AND AXIAL FLOW FANS ECOFIT

Similar documents
Size and Configurations

AXIAL FANS Catalogue CN0050C01 May 2008

Unobox units with backward curved centrifugal impellers

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

MAJAX-2 GENERAL SPECIFICATION

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS

Hison Axial Flow Fans

Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction

Hison Axial Flow Fans

Short casing. Long casing (L version) Commercial premises

AC Commercial Fans Edition. ErP ready

CYLINDRICAL CASED AXIAL FLOW FANS

supplied in Form (B) configuration. Airflow over Impeller- Motor.

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Sabre Plate Mounted Sickle Fans (VSP)

TGT Series Adjustable Pitch Fans

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES

NOVENCO FAN CATALOGUE

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

Bifurcated Case Axial Fans (BIFA)

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

WINDER. Impellers with higher efficiency and less sound level

Centrifugal Fans RZR belt driven. Issue 2.5 EN August 2013

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

JM Aerofoil Multi-Stage 50 Hz

TGT Series Adjustable Pitch Fans

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

High Performance Axial Fans

Mixed Flow Roof Fans (RMH)

REVOLUTION SLCX Product Brochure

Novenco axial flow fans. ZerAx - Standard January 2010

Sabre Sickle Fan Assisted Roof Cowls (VSR)

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

Vent-Axia Sabre Sickle Roof Fans (VSR)

Mixed Flow Roof Fans (RMH)

Section 4. Axial Fans - Section 4

ASA. SINGLE INLET CENTRIFUGAL FAN with Airfoil Wheels

Industrial Mini Vent Sets

Novenco Tunnel Fans. Novax October 2007

AXIAL FANS & VANEAXIAL FANS

Square Mixed Flow Fans (MFQ)

ROOFMASTER STEF-ATEX ROOF FAN

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

Centrifugal Fans ADH belt driven. Issue 2.5 EN August 2013

BIFLOW SB CON Product Brochure

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

CENTRIFUGAL FANS. Single Width, Single Inlet WFS & WBS Series WTC TECH CO., LTD. CENTRIFUGAL FANS Single Width, Single Inlet WFS & WBS Series

NEW WINDER. Impellers with higher efficiency and less sound level

Small centrifugal fans made of plastic

Performance. Sound Levels. Impellers. Motors. Accessories

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

CGT Series Adjustable Pitch Fans

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

CGT Series Adjustable Pitch Fans

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

& 12" 96" / TABD CATALOG

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

Tube Axial Fan Page Specifications & Dimension Data Performance Data

Fixed Pitch Vane Axial Fan

Centrifugal Fans belt driven. TD_CFB-RDY_EN Issue 1.1 EN July 2013

ROOFMASTER STEF-HT ROOF FAN

HIGH TEMPERATURE TWIN SQUIF FANS

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

Axial fans. What s more, non-stock models are normally available within two weeks.

BSB SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

Max. airflow m 3 /s Diam. min. Diam. max

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Centrifugal fan with highly efficient EC drive motor

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Multifunctional 400ºC/2h and 300ºC/2h roof fans

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

AXUS HIGH TEMPERATURE AXIAL FANS

WIDE RANGE OF SMOKE EXTRACT FANS FOR HIGH TEMPERATURE APPLICATIONS.

"LCA"- long cased axial fan

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

COMPACT Series type HCFB / HCFT (Plastic impellers)

Centrifugal medium-pressure fans fitted with multi-blade

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

DUCT-M HT F400/2h. Smoke exhaust ducted axial fan APPLICATIONS TECHNICAL SPECIFICATIONS VERSIONS ACCESSORIES ON REQUEST. May 2018 Catalog N 000 Rev.

PROVEN PERFORMANCE RELIABILITY EASY INSTALLATION

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

Mancoolers Models MCY, MCB, MCP

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

CNA-CNB CNA-CNB CENTRIFUGAL FANS STANDARD TEMPERATURES AND EX

JM Aerofoil Bifurcated Fans

BPF. Centrifugal Plug Fans

Transcription:

AND AXIAL FLOW FANS with adjustable blades as standard fans, explosion proof design and smoke fans ECOFIT Rosenberg East Asia Pte Ltd 71 Ubi Crescent #08-04 Excalibur Centre Singapore 408571 Tel: +65 6846 8866 Fax: +65 6846 1129 www.rosenberg.com.sg roseasia@singnet.com.sg

