XT IEC Power Control Manual Motor Protectors

Similar documents
1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

IEC Contactors & Starters XT IEC Power Control

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Selection Guide Motor Control Device Solutions

Bulletin 190-M Compact Starters. Selection Guide

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Selection Guide. Control Circuit and Load Protection

Catalog Number 1NO-1NC 5 XTPAXSA11 5 XTPAXSAC

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

A302DN.40/.63A Thermal Current Motor Starter

PowerPact B. Molded case circuit breakers and switches from A

Control Circuit Protection

Enclosures. See Section Typical Description

Self-protected Combination Starters System PKZ 2-SP

3. Coils shall be of molded construction

Devices for Branch Circuits and Feeders

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

AF series contactors (9 2650)

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Industry Automation Control Components

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

1489-M Circuit Breakers

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Protection Equipment. 5/2 Introduction

Motor Protection Circuit Breaker and Motor Circuit Protector Specifications

MS General Information Extended Product Type: MS

Manual motor starters Overview and benefits

LOW VOLTAGE SWITCHGEAR

Motor Starter Protectors

Manual Motor Starters. Meta-MEC

AF series contactors (9 2650)

Products :: Circuit Protection :: Thermal Circuit Breakers

Multi-Pak Group Control

Contactors Low Voltage

C E R T I F I C A T E O F C O M P L I A N C E

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

NEMA Contactors & Starters (Freedom)

Motor Starter Protectors

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Bulletin 140M Motor Protectors

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Motor-protective circuit-breakers PKZ: now better than ever

Protection Equipment

ACS motor protection circuit breakers KT 7 Introduction

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control

3 - Protection components Motor circuit-breakers

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Series L9 UL489 Miniature Circuit Breakers

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Essential equipment for all your requirements

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Miniature Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MPCB. We touch your electricity everyday! State of the art Manufacturing Facilities. Haridwar, Noida Ph-I & Noida Ph-II Plant

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Short form catalogue Motor protection and control Manual motor starters

General data 5/37. Overview

UL/CSA Non-fused Disconnect Switches

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

KT4 Manual Motor Starter

FMotor Circuit Controllers

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

Technical Information

2.1. NEMA Contactors and Starters

Short-Circuit Current Ratings

Technical data for manual motor starters Type MS325

PKZ and PKE motor-protective circuit-breakers

Series L9 UL-489 Miniature Circuit Breakers

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

4.1. Definite Purpose Contactors and Starters. Contents

MAGNETIC MOTOR STARTERS

CI-TI Contactors and motor starters Types CI 61 - CI 98

Reduced Voltage Motor Starters

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Definite Purpose Contactors and Starters

Ideal for use as a manual starter

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Motor Protection. Presented By. Scott Peele PE

Short form catalogue. Motor protection & control

Bulletin 1489 Circuit Breakers. Selection Guide

KT7. Methods. of Applying. & Molded Case Circuit Breakers F119. Motor Circuit Controllers

3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

US Catalog January Motor protection and control Manual motor starters, contactors and overload relays

D509E. Manual Motor - Starters

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

Definite Purpose Contactors and Starters

Definite Purpose Contactors and Starters

Definite Purpose Contactors and Starters

Overload Relay Heater Tables

UL Enclosed Disconnect Switches (Fused and Non-Fused)

Motor Applications Automation. Command and Signalling Power Management Product Overview for Machinery

Protective Devices: Circuit-Breakers 1 )

Transcription:

May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted Current I u = I e (Amps) Adjustment Range / Overload Release I r (Amps) Short Circuit Release I rm (Amps) Maximum Motor Ratings Maximum kw Rating AC- P (kw) -Phase 0 V 80 V 0V 0V 660 60V Maximum hp Rating P (hp) UL 8/CSA C.2 No. -Phase 0V V 80V 600V Screw Terminals Frame B 0.6 0.2 0. 0.6.6 2. 6. 2 6 2 2 Frame D 6 2 2 0 8 6 0. 0.6 0.6 0.2 0.2 0. 0. 0.6 0.6.6.6 2. 2. 6. 6. 8 2 6 6 2 2 2 6 6 2 2 2 2 0 0 8 6..6 8.8 6 88 0 68 280 8 8 60 700 82 882 0.0 0.2 0.2 0.7 0.7... 7.. 7. 7 8. 0.0 0.2 0.2 0. 0.7.. 7. 2. 7. 2. 0.2 0.8 0.2 0.... 0.2 0.2 0.7 0.7.. Select by full load amperes. Maximum Motor Ratings (kw, hp) are for reference only. In this range, calculate motor rating according to rated current. Specified values to NEC Table 0.2. number shown comes with screw terminals. For Frame B devices up to 6A, spring cage terminals are available. For spring cage terminals on line and load sides, insert a C into the catalog number in the th position Example: C_BC. For spring cage terminals on the load side only, insert an SC into the catalog number in the th and 6th positions Example: SC_BC. Notes: Single-phasing sensitivity to IEC/EN 607--, VDE 0660 Part 2. Can be snap-fit to IEC/EN 607 top-hat (DIN) with 7. or mm height. Service Factor (SF) Setting I r of current scale in dependence of load factor: SF =. -> I r = x I n mot SF = -> I r = 0. x I n mot For manual motor protective circuit breaker switching capacity, see Page 6. 2 0 2. 2. 7. 0 7 7 2. 2 0 7 0.2 0.8 0.2 0... 7. 2. 0 2. 0 /2 -/2 /2 -/2 /2 / 2 2 2 0 0 0 /2 -/2 0 2 0 0 0 P6BC P2BC P0BC P6BC 00BC P6BC 2PBC 00BC 6PBC 0BC 02BC 06BC 0BC 02BC 02BC 06DC 02DC 02DC 00DC 0DC 08DC 06DC... 60. 60. 60. 60. 60. 60. 60. 7. 7... 2. 07. 07. 07..... Technical Data..................... Page Discount Symbol................... CD7 CA00700E

