnil Elektro FT UNP

Designing and Maintaining a Pollution-Resilient Electric Power System. Managing Pollution Issues

Master Plus kva

IEEE Northern Canada & Southern Alberta Sections, PES/IAS Joint Chapter Technical Seminar Series

GE Industrial Solutions ES Group / UPS Solutions. GE Flywheel UPS. Flywheel Energy. An Integrated Solution

TLE Series UPS 160/200/225/250 kw with eboost Technology

ABB n.v Power Quality in LV installations

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

Rental Power QSB7 series engine

SDC,Inc. SCR-Regenerative Ac Drive


Variable Frequency Drives

Pump ED 101. Power Factor (Part 2) - - Electricity Behaving Better

Power+ CLASSIC. 20/30 kva, 3x208 Vac

DRIVE THE WATER CYCLE. January 10 TH 2013

400/230 Volt 60Hz UPS Power

PI044G - Winding 06 APPROVED DOCUMENT. Technical Data Sheet

Integration of Large Wind Farms into Electric Grids

PI144J - Winding 05 APPROVED DOCUMENT. Technical Data Sheet

Synchronous Generators I. Spring 2013

Novel High Efficiency UPS System

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Diesel generator set QSX15 series engine

UPS5000-E (25-75 kva) Series

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

HIGH POWER RECTIFIER SYSTEMS

MERU Solar Off-Grid Inverters

Technical Data Sheets

Technical Data Sheets

Machine, Panel, and Plant Level Solutions

PQC - STATCON The ultra fast Power Quality Compensator

TLE Series UPS 750/1000 kw With eboost Technology

Synchronous Generators I. EE 340 Spring 2011

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

Workshop on Grid Integration of Variable Renewable Energy: Part 1

Technical Data Sheets

There are two leading power conversion technologies used in formation charging rectifiers

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Diesel generator set QSK23 series engine

POWERTRONIX QUASAR 5-40 KVA

Rental Power QSL9 series engine

Spec Information. Reactances Per Unit Ohms

Alberto Carini, June 2013 MNS irpp The ABB s Power Distribution Units

ECE1750, Spring Motor Drives and Other

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

2-marks question bank UNIT I - TRANSFORMERS UNIT II: AC MACHINES

Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.

BATTERY FREE DC ENERGY STORAGE FOR UPS. Yorba Linda CA (714)

Galaxy VM. From 160 kva to 1000 kva Three-phase power protection. apc.com/products

2 MW Flywheel System Integration

MGE Galaxy 5500 Marine

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

Power Electronics & Drives [Simulink, Hardware-Open & Closed Loop]

Transcription:

Experience and History 1956 Battery no-break 1994 New Mfg Facility 500kVA System 1974 1000kVA System IC with Inner Rotor 1963 4x1600 MV System 1969 First Diesel CPS System (300 kva) 1992 2250kVA Dual Output System 1996 1998 2000 2003 Move to Almelo New Mfg and Test Stand 1600kVA System 1994 2750kVA Dual Output 2004

Major Components Choke 80% - 20% Tap - Direct Connection Provides Isolation for Load Part of Active Filter Impedance Matched with Generator Induction Coupling Outer Rotor Inner Rotor 1800 rpm 2 pole AC Winding DC Winding Diesel Engine Engine is preheated Engine is pre-lubricated Gravity fed fuel system Starting redundancy (n+2) Two starting motors Two starting batteries Direct Generator Start Options Starting ONLY the diesel engine clutch open generator already running Generator 1.4 to 1.6 times rating 4 Pole AC Winding 1800 rpm Active Filter

WHAT WE DO The Problems 1- Spikes 2- Frequency Variations 3- Voltage Sags 4- Outages 5- Harmonic Distortions 6- Transients The Solution The RESULT 7- Continuous Quality Power

Power Conditioning Voltage Regulation 1% Frequency Regulation 1% Harmonics Attenuation, THD < 3% Power Factor Improvement, >PF 0.98 Peak Voltage Protection

HARMONIC FILTERING - Peak Voltage Protection High impedance path from Supply to Load through the Choke blocks Supply harmonics Z Input = 55% Z Choke = 50% Z = 49% Z = 1% Z Output = 7% --- --- Low impedance path from Load to Earth through Alternator absorbs Load harmonics Z Gen = 6% 1. Removes harmonics generated by both the load and the mains supply 2. No power electronics (e.g. Input rectifiers) are incorporated in design

Voltage Regulation PF Improvement Input pf is maintained at pf 0.98 or greater for almost all load conditions Active Power supplied by utility Supply Load --- --- Reactive Power supplied by alternator The Synchronous Alternator supplies all of the Reactive Power demanded by the load with the Mains supplying only Active Power

Fault Clearing Capabilities Upstream Short-circuit Downstream Short-circuit Up to 2xFLC Up to 14xFLC The Generator will maintain the supply to the load within Specification while supplying up to 2xFLC to an upstream fault

Complete UPS Solution!!!!!! 1800 kva CPS at 100% Load Mains Failure Main Voltage Output Voltage 1800 rpm Frequency 60.5 Hz 60 Hz 59.5 Hz Free-wheel Clutch Engaging Diesel Speed 1 sec. Diesel Start

ALL in ONE SOLUTION Diesel Engine Alternator Induction Coupling PFC Air Conditioning Standby Batteries Busduct & Cabling Fire Protection & Security UPS Inverters Spark-proof Lighting

HIGH Power SMALL Footprint <2400 sq ft (280sq meter) 5400 kva Total CPS 1350 kva Essential CAPABLE of 3kVA/sq.ft.

HIGH Efficiency Lower Operating Costs Efficient Total losses <4% 100% 97% Hitec UPS Inefficient Total losses >10% 100% <90%

PRODUCT CAPABILITIES Single Output CPS Units from 400kVA to 2750kVA 380V to 25kV 50 or 60 Hz Systems Containerized or Indoor Installation Plug & Play Modules Dual Output CPS Parallel Systems Medium Voltage Systems Isolated Redundant Distributed Redundant Master Slave

TECHNICAL FEATURES OF THE SOLUTION Uses Stored Kinetic Energy - 60 Hz Technology Easily Paralleled MV Applications up to 19,800kVA Integrated Power Factor Correction near Unity at Input Very Effective Filter for Spikes and Harmonic Distortion High Non-Linear Load Capability High Peak Current Capability (typical 10-15 In.) Very Efficient with Low Operational Costs

REASONS WHY HITEC IS POWER TO RELY ON High Power in Small Foot Print - 3kVA/Sq Ft Nationwide and Global Service Organization 7/24/365 Hard, Resilient, Electrical System - 1% Regulation Unlimited Configurations and Installation Options NO Air-Conditioning and Associated Costs NO Battery Room Maintenance/Monitoring/Disposal Costs NO Energy Conversion in Power-Path

REASONS WHY HITEC IS PEOPLE TO RELY ON Worldwide and LOCAL Service Technicians Help desk available 7/24/365 Remote monitoring and diagnostic systems Engineer COST EFFECTIVE SOLUTIONS Responsive Project Management After The Sale On Site Customer Training

LESSONS LEARNED ACTIONS TAKEN Continual Process and Product Improvements Developed First Class Service Organization Improved Communications and Responsiveness Customer Oriented Business

RELY ON HITEC POWER PROTECTION WWW.HITECUSA.COM 1-800-794-9398