General Information Warranty Guidelines The Rosenberg Group The customer is responsible for the project design, Since the company's foundation in 1981, Rosenberg selection and operation of the fans. The supplier gives Ventilation GmbH has developed into an important centre warranty for faulty products, excluding further claims, in for the heat, ventilation and air conditioning industry in accordance with valid terms and conditions of business. Europe through the development and manufacturing of speed controllable external rotor motors, fans, blowers, air Warranty will not be given in the following instances: handling units, and motor speed control devices. Our aim is for high quality production backed by our top (I) Unfitted or inappropriate usage, incorrect mounting or class service for our cilents. Thus a continous flow of inforfaulty installation by the purchaser or a third party, normal mation and good cooperation between you, dear customers, wear and tear, incorrect or negligent handling, improper and us is important to jointly achieve a continuous evolution maintenance, unsuitable operating material, unsuitable of our products and their quality. ground and chemical, electrochemical or electrical influ- Modern test chambers and equipment, as well as computer ence as long as they are not the responsibility of the controlled production handled by self-responsible working supplier. teams are part of our philosophy, as the control of high quality and environmental protection measures. (II) If the goods delivered from the manufacturer are faulty 60% of Rosenberg's total revenue is in export sales., the customer has the right to receive a replacement or Currently Rosenberg has 240 employees at the company's replacement of the faulty parts to the maximium value of headquarter in Kunzelsau and more than 1,400 worldwide. the purchase price. The manufacturer also has the right Further production facilities are located in Glaubitz(GER), to get the product repaired within a reasonable time Waldmunchen (GER), Hungary, Czech Republic, Slovakia period. The manufacturer must be informed immediately France, Italy and China. in the case of damage. (III) The obligation to replace additional faults is herewith excluded. Our general terms of business are the basis for all further agreements for example: time periods to repair or replace. The general terms of business are available on our website www.rosenberg.eu or direct from one of our sales representatives. Headquarter in Kunzelsau, Germany We reserved the right to amend the specification of these proudcts without prior notification.

Axial fans - AND Series Axial fans AND series with adjustable blades. Technical Description Impellers Axial fans with adjustable blades cover a wide capacity range due to their large variation possibilities with hub relation, number of blades and blade angle. With the airflow Rosenberg AND series, pressure increases up to 1200Pa direction and volumes up to 85,000cmh can be realized. The allowed temperatures of the conveyed mediums are from -20 0 C up to +80 0 C as a standard, following description of motor manufacturer. Special motors for higher direction of rotation temperatures are available upon request. The standard air flow direction is pressured over the The axial impellers are balanced on quality level G 6.3 motor. To reverse airflow direction, blade position must be according to DIN ISO 1940. The hubs of chilled casting rotated 180 0 and the direction of motor rotation must be aluminium are made in two parts and have removal drilling changed. for easy dismounting of the impellers. The profile blades are made of aluminium die cast. In standstill the blades angles are adjustable. If the blade angle α is adjusted after delivery, the power requirement must be checked for overload of the motor. The impeller has to be balanced after blade adjustment. The blade angle is measured on the wing tip. The number of blades is variable which expands the performance range and allows any operation. Aluminium alloy LM6M blades are use in smoke and fume extract up to 400 0 C. Rosenberg supplies glass reinforced polypropylene blades for fan diameter 560 and below for normal class F motor as a standard. The blades are injection moulded UV stabilised anti-static, black color and with the same curve profile as the aluminium blades. Temperature range from -10 0 C to +80 0 C. The chemical resistance of polyproylene make the fans suitable to use in area exposed to some diluted acids and alkali, oily and with various organics such as alcohols, ketones, The fans are suitable for vertical and horizontal installation. aromatic and chlorinated environment. The fans are designed for installation in a ventilation system and therefore supplied without protection guard as Motors a standard. Casings The casings are manufactured from mild steel with hot dipped galvanized finishing after manufactured as an anticorrossive measure and for longer life as a standard. Every casing comes with defined flange master gauge for holes to ensure an easy connection to the duct system. The centrally mounted motor is wired via a flexible weatherproof cable to an external located IP55 protected terminal box on the fan casing. The fan casing have a minimum thickness 3-phase IEC standard motors of type B3 with protection class of 3mm on fan sizes up to 1120mm and a minimum of 4.5 IP55, insulation class F in 2-, 4-, 6- or 8 pole execution are mm for larger fans. used. Pole changeable, voltage controllable, invertor motors In the long casing version, the casing, the motor and the and single phase A.C. motors or higher airflow temperatures blades are covered. In the short casing version, the motor are available upon request. Motor used comply with electrical juts out. Two stage axial fans, coupling of two long casing standard IEC 60034-30. fans are also available upon request.

Axial fans - AND Series Special Design: Optional Features Explosion Proof Reverse Direction AND axial fans are available as explosion proof type. The The standard direction of flow is Form B, where air passes maximium shaft power is limited to 15kW. The explosion through the impeller over the motor. Reverse flow, Form A proof fans are in accordance to ATEX standards with the can be provided on request ( for 3 phase motor only). The marking II2GcIIBT3X. They are suitable resulting performances in reverse direction are: for use in and for conveying in Zone 1 & 2. Volume reduced by 30%. Exe or Exd explosion proof motor, depend- Pressure reduced by 50%. ing on the application can be used. Power reduced by 25%. Anti static FRP blades with aluminium hub are used for fan diameter 315 to 560mm as a standard. Aluminium impeller with anti-spark track are used for fan diameter 630mm and above. The aluminium anti-spark track isolate the steel casing from the blades, thus preventing the possibility of a static electric spark. Anti static FRP blades with aluminium hub for 630mm diameter and above are also available. Due to the larger annular gap of explosion proof fans, a The AMCA Certified Ratings Seal does not apply to performance of reverse power loss (5% in volume flow and 15% in pressure) must direction. be taken into consideration during selection. Guide Vanes Up stream or Down stream guide vanes can be incorporated Smoke Extract to increase the fan performance. AND axial fans are suitable for smoke extract system. Only Up stream (or inlet ) guide vanes create a swirl effect in the aluminium impellers are used. Fan casings are made from the opposite direction to the impeller rotation. It enables the mild steel with hot dipped galvanized finishing as standard. following fan performance increases: Special high temperature rated for 250 0 C two hours, one Pressure 25%. time continuous run, class H insulation, IP55 motors are Volume flow 20% used. For higher temperature range, please consult our Motor kw 40%. sales representatives. Down stream (or Outlet) guide vanes act in the opposite direction to the swirl from the impeller and straighten the discharge air, enabling an improvement in pressure capacity: Pressure 20%. Volume flow 0% Motor kw 0%. The AMCA Certified Ratings Seal does not apply to performance of guide vanes. Epoxy Coating Epoxy coating on casing is available on special request. The fans are painted with protective epoxy coating paints in situations where they are exposed to chemical solvents, salt water and other corrossive atmospheric conditions. Two-Stage A contra-rotating two stage axial fan consists of two single stage oposite handed impellers rotating in oposed directions. The contra-rotating system develops approxiamately 2 to 3 times the static pressure of a single stage impeller system of the same diameter and speed. The two stage system uses 5 to 10% less power and is quieter than a single stage system producing the same work at the same diameter. The air flow can be regulated by idling one stage. A flow reduction of 35% and a power reduction of 50% is possible without losses. If necessary more stages can be added if pressure demands are higher than a two stage system can meet. The AMCA Certified Ratings Seal does not apply to performance of two stage axial fans.

Specifications Performance Curves Performance curves and technical specifications are based upon tests carried out in accordance to AMCA 210-99 standards by an independence laboratory. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type D - Ducted inlet, Ducted outlet. Performance rating do not include the effects of appurtenances (accessories). The curves are valid for air with a density of 1.2kg/m3 at a temperature of 20 0 C. The curves in this catalogue shows the increase of the static and the dynamic pressure in Pascal (Pa) as a function of the airflow in cubic metre per hour (m 3 /h). Comparatively standards are ISO 5801, BS 848 Part 1 and DIN 24163. Sound Level The sound ratings shown on the fan curves are based on tests procedures performed in accordance with AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. The values shown are for inlet Lwi A sound power levels for installation type D: Ducted inlet, Ducted outlet. The ratings include the effects of duct end correction. The A-weighted sound rating shown have been calculated as per AMCA International Standard 301. Rosenberg East Asia Pte Ltd certifies that the Axial fans - AND Series shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA certified Ratings Program. The AMCA Certified Ratings Seal applies to air and sound performance for Model AND315 to AND1250. The AMCA Certified Ratings Seal applies to the Fan Efficiency Grade for Model AND500 to AND1250. The Ratings Seal applies to sound and air performance as shown in our published catalog. Rosenberg East Asia Pte Ltd is a member of the Air Movement and Control Association International Inc. The International Authority on Air System Components.