8 Product Family Overview May 07 Contents Description Page Selection................ Product Selection.......... 2 Accessories............... 7 Technical Data and Specifications............ Dimensions............... 67 Reference Data............. Pushbutton Rotary Product Description Eaton s new XT family of Manual Motor Protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class adjustable bimetallic overload relay and fixed magnetic short circuit trip capability in one compact unit. Two frame sizes are available: Frame B ( mm) for motors with ratings up to 2A and Frame D ( mm) covers motor ratings up to 6A. Application Description The XTPB and MMPs can be used in the following applications. Motor Protective Circuit Breaker In many countries outside of the United States and Canada, especially Europe, the MMPs are tested and classified as thermal magnetic circuit breakers for use in motor branch circuits. This can be an important consideration for all companies who export their equipment and machines internationally. Both the XTPB and conform to IEC/EN 607 and have the CE Mark. The XTPB and MMPs are UL Listed under UL 8 as. They provide an economical solution for applications requiring simple manual starting and stopping of motors. When used as an MMP, they are typically installed in an enclosure. Many enclosures are offered as accessories for the MMPs. Separate short-circuit protective devices, such as circuit breakers or fuses, are wired ahead of the MMPs. The short-circuit protective device should be sized per the NEC code and should not exceed 00% of the maximum dial setting of the MMP. Group Motor Installations A Group Motor Installation can be defined as more than one motor circuit protected by a single set of fuses or circuit breaker on a motor branch circuit. This eliminates the need for individual fuses or circuit breakers for each motor circuit. Substantial component cost savings, panel space savings and reduced wiring installation time can be achieved in Group Motor Installations. The MMPs are tested and listed for group installation. If remote operation is required, a magnetic contactor can be wired in series with the MMP. See Figure 8. Article 0. of the National Electric Code contains the rules and requirements for Group Motor Installations. Refer to Application Note AP000E for NEC requirement for group motor installation. To Supply Disconnect Fuses Or Circuit Breaker Manual Motor Protector Magnetic Contactor (Used for Remote Control) Motors Figure 8. Group Motor Installation NEC 0- See Application Note AP000E. Protection in Different Controller Types A UL 8 Type E Self-protected Manual Combination Starter/Motor Controller consists of a single device having integral short circuit protection, a main set of contacts, motor overload protection, and may also include a UL listed Line Side Adapter (see Figure ). This type of controller is a legitimate short circuit protective device and disconnect means for the downstream motor. It does require an upstream feeder short circuit protective device, but does not require a dedicated branch circuit protection or a disconnect means. A UL 8 Type E rating means that the unit clears a fault and does not experience any welding of the power poles. A UL 8 Type E self-protected manual combination starter will remain fully functional should a short circuit within its ratings occur. A UL 8 Type F Self-protected Combination Motor Controller consists of a UL 8 Listed Type E Self-protected Manual Combination Starter/Motor Controller, a UL Listed Contactor, and possibly a UL Listed. While the Type E self-protected manual motor controller of this combination motor controller device is a legitimate short circuit protective device and disconnect means for the downstream motor, the contactor is not self-protected. E.g. XTCE007 XTCE06. In addition, as a complete assembly or modular components, the device should have Type 2 Coordination certification. Type 2 Coordination means the Starter or the Controller must exhibit little or no damage following a major short circuit fault and should be able to be returned to proper service without replacing any parts. Component in a Combination Motor Controller The XTPB and MMPs can also be wired in series with a magnetic contactor to complete the assembly of a remotely operated, combination motor controller. CA00700E

