3M Ionized Air Gun 980/980E. User s Guide

Similar documents
3 980/980E Ionized Air Gun Instruction Manual

3M Ionized Air Gun 980/980E. User s Guide

AirForce Ionizing Blow-off Gun. Model User s Manual

IONIZATION SOLUTIONS. AirForce Ionizing Blow-off Gun. Model User s Manual

3M No Polish LC/APC Connector SM, Angle Splice, 250/900 µm 8830-APC/AS

3M No Polish LC Connector SM and MM, Flat Splice, 250/900 µm

INSTRUCTIONS. Owner's Manual. Ionizing Air Nozzles Models AN-2 and AN-6

IONIZATION SOLUTIONS

3M Locator Plate

Cable Ties. Data Sheet

746 Wrist Strap Tester Installation, Operation and Maintenance

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900-µm. Instructions. October C

3M Test Kit for Static Control Surfaces 701. User s Guide

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900 µm Instructions

3M Pleated Foil I/O Cable Assemblies MDR Series

3M Locator Plate

3M Cross-Connect Cabinets 4220SVC and 4220SVE Tall Skirt Installation Guide

Cold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN

Data Sheet July For RoHS information, please visit

Volition. VF-45 Quick Install kit. and Maintenance Cleaning Kit. 3Innovation

3M Ladder Kit 3M710/MS 2 -TMK-LK

3M Closure System 2-Type Cover (505)

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW)

710 Splicing Rig. Instructions. January E

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

Door Edge Protection Film 36 inch

3M Mini D Ribbon (MDR) Cable Assembly.050 High Speed Video Data Transmission System, 50 Position 14X50-SZWB-XXX-0NC

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TS (RW)

Finish Line. Redefining The. NEW 3M Elite Series Air-Powered Random Orbital/Orbital Sanders NEW 3M Electric Random Orbital Sanders

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

Switching DC Power Supply

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

3M Mechanical Shearbolt Connectors, QCI Series

3M CP2 Press-Fit Headers and Sockets, 2 mm

Model 1100B CHG Terminator. Installation Instructions

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

INSP-3 Wiring Inspection Tester

Installing the Boom Mount ET 350 Monitor (Model ET 350R)

3 740 Wrist strap + shoe tester

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series

3M Textool Test and Burn-In Sockets for 1.0 mm Area Array Packages Including Ball Grid Array and Land Grid Array

Air Actuated Hydraulic Bottle Jacks

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

3M Cold Shrink QT-III Silicone Rubber Termination

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT

INSTRUCTIONS Operation / Maintenance

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Technical Data 3M Petroleum Sorbents

G E N E S I S R O C v AUTOMATIC REPLENISHMENT MODULE

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

362 Clamp Meter. Users Manual

3M Three-Wall and Four-Wall Headers. Series 3XXX

DOCUMENT OBSOLETE. Volition. VF-45 Socket Termination and Maintenance Cleaning Kits COOL HAND TOOLS. CLEAN UP YOUR ACT. VF-45 Socket Termination Kit

Spotlight 1,000,000 Power Series Cordless Rechargeable

Intended Use: Explanation of Signal Word Consequences

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Motor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables)

3M Cold Shrink Splice Kit QS-III 5536A

3M Collision Repair Solutions. 3M Abrasives and Power Tools. Cutting & Grinding. for Body Techs

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

3M Fiber Dome Closure FDC 10

Dual Flow Manifold Systems Instruction Manual

Operating Instructions & Parts Manual. Supa-Lite Lever Grease Gun. Model 48UJ77

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

3M TM Cubitron TM II Bonded Abrasive Grinding and Cut-Off Wheels. born to. grind. It s grinding reinvented. Featuring. cut & grind wheels

VWR Zero Air Generator

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

Illumifalls Patio Pond

3M Cushion-Mount Plus Plate Mounting Tapes with Easy Mount Adhesive

3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv

GM Specification Annual Test Data

PET UNIT DOSE CABINET

Visit us at

ValveMate 7000 Controller Operating Manual

GM Specification Annual Test Data

365 Detachable Jaw True-rms Clamp Meter

QSB (Q-Star) Electronics for QSE Electromagnetic Meter. Owner s Manual TABLE OF CONTENTS

SAFETY INFORMATION & INSTRUCTION MANUAL

3MTM CubitronTM II Bonded Abrasive Grinding and Cut-Off Wheels. BORN TO GRIND. IT S GRINDING REINVENTED.

