Model AERO-24. Model ADHO24-4. Model AD24-2

7-ASC / 8-ASC / 9-ASC

Owner s Manual. Installation, Operation & Maintenance. Read and Follow All Safety Instructions. Save These Instructions. Model TM36-2.

Owner s Manual. Installation, Operation & Maintenance. Read and Follow All Safety Instructions. Save These Instructions. Model TM36-2.

UV-AIRE AIR PURIFYING SYSTEM

EXPERIENCE THE NEW IAQ REFRESH YOUR AIR

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

WARNING Risk of property damage, injury, or death.

PUREAIR AIR PURIFICATION SYSTEM PHOTOCATALYTIC OXIDATION (PCO) TECHNOLOGY

INSTALLATION INSTRUCTIONS

Safety, Installation and Service Manual Models 1952, 1953 & 1972

21", 33", 45", & 61" Installation & Operation Manual

Tube Base Arc Voltage¹ UV output¹ Rated¹ Diam. Config. BF - BF Length Power¹ Current Hi 254nm Life mm mm mm W ma V µw/cm² W hrs.

Instruction Manual. UVC AUTOMATIC HEADPHONE SANITIZER Portable Automatic Sanitizer. Never-Ending Learning Innovation

PORTABLE 2 UV CURING SYSTEM OPERATING INSTRUCTIONS

TECHNICAL INFORMATION Puissant 30-Watt Shortwave UV Light Sources Catalog Nos. SKSUV30, SKSUV40

Portable Sanitizing Wand. Model: VH03. The CleanWave Portable Sanitizing Wand kills up to 99.9% of germs and odorcausing. surfaces.

INSTALLATION AND USER INSTRUCTIONS

UV Disinfection Systems Spektron Series. Main applications: Drinking water, Industrial process water for food and beverages

Altman Stage Lighting Safety Instructions & Warnings UV-250 Blacklight Floodflight

COILCARE PM. Installation Instructions and Operating Manual. CoilCare Series BioZone Scientific International, Inc.

Installation Instructions

Installation Instructions

HARDWARE KIT INSTALLATION GLOVES

Multi-Vapor Metal Halide Lamps

Advanced PCO System. Installation Instructions & Consumer Information. Section I. Important Installer Information WARNINGS

FOODSAFE IL INSTALLATION MANUAL

BIO-FIGHTER Triad FlexMount 1S and 2S Ultraviolet Light Systems

HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION. Exflow 28 Technical Specification. Page 1 of 7

VH03 SAVE THESE INSTRUCTIONS

Ultraviolet Lamps. Worldwide Suppliers of Specialty Lamps. Creating True Value and True Partnership

Q-Series Ultraviolet Lamps OPERATOR S MANUAL

ULTRAVIOLET LAMPS. PL Series UV Hand Lamps. Compact UV Lamps. Handheld UV Lamps

User s Guide. Please Read Before Installing & Using this Equipment

Germipak UV Cell Lamps

OPK-300N OPTIMAX Multi-Lite

Ultraviolet Systems RXIU-A02A, RXIU-A03A TREATMENT SYSTEMS

Hydrosafe - Model HSFS

BIO-FIGHTER 4Xtreme 21", 33", 45" Ultraviolet Light Systems

CRYSTAL-AIRE. concealed commercial air cleaners

OPERATIONS AND MAINTENANCE MANUAL EcoStream Models ECS60R / ECS100R / ECS150R

PROTECTOR FIBERGLASS ENCLOSURES

Protector Glove Boxes.

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

Supporting the needs for investigating High Energy Pulsed Light applications

PCR Laminar Flow Cabinets

UV100A Ultraviolet Systems UV100A1000 AND UV100A1018 AIR TREATMENT SYSTEMS UV100A1059 AND UV100A2008 SURFACE TREATMENT SYSTEMS

Installer s Manual. PCO/UV N-Duct Model

The sustainable choice. Optanium high-efficiency ballasts for today s T8 lighting needs

2. Description of Standard NUV Lightsource (350nm-450nm) 3 3. Description of Deep UV (220nm-280nm) and Mid UV (280nm-310nm) Lightsource Systems 3

Since It s all we do ULTRAVIOLET CURING SYSTEMS FROM THE LEADER IN U.V. TECHNOLOGY.