May 07 Product Family Overview Features ON/OFF Rotary Handle with Lockout Provision Visible Trip Indication Class Overload Protection Phase Loss Sensitivity Ambient Temperature Compensation to IEC/EN 607, VDE 0660 Fixed Short Circuit Trip times maximum setting of overload dial Type 2 Coordination per IEC 7 Identification Markers Standard on Starter Faceplate Motor Applications from 0.A to 6A Built-in heater and magnetic trip elements to protect the motor Adjustment dial for setting motor DIN Rail Mount Terminal Types Available: Screw terminals Screw (line) and Spring Cage (load) terminals Spring Cage terminals Accessories include: Front and Side Auxiliary Contacts Trip Indicating Contacts Tamperproof Cover for OLR Dial Undervoltage Release Shunt Trip Thru-the-Door Operators Enclosures -Phase Line Side Connecting Links Group Installation Using the in-panel Main SCPD. (LSA) Not required Figure. s When to Use Them Note: s are not required for non-us applications. Most countries outside of the US classify the MMP as a thermal magnetic circuit breaker. Standards and Certifications UL Listed File No. E28 UL 8 Group Motor and Type E Compliant IEC/EN 607 CSA File LR, Class 2-0 DIN VDE 0660 Part 0, Part and Part 2 CCC Note: For Type 2 Coordination of MMCs, see Tables 27 through 2 on Pages and 0. Self-Protected Manual Combination Starters UL 8 Type E Self-Protected Manual Combination Starter Only Upstream Feeder SCPD required no dedicated in-panel Main SCPD for MMP. MMP BC (LSA) Required Types (Configurations) D MMP DC Motor Protective Device with Thermal and Magnetic Trip XTPB Pushbutton Actuated Manual Motor Protector up to 2A Rotary Actuated Manual Motor Protector up to 6A For the Protection of Transformers with a high inrush current: XTPT Manual Transformer Protector up to 2A not UL Approved Motor Protective Device without Overload Function: XTPM Motor Protective Circuit Breaker up to 2A not UL Approved CA00700E

May 07 Selection XTPB, XTPM and XTPT Selection Table 77. XT ing System X T P R 0 2 B C Designation XT = Type PB = Manual Motor Protector Pushbutton PR = Manual Motor Protector Rotary PM = Manual Motor Protector Magnetic Only PT = Manual Transformer Protector (High Mag.) B Frame P6 = 0.6A P2 = 0.2A P0 = 0.0A P6 = 0.6A 00 = A P6 =.6A 2P = 2.A 00 = A D Frame 06 = 6A 02 = 2A 02 = 2A 00 = 0A Trip Class C = Class Blank = Magnetic only (No thermal trip) Frame Size B = mm D = mm Current Ratings 6P = 6.A 0 = A 02 = 2A 06 = 6A 0 = A 02 = 2A 02 = 2A 0 = A 08 = 8A 06 = 6A CA00700E

Product Selection May 07 Table 80. Manual Self-Protected Motor Starters North American Ratings, UL 8 Type E Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted Current I u (Amps) Adjustment Range / Overload Release I r (Amps) Short Circuit Release I rm (Amps) Maximum Motor Ratings Rated Short-Circuit Breaking Capacity (ka) Maximum hp Rating P (hp) V 80/ -Phase 277V 0V V 80V/ 277V 600V/ 27V 600/ 7V Line Side Adapter Manual Motor Protector Screw Terminals Frame B 0.6 0.2 0. 0.6.6 2. 6. 2 6 2 2 Frame D 6 2 2 0 0. 0.6 0.6 0.2 0.2 0. 0. 0.6 0.6.6.6 2. 2. 6. 6. 8 2 6 6 2 2 2 6 6 2 2 2 2 0..6 8.8 6 88 0 68 280 8 8 /2 -/2 /2 -/2 /2 / 2 2 2 0 /2 -/2 0 2 0 0 Select by full load amperes. Maximum Motor Ratings (kw, hp) are for reference only. In this range, calculate motor rating according to rated current. Specified values to NEC Table 0.2. UL 8 Type E starters are assembled from a standard and a special incoming terminal ( or D). 2 2 2 8 8 Notes: A UL 8 Type E Self-Protected Manual Combination Starter () consists of a Manual Motor Protector () and a UL Listed (e.g. ). The Type E Self-Protected Manual Combination Starter alone is a legitimate short-circuit protective device and disconnect means for the downstream motor, while the contactor has been added to provide remote operation of the motor circuit. 2 2 2 8 8 D D D D 0. 0. 0. 0. P6BC P2BC P0BC P6BC 00BC P6BC 2PBC 00BC 6PBC 0BC 02BC 06BC 0BC 02BC 02BC 06DC 02DC 02DC 00DC.00.00.00 60.00 60.00 60.00 60.00 60.00 60.00 60.00 7.00 7.00.00.00 2.00 07.00 07.00 07.00.00 Accessories........................ Page 7 Technical Data..................... Page Discount Symbol.................... CD7 CA00700E