IR-500 Infrared Thermometer / Voltage Detector / Flashlight

Research Isometric Transducer

OMEGA CORDLESS SERIES VACUUM INSTRUCTION MANUAL

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

3M Cold Shrink QT-II Silicone Rubber Indoor Termination Kits

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

Scale Feeder Manifold Water Filtration System Instruction Manual

MULTI-CHARGER FOR 12 TO 18V NI-CD OR LI-ION BATTERIES

Operating Instructions & Parts Manual. Air/Manual Hydraulic Bottle Jacks

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

4-VOLT LITHIUM-ION AUTO-LOAD SCREWDRIVER w/led WORKLIGHT

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J

Transcription:

3M Ionized Air Gun 980/980E User s Guide 1

Index Section Page 1. General Description... 3 2. Performance... 3 3. Power Requirements... 3 4. Air Supply Requirements... 4 5. Installation... 4 6. Assembling the Components... 5 7. Operation... 6 8. Maintenance... 7 9. Specifications... 10 2

1.0 General Description The 3M Ionized Air Gun 980/980E provides efficient static charge neutralization by effectively removing particle contamination even on some of the most static-sensitive products. The Ionized Air Gun 980 operates from 120VAC power, and the Ionized Air Gun 980E from 230VAC power. All references to model 980 throughout this user s guide pertain to both of the models, unless otherwise noted. Proprietary technology provides constantly balanced ionization for consistent control of surface charges. The Ionized Air Gun 980 virtually never needs adjustment and requires very little maintenance. Compact and lightweight, the console for the Ionized Air Gun 980 can be mounted almost anywhere on the workstation for easy access. It connects to asupply of clean, dry air or nitrogen, and an internal disposable filter collects particles from the air supply. The electrical feed from the console to the Ionized Air Gun 980 is incorporated into the light, flexible air hose. The Ionized Air Gun 980 itself is very lightweight and ergonomically designed for long-term user comfort and efficient operation. The console, Ionized Air Gun 980, and air hose are all designed to be static-dissipative and ESD-safe. 2.0 Performance The Ionized Air Gun 980 helps reduce a static charge of ± 1000V to ± 100V in less than 1 second at a distance of 6 inches (15 cm) and 30 psi (2 bars) inlet pressure when tested in accordance with the ESD Association ionization standard ANSI/ESD-S3.1. Balance variance is within ± 70 volts of zero at a distance of 6 inches (15 cm). 3.0 Power Requirements The Ionized Air Gun 980 console requires 24VAC power, which is provided by the transformer supplied with the unit. An 120AC transformer is supplied with the Ionized Air Gun 980, and 230VAC unit is supplied with the Ionized Air Gun 980E. 3

4.0 Air Supply Requirements For maximized operation, the 3M Ionized Air Gun 980 should be supplied with clean, dry air, or nitrogen. Please note that the failure to use clean, dry air or nitrogen may result in damage to the Ionized Air Gun 980 that will not be covered by warranty. 5.0 Installation Choose a location convenient to the work area and to the air supply. The console takes up very little space and is adaptable to a variety of permanent or nonpermanent installations. To minimize bends in the air Ionized Air Gun 980 hose, orient the console so that the open end that accepts the filtered air hose to the hand unit points toward the work area, and the male connector points toward the air supply. See Figure 1. Figure 1 5.1 Mounting the Console Prior to mounting, plug the end of the 10 foot (3 m) RJ-11 cable from the power supply into the jack on the back of the console. Lay the cable inside the groove inside the console. Mount the console using the instructions below. 5.2 Permanent Mounting Attach the supplied mounting plate to the threaded holes on the back of the console, using the supplied screws. See Figure 1. Attach the plate to a flat surface, such as a wall or back of a workbench, using suitable screws and fasteners. When mounting to a hollow wall, be sure to use adequate screws and wall anchors to ensure stability of installation. 4

5.3 Non-permanent Mounting Use 3M Dual Lock Fastener Strips or pads to attach the console to a flat surface. 5.4 Mounting onto an Air Supply When an air supply is close to the work area and fitted with a U.S.- standard industrial interchange quick coupling, you can attach the console to the air supply fitting directly using the female quick coupler provided with the console. If a U.S.-standard industrial interchange quick change is not available on the air supply, be sure to use a suitable interconnect between the air supply and the console, including a prefilter as defined in Section 4.0. 6.0 Assembling the Components CAUTION Protect the hose from sharp objects, abrasion, and high temperatures. Do not pull or pinch the hose while assembling the components. 6.1 Insert the larger end of the filter cartridge into the fitting at the end of the flexible air hose. Push the filter gently until it is firmly seated and the metal Filter Release Tab pops out, locking the filter into place. See Figure 2. 6.2 Connect the hose and filter to the console. First, push the Filter Release Button (Figure 3) in all the way. Then, push the fitting containing the filter all the way into the opening in the console until it latches with a click. The fitting fits only in the correct orientation. The small plastic fitting on the end of the filter must align with the metal guide coupling in the console. You may have to wiggle the filter slightly while inserting it. See Figure 3. Figure 2 5 Figure 3

6.3 Connect the male (air inlet) fitting on the console to the air supply. The console is designed for a U.S.-standard, industrial interchange quick coupling. You can attach the console directly to the air supply using the female quick coupler provided with the console, or attach it using a hose (not supplied) or some other interconnect. In both cases, use a prefilter as defined in 4.0. 7.0 Operation WARNING The 3M Ionized Air Gun 980/980E is NOT for use in hazardous environments where the possiblity of explosion exists. 7.1 Make sure the Power Switch on the top of the console is in the OFF position. Insert the power cord to the transformer into a properly grounded 120VAC (for Ionized Air Gun 980) or 230VAC (for Ionized Air Gun 980E) receptacle. Use only the correct transformer, as use of an incorrect wall transformer may result in damage to the unit. Doing so will void the warranty. Refer to Section 3.0 for additional information. 7.2 Secure the power cord so that it cannot accidentally pull the console and Ionized Air Gun 980 off the workbench. 7.3 For safety and the most efficient ionization, set the pressure regulator on your air or nitrogen supply between 20-65 psi (1.4-4.5 bars). Discharge times vary depending on air pressure. Note: Pressures of 30-40 psi (2.0-2.8 bars) are commonly used for decontaminating surfaces. Please refer to the pertinent regulations concerning maximum air pressure on hand-held air blow devices in order to determine a safe operating pressure. The unit is rated at 65 psi (4.5 bars) inlet pressure, at temperatures up to 75º F (24º C), and the rating decreases at higher temperatures. When using high pressures, consider the ambient room temperature as well as heat from surrounding equipment. 7.4 Verify that the Ionized Air Gun 980 trigger is not depressed. Turn the power switch on the console to ON. The green LED on the console should illuminate. 6

7.5 Hold the 3M Ionized Air Gun 980 approximately 6 inches (15 cm) from the surface you want to discharge and blow off. Aim the Ionized Air Gun 980 and press the trigger to blow ionized air. The green LED on the back of the Ionized Air Gun 980 lights up while you press the trigger, indicating that the Ionized Air Gun 980 is ionizing. Typically, static electricity on a surface will be discharged within one second. Release the trigger when the surface is assumed to be clean. 7.6 If the Ionized Air Gun 980 is not in use, it is recommended that the Power Switch on the console be turned off. This will avoid unintentional operation of the Ionized Air Gun 980. The included S-hook may be used to hang the Ionized Air Gun 980 out of the way but still within reach. 8.0 Maintenance The Ionized Air Gun 980/980E requires very little maintenance. Occasional cleaning of the case and emitter points, and periodic replacement of the air filter are all that is required. Always be sure to protect all components from liquids and corrosive chemicals. Carefully follow these maintenance instructions. CAUTION Always disconnect power and air supplies before cleaning or replacing components. 8.1 Cleaning the Components 8.11 Using a cloth moistened with isopropyl alcohol, wipe the exterior surfaces of the console and Ionized Air Gun 980 to remove any dirt or dust that may have collected. 8.12 Using a swab moistened with isopropyl alcohol, gently clean the emitter points on the Ionized Air Gun 980. Extremely dirty emitter points will increase the time needed to discharge static. 7

8.2 Replacing the Air Filter 3M recommends changing the filter every three months or when it begins to look dirty. Replacement filters are available from 3M (see Table 1). 8.21 Hold down the filter release button on the side of the console. 8.22 Remove the hose and filter from the console by pulling the textured rubber plug where the hose emerges from the console. Rocking the plug back and forth can help loosen the filter. Do not pull the hose itself. Remove the filter from the hose fitting by depressing the metal release tab on the fitting and pulling the filter. 8.23 To install the new filter, follow the directions described previously under Sec. 6.0. 8.3 Replacing the Emitter Points The emitter points, built into the plastic tip of the Ionized Air Gun 980, usually last the life of the unit. However, the tip should be replaced if it is broken, or if the points are bent, broken, otherwise damaged, or if you are unable to remove dirt by cleaning the points with isopropyl alcohol. A replacement tip containing a pair of emitter points is available from 3M (see Table 1). 8.31 Insert the tip of a screwdriver into the slot on the 3M Ionized Air Gun 980 barrel. See Figure 4. 8.32 Using the screwdriver as a lever, loosen the old clip, grasp it between your thumb and forefinger, and detach it from the Ionized Air Gun 980. The emitter points are very sharp; touch only the plastic lip, and handle it carefully. To avoid damaging the points, do not touch them with hard objects such as a screwdriver. 8.33 To insert the new emitter points, hold the Ionized Air Gun 980 with the barrel pointing up. 8.34 Grasp the new clip between your thumb and forefinger, and align it so the curved edges match the curve of the inside of the Ionized Air Gun 980 barrel. 8

8.35 Align the blunt prongs of the emitters with the holes in the 3M Ionized Air Gun 980 barrel and set the clip into place. 8.36 Press the clip all the way in using the tip of a screwdriver. It should fit snugly between the raised rim of the barrel and the raised rim of the air nozzle. If the clip overlaps the air nozzle, it is installed backward. Table 1: Replacement and optional parts Figure 4 Part Part # Status 120VAC Wall Transformer 960/980X Replacement 230VAC Wall Transformer 980E-X Replacement Air Filter 3-Pack 980-F Replacement Emitter Points 980-T Replacement 9

8.4 Replacement & Optional Parts Table 1 lists the replacement parts and optional parts available for the 3M Ionized Air Gun 980/980E. 8.5 Testing for Proper Operation 8.51 To make sure that your 3M Ionized Air Gun 980 is working properly, check the balance and discharge levels. The performance of the unit should be measured periodically using a charged plate monitor, such as the 3M Charge Analyzer 711 or the 3M Static Sensor 718. 8.52 Calibration should be performed in accordance with the ESD Association ionization standard ANSI/ESD-S3.1. At a line pressure of 30 psi (2 bars), discharge of ± 1000 volts to ± 100 volts should require less than 1 second at a distance of 6 inches (15 cm) and balance should be within ± 70 volts of zero. 9.0 Specifications for 3M Ionized Air Gun 980/980E 9.1 General Audible Noise 73dBA @ 1 meter, 30 psi (2 bars) pressure to air gun Ozone <0.005 ppm (24 hour accumulation) Certifications culus for Ionized Air Gun 980 CE for Ionized Air Gun 980E 9.2 Hand Unit Construction Static-dissipative polycarbonate Ion Emission Steady-state DC Emitter Points Tungsten alloy Ion Indicator Green LED Air Hose 7 (2.1m) length, 3/8 (0.96 cm) outside diameter of static dissipative polyurethane Gun Hanger #302 stainless steel Dimensions 8.0 L x 3.0 W x 1.0 D (20.3 cm L x 7.6 cm W x 2.5 cm D ) Weight 12.0 oz. (341 g) with 7 (2.1 m) air hose 10