Information on Sound Sound Level Information The sound power levels shown on the fan curves are for The sound pressure level at the inlet at 1m distance in low inlet Lwi A scale for installation type D: ducted inlet, reflexion installation can be obtained by deducting 11dB ducted outlet. Ratings include the effects of ducted end from the sound power level at the inlet side. The sound correction. pressure difference from 1m to distance a is obtained If the sound power frequency spectrum is needed, for as follows: example, the design of sound attenuators, the A- rated Lp = 10 * log (1/a ). sound power levels at particular octave band frequency L WA can be calculated by subtracting the relative sound Please note that reflections and room characteristics as level L wrel. well as natural frequencies influence the size of the sound L WA = L wi - L wrel pressure level differently. The acoustic values of the inlet side can be used for the outlet side of the fans as well. Sound power frequency spectrum calculated with this Lwrel are not licensed by AMCA. Relative Sound Power Frequency Spectrum ( L wrel ) [ db ] Fan Diameter 63 125 250 500 1000 2000 4000 8000 (mm) Hz Hz Hz Hz Hz Hz Hz Hz 315-16 -10-8 -6-6 -9-13 -21 400-21 -12-7 -6-8 -11-16 -23 500-20 -13-9 -6-6 -7-11 -19 560-21 -14-8 -6-6 -8-13 -20 630-23 -16-9 -6-5 -7-12 -19 710-27 -16-8 -7-6 -8-13 -20 800-29 -19-9 -6-5 -8-13 -20 900-31 -19-8 -6-5 -9-14 -20 1000-20 -9-8 -6-7 -11-15 -22 1120-26 -14-8 -5-6 -11-15 -19 1250-25 -15-9 -5-5 -9-14 -20 db A-Weighting Correction Frequency (Hz) 63 125 250 500 1000 2000 4000 8000 A-Weighting -25.5-15.5-8.5-3.0 0.0 1.0 1.0-1.0 Correction For Distance Decibel Addition If the levels to be added differ by db 0 or 1 2 or 3 4 to 9 10 or more the total is equal to the larger level plus db 3 2 1 0 Summation of Sound Sources Sound of several equal sources, can be added by L Σ = L 1 + 10 * log (z) whereby : z = number of sources L 1 = sound level of a single source L Σ = resulted level

Axial fans - AND Series Product Code Identification Standard Range from 315 to 710 Larger Range from 800 to 1250 AND-Ex 630/ 14/ 250-25 AND-Ex 1000 / 6-6 / 6AL - 20 Ex-proof Ex-proof Fan diam(mm) Fan diam(mm) No. of blades No. of blades & hub size Pitch angle & hub size Pitch angle Type of blades AL- Aluminium PPG- Glass reinforce polypropylene PAGAS- Antistatic glass reinforce polyamide Fluid Flow Rules Of Operation For Fans Speed variation at constant fan size and constant density : The volume flow changes proportional to speed V 1 / V 2 = n 1 / n 2 All pressures (static, dynamic and total) change square of the speed p 1 / p 2 = ( n 1 / n 2 ) 2 = ( V 1 / V 2 ) 2 The power requirement changes cube to the speed p 1 / p 2 = ( n 1 / n 2 ) 3 = ( V 1 / V 2 ) 3 Changes in the density at constant speed ( or change of the kelvin temperature at a constant flow medium): The volume flow is not affected V = const. All pressures change proportionately to the density * p 1 / p 2 = α 1 / α 2 = T 2 / T 1 The power requirement changes proportionately to the density P 1 / P 2 = α 1 / α 2 = T 2 / T 1 * T 1 = T o + t 1 = 273.15 K + t 1 T 2 = T o + t 2 = 273.15 K + t 2 In the case of changes in the wheel diameter of geometrically similar wheels at constant speed: The volume flow changes cube to the wheel diameter V 1 / V 2 = ( D 1 / D 2 ) 3 All pressures (static, dynamic and total) change propportionately to the square of the wheel diameter p 1 / p 2 = ( D 1 / D 2 ) 2 The power requirement changes proportionately to the fifth power of the wheel diameter P 1 / P 2 = ( D 1 / D 2 ) 5

AMCA - FEG rating Fan Efficiency Grade (FEG). Certified FEGs are determined in accordance with AMCA 205-10 Energy Efficiency Classification for fans. In conjunction with AMCA 211-05 (Rev. 3/11) Certified Ratings Program, Product Rating Manual for Fan Air Performance. This classification is based on fan peak (optimum) total efficiency for a given fan speed, fan size and application category. For the purpose of energy classification, the peak efficiency can be determined at a speed not higher than the maximum design speed of the fan. The AMCA Certified Ratngs Seal applies to the Fan Efficiency Grade (FEG) for AND series Axial fan model AND 500 to AND 1250 as shown in the table below only. Fan Fan Fan Fan Fan Fan Fan Fan Model Speed Outlet Efficiency Model Speed Outlet Efficiency No. (rpm) Area (m2) Grades (FEG) No. (rpm) Area (m2) Grades (FEG) AND 500/10/150 2880 1440 1440 960 0.1963 FEG56 AND 560/14/250 960 720 720 0.2463 FEG56 AND 630/14/250 1440 1440 960 0.3117 FEG56 AND 710/14/250 960 720 720 0.3959 FEG63 AND 800/12-12/4AL 1440 1440 960 0.5052 FEG60 AND 900/12-12/5AL 960 720 720 0.6404 FEG63 AND 1000/6-6/6AL 1440 1440 960 0.7885 FEG75 AND 1120/8-8/6AL 960 720 720 0.9887 FEG71 AND 1250/8-8/6AL 1440 960 720 1.2233 FEG75 Fan Peak Total Efficiency (%) 90 80 70 60 50 40 FEG90 FEG85 FEG80 FEG75 FEG71 FEG67 FEG63 FEG60 FEG56 FEG53 FEG50 30 20 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Fan Size (mm)

Dimensions Fan Motor A B C D E F G H J K Long Short Diameter Frame Inner Outer Long Short (max) (thk) Nos. Of Holes PCD Conduit Casing Casing (Nominal) Size Diam Diam Casing Casing Holes Diam Diam Diam (kgs) (kgs) 315 63 315 395 300 180 290 2 8 10 355 20 30 26 315 71 315 395 300 180 300 2 8 10 355 20 33 29 315 80 315 395 350 180 335 2 8 10 355 20 38 32 400 63 400 480 300 220 290 3 8 12 450 20 34 30 400 71 400 480 300 220 300 3 8 12 450 20 36 33 400 80 400 480 350 220 335 3 8 12 450 20 42 36 400 90 400 480 400 220 380 3 8 12 450 20 52 44 400 100 400 480 400 220 380 3 8 12 450 20 60 52 500 71 500 600 300 220 300 3 12 12 560 20 43 38 500 80 500 600 350 220 335 3 12 12 560 20 49 42 500 90 500 600 400 220 380 3 12 12 560 20 60 50 500 100 500 600 400 250 440 3 12 12 560 20 73 65 500 112 500 600 400 250 440 3 12 12 560 25 80 72 500 132 500 600 500 250 440 3 12 12 560 25 122 109 560 71 560 660 300 220 300 3 12 12 620 20 51 46 560 80 560 660 350 220 335 3 12 12 620 20 58 49 560 90 560 660 400 220 380 3 12 12 620 20 69 57 560 100 560 660 400 250 440 3 12 12 620 20 77 67 560 112 560 660 400 250 440 3 12 12 620 25 95 79 560 132 560 660 500 300 555 3 12 12 620 25 132 119 630 71 630 730 300 250 300 3 12 12 690 20 56 52 630 80 630 730 350 250 335 3 12 12 690 20 63 56 630 90 630 730 400 250 380 3 12 12 690 20 75 64 630 100 630 730 400 250 440 3 12 12 690 20 88 77 630 112 630 730 400 250 440 3 12 12 690 25 95 84 630 132 630 730 500 300 555 3 12 12 690 25 139 125 630 160 630 730 700 400 650 4 12 12 690 32 209 187 710 80 710 810 350 250 335 3 16 12 770 20 67 58 710 90 710 810 400 250 380 3 16 12 770 20 80 67 710 100 710 810 400 250 440 3 16 12 770 20 93 80 710 112 710 810 400 250 440 3 16 12 770 25 100 87 710 132 710 810 500 300 555 3 16 12 770 25 145 129 710 160 710 810 700 400 710 4 16 12 770 32 217 192 710 180 710 810 700 500 775 4 16 12 770 38 277 260 All dimensions in millimetre (mm).

