DEEP SEA ELECTRONICS PLC

Similar documents
DEEP SEA ELECTRONICS PLC

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC

Deep Sea Electronics Plc

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

DEEP SEA ELECTRONICS PLC

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL

DSEULTRA DSE6000 Quick Start Guide Document Number

DEEP SEA ELECTRONICS PLC

Deep Sea Electronics Plc

DEEP SEA ELECTRONICS PLC DSE3210 Configuration Suite Software Manual

Deep Sea Electronics Plc

DKG-114 MANUAL AND REMOTE START UNIT

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

Flight Systems. Replacement for KASSEC DESCRIPTION

GCU-10. Automatic Engine Control Unit Operators Manual

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

GENSET CONTROL MODULE A121A / A241A

PSM72H Push-Button Start Module

DEEP SEA ELECTRONICS PLC DSE3210 CONTROLLER OPERATORS MANUAL

REVISED ATM72 Auto Transfer Module

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

HSC940 Genset Controller CONTENTS 1 OVERVIEW PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION KEY FUNCTIONS...

GENSET CONTROL MODULE LEVEL 0 A120A. User selectable time delays for engine start and engine stop (cool down).

GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM. Special logic to re-establish cranking following a false start.

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

DEEP SEA ELECTRONICS

DEEP SEA ELECTRONICS

DEEP SEA ELECTRONICS DSE7110 MKII / DSE7120 MKII Configuration Suite PC Software Manual

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

HGM6410/6420. Automatic Generator Module. With J1939 Interface OPERATING MANUAL. Smartgen Electronics

4.2 Component Identification

USER MANUAL ZHENGZHOU SMARTGEN TECHNOLOGY CO.,LTD

HGM6410/6420 AUTOMATIC GENERATOR MODULE WITH J1939 INTERFACE SOFTWARE MANUAL

Manual and Remote Start Unit with Key Switch, 72x72 DIN Size

DEEP SEA ELECTRONICS PLC DSEE100 Operator Manual

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL

AUTOSTART 705S V1.00 AUTOSTART 710S / 720S / 730S V1.04 Programming Reference and Check Sheets

HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL

Energy Division

SDM72 Start on Demand Modules

EPM72 Engine Protection Module

GSC300 Auto Start Engine Controller

STANDARD OWNER S MANUAL

HGM6000K Series Automatic Generator Module OPERATING MANUAL Smartgen Electronic



ENGINE PROTECTION BOARD PDM1

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

ES52 Auto Start Engine Controller Installation and User Manual for the ES52 Auto Start Engine Controller.

ICON 2 1. FEATURES AND CHARACTEIRICS

InteliCharger V 20A Intelligent Automatic Battery Charger

KD LV Motor Protection Relay

20 KW / 25 KVA LIQUID COOLED POWERED by

AA4006 Speed Sensitive Trip Unit. User Manual

DKG-317 MANUAL AND REMOTE START UNIT

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

HGM6400 Automatic Genset Controller (With J1939 Interface) USER MANUAL Smartgen Technology

DEEP SEA ELECTRONICS PLC DSEL401 MKII Operator Manual

GSC300 Auto Start Engine Controller

GSC300. Auto Start Engine Controller. Installation and User Manual for the GSC300 Auto Start Engine Controller. Full Version

1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz.

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Ag Features. Multi-Stage Charging. Solar Panel or DC Input. Maximum Power Point Tracking (MPPT) Very Low Power Consumption

HGM6310D/6320D AUTOMATIC GENERATOR MODULE USER MANUAL

DEEP SEA ELECTRONICS PLC DSE9000 SERIES BATTERY CHARGER OPERATOR MANUAL

DKG-215 MANUAL AND REMOTE START UNIT

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

Controls and Instruments

DEEP SEA ELECTRONICS PLC DSE7450 Configuration PC Suite Software Manual. Document Number:

The measurements module provides the following engine features information:

INSTALLATION GUIDE Table of Contents

DEEP SEA ELECTRONICS PLC DSE6010 MKII & DSE6020 MKII Operator Manual

ADD-ON REMOTE STARTER TO AFTERMARKET SYSTEM

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

100 KW(NG) / 100 KW(LP) LIQUID COOLED POWERED by

DKG-207 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

Timer Relays - Fixed & Adjustable

AUTOMATIC STAND-BY AND PEAK-LOAD CONTROL

DEEP SEA ELECTRONICS PLC DSE6610 & DSE6620 Operator Manual

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

HGM6000K Series Automatic Generator Module USER MANUAL Smartgen Technology

ES52. Auto Start Engine Controller. Full Version. Installation and User Manual for the ES52 Auto Start Engine Controller.

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Elmdene International Ltd

USER MANUAL FOR GC500 GENSET CONTROLLER SEDEMAC ABSTRACT

ELECTRICAL SYSTEM RP-7

OPERATING INSTRUCTIONS ECON-M

Auto Mains Failure AMF Controller AE10113

DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT WITH PARALLEL TO MAINS AND DUAL GENSET PARALLEL FEATURES

Transcription:

DEEP SEA ELECTRONICS PLC 703 AUTOMATIC START MODULE OPERATING INSTRUCTIONS Author:- John Ruddock 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 1 -

<< This page is intentionally blank >> 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 2 -

TABLE OF CONTENTS 1 DESCRIPTION OF OPERATION...4 1.1 MANUAL MODE OPERATION... 4 1.2 AUTOMATIC MODE OF OPERATION... 5 1.3 WARNINGS... 6 1.4 SHUTDOWNS... 6 2 CONFIGURATION INSTRUCTIONS...7 3 CONFIGURATION TABLES...8 4 TERMINAL DESCRIPTION...11 5 SPECIFICATION...12 6 SOLID STATE OUTPUTS...13 6.1 TYPICAL CONNECTIONS... 13 7 ADDING A LOAD TRANSFER OUTPUT...14 7.1 CONNECTION DETAILS... 14 7.2 DESCRIPTION... 14 7.3 CONFIGURATION DETAILS... 14 8 DIMENSIONS...15 9 TYPICAL CONNECTIONS...15 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 3 -

1 DESCRIPTION OF OPERATION 1.1 MANUAL MODE OPERATION To initiate a start sequence in MANUAL, press the initiated. pushbutton, and the start sequence is NOTE:- There is no Start Delay in this mode of operation. If the pre-heat output option is selected this timer is then initiated, and the auxiliary output selected is energised. After the above delay the Fuel Solenoid is energised, then the Starter Motor is engaged. The engine is cranked for a 10-second period. If the engine fails to fire during this cranking attempt then the starter motor is disengaged for a 10-second period. Should this sequence continue beyond the 3 starting attempts, the start sequence will be terminated and Fail to Start will be illuminated. fault When the engine fires, the starter motor is disengaged and locked out at 20 Hz measured from the Alternator output. Rising oil pressure can also be used to disconnect the starter motor, however it cannot be used for underspeed or overspeed detection. After the starter motor has disengaged, the Safety On timer is activated (which is fixed at 12 seconds), allowing Oil Pressure, High Engine Temperature, Under-speed, Charge Fail and any delayed Auxiliary fault inputs to stabilise without triggering the fault. Selecting STOP de-energises the FUEL SOLENOID, bringing the generator to a stop. NOTE:- The safety on time (used for delayed alarms) is pre set to 12 seconds and can not be changed. 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 4 -

1.2 AUTOMATIC MODE OF OPERATION This mode is activated by pressing the Auto button confirms this action. pushbutton. An LED indicator beside the The start sequence is initiated when the remote start input is activated. To allow for false remote start signals, the Start Delay timer is initiated. After this delay, if the pre-heat output option is selected then the pre-heat timer is initiated, and the corresponding auxiliary output (if configured) will energise. NOTE: - If the Remote Start signal is removed during the Start Delay timer, the unit will return to a stand-by state. After the above delays the Fuel Solenoid is energised, then one second later, the Starter Motor is engaged. The engine is cranked for a 10-second period. If the engine fails to fire during this cranking attempt then the starter motor is disengaged for a 10-second rest period. Should this sequence continue beyond the 3 starting attempts, the start sequence will be terminated and Fail to Start fault will be illuminated. When the engine fires, the starter motor is disengaged and locked out at 20 Hz measured from the Alternator output. Rising oil pressure can also be used to disconnect the starter motor, however it cannot be used for underspeed or overspeed detection. After the starter motor has disengaged, the Safety On timer is activated, allowing Oil Pressure, High Engine Temperature, Under-speed, Charge Fail and any delayed Auxiliary fault inputs to stabilise without triggering the fault. Once the engine is running, the output Generator Running is activated if it has been configured. On removal of the Remote Start signal the Stop delay timer is initiated. Once this timer has expired the Fuel Solenoid is de-energised, bringing the generator to a stop. NOTE: - The safety on time (used for delayed alarms) is pre set to 12 seconds and can not be changed. 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 5 -

1.3 WARNINGS Warnings are used to warn the operator of an impending fault BATTERY CHARGE FAILURE, if the module does not detect a voltage from the warning light terminal on the auxiliary charge alternator, the icon will illuminate. (Either 8 Volts or 16 Volts, depending on the configuration of Nominal DC Voltage). Inputs 1 and 2 can be configured as warnings or shutdowns. The relevant icon will be illuminated when the input is active 1.4 SHUTDOWNS Shutdowns are latching and stop the Generator. The alarm must be cleared, and the fault removed to reset the module. In the event of a shutdown the appropriate icon will be illuminated NOTE: - The alarm condition must be rectified before a reset will take place. If the alarm condition remains it will not be possible to reset the unit (The exception to this is the Low Oil Pressure alarm and similar delayed alarms, as the oil pressure will be low with the engine at rest). Any subsequent warnings or shutdowns that occur will be displayed steady, therefore only the first-up shutdown will appear flashing. NOTE: - The safety on time (used for delayed alarms) is pre set to 12 seconds and can not be changed. FAIL TO START, if the engine does not fire after the pre-set 3 attempts at starting, a shutdown will be initiated. The icon will illuminate. LOW OIL PRESSURE, if the module detects that the engine oil pressure has fallen below the low oil pressure switch after the Safety On timer has expired, a shutdown will occur. The icon will illuminate. HIGH ENGINE TEMPERATURE if the module detects that the engine coolant temperature has exceeded the high engine temperature switch after the Safety On timer has expired, a shutdown will occur. The icon will illuminate. OVERSPEED, if the engine speed exceeds the pre-set trip (14% above the nominal frequency) a shutdown is initiated. Overspeed is not delayed, it is an immediate shutdown. The icon will illuminate. NOTE:- During the start-up sequence the overspeed trip level is extended to 24% above the normal frequency for the duration of the safety timer to allow an extra trip level margin. This is used to prevent nuisance tripping on start-up. UNDERSPEED, if the engine speed falls below the pre-set trip (20% of the nominal frequency) after the Safety On timer has expired, a shutdown is initiated. The icon will illuminate. Inputs 1 and 2 can be configured as warnings or shutdowns. The relevant icon will be illuminated when the input is active 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 6 -

2 CONFIGURATION INSTRUCTIONS? With the unit in Stop mode, Configuration Mode is selected by operation of a small switch on the rear, left-hand edge of the PCB. This is partially hidden to prevent accidental operation. Normal Configuration? Once Configuration Mode is selected, the Auto LED will commence rapid flashing, and all normal operation is suspended.? The Stop pushbutton can be used to select the LED code that corresponds to the required function. The 5 left-hand LED s will form the code. See configuration table over leaf.? The Manual pushbutton will allow the user to change the associated value. The 3 righthand LED s inform the user of the current setting for the chosen function. See configuration table over leaf.? When the required parameters are displayed, pressing the Auto button will save the new setting, and the process is repeated for each function change.? When configuration is complete, the Configuration Mode Selector Switch should be returned to the Normal position. Parameter Value 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 7 -

3 CONFIGURATION TABLES FUNCTIONS AND CONFIGURATION TABLE Function! 1! 2 Value (Default in Bold) Pre-heat Timer 0 Seconds 5 Seconds 10 Seconds 15 Seconds 20 Seconds 30 Seconds 60 Seconds 180 Seconds Used to pre-heat the engine prior to cranking. The output is active for the duration of the setting, prior to cranking. Start Delay 0 Seconds 5 Seconds 10 Seconds 15 Seconds 20 Seconds 30 Seconds 60 Seconds 180 Seconds Used to give a delay between activating the remote start input and actually starting the engine. Stop Delay 0 Seconds 5 Seconds 10 Seconds 15 Seconds 20 Seconds 30 Seconds 60 Seconds 180 Seconds Used to give a delay between deactivating the remote start input and actually stopping the engine. Energise to Stop Hold Timer 0 Seconds 5 Seconds 10 Seconds 15 Seconds 20 Seconds 30 Seconds 60 Seconds 180 Seconds Used for the control of the engine stop solenoid. When the engine is to be stopped, the Energise To Stop output becomes active, closing the stop solenoid (fuel valve). When the engine comes to rest, the stop solenoid will remain energised for the period of the Energise To Stop Timer, to ensure the engine has come to a complete stop. Nominal Frequency The systems nominal frequency. Either 50 Hz or 60 Hz 50 Hz (O/S +14% / Overshoot +24%) 60 Hz (O/S +14% / Overshoot +24%) Nominal DC Voltage 12V DC (CF 8V) 24V DC (CF 16V) The generator battery voltage. Either 12 Volts or 24 Volts. It is used for the charge alternator failure level. LOP Switch Contact Close on Fault Open on Fault Configuration for the oil pressure switch. Either to close to battery negative on a fault, or open on a fault. 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 8 -

FUNCTIONS AND CONFIGURATION TABLE Function! 1! 2 Value (Default in Bold) HET Switch Contact Close on Fault Open on Fault Configuration for the coolant temperature switch. Either to close to battery negative on a fault, or open on a fault. Crank disconnect on Disabled Oil Pressure Enabled (2 Second Delay) If this is enabled, the starter motor will disconnect 2 seconds after the oil pressure switch detects oil pressure. NOTE:- Not suitable for all generators, due to the different monitoring points on lubrication systems. Underspeed Disabled Detection Enabled (U/S 20%) If this is enabled, the unit will shut down the generator if the frequency falls below 20% of the nominal frequency. Auxiliary Input 1 Immediate Warning Function Close on Fault Immediate Warning Open on Fault Immediate Shutdown Close on Fault Immediate Shutdown Open on Fault Delayed Warning Close on Fault Delayed Warning Open on Fault Delayed Shutdown Close on Fault Delayed Shutdown Open on Fault Programmable input, can be configured to on of the following? Immediate warning close on fault If the input is activated at any time the unit will alarm and energise the common warning and common alarm output.? Immediate warning open on fault If the input is deactivated at any time the unit will alarm and energise the common warning and common alarm output.? Immediate shutdown close on fault If the input is activated at any time the generator will be shutdown and energise the common warning and common shutdown output. The generator can not be started.? Immediate shutdown open on fault If the input is deactivated at any time the generator will be shutdown and energise the common warning and common shutdown output. The generator can not be started.? Delayed warning close on fault If the input is activated and the saftey time has elapsed the unit will alarm and energise the common warning and common alarm output.? Delayed warning open on fault If the input is deactivated and the saftey time has elapsed the unit will alarm and energise the common warning and common alarm output.? Delayed shutdown close on fault If the input is activated and the saftey time has elapsed the generator will be shutdown and energise the common warning and common shutdown output.? Delayed shutdown open on fault If the input is deactivated and the saftey time has elapsed the generator will be shutdown and energise the common warning and common shutdown output. 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 9 -

FUNCTIONS AND CONFIGURATION TABLE Function! 1! 2 Value (Default in Bold) Auxiliary Input 2 Immediate Warning Function Close on Fault Immediate Warning Open on Fault Immediate Shutdown Close on Fault Immediate Shutdown Open on Fault Delayed Warning Close on Fault Delayed Warning Open on Fault Delayed Shutdown Close on Fault Delayed Shutdown Open on Fault Programmable input, can be configured to on of the following? Immediate warning close on fault If the input is activated at any time the unit will alarm and energise the common warning and common alarm output.? Immediate warning open on fault If the input is deactivated at any time the unit will alarm and energise the common warning and common alarm output.? Immediate shutdown close on fault If the input is activated at any time the generator will be shutdown and energise the common warning and common shutdown output. The generator can not be started.? Immediate shutdown open on fault If the input is deactivated at any time the generator will be shutdown and energise the common warning and common shutdown output. The generator can not be started.? Delayed warning close on fault If the input is activated and the saftey time has elapsed the unit will alarm and energise the common warning and common alarm output.? Delayed warning open on fault If the input is deactivated and the saftey time has elapsed the unit will alarm and energise the common warning and common alarm output.? Delayed shutdown close on fault If the input is activated and the saftey time has elapsed the generator will be shutdown and energise the common warning and common shutdown output.? Delayed shutdown open on fault If the input is deactivated and the saftey time has elapsed the generator will be shutdown and energise the common warning and common shutdown output. Auxiliary Output 1 Function Not used Pre-heat Engine Running Common Warning Common Shutdown System in Auto Common Alarm Energise to Stop Programmable output can be configured to one of the following.? Pre-heat. - The output is energised for the period of pre-heat time prior to cranking, and between the cranking attempts.? Engine Running. - The output is active after the saftey timer has elapsed.? Common warning. - The output is active if there are any warning alarm active.? Common shutdown - The output is active if there are any shutdown alarms active.? System in auto. - The output is active when the system is in automatic mode.? Common Alarm. - The output is active if there is any alarm condition.? Energise to stop. - The output is energised when the engine is required to stop (normal or fault conditions), and will remain energised for the period of the Energise To Stop Timer, to ensure the engine has come to a complete stop. 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 10 -

FUNCTIONS AND CONFIGURATION TABLE Function! 1! 2 Value (Default in Bold) Auxiliary Output 2 Not used Function Pre-heat Engine Running Common Warning Common Shutdown System in Auto Common Alarm Energise to Stop Programmable output can be configured to one of the following.? Pre-heat. - The output is energised for the period of pre-heat time prior to cranking, and between the cranking attempts.? Engine Running. - The output is active after the saftey timer has elapsed.? Common warning. - The output is active if there are any warning alarm active.? Common shutdown - The output is active if there are any shutdown alarms active.? System in auto. - The output is active when the system is in automatic mode.? Common Alarm. - The output is active if there is any alarm condition.? Energise to stop. - The output is energised when the engine is required to stop (normal or fault conditions), and will remain energised for the period of the Energise To Stop Timer, to ensure the engine has come to a complete stop. 4 TERMINAL DESCRIPTION PIN DESCRIPTION CABLE NOTES No SIZE 1 DC Plant Supply Input 1.0mm Connected to plant battery negative (-ve) 2 DC Plant Supply Input (+ve) 1.0mm Connected to plant battery positive (Recommended Fuse 2A) 3 Fuel relay Output 1.0mm Used to operate the fuel relay. 4 Start relay Output 1.0mm Used to operate the cranking relay. 5 Auxiliary Output relay 1 1.0mm Configurable output. 6 Auxiliary Output relay 2 1.0mm Configurable output. 7 Charge Fail Input/ Excitation Output 1.0mm Must NOT be connected to plant supply negative if not used. 8 Low Oil Pressure Input 0.5mm Switch to negative. 9 High Engine Temp Input 0.5mm Switch to negative. 10 Auxiliary Input 1 0.5mm Switch to negative. 11 Auxiliary Input 2 0.5mm Switch to negative. 12 Remote Start Input 0.5mm Switch to negative. 13 Not Used 14 Not Used 15 Functional Earth 1.0mm Connect to a good clean earth point 16 Not Used 17 Not Used 18 Not Used 19 Not Used 20 Alternator Input L1 1.0mm Do not connect if not used. (2A Fuse) 21 Alternator Input N 1.0mm Do not connect if not used. NOTE:- All the outputs are solid state, rated at 1.2 Amps 8 Volts to 35 Volts DC, and switch to battery negative when active. 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 11 -

5 SPECIFICATION DC Supply: 8 Volts to 35 Volts DC Continuous. Cranking Dropouts: Able to survive 0 Volts for 50 ms, providing supply was at least 10 V before dropout and supply recovers to 5 Volts. This is achieved without the need for internal batteries. Max. Current: Operating 50mA Standby 10mA Alternator Input Range: 75 Volts (ph-n) to 277 Volts (ph-n) AC (+20%) Alternator Input Frequency: 50-60 Hz at rated engine speed (Minimum: 75V AC Ph-N) (Crank Disconnect from 15V Ph-N @ 20Hz) Overspeed +14% (+24% overshoot) Underspeed 20% Start Output: 1.2 Amp DC at supply voltage. Fuel Output: 1.2 Amp DC at supply voltage. Auxiliary Outputs: 1.2 Amp DC at supply voltage. Dimensions: 125mm x 165mm x 28 mm Charge Fail: 12 Volts = 8 Volts CF 24 Volts = 16 Volts CF Operating Temperature Range: -30?C to + 70 0 C Applicable Standards Compliant with BS EN 60950 Low Voltage Directive Compliant with BS EN 50081-2: 1992 EMC Directive Compliant with BS EN 61000-6-4: 2000 EMC Directive Compliance to European Legislation Registered Component for USA & Canada Deep Sea Electronics plc reserve the right to change specification without notice. 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 12 -

6 SOLID STATE OUTPUTS DSE s utilisation of Solid State Outputs gives many advantages, the main points being:? No Moving Parts? Fully Overload / Short Circuit Protected.? Smaller dimensions hence lighter, thinner and cheaper than conventional relays.? Less power required making them far more reliable. The main difference from conventional outputs is that solid state outputs switch to negative ( ve) when active. This type of output is normally used with an automotive or plug in relay. 6.1 TYPICAL CONNECTIONS Solid state output from DSE module eg. Terminal 3 of 703/4 - FUEL Fuel Solenoid (+ terminal) * Observe polarity when using relays fitted with integral diodes! A D * B C Battery positive (+) Solid State Output Automotive 8 Pin Plugin relay Function from DSE Module Pin relay Pin A 3 86 7 Fuel Output B 85 2 To Positive supply via fuse C 30 1 To Positive supply via fuse D 87 3 To Fuel Solenoid Example of relay pins connected to DSE solid state output to drive a fuel solenoid. See section on Typical Connections else where in this manual for overall typical wiring diagram 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 13 -

7 ADDING A LOAD TRANSFER OUTPUT The DSE 703 is a very flexible, low cost, remote start module. It can be further enhanced by the addition of simple external wiring to convert the Engine Running output into a Load Transfer output. This allows the 703 module to control a load-switching device, while also giving provision for a Cooling Run. 7.1 CONNECTION DETAILS 703 remote start module Remote start signal ( switched to battery -ve) Remote start input Engine running output Diode Load transfer output Battery +ve 7.2 DESCRIPTION DC relay With the 703 in AUTO mode, applying the remote start signal will begin the start delay timer, after which, the engine will be called upon to start. Upon activation of the Engine Running output, the DC relay will close, switching the remote start signal through its contacts. This switched signal becomes the Load Transfer output, which can be used to drive a DC load-switching device or further slave relay if required. When the remote start signal is removed, this also removes the Load Transfer output (opening the contractor) and begins the 703 s Stop Delay timer. This acts as a cooling timer to allow the set to cool off load. When the Stop Delay timer expires, the set will be stopped. NOTE:- The diode acts to stop any voltage from the 703 s remote start input circuitry being fed through the DC relay. 7.3 CONFIGURATION DETAILS Auxiliary output 1 Function Engine running Stop Delay timer Timer value Select as required Please see the 703 installation instructions for further details of the 703 configuration 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 14 -

8 DIMENSIONS Dimensions: 165mm x 125mm x 29mm (6.5 x 4.9 x 1.2 ) Panel cut out: 149mm x 109mm (5.9 x 4.3 ) Mounting Method: 4 x 4.2mm diameter holes suitable for M4 screws. 9 TYPICAL CONNECTIONS F 2A 21 20 15 Fuel o/p SSO Start o/p 1 2 3 4 5 6 7 SSO Auxiliary Outputs SSO SSO Auxiliary Alarm Inputs 8 9 10 11 12 + + + + F2A F + Battery Fuel Starter motor Crank Charge alt SSO = Solid state outputs = External 'Automotive' or 'Plug-in' type relays Terminals suitable for 22-16 awg (0.6mm 2-1.3mm 2 )field wiring Tightening Torque = 0.8N-m (7lb-in) 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 15 -

DEEP SEA ELECTRONICS PLC 703 Auto Start Issue 5 USA 13/06/02 DESCRIPTION The 703 is an engine auto start and protection module. It utilizes advanced surface mount construction techniques to provide a compact, yet highly specified module. Operation is via three pushbuttons mounted on the front panel with STOP, MANUAL and AUTO positions. OPERATION Stop mode - This is used to stop the engine when it is running and to cancel Auto mode. It is also used to reset any Shutdown Alarm conditions. Manual mode - This mode is used to manually start and run the engine, which can be stopped by pressing the Stop button. Auto mode - This selects the automatic mode of operation, in which the module will await the remote start signal. Once received, the module will initiate its preconfigured Start Sequence, observing the start delay timer before starting the engine. When the remote start signal is removed, the module will initiate its preconfigured Stopping Sequence. The module monitors the engine and provides the following functions: Automatic Start with 3 attempts and Automatic Crank Disconnect - with adjustable Start and Stop Timers and Fail to Start indication. Configurable Pre-heat and Energize to Stop functions. Low Oil Pressure and High Engine Temperature Shutdown. Overspeed and Underspeed (frequency) protection. Charge Fail Alarm Two fully configurable auxiliary inputs. All alarms are indicated by high visibility red LED s. The module s microprocessor provides a comprehensive list of timers and configurable functions. Parameter settings can be adjusted using the front panel pushbuttons once in Configuration Mode. Access to the settings is via a small Configuration Switch on the rear of the module (see figs. 1 and 2), and enables changes to be made in the field. Selection of the Configuration Mode is indicated by rapid flashing of the Auto LED. The module is designed with DSE s proven experience and uses modern construction to provide a high level of reliability and suitability for the intended operating environment. Issues such as environmental compliance and EMC have been carefully engineered into the design. Advanced features such as protected solid state outputs mean that there are no moving parts or contacts to burn-out. FEATURES Micro-processor based design Automatic Engine Starting and Stopping Automatic Shutdown on fault condition Configurable via front panel Simple pushbutton controlled operation Configurable Digital Inputs Configurable Solid State Outputs Configurable Timer Settings Solid State Fuel and Crank outputs External Remote Start input LED Alarm indication Start Delay Timer Stop Delay Timer Energize to Stop timer Pre-heat Timer Over Speed Shutdown Optional Underspeed Protection Low Oil Pressure Shutdown High Engine Temp Shutdown Optional Crank Disconnect from Oil Pressure The 700 series modules have been designed for front panel mounting. The module is fitted into the cut-out, and screw holes are provided for secure fixing. SPECIFICATION DC Supply: 8 to 35 V Continuous. Cranking Dropouts: Able to survive 0 V for 50 ms, providing supply was at least 10 V before dropout and supply recovers to 5V. This is achieved without the need for internal batteries. Max. Current: Operating 50mA Standby 10mA Alternator Input Range: 75(ph-N) to 277(ph-N) 3 Phase 4wire AC (+20%) Alternator Input Frequency: 50-60 Hz at rated engine speed (Minimum: 75V AC Ph-N) (Crank Disconnect from 15V Ph-N @ 20 Hz) Overspeed +14% (+24% overshoot) Underspeed 20% Start Output: 1.2 Amp DC at supply voltage. Fuel Output: 1.2 Amp DC at supply voltage. Auxiliary Outputs: 1.2 Amp DC at supply voltage. Dimensions: 125 X 165 X 28 mm Charge Fail: 12V = 8V CF 24V = 16V CF Operating Temperature Range: -30 to +70 C Compliant with BS EN 60950 Low Voltage Directive Compliant with BS EN 50081-2 EMC Directive Compliant with BS EN 50082-2 EMC Directive Deep Sea Electronics reserve the right to change specification without notice.

109 CONFIGURATION Configuration Mode is selected by operation of a small switch on the rear, left-hand edge of the PCB. This is partially hidden to prevent accidental operation. See figs 1 and 2 Fig. 1 Normal Configuration Once Configuration Mode is selected, the Auto LED will commence rapid flashing. When in Configuration Mode all normal operation is suspended. The Stop pushbutton can be used to select the LED code that corresponds to the required function. The 5 left hand LED s will form the code The Manual pushbutton will allow the user to change the function parameters. The 3 right-hand LED s inform the user of the current value for the chosen function. When the required parameters are displayed, pressing the Auto button will save the new setting. The process is repeated for each function change. When configuration is complete, the Configuration Mode Selector Switch should be returned to the Normal position. A key to all configuration options is provided (refer to Installation Instructions supplied with module). 125 114 Fig. 2 Diagram of reverse side of 703 10.85 4 149 154 25 Panel Cut-out: 149 x 109 165 Fig. 3 Dimensions (mm) F 2A TYPICAL CONNECTIONS 21 20 15 Fuel o/p SSO Start o/p 4 1 2 3 5 6 7 SSO Auxiliary Outputs SSO SSO Auxiliary Alarm Inputs 8 9 10 11 12 + + + + F2A F + Battery Fuel Starter motor Crank Charge alt SSO = Solid state outputs = External 'Automotive' or 'Plug-in' type relays Deep Sea Electronics plc Highfield House, Hunmanby Industrial Estate, North Yorkshire, YO14 0PH, England Tel: +44 (0) 1723 890099 Fax: +44 (0) 1723 893303 E-mail sales@deepseaplc.com