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

1000W High Intensity LED Crane Light - 110,000 Lumens V AC - Stainless Steel Bracket

150W Explosion Proof LED Portable Suspended Light - J-Hook Mount - 17,500 Lumens - C1D2 / C2D1

Energy efficient low voltage dichroic mirror halogen reflector lamps

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

PHOTO-CATALYTIC AIR PURIFIER SYSTEMS

ULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE

Series 577. Vertical Flow Softwall Portable Cleanroom. Series 577 Vertical Flow Softwall Portable Cleanroom

VERSYS Architectural Recessed T5 Fluorescent

2008 PCP COMPOUND APPLICATIONS GUIDE

Purifier Logic Class II Biosafety Cabinets FEATURES & BENEFITS

OWNER S MANUAL C O M M E R C I A L I N D O O R A I R Q U A L I T Y S O L U T I O N S. Total High Efficiency Particulate & Gaseous Filtration System

Installation Instructions

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

LyteLaunch Dry - Wet and DMX Models. Operation Manual

As ept i c I s olator s

MAR SERIES Fluorescent Lighting for Hazardous Locations

ELECTROSTATIC SPRAYING SYSTEMS PX200ES CORDLESS ELECTROSTATIC SPRAYER.

FLUORESCENT INDUCTION

HRC06 OWNER S MANUAL HYDROXYL ROOM CURTAIN

Biological Safety Cabinet

Owner s Manual. Installation, Operation & Maintenance Read and Follow All Safety Instructions. Save These Instructions. Ballast 230v 50/60Hz

Lighting Tables for Existing/Base Equipment 4/15/2011

Germicidal applications can be used for all three states of matter: gases, liquids and solids.

Alter QHE Lighting Systems

C1D1 Explosion Proof 25 Watt High Bay LED Light Fixture - Paint Spray Booth Approved - 2,167 Lumens

HOW IS LIGHT PRODUCED

Introducing Zep MicroSolve TM. Now Microorganisms Have No Place to Hide

156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning

Powered Air Purifying Respirator (PAPR) For Departments that Store, Supply and Maintain PAPR Units

PRECISE. Glove Boxes

is with a variety of standard dimensions. Also our units can be custom engineered to any size.

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

CF60 General Information

OmniAire Portable Air Cleaner OA1200PAC

1200 Portable Air Scrubber Model PRED1200UV INSTRUCTION MANUAL

Ultraviolet Sterilization System Installation Instructions & Owner s Manual

FC12T9CW 32W T9 12" Cir-C-Line 60 Cri Cool White Fluor

OFK-300A OPTIMAX Multi-Lite

Class I Div 2 LED Pivoting Light - 4 foot 2 lamp - 2nd Gen LED T series Style - Back Mount Swivel

ConstantColor CMH Supermini

1000 Watt High Intensity LED Light - 110,000 Lumens V AC - High Mast / Stadium Lighting

LightWave Lighting Technology

DEPAUL UNIVERSITY. Fume Hoods Manual. Environmental Health & Safety. April 2017

RELIABILITY THROUGH TECHNOLOGY

PRODUCT CATALOG CLASS II BIOLOGICAL SAFETY CABINET.

Lamps CERAMIC METAL HALIDE

Luzchem Solar Simulator SolSim2 Updated September 2018

Transcription:

GERMICIDAL ULTRAVIOLET ROOM AIR SANITIZER Since 1963, Atlantic Ultraviolet Corporation has pioneered the discovery and development of beneficial uses of ultraviolet energy. Over the years, these efforts have led to the development of valuable, cost effective and environmentally sound techniques and products now known and utilized throughout the world. Ultraviolet is a unique and rapid method of disinfection utilizing germicidal ultraviolet lamps that produce short-wave radiation that is lethal to bacteria, virus and other microorganisms. An ever growing range of industries and consumer applications have found ultraviolet to be the ideal solution for their air treatment needs. Atlantic Ultraviolet equipment and systems are manufactured in the USA. ADVANTAGES OF THE SANITAIRE SYSTEM EFFECTIVE - air is drawn into the chamber and can be sized to meet room air changes required ECONOMICAL - equipment cost is generally less than other alternatives SAFE - virtually no risk of accidental ultraviolet exposure of occupants in treated area and no chemicals to contend with EASY - operation is simple and straightforward, with little or no installation required AUTOMATIC - continuous use - little operator attention required VERSATILE - most units are relatively portable and can be applied to different areas as needed LOW MAINTENANCE - annual lamp replacement and periodic filter cleaning is all that is required 2

PRINCIPLE GERMICIDAL OF ULTRAVIO- OPERATION 1 Air is drawn into unit through washable electrostatic particulate filters (except Model RSM2680 which utilizes disposable filters). 2 Air is forced into ultraviolet exposure chamber where it is irradiated by germicidal ultraviolet light (lamp quantity varies per model). 3 Observation port provides positive indication of germicidal lamp operation. 4 Purified air leaves exposure chamber through the louvered exhaust panel (which restricts ultraviolet radiation from passing into the room). USES AND APPLICATIONS SANITAIRE Room Air Sanitizers are germicidal ultraviolet fixtures that effectively destroy airborne microbes including bacteria, mold and virus in enclosed spaces and are available in a number of different configurations to adapt to any setting. SANITAIRE Room Air Sanitizers utilize STER-L-RAY TM germicidal lamps which are completely enclosed within a stainless steel exposure chamber and are safe for use in every application. SANITAIRE Room Air Sanitizers may be mounted into the ceiling, on a wall or are available for portable or mobile use. SANITAIRE Room Air Sanitizers are utilized to protect personnel, clients and patients from infection due to airborne microbes, particularly in crowded or poorly ventilated areas, and in situations where the risk of cross infection is high. SANITAIRE Room Air Sanitizers are the solution in healthcare facilities where communicable respiratory diseases are present and for air disinfection in offices, food processing facilities, pharmaceutical manufacturing, dairy plants, bakeries, methadone clinics, clean rooms, homeless shelters, prisons and jails. SANITAIRE Room Air Sanitizers are available to disinfect air in large conference rooms, auditoriums, waiting areas, gymnasiums and ballrooms. 3

ROOM AIR SANITIZER STER-L-RAY TM GERMICIDAL LAMP DATA Lamp No. Model Lamp Lamp Length Power 1 Ultraviolet Output 2 Rated Average (Quantity) No. Length (including lampholders) Consumption (per lamp) Effective Life 05-1348 (1) RS72 21-7/8" (556 mm) 24" 25 Watts 8.5 Watts 10,000 Hours (2) RS140 05-1352 (4) RS435 27-7/8" (708 mm) 30" 32 Watts 11.2 Watts 10,000 Hours (4) RSA760 (4) RSCS280 05-1334 (12) RSM2680 45-7/8" (1165 mm) 48" 50 Watts 19.3 Watts 10,000 Hours 1 Wattage is lamp watts only and does not include ballast loss. 2 Ultraviolet output at 254 nanometers at 100 hours and 80 degrees Fahrenheit (approximate). STER-L-RAY TM germicidal lamps are shortwave, low pressure mercury vapor discharge tubes that produce ultraviolet wavelengths lethal to microorganisms. We maintain a complete stocking inventory of all germicidal ultraviolet replacement lamps. Call for our STER-L-RAY TM Germicidal Lamp Catalog. STER-L-RAY germicidal lamps are manufactured by the Atlantic Ultraviolet Corporation. STER-L-RAY and the STER-L-RAY logo are trademarks of the Atlantic Ultraviolet Corporation. CAUTION: Overexposure to direct or reflected germicidal ultraviolet rays will cause painful eye irritation and reddening of the skin. Personnel subject to such exposure must wear suitable face shield, gloves and protective clothing. OPERATING CHARACTERISTICS Relative Spectral Energy Distribution (Typical) Germicidal Effectiveness As Related to Wavelength INTENSITY 100 80 60 40 20 0 200nm 300nm 400nm 500nm 600nm WAVELENGTH (NANOMETERS) RELATIVE EFFECTIVENESS 100 80 60 40 20 0 200nm 225nm 250nm 275nm 300nm WAVELENGTH (NANOMETERS) Approximately 95% of the ultraviolet energy emitted from STER-L-RAY TM germicidal lamps is at the mercury resonance line of 254 nanometers, the region of germicidal effectiveness most destructive to bacteria, mold and virus. 4

AIR BORNE INFECTIOUS ORGANISMS ORGANISM ALTERNATE NAME TYPE DISEASE DOSE* Corynebacterium diphtheriae C. diphtheriae Bacteria Diptheria 6,500 Legionella pneumophila L. pneumophila Bacteria Legionnaire's Disease 2,700 Mycobacterium tuberculosis M. tuberculosis Bacteria Tuberculosis (TB) 10,000 Pseudomonas aeruginosa P. aeruginosa Bacteria 3,900 Serratia Marcescens S. marcescens Bacteria 6,160 Staphlylococcus aureus S. aureus Bacteria 6,600 Staphlylococcus epidermidis S. epidermidis Bacteria 5,800 Adeno Virus Type III Virus 4,500 Coxsackie A2 Virus 6,300 Influenza Virus Flu 3,400 * Nominal Ultraviolet dosage (µwsec/cm2) necessary to inactivate better than 99% of specific microorganism. Consult factory for more complete listing. SPECIFICATIONS FOR STANDARD MODELS Nominal 1 Max. Room Size Max. Room Size Max. Treatment Unit Capacity Dimensions Electrical * 2 Treated @ 3 Room Treated @ 6 Room Capacity Model (cubic feet per minute) Length Width Height Requirement Air Changes/Hour Air Changes/Hour (cubic feet per hour) RS72 54 34-1 /2" 7-3 /4" 7-3 /4" 1.30 amp 1,080 Cubic Ft. 540 Cubic Ft. 3240 RS140 105 34-1 /2" 7-3 /4" 7-3 /4" 2.90 amp 2,100 Cubic Ft. 1,050 Cubic Ft. 6300 RS435 326 47-5 /16" 14" 12" 4.93 amp 6,525 Cubic Ft. 3,263 Cubic Ft. 19,575 RSA760 380 59" 14" 12" 5.96 amp 7,600 Cubic Ft. 3,800 Cubic Ft. 22,800 RSCS280 210 46-5 /8" 22-1 /8" 9-7 /16" 4.26 amp 4,200 Cubic Ft. 2,100 Cubic Ft. 12,600 RSM2680 2000 32" 30" 78-3 /4" 11.00 amp 40,000 Cubic Ft. 20,000 Cubic Ft. 120,000 1 Unit capacity incorporates an estimated allowance for airflow friction loss across filter and unit. 2 Information listed refers to 120 Volt 60 Hz units. Contact factory for specifics on other voltages. * Consult factory with specific power requirements. 5

ROOM AIR SANITIZER SPECIAL FEATURES OF THE RS72, RS140, RS435 or RSA760 WALL OR CEILING MOUNT GERMICIDAL LAMPS Genuine STER-L-RAY TM Ultraviolet Germicidal Lamps provide the utmost in quality, sustained high output and long life. LAMPHOLDERS Steadfast TM Lampholders are spring loaded telescopic type that facilitate convenient, easy lamp change that is quick and hassle-free. INTERLOCK SAFETY SWITCH The interlock safety switch is a standard feature that disconnects power to the unit when the access panel is removed for lamp or filter replacement. POLISHED REFLECTOR Interior chamber is polished providing a highly reflective surface to maximize ultraviolet intensity within the chamber. STANDARD WALL MOUNT KIT Consists of (2) pre-drilled stainless steel brackets. Brackets enable unit to be mounted to wall in either the vertical or horizontal position. LOUVERED EXHAUST PANEL Protects the room s occupants from ultraviolet exposure by restricting ultraviolet radiation from passing into the room. OBSERVATION PORT(S) A visible glow through the clear sight glass provides positive indication of germicidal lamp operation. STAINLESS STEEL CONSTRUCTION The chamber is Type 304 stainless steel for an attractive finish, unparalleled strength and durability. PARTICULATE FILTER Washable Electrostatic Filter Absolute Filter - HEPA Type (Model RSA760) OPTIONAL ACCESSORIES Disposable Filters Optional Wall Mount Kit Ceiling Mount Kit Integral Elapsed Time Indicator * Integral Key Lock Switch * SENTINEL TM Lamp Operation Indicator * Item must be ordered at same time as Room Air Sanitizer Unit (installed at factory). SPECIAL FEATURES OF THE RSCS280 CEILING MOUNT GERMICIDAL LAMPS Genuine STER-L-RAY TM Ultraviolet Germicidal Lamps provide the utmost in quality, sustained high output and long life. LAMPHOLDERS Steadfast TM Lampholders are spring loaded telescopic type that facilitate convenient, easy lamp change that is quick and hassle-free. INTERLOCK SAFETYSWITCH The interlock safety switch is a standard feature that disconnects power to the unit when the access panel is removed for lamp or filter replacement. POLISHED REFLECTOR Interior chamber is polished providing a highly reflective surface to maximize ultraviolet intensity within the chamber. LOUVERED EXHAUST PANEL Protects the room s occupants from ultraviolet exposure by restricting ultraviolet radiation from passing into the room. LAMP OPERATION INDICATORS Provide positive indication of germicidal lamp operation. STAINLESS STEEL CONSTRUCTION The chamber is Type 304 stainless steel for an attractive finish, unparalleled strength and durability. PARTICULATE FILTER Washable Electrostatic Filter OPTIONAL ACCESSORIES Disposable Filters Integral Elapsed Time Indicator * SENTINEL TM Lamp Operation Indicator * Item must be ordered at same time as Room Air Sanitizer Unit (installed at factory). 6

SPECIAL FEATURES OF THE RSM2680 MOBILE UNIT GERMICIDAL LAMPS Genuine STER-L-RAY TM Ultraviolet Germicidal Lamps provide the utmost in quality, sustained high output and long life. LAMPHOLDERS Steadfast TM Lampholders are spring loaded telescopic type that facilitate convenient, easy lamp change that is quick and hassle-free. INTERLOCK SAFETY SWITCH The interlock safety switch is a standard feature that disconnects power to the unit when the access panel is removed for lamp or filter replacement. POLISHED REFLECTOR Interior chamber is polished providing a highly reflective surface to maximize ultraviolet intensity within the chamber. ELAPSED TIME INDICATOR Realtime, non-resettable display of accumulated operating hours. LOUVERED EXHAUST PANEL Protects the room s occupants from ultraviolet exposure by restricting ultraviolet radiation from passing into the room. LAMP OPERATION INDICATORS Provide positive indication of germicidal lamp operation. STAINLESS STEEL CONSTRUCTION The chamber is Type 304 stainless steel for an attractive finish, unparalleled strength and durability. DISPOSABLE FILTERS Inexpensive, disposable cardboard constructed filters used when frequent filter changes are necessary. DIFFERENTIAL AIR PRESSURE GAUGE Used to measure filter resistance by measuring the pressure differential between outside (the fixture) air and the pressure in the blower compartment. 3- POSITION POWER SWITCH Power to the fixture is controlled by a three position key switch. In the OFF position, no power is supplied to the blower or the germicidal lamps. In the BLOWER ONLY position, power is supplied to just the blower and no power is supplied to the germicidal lamps. In the LAMPS & BLOWER position power is supplied to both the blower and the germicidal lamps. OPTIONAL ACCESSORIES DISPOSABLE FILTERS Inexpensive, disposable cardboard frame filters for use when frequent filter changes are necessary. INTEGRAL KEY LOCK SWITCH * The Key Lock Switch will insure tamperproof operation in either on or off position. OPTIONAL WALL MOUNT KIT Consists of (2) pre-drilled stainless steel brackets. Brackets are designed to provide a more aesthetic look for the installation while allowing unit to be mounted to the wall in a horizontal position. SENTINEL TM LAMP OPERATION INDICATOR The SENTINEL TM monitors lamp operation in a remote location up to 25 feet away. CEILING MOUNT KIT Consists of (4) eye bolts used to suspend unit from ceiling. * Item must be ordered at same time as Room Air Sanitizer Unit (installed at factory). INTEGRAL ELAPSED TIME INDICATOR * The Elapsed Time Indicator is a real-time, non-resettable display of accumulated operating time. Useful for scheduling and recording maintenance and lamp replacement. 7