9.3 Console Construction Input Power Power Static-dissipative polycarbonate 24VAC, <10 Watts, powered from transformer Indicator Green LED Air/Gas Input 20-65 PSI (1.4-4.5 bars), clean dry air or nitrogen For safety purposes, this unit has been tested at 1.5 times these air pressures. Air/Gas Connection 1/4" (0.64 cm) male US-industrial interchange quick disconnect and 1/4" (0.64 cm) NPT female coupler Air Filter 99.9% efficient, 0.1 micron or larger Mounting Metal mounting plate attaches to back of the unit Dimensions 8.5" L x 3.0" W x 1.6" D (21.6 cm L x 7.6 cm W x 4.1 cm D) Weight 11.5 oz (326 g) 9.4 Transformer Input 3M Ionized Air Gun 980: 120VAC (960/980X) 60 Hz 410A 3M Ionized Air Gun 980E: 230VAC (980E-X) 50 Hz 250mA 24VAC, 1670 ma 10' (3 m) cable with RJ-11 connectors (from power supply transformer) Output Power Cabling Dimensions 8 H x 8 W x 2.3 D (203.2 mm H x 203.2 mm W x 58.42 mm D) Weight 4 lbs. Certifications culus, RoHS, RoHS (China) (120VAC model) CE, RoHS, RoHS (China) (230VAC model) 10 Package Contents 1 ea. Air Gun 1 ea. Console 1 ea. Air Hose 1 ea. Power Supply 1 ea. User s Guide 11

Regulatory Information This symbol, per Marking for the Control of Pollution Caused by Electronic Information Products, SJ/T11364-2006, means that the product or part does not contain any substances in excess of the maximum concentration values as per Electronic Industry Standard of the People s Republic of China, SJ/T11363-2006, Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products. This information represents 3M s knowledge and belief, which may be based in whole or in part upon information provided by third party suppliers to 3M. In the event any product is proven not to conform with the material contentrelated information in this product literature, then 3M s entire liability and Buyer s exclusive remedy will be in accordance with the Warranty stated below. e-waste Disposal-Recycle according to applicable local, state and federal laws for electrical/electronic waste. RoHS 2011/65/EU Compliant means that the product or part does not contain any of the substances in excess of the maximum concentration values ( MCVs ) in EU RoHS Directive 2011/65/EU. The MCVs are by weight in homogeneous materials. This information represents 3M s knowledge and belief, which may be based in whole or in part on information provided by third party suppliers to 3M. WEEE Statement The following information is only for EU-members States: The mark shown to the right is in compliance with Waste Electrical and Electronic Equipment Directive 2002/96/EC (WEEE). The mark indicates the requirement NOT to dispose the equipment as unsorted municipal waste, but use the return and collection systems according to local law. culus Statement Meets culus requirements. CE Statement ElectroMagnectic Compatibility Statement: Meets 2004-108-EC Directive. Low Voltage: Meets 2006-95-EC Directive. 12

Customer and Technical Service Within the U.S.: Customer service and technical support can be obtained by calling the 3M Electronics Materials Solutions Division Customer Service: 866-722-3736 Outside of the U.S.: For customer service and technical support, please contact your local representative of the 3M Electronics Materials Solutions Division. UL Listed to U.S. and Canadian Safety Standards. Mark of Conformity to European Directives (Conformité Européene). 3M is a trademark of 3M Company. Important Notice All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for one year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. 3 Electronics Materials Solutions Division Static Control Products 926 JR Industrial Drive Sanford, NC 27332-9733 Toll-Free: 866-722-3736 International: 919-718-0000 Email: 3mstaticinfo@mmm.com www.3mstatic.com Please recycle. Printed in USA. 3M 2014. All rights reserved. 78-9102-1498-6 JHA RoHS 2011/65/EU