Diagnostic Test Kit Series P Series WARNING. for Polaris Robotic Cleaners

Similar documents
AquaPure Ei TM Series Replacement Kits

Jandy Pro Series NeverLube and Backwash Valve

Installation Instructions Shaper 1800 aircraft cable installation

Installation Instructions - Continua Suspended LED

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

RSA-MRZ Installation Instructions

RSA-MRZ Installation Instructions

Polaris 9300 Series Robotic Cleaner

SUBMERSIBLE SUMP PUMPS

EEDF & EEDF

SUBMERSIBLE SUMP PUMPS

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

In this kit there should be: 1 x Engine Case Cover (ECC0085) 2 x M6x28mm long button head bolts PLEASE READ THESE INSTRUCTIONS FULLY BEFORE STARTING

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

AUTOMATIC SUBMERSIBLE UTILITY PUMP

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

MOONRING 1.5 MOONRING 3

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

Wet Rated Batten LED Luminaire

CSD Series Current Devices Split Core

Matala. VersiFlow Series. Instruction and Maintenance Manual

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

INSTALLATION INSTRUCTION Magnetic Transformer

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800)

Have a Bright Day! Nicholas Harmon President, Verilux, Inc.

FITTING INSTRUCTIONS FOR RSET12BK ADJUSTABLE REARSETS FOR TRIUMPH DAYTONA 675 ( )

HydraPump Submersible Owner s Guide

EEDF & EEDF

R185A STRAIGHT JACK EZ FIT TYPE. 1 5/8" CORRUGATED CABLE Series : ECO 7/16 TECHNICAL DATA SHEET 1 / 5 MATERIALS. PLATING (µm) COMPONENTS

OWNER'S MANUAL WARNING DANGER. Propane cylinders sold separately. The propane cylinder must be disconnected when this firebowl is not use.

Fan Relay Board (FRBii) Assembly

INSTALLATION & OPERATION MANUAL

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

Electric Vehicle Charging Station

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

INSTALLATION INSTRUCTION Bollard Light 12V

Owner s Manual Drill and Light Weight Portable Utility Pumps

Jandy FloPro (FHP) Series Pump Parts Replacement Kit Instructions

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

Model (Circuit Tester) Model (GFCI Tester)

CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440

EV-2051-M Electric Motor. Operation and Maintenance Manual

SUBMERSIBLE MINI-PUMP

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

SUBMERSIBLE POND PUMP

TM-11x1 Series Room Temperature Module

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

GeyserMax-Flow Series

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

INSTALLATION GUIDE AND USER MANUAL

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

LEV/Wn Building A Connected World

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

M Remote Mounting Kit

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

Specification Grade Contemporary Wall Mount/Technical Installation Data

INSTRUCTION BOOK FOR. Dual Masking Electrol

Fitting Instructions for SRG0034 Radiator Guard Radiator Guard KAWASAKI VERSYS

FITTING INSTRUCTIONS FOR CP0404BL/WH NO-CUT AERO CRASH PROTECTORS HUSQVARNA 701 ENDURO/SUPERMOTO 2016-

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

GETTING STARTED WITH IN-WALL DIMMER SWITCH

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

GARDEN HOSE UTILITY PUMP

ESE Series Cast Iron Sewage Pumps

"Engineered to Ride, Built to Last "

Operating Manual Includes Pumps: PG-9000 Part #R809606

AquaLuminator Light and Return Water Flow for Above Ground Pools Owner's Manual

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

Instructions 3A4793B EN. See page 3 for a complete list of model descriptions and part numbers.

WARNING. Important Notice

SUBMERSIBLE SWIMMING POOL DRAINER

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

poollux Power plx-pw60 & plx-pw100

MODEL H INSTALLATION INSTRUCTIONS

Checker Unload Checkstand Installation Instructions

PRE-PLUMBED SEWAGE SYSTEM

Source Capture Air Purification System

SUPER PUMP OUT SYSTEM

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

Owner s Manual Guide du propriétaire

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

"Engineered to Ride, Built to Last "

M Remote Mounting Kit

Operation Care Service

2-WAY REMOTE STARTING SYSTEM WITH 1 BUTTONS FOR AUTOMATIC TRANSMISSION RED301-2WAY / ANT-2WDSS. User Guide For Key

INSTALLATION BLIND SPOT TURN SIGNAL MIRRORS 1457

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité

MC-CRX. Bill Acceptor Card Reader Combo. Operation & Service Manual

WARNING / AVERTISSEMENT

TABLE OF CONTENTS. Page 1

Warranty, Safety and Operating Instructions. Neptun 1600, /08B

VA-4233-AGx Series Electric Valve Actuators

INSTRUCTION BOOK FOR. Tensioned Dual Masking Electrol

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

Transcription:

Diagnostic Test Kit for Polaris Robotic Cleaners 93 94 95 Series P825 91 Series WARNING H0510700 Rev A The Diagnostic Box and included test cables are to be used solely for diagnosing Polaris Robotic Cleaners. It must not be used for any other purpose. Diagnostic tests must be performed while the unit is out of the water. Failure to comply with the following warnings can result in property damage, personal injury, or death. FOR YOUR SAFETY - This product must be serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exists. In the event no such state or local requirement exists, the installer or maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation will void the warranty. Improper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage, or death. Only connect unit to receptacle protected by a ground fault circuit interrupter (GFCI). Such a GFCI receptacle should be provided by a qualified installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this product. Disconnect the cleaner and have the problem corrected by a qualified service representative before using. KEEP OUT OF REACH OF CHILDREN

OVERVIEW 1.1 Diagnostic Kit Components... 3 1.2 Optional Test Cable for 91 Series Cleaners... 4 1.3 Required for Testing... 4 1.4 Testing Strategy... 4 1.5 Diagnostic Box Display Panel... 5 1.6 Control Box Diagnostic Test Status and Diagnostic Messages... 5 1.7 Cleaner / Motor Block Diagnostic Tests Status and Diagnostic Messages... 6 93 94 95 SERIES 2.0 Test for 9300 / P93 / 9300xi / 9350 / P935 (93 Series) 9400 / P94 / 9450 / P945 (94 Series) 9550 / P955 (95 Series)... 7 2.1 Perform Control Box Test... 7 2.2 Perform Cleaner Test... 7 2.3 Perform Test for Defective Motor Block... 8 2.4 93 94 95 Series Control Box Test... 10 2.5 93 94 95 Series Cleaner Test... 11 2.6 93 94 95 Series Motor Block Test... 12 P825 3.0 Test for P825 Cleaner... 13 3.1 Perform Control Box Test... 13 3.2 Perform Cleaner Test... 13 3.3 Perform Test for Defective Motor Block... 14 3.4 P825 Control Box Test... 17 3.5 P825 Cleaner Test... 18 3.6 P825 Motor Block Test... 19 91 SERIES 4.0 Test for 9100 / P91 Cleaner... 21 4.1 Perform Cleaner Test... 21 4.2 Perform Test for Defective Motor Block or Floating Cable... 21 4.3 91 Series Cleaner Test... 23 WARNING Make sure the plug is easily accessible at all times. Only connect the Control Box to a power outlet protected by a 30 ma maximum ground fault circuit interrupter (GFCI). If in doubt contact a qualified electrician. To reduce the risk of electrical shock, do not use the cleaner or Control Box if the cord is worn or damaged. Contact your local Polaris dealer immediately for a replacement cord. Double insulation For continued protection against possible electric shock, use only identical replacement parts when servicing. Do not attempt repair of the cleaner, Control Box, power cord, or Floating Cable. All repairs should be made by an experienced service professional using only Polaris OEM parts. NEVER OPEN Control Box. NEVER OPEN THE MOTOR BLOCK. The Control Box must not be installed in a floodable area. Do not use an extension cord to connect the unit to electric supply; provide a properly located outlet. The Control Box should be placed near the outlet box. WARNING To reduce the risk of injury, do not permit children to operate this product. Do not let anyone, especially small children, sit, step, lean, or climb on any equipment installed as part of your pool s operational system. SAVE THESE INSTRUCTIONS

Page 3 1.0 Overview This document provides diagnostic testing instructions for the following Polaris robotic cleaners: 93 Series: 9300 / P93 / 9300xi / 9350 / P935 94 Series: 9400 / P94 / 9450 / P945 95 Series: 9550 / P955 P825 91 Series: 9100 / P91 (test cable for 91 Series diagnostic available separately, see Section 1.2) The diagnostic test kit is supplied with four (4) test cables and a cord organizer, which can be mounted: GREEN 93 94 95 SERIES. Connects Diagnostic Box to cleaner Control Box. 4 Prongs Male 4 Prongs Male GREEN Test Cable Connectors BLUE P825. Connects Diagnostic Box to cleaner Control Box. 4 Prongs Male 3 Prongs Male OVERVIEW These instructions must be followed exactly. Not following the written procedure or taking shortcuts may increase the risