Buffer Charging Systems

Similar documents
MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

Emergency lighting units EM powerled

GENERALITIES TECHNICAL FEATURES

Power Supply EL

Contents. Impressive technology lithium-ion batteries. 596 Cordless Working Overview Bosch Accessories for Power Tools 09/10

Battery Management System (BMS) Installation guide and manual

Operating Instructions Electronic transformers for lowvoltage halogen lamps

UPS Multi Sentry 10-20kVA

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

Power Supply EL

Two temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser

GEPA. ARG-24 Series Battery Charger & Battery Group. User Guide

Emergency lighting units EM converterled

SECTION DC POWER SUPPLY/BATTERY CHARGER

Connecting other lithium systems to Multis and Quattros

ADDITIONAL EMERGENCY POWER SUPPLY DEVICES

Super Brain 969 Pro AC/DC Delta Peak Charger with Dual Output and Discharge Function Instruction Manual Model Rectifier Corporation

Super Brain 977. AC/DC Charger with Dual Output and Discharge Function. User s Manual. Model Rectifier Corporation

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Technical Manual Electrical Power Supply System T4002

Emergency lighting units EM converterled

Symptom Corrective Action. Wrong polarity of cell, block, row of battery. Interruption at connector. Interruption due to empty cell.

UP100AC INSTRUCTION MANUAL

CONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 2 SEC 1 - SPECIFICATIONS... 3 SEC 2 - DESCRIPTION... 5 SEC 3 - OPERATING INSTRUCTIONS...

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

- 1 - Tel.: Fax: Battery charging units BLG2024 and BLG3524

AWZ 110. AWZ 13,8V/1A/7Ah/LM

User Manual Rittal PMC UPS 6kVA

TECHNICAL DATA SHEET LAD/CYCLER16KW

Emergency lighting units EM powerled

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Power Conversion Systems. SCHAEFER International. Switchmode Power Supplies, Chargers & Inverters. Thyristor-controlled Power Supplies & Chargers

Emergency lighting units EM converterled

Power Electronics. Motor brake relay GA 9031 ministop

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

Softstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

AUTOMATIKLADER AL 12/10 AL 12/15 AL 24/8

EPS/ELA-Series User Manual EPS/ELA 250W

Emergency lighting units EM converterled

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Uninterruptible power supplies (UPS)

DC POWER SUPPLY SYSTEMS

HERMES power supply - short description -

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

c-go 24V/6A 24V/8A 24V/12A

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Power consumption In operation At rest For wire sizing

All In one uninterruptible power supply solutions

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

BK10 10 CHANNELS BANK CHARGER For 12V lead-acid batteries

Emergency lighting units EM powerled

STEPPER-BLOCKplus. Manual. Version: 2.0 As of: 06/2002 Author: Edmund Burger &RPSDFW6WHSSHU'ULYHU IRU3KDVH6WHSSLQJ0RWRUV. Main. Status-LED.

Technical Specification SENTINEL PRO

DC-DC STEP DOWN CONVERTER CV 24/12V - 15 A Pro

Solar Controller MPP 150 Duo Digital No Charging Capacity 12 V / 11.5 A, Solar Power up to 150 Wp

Power Electronics. POWERSWITCH Semiconductor Relay / - Contactor With Load Circuit Monitoring PH 9270

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

SINAMICS GM150 IGCT version

Operating manual UPS - System

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

Emergency lighting units PC COMBO

B How much voltage does a standard automobile battery usually supply?

Emergency lighting units PC COMBO

Owner s Manual. DC-DC Step Down Converter

Ultra Sine Inverter (US) Generation 4 (G4) User Guide


The use of batteries in hazardous areas. 1. Type of batteries and technical evolution. March 2018

Emergency lighting units EM LED Light Engines

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Portable Lamps Series HS6145, HSL145

AUTOMATIKLADER AL 12/30 AL 12/45 AL 12/60 AL 24/30 AL 24/60. Operating Instructions AL

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

AUTOMATIC BATTERY CHARGER WITH CONSTANT VOLTAGE AND CURRENT

OPERATING INSTRUCTIONS

IEC Low Voltage General Purpose Protection

Battery Charger XT EXTENDED. For lead-acid batteries. User Manual and Guide to professional charging of starter and deep cycle batteries.

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

SCC-MPPT Solar Charge Controller

SERVICES INDUSTRIELS SAVARIA INC. OWNER S MANUAL BATTERY OPERATED B.07 G

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

POWERTRONIX QUASAR 5-40 KVA

operation instruction

Power Electronics. MINISTOP Motor Brake Relay BA 9034N

ARI-PACO Electric thrust actuator

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

QPET, QPETXU Battery Chargers

Transcription:

Buffer Charging Systems for lead or NiCd-accumulators step down switched with I-U-I characteristic regulation series PLG Performance data... charging currents 2,5; 5; 10; 20 A nominal output voltage 24 V DC; max. 32 V adjustable over-current-, short protection, deep discharging- and overvoltage protection charging supervision with indicator LED s and potential free alarm contact mains transformer acc. to EN 60742 less power loss by switching regulator The charger for 24 V DC battery back up systems.

Technical data: series PLG 2,5 PLG 2,5 PLG 5 PLG 5 Pb NiCd Pb NiCd for accu version lead-accu NiCd-accu lead-accu NiCd-accu voltage 230 V +10-15% 50/60 Hz nominal output voltage 24 V = upper charging current 2,5 A 2,5 A 5 A 5 A lower charging current 0,1 x I o 0,05 x I o 0,1 x I o 0,05 x I o upper charging voltage 27,2 V 30,5 V 27,2 V 30,5 V lower charging voltage 26,5 V 28,5 V 26,5 V 28,5 V deep discharging voltage 20 V Other adjustment on request Mechanical data: mounting position vertically weight 1,7 kg 1,7 kg 2,7 kg 2,7 kg dimensions B - 140 L - 127 H - 150 b - 128 l - 112 6,5 operating temperature - 20 C... +60 C without condensation storage temperature -20 C... +70 C without condensation isolation test 4 kv; air- and creeping distance acc. onto VDE 0110 group C Random information: Paralleling of several modules for power extending with same characteristic adjustment possible.

mains voltage see techn. data Technical data: series PLG 10 PLG 10 PLG 20 PLG 20 Pb NiCd Pb NiCd for accu version lead-accu NiCd-accu lead-accu NiCd-accu voltage 230, 400 460 V 50/60 Hz 3 x 220, 400, 460 V 50/60 Hz nominal output voltage 24 V = upper charging current 10 A 10 A 20 A 20 A lower charging current 0,1 x I o 0,05 x I o 0,1 x I o 0,05 x I o upper charging voltage 27,2 V 30,5 V 27,2 V 30,5 V lower charging voltage 26,5 V 28,5 V 26,5 V 28,5 V deep discharging voltage 20 V Other adjustment on request Temperature sensor: Sensor for reducing the charging voltage depending on accu-temperature available. In case of NiCd-accu the sensor must be connected. Mechanical data: mounting position vertically weight 9,5 kg 9,5 kg 12 kg 12 kg dimensions B - 180 L - 200 H - 180 B - 225 L - 200 H - 180 b - 165 l - 145 8 b - 185 l - 145 8 operating temperature - 20 C... +60 C without condensation (PLG 20 +45 C) storage temperature -20 C... +70 C without condensation isolation test 4 kv; air- and creeping distance acc. onto VDE 0110 group C Random information: Paralleling of several modules for power extending with same characteristic adjustment possible.

Charging procedure: At the beginning the charge is starting with constant current I o until reaching a pre adjusted lower voltage U u. Then the charging goes on with reduced current I u ( 0,1 x I o ) until reaching a pre adjusted upper charge limit voltage U o. Here the charge will be stopped, otherwise the cells will blow gas or explode. charging voltage- and current versus time Charging condition indication: The charging condition will be indicated by three different coloured LED s. When the green LED is on, so the area U u (in diagram) is exceeded, the maximum accu-capacity is reached. When the yellow LED is on, the system is lower from U u in full charging operation. Only a part of the capacity can be used. When instead of them the yellow and red LED s are lit up, the lower discharging threshold is fall below (factory adjust 20 V DC). No capacity may be used. When only the red LED is on, there is given an overload or short. When reaching the lower discharging threshold there is given an alarm by a potential free relay-change over contact. Series of modules and chose: The systems will be adjusted in the factory on Pb for lead accu or NiCd for nickel cadmium accu. Other adjustments on request. The capacity of the connected accus may be maximal the 10-th of the charging current (for example by 2,5 A = 25 Ah). The conducting cables to the accus should be as short as possible and have a large cross section, to exclude instabilities. The systems PLG 10 and 20 and all NiCd-versions have furthermore a terminal for a temperature sensor, to reduce the charging voltage depending on accu-temperature. The sensor is easily fit to the housing of the less ventilated accu. The charging limit voltage herewith is reduced by 5 % when reaching 50 C. The life time of the accu herewith is extend several times.

Important instructions: To get a trouble free operation of the buffer charging system in combination with the connected accus, please note the following items: The factory adjusted charging characteristic with voltage- and current shape gives a max. capacity duty by lead- and nickel cadmium accus with a nominal voltage of 24 V DC. Sometimes the manufacturer of the accus may prescribe other values. Please note those values and tell them expressly when ordering. Especially the max. charging current may be insufficiently high for accus with less capacity! The charging condition of accus must be exactly the same when connected in series and furthermore the capacity of all accus must be the same. For example the combination of an elder or damaged accu and a new one is strictly forbidden. Furthermore the service instructions of the accu manufacturer must by noted. A change of charging characteristic only may be performed in factory. Warranty void if potentiometers are faulty adjusted. Conditioned on technical alternatives. EES Elektra Elektronik GmbH & Co Störcontroller KG Hummelbühl 7-9 D-71522 Backnang/Germany P.O.Box 12 40 D-71502 Backnang Phone: ++49.7191/182-0 Telefax: ++49.7191/182-200 e-mail: info@ees-online.de Internet: www.ees-online.de