Small Motor Control (1/4 HP HP)

Similar documents
University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

BAC Custom Engineered Controls

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

SECTION MOTORS & MOTOR CONTROLLERS

SECTION MOTOR CONTROL

Design Standards NEMA

SECTION ENCLOSED CONTROLLERS

PREVIEW ONLY - FULL COPY AVAILABLE TO CONSORTIUM MEMBERS. Escalator Specific Electrical Systems. Course 209 PARTICIPANT GUIDE

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Installation and Construction Notes for EVSE4

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

WARREN COUNTY, N.Y. M/E REFERENCE

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Enclosed Full-Voltage Starters

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

Enclosed Full-Voltage Starters

Product Guide. enclosed NEMA STARTERS

Standby Power Systems

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Product guide. Enclosed NEMA starters. Answers for industry.

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

MAGNETIC MOTOR STARTERS

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

SECTION MOTOR CONTROLLERS

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Programmable Logic Controller. Mat Nor Mohamad

OTEC Transfer switch open transition

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

IAE-101: Electrical Fundamentals for Non-Electrical Personnel

SECTION MOTOR CONTROLLERS

Mechanical Considerations for Servo Motor and Gearhead Sizing

Optimizing Emergency Power Systems for Health Care Applications

Application Description

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

Ice Rink Renovation & New Clubhouse

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

Electric Motor Controls BOMA Pre-Quiz

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

Basics of Control Components

Wastewater Solutions. DECONTACTOR TM Series. Featuring Meltric s. Switch Rated Plugs, Receptacles and Electrical Connectors

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

Introduction. Upon completion of Motor Control Centers, you should be able to: Explain the role of motor control centers in a distribution system

Devices for Branch Circuits and Feeders

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

STEP Motor Control Centers

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear

Series 774 Automatic Skid Package

MOLDED CASE CIRCUIT BREAKER BASICS. David Castor, P.E.

ASCO Low Voltage Automatic Transfer Switch Systems

ELECTRICAL TECHNOLOGY 3 March 2008

Application Techniques. North American Standards, Configurations, and Ratings: Introduction to Motor Circuit Design

Generator/Loadbank Quick Connection Tap Box

SIGNAL WORDS QUALIFIED PERSON

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems

Transformer Protection

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Compact Circuit Protector (CCP) Application Note

Unified requirements for systems with voltages above 1 kv up to 15 kv

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Transfer switch OTEC and OTECSE open transition

Low Voltage Automatic Transfer Switch Systems

IT. IEC Contactors, Starters, Overload Relays, and Accessories Product Focus

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (2 of 2) Lecture 6 Contactors and Motor Starters

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

team master medium voltage solid state starters

Air Circuit Breakers

Reduced Voltage Motor Starters

Advanced Guide To Understanding Assembly Short-Circuit Current Rating WITH ENGINEERING SOLUTIONS AND OVERCURRENT PROTECTION DEVICES TO ENHANCE SCCR

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Bussmann series Quik-Spec Power Module Switch elevator disconnect

IN2 Enclosed Switches and Circuit Breakers

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Now - Up To 400A Mains!

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

PATTERSON PUMP COMPANY

SECTION VARIABLE FREQUENCY DRIVE UNITS

Air Circuit Breakers

MOTOR TERMINAL CONNECTIONS

Bussmann series Quik-Spec Coordination Panelboard

4-Day Power System Analysis, Coordination, System Studies

Transcription:

PDHonline Course E110 (2 PDH) Small Motor Control (1/4 HP - 200 HP) Instructor: Thomas Mason, P.E. 2012 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088 www.pdhonline.org www.pdhcenter.com An Approved Continuing Education Provider

Small Motor Control (1/4 HP 200 HP) Thomas Mason, P.E. Course Content With some exceptions, motor control is performed by the combination of a very few devices, as follows: Power disconnect switch Instantaneous overcurrent protection Long-time overload protection Hand-Off-Auto selector switch or, Start-Stop pushbuttons and, sometimes, External emergency-stops, interlocks and permissives Auxiliary contacts Control power is required or desirable on most control circuits Starter NEMA Sizes Starter NEMA Enclosures Each of these devices is discussed below, with demonstration drawings. There is an ANSI standard for drawing symbols, but those used below are typical of commercial use and consistent with the National Electrical Code. Power disconnect switch: On the smallest fractional horsepower motors, a plug and receptacle can act as a power disconnect switch. Even on very small motors, it is desirable to use an enclosed motor-rated switch. This switch can be stand-alone in a separate box, combined with a fuse, combined into a thermal-magnetic circuit breaker, combined with a motor overload device or included in a combination motor starter. (Combination motor starter means a combination of disconnect switch, protection and start-stop control, in a single enclosure.) Instantaneous overcurrent protection: Short-circuit protection is required for the wires between the controls and the motor. This is provided by the fast-acting portion of a fuse or the magnetic portion of a circuit breaker. Because of the inductive inrush and start-up inertial acceleration of the motor, instantaneous protection is set well above the running-rating of the motor. Long-time overload protection: Very small motors are self-protected, usually containing a winding thermostat (brand name Klixon) which disconnects power when excessive heat is generated. Even small motors are better protected by external motor overload protective relays, normally called overloads. For this discussion, mechanical overload protective relays will be discussed, though the function is being replaced by solid-state devices, sometimes incorporated in Smart motor starters. Overloads have a heater and time-temperature characteristic on the relay contacts. Very-high short term overloads are permitted for inrush and acceleration but long-term trip is promised at a value very close to the motor full-load rating. Replaceable heaters assure that the adjustment is available. Improper overloads, usually caused by lack of care in selection, cause false motor-trips or motor failure without shutdown. Hand-Off-Auto selector switch: The operator must start the motor, either individually, or as part of a sequence. A Hand-Off-Auto selector switch meets this need well. Off is the not-running position. (However, OSHA requires that the power disconnect switch be opened and sometimes locked out.) In the Hand position, the motor runs. (A major controversey rages on whether safeties, interlocks and permissives are bypassed in Hand. Greatest safety and lowest design

liability exist when safeties, interlocks and permissive are left in the circuit. Maintenance becomes more difficult.) In the Auto position, a external switch, relay, PLC or other external device starts the motor. In both Hand and Auto, the motor runs until a controlled stop command is received, the power disconnect is opened or the overload trips. Start-Stop pushbuttons: Pushbuttons normally indicate local operator control. However, a remote relay contact may be wired in parallel with the local Start pushbutton. Similarly, a remote normally-closed contact may be wired in series with the local Stop button. Both Starts work. Both Stops work. Either Stop overrides either start. There is a potential for unexpected operation unless a maintained local stop button is used. OSHA requires that the power disconnect switch be used during maintenance, though some Owners still require lockable Stop buttons. External emergency-stops, interlocks and permissives: For this discussion, normal operation is commanded via the H-O-A control circuit or the Start-Stop control circuit. A separate class of controls operates only during abnormal conditions. An Emergency Stop button, a trip wire or a light curtain stop the machine for personnel safety reasons. By the National Electric Code, these E- Stops must be in the control circuit before the H-O-A or Start-Stop. CAUTION: many designers do not realize this and place the E-Stop after the H-O-A switch. Interlocks and permissives refer to the sequence of operations among multiple motors or devices. Formally, Interlocks are commands to downstream motors and permissives are commands received from upstream devices. The terms, however, are used loosely in the field. For a series of conveyors, #1 which feeds #2 and #2 feeds #3. We will look at the middle unit, #2. Before #2 can start, #3 should be running to assure there is a place to deposit the contents of #2. Therefore an auxiliary motor start contact from the #3 starter is connected into #2 as a permissive before the normal controls. When #2 is running, it is OK to start #1, so an auxiliary contact from the #2 motor starter is used to interlock #1, before the normal controls. Interlocks and permissives can also be pressure switches, thermostats or time-delay relays. Obviously, this function is rapidly migrating to PLC s. Auxiliary contacts: The relay which is used to start and stop the motor must have heavy-duty power contacts to close on inrush current and break inductive current when the motor stops. It is common to provide small, pilot-duty contacts on the same relay for control purposes. [Pilot-duty applies to 120V, 5A contacts which will operate all but the largest motor contactors. Motor-rated is the term for 480V, 20A contacts which will carry inrush and interrupt inductive current. Reed-relays, rated 24V, 1A are sometimes provided with Programmable Logic Controllers (PLC s).] Control power: Many years ago, the motor power leads were tapped and connected to the H-O-A selector or Start-Stop pushbuttons and to a line-voltage motor relay (contactor). This is still permitted, with severe limitations. Years later, with the advent of motor control centers, it became common to include a lighting/control transformer and distribution panel in one vertical section. The panel provided 120V control power to the motor starters. UL made this impractical by requiring a control power disconnect along with the main power disconnect. A remnant remains in a rare requirement for power disconnect switches at the motor which contain a control power interlock switch for the starter. The standard today is for two fuses connected to the motor power leads after the power disconnect, a control transformer, a grounded leg and a fused control leg. An oversize control transformer is required if indicator lights and auxiliary relays are used. The National Electrical Code The organization of the 2002 National Electric Code is as follows: Introduction 80 - Administration [not enforceable Code] Introduction 90 - Introduction [valuable discussion but not enforceable Code] Chapter 1, Section 100 - Definitions [extremely valuable and enforceable]

Chapter 1, Section 110 - Requirements [requires reading and re-reading; enforceable] Chapter 2 Wiring and Protection [see annotated Table of Contents - separate PDHonline course] Chapter 3 - Wiring Methods [Definitions of rigid and flexible conduits and open power wiring and limitations] Chapter 4 - Equipment for General Use [Flexible cords, switches, panels, lighting and much more] Section 430 - Motors and Motor Control Chapter 5 Special Occupancies [hazardous areas, garages, health care, theaters and more] Chapter 6 - Special Equipment [signs, hoists, elevators, information technology and more] Chapter 7 - Special Conditions [Emergency generators, low-voltage wiring, fire alarm wiring and more] Chapter 8 - Communications Systems [radio, tv, powered data circuits and more] Chapter 9 - Tables Annexes, formerly appendices [not enforceable] Starter NEMA Sizes 460V Mot or HP 10 1 25 2 50 3 100 4 200 5 NEMA Starte r Size Starter NEMA Enclosures NEMA Application Comment Enclosure 1 Indoor General Purpose; Common Commercial Use Tests: rod entry, rust 3R Outdoor Raintight; Commercial and Industrial Tests: rain, rod entry, icing, rust 4X Corrosion Resistant, Indoor, Outdoor; Tests: hose-directed salt spray, blown dust, rain, corrosion (Stainless Steel) 7 Explosion-Proof Identify Hazardous Class, Division and Group 12X Corrosion Resistant; Premium 4X, often RRP

Simplified Three-Wire Diagram The power circuit for motor control is shown below. It is important to become familiar with the terminology, as it is the basis for regulations listed in NFPA 70, the National Electric Code. Manual Motor Starter The complete diagram for a simple manual motor starter is shown below. This form is economic, reliable and maintainable. The disconnect must be lockable and within sight of the motor. This is a common situation in air conditioning machine rooms.

Combination Starter with H-O-A Selector Below, please note the complete diagram for a combination starter with Hand-Off-Auto selector switch and remote Emergency Stop, permissive and computer control. Such diagrams were formerly provided in catalogs from General Electric, Westinghouse, Square D and Cutler-Hammer. This diagram is a bit more detailed, including the ground power conductor and notation for remotely located devices. The H-O-A and indicators are located in the front of the starter. The overload heaters are part of the overload protective relay. This form is no longer the economic choice, as integrated IEC units are legal and reliable when properly applied, much smaller and less expensive. The components in the IEC unit are identical, but less accessible and not visibly obvious. The control portion of this diagram is called a ladder diagram due to its form. Through the early days of programmable logic controllers (PLC s), this was the universal expression of motor control. With a little experience, the logic of the controls can be followed and a voltage tester can verify operation for maintenance. Project Managers, Chemical Engineers and Mechanical Engineers could participate in controls design and review. Combination Starter with H-O-A Selector and Remote Start-Stop Below is the complete power and control diagram for a combination motor starter with H-O-A in the starter and remote Start-Stop pushbutton station with status lights This form demonstrates use of an auxiliary relay for conversion of momentary control to maintained control, called seal-in. The diagram shown was actually used at a large chemical plant constructed in the 1980 s. It is valuable to follow current flow with a finger and postulate results of a ground-fault at each point. This approved circuit is fail-safe, that is, an open or cross fault cause shutdown, not uncontrolled operation. This control circuit is a bit peculiar. Most large industrial firms and utilities require standard control circuits which can be very peculiar. Many survive from the 1980 s and before, so understanding the

logic is relevant and the finger-testing method still works on the power components of the control circuit. The control relay costs more than a commodity PLC. The replacement PLC permits remote monitoring, alarming and interlocking at no substantial cost. Controls vendors encourage purchase of smart motor starters, which incorporate electronic overloads, proprietary data communications and features added frequently. Solid-state contactor are offered, with soft-start. Initial cost is competitive with electromechanical controls. Startup must be performed by a skilled technician. In rare cases, plant electricians are trained to perform troubleshooting. Automatic Motor Control A simple pump requires safety interlocks. The previous discussions apply. A complex machine, such as an elevator or crane control is much more complex. Industrial machine controls are complex Electromechanical controls were very complex. Electronic controls are even more complex, as regulations continue to grow. The difficulty of reviewing the power connections for a modern control system is real. The difficulty of reviewing the software logic is substantial for skilled programmers. Neither the power side nor the software side of computerized motor control is addressed here. NFPA 79, Electrical Standard for Industrial Machinery provides standards for such modern motor control. NFPA 79, Electrical Standard for Industrial Machinery Table of Contents Ch 1 - Administration Ch 2 - Referenced Publications Ch 3 - Definitions Ch 4 - General Operating Conditions Ch 5 - Incoming Supply Circuit Conductor Terminations and Devices for Disconnect

Ch 6 - Protection from Electric Shock Ch 7 - Protection of Equipment Ch 8 - Grounding Ch 9 - Control Circuits and Control Funcitons Ch 10 - Operator Interface and Control Devices Ch 11 - Electronic Equipment Ch 12 - Control Equipment: Location, Mounting, and Enclosures Ch 13 - Conductors, Cables, and Flexible Cords Ch 14 - Wiring Practices Ch 15 - Electric Motors and Associated Equipment Ch 16 - Accessories and Lighting Ch 17 - Marking and Safety Signs Ch 18 - Technical Documentation Ch 19 - Testing and Verification Annex A - Explanatory Material Annex B - Inquiry form for Electrical Equipment of Machines Annex C - Examples of Industrial Machines Covered bynfpa 79 Annex D - Technical Documentation Annex E - Device and Component Designations Annex F - Electrical Enclosure Ratings: Type-Ratings Versus IP-Rating Annex G - Kilowatt Outputs with Horsepower Equivalents Annex H - Corss-Reference Tables Annex I - Minimizing the Probability of Control function Failure Annex J - Informational References Index