Dimensions Fan Motor A B C D E F G H J K Long Short Diameter Frame Inner Outer Long Short (max) (thk) Nos. Of Holes PCD Conduit Casing Casing (Nominal) Size Diam Diam Casing Casing Holes Diam Diam Diam (kgs) (kgs) 800 80 800 900 350 250 335 3 16 12 860 20 74 64 800 90 800 900 400 250 380 3 16 12 860 20 86 72 800 100 800 900 400 250 440 3 16 12 860 20 99 85 800 112 800 900 400 250 440 3 16 12 860 25 106 92 800 132 800 900 500 300 555 3 16 12 860 25 153 134 800 160 800 900 700 400 650 4 16 12 860 32 227 198 900 90 900 1000 400 250 380 4 16 15 970 20 96 80 900 100 900 1000 400 250 440 4 16 15 970 20 109 93 900 112 900 1000 400 250 440 4 16 15 970 25 116 100 900 132 900 1000 500 300 555 4 16 15 970 25 164 143 900 160 900 1000 700 400 710 4 16 15 970 32 240 208 900 180 900 1000 700 400 710 4 16 15 970 38 265 233 1000 100 1000 1100 400 300 440 4 16 15 1070 25 127 115 1000 112 1000 1100 400 300 455 4 16 15 1070 25 134 122 1000 132 1000 1100 500 300 570 4 16 15 1070 25 182 173 1000 160 1000 1100 700 420 725 4 16 15 1070 32 261 237 1000 180 1000 1100 700 500 775 4 16 15 1070 38 333 320 1000 200 1000 1100 800 550 840 5 16 15 1070 52 428 403 1000 225 1000 1100 1000 590 910 5 16 15 1070 52 530 481 1120 112 1120 1220 400 300 455 4 16 15 1175 25 160 145 1120 132 1120 1220 500 300 570 4 16 15 1175 25 212 182 1120 160 1120 1220 700 420 725 4 16 15 1175 32 297 255 1120 180 1120 1220 700 500 775 4 16 15 1175 38 357 327 1120 200 1120 1220 800 550 840 5 16 15 1175 52 455 417 1120 225 1120 1220 1000 590 910 5 16 15 1175 52 563 501 1120 250 1120 1220 1000 590 940 6 16 15 1175 52 667 605 1250 132 1250 1350 500 300 570 4 20 15 1320 25 249 206 1250 160 1250 1350 700 420 725 4 20 15 1320 32 346 286 1250 180 1250 1350 700 500 775 4 20 15 1320 38 406 364 1250 200 1250 1350 800 550 840 4 20 15 1320 52 511 457 1250 225 1250 1350 1000 590 910 4 20 15 1320 52 632 544 1250 250 1250 1350 1000 590 980 4 20 15 1320 52 835 747 1250 280 1250 1350 1200 700 1075 4 20 15 1320 52 1008 982 All dimensions in millimetre (mm).

Dimensions Fan Motor A B C D E F G H J K Long Short Diameter Frame Inner Outer Long Short (max) (thk) Nos. Of Holes PCD Conduit Casing Casing (Nominal) Size Diam Diam Casing Casing Holes Diam Diam Diam (kgs) (kgs) 1400 132 1400 1540 500-570 4.5 20 18 1470 25 283-1400 160 1400 1540 700-725 4.5 20 18 1470 32 387-1400 180 1400 1540 700-775 4.5 20 18 1470 38 447-1400 200 1400 1540 800-840 4.5 20 18 1470 52 554-1400 225 1400 1540 1000-910 4.5 20 18 1470 52 680-1400 250 1400 1540 1000-980 4.5 20 18 1470 52 883-1400 280 1400 1540 1200-1075 4.5 20 18 1470 52 1062-1400 315 1400 1540 1200-1075 4.5 20 18 1470 52 1242-1530 132 1530 1669 500-570 6 24 18 1610 25 297-1530 160 1530 1669 700-725 6 24 18 1610 32 405-1530 180 1530 1669 700-775 6 24 18 1610 38 465-1530 200 1530 1669 800-840 6 24 18 1610 52 574-1530 225 1530 1669 1000-910 6 24 18 1610 52 705-1530 250 1530 1669 1000-980 6 24 18 1610 52 908-1530 280 1530 1669 1200-1075 6 24 18 1610 52 1159-1530 315 1530 1669 1200-1075 6 24 18 1610 52 1339-1600 132 1600 1739 500-570 6 24 18 1680 25 358-1600 160 1600 1739 700-725 6 24 18 1680 32 485-1600 180 1600 1739 700-775 6 24 18 1680 38 545-1600 200 1600 1739 800-840 6 24 18 1680 52 664-1600 225 1600 1739 1000-910 6 24 18 1680 52 814-1600 250 1600 1739 1000-980 6 24 18 1680 52 1008-1600 280 1600 1739 1200-1075 6 24 18 1680 52 1249-1600 315 1600 1739 1200-1075 6 24 18 1680 52 1359 - All dimensions so s in millimetre e (mm).

Motor Informations Motor Poles Motor Power Full Motor Poles Motor Power Full Size Frame Load Size Frame Load Size Current Size Current (kw) (ampere) (kw) (ampere) 0.18 2 pole 63 230/1/50 1.60 0.75/0.11 2/4 poles 80 415/3/50 1.63/ 0.49 0.37 2 pole 71 230/1/50 2.70 1.5/0.12 2/4 poles 90L 415/3/50 3.17/ 1.00 0.55 2 pole 71 230/1/50 3.90 2.2/0.37 2/4 poles 100L 415/3/50 4.05/ 0.94 0.75 2 pole 80 230/1/50 5.50 3.6//0.6 2/4 poles 112M 415/3/50 6.83/ 1.92 1.1 2 pole 80 230/1/50 6.60 4/1 2/4 poles 112M 415/3/50 7.98/ 2.98 1.5 2 pole 90L 230/1/50 9.60 5.5/1.2 2/4 poles 132S 415/3/50 10.58/ 3.27 2.2 2 pole 90L 230/1/50 15.40 7.5/1.8 2/4 poles 132S 415/3/50 13.85/ 4.13 11/2.75 2/4 poles 160M 415/3/50 19.62/ 6.25 0.18 4 pole 63 230/1/50 2.10 15/3.75 2/4 poles 160L 415/3/50 25.29/ 7.48 0.37 4 pole 71 230/1/50 3.20 18.5/4.6 2/4 poles 160L 415/3/50 31.54/ 9.33 0.55 4 pole 80 230/1/50 4.20 22/5.5 2/4 poles 180L 415/3/50 46.25/ 9.4 0.75 4 pole 80 230/1/50 5.10 1.1 4 pole 90L 230/1/50 7.80 0.18/0.1 4/6 poles 80 415/3/50 0.65/ 0.5 1.5 4 pole 90L 230/1/50 9.30 0.37/0.18 4/6 poles 90S 415/3/50 1.07/ 0.74 2.2 4 pole 100L 230/1/50 12.70 0.55/0.18 4/6 poles 90L 415/3/50 1.23/ 0.82 0.75/0.28 4/6 poles 90L 415/3/50 1.63/ 1.11 0.18 6 pole 71 415/3/50 0.66 1.1/0.33 4/6 poles 100L 415/3/50 2.21/ 0.94 0.37 6 pole 80 415/3/50 1.16 1.5/0.5 4/6 poles 100L 415/3/50 3.17/ 1.6 0.55 6 pole 80 415/3/50 1.59 2.2/0.75 4/6 poles 112M 415/3/50 4.62/ 2.6 0.75 6 pole 90S 415/3/50 1.98 3/0.98 4/6 poles 112M 415/3/50 6.44/ 2.88 1.1 6 pole 90L 415/3/50 3.03 4/1.5 4/6 poles 132S 415/3/50 9.04/ 3.56 1.5 6 pole 100L 415/3/50 3.62 5.6/2.2 4/6 poles 132M 415/3/50 10.38/ 4.66 2.2 6 pole 112M 415/3/50 5.23 7.5/2.2 4/6 poles 132M 415/3/50 14.42/ 4.66 3 6 pole 132S 415/3/50 6.03 11/3.7 4/6 poles 160L 415/3/50 19.81/ 7.42 4 6 pole 132M 415/3/50 8.34 15/5 4/6 poles 180M 415/3/50 29.33/ 10.29 5.5 6 pole 132M 415/3/50 12.00 18.5/5.5 4/6 poles 180L 415/3/50 36.54/ 10.77 7.5 6 pole 160M 415/3/50 14.90 22/7.5 4/6 poles 200L 415/3/50 48.46/ 14.13 11 6 pole 160L 415/3/50 20.80 30/9 4/6 poles 200L 415/3/50 59.81/ 16.35 15 6 pole 180L 415/3/50 27.10 37/11 4/6 poles 225M 415/3/50 68.75/ 23.37 18.5 6 pole 200L 415/3/50 34.10 45/13.5 4/6 poles 250S 415/3/50 78.85/ 23.85 22 6 pole 200L 415/3/50 40.30 55/16.5 4/6 poles 250M 415/3/50 97.12/ 29.23 75/22 4/6 poles 280M 415/3/50 126.92/ 42.31 0.37 4 pole 71 415/3/50 1.03 0.55 4 pole 80 415/3/50 1.46 0.37/0.09 4/8 poles 80 415/3/50 1.29/0.5 0.75 4 pole 80 415/3/50 1.76 0.55/0.13 4/8 poles 80 415/3/50 1.83/ 0.67 1.1 4 pole 90S 415/3/50 2.58 0.75/0.18 4/8 poles 80 415/3/50 2.02/ 0.72 1.5 4 pole 90L 415/3/50 3.26 1.5/0.37 4/8 poles 90L 415/3/50 4.04/ 1.39 2.2 4 pole 100L 415/3/50 4.66 2.2/0.55 4/8 poles 100L 415/3/50 4.63/ 1.45 3 4 pole 100L 415/3/50 6.06 4/1.0 4/8 poles 112M 415/3/50 7.79/ 2.6 4 4 pole 112M 415/3/50 8.09 5.5/1.37 4/8 poles 132S 415/3/50 10.77/ 2.87 5.5 4 pole 132S 415/3/50 11.00 7.5/1.87 4/8 poles 132M 415/3/50 13.56/ 4.23 7.5 4 pole 132M 415/3/50 13.60 11/2.75 4/8 poles 160M 415/3/50 21.44/ 6.25 11 4 pole 160M 415/3/50 20.10 15/3.75 4/8 poles 160L 415/3/50 27.4/ 7.52 15 4 pole 160L 415/3/50 26.70 18.5/4.62 4/8 poles 180M 415/3/50 32.88/ 10.38 18.5 4 pole 180M 415/3/50 33.20 22/5.5 4/8 poles 200L 415/3/50 38.46/ 12.21 22 4 pole 180L 415/3/50 39.30 30/7.5 4/8 poles 200L 415/3/50 52.88/ 17.02 30 4 pole 200L 415/3/50 51.90 45/11.25 4/8 poles 225M 415/3/50 88.85/ 25.67 37 4 pole 225S 415/3/50 66.00 45 4 pole 225M 415/3/50 78.70 55 4 pole 250S 415/3/50 93.50 75 4 pole 250M 415/3/50 124.00 90 4 pole 280SC 415/3/50 154.00 110 4 pole 280MC 415/3/50 187.00 0.37 2 pole 71 415/3/50 0.81 0.55 2 pole 71 415/3/50 1.21 0.75 2 pole 80 415/3/50 1.51 1.1 2 pole 80 415/3/50 2.21 1.5 2 pole 90S 415/3/50 2.91 2.2 2 pole 90L 415/3/50 4.19 3 2 pole 100L 415/3/50 5.49 4 2 pole 112M 415/3/50 7.33 5.5 2 pole 132S 415/3/50 10.2 7.5 2 pole 132S 415/3/50 13.3 11 2 pole 160M 415/3/50 19.7 15 2 pole 160M 415/3/50 25.2 18.5 2 pole 160L 415/3/50 30.8

Accessories Matching Flanges Size A B C G H J L WT PCD Deg (kgs) 315 321 397 3 8 10 355 45 O 0.7 400 406 482 3 8 12 450 45 O 1.1 500 506 606 4.5 12 12 560 30 O 2.2 560 566 666 4.5 12 12 620 30 O 2.6 630 636 736 4.5 12 12 690 30 O 3.0 710 716 816 4.5 16 12 770 22.5 O 3.4 800 806 906 4.5 16 12 860 22.5 O 3.7 900 906 1006 4.5 16 15 970 22.5 O 6.0 1000 1006 1106 4.5 16 15 1070 22.5 O 6.5 1120 1129 1229 6 16 15 1175 22.5 O 7.3 1250 1259 1359 6 20 15 1320 18 O 8.0 Material & finish: Steel, hot dipped galvanished. All dimensions in millimetre (mm). Mounting Feets Size A B C D E F G H WT (kgs) 315 218 395 445 3 10 20 40 60 1.0 400 265 480 530 3 12 20 40 65 1.5 500 330 600 655 3 12 25 50 80 2.5 560 380 650 700 3 12 25 50 100 4.0 630 415 730 785 3 12 25 50 100 5.0 710 475 810 860 3 14 25 50 120 5.5 800 520 900 955 3 14 25 50 120 6.0 900 580 1000 1055 3 16 25 50 130 9.0 1000 635 1100 1155 3 16 25 50 135 12.0 1120 700 1220 1280 4.5 16 25 50 140 16.0 1250 775 1350 1420 4.5 16 25 50 150 19.0 Material & finish: Steel, hot dipped galvanished. All dimensions in millimetre (mm). INLET CONE Size A B C D E PCD Holes WT Diam (kgs) 315 321 397 3 55 400 355 10 2.0 400 406 482 3 70 510 450 12 3.0 500 506 606 4.5 90 640 560 12 5.0 560 566 666 4.5 100 715 620 12 6.0 630 636 736 4.5 110 800 690 12 9.0 710 716 816 4.5 125 890 770 12 11.0 800 806 906 4.5 135 995 860 12 13.0 900 906 1006 4.5 150 1110 970 15 18.0 1000 1006 1106 4.5 165 1230 1070 15 23.0 1120 1129 1229 6 185 1377 1175 15 28.0 1250 1259 1359 6 205 1525 1320 15 32.0 Material & finish: Steel, hot dipped galvanished. All dimensions in millimetre (mm).

Ihre Vertriebsniederlassung / your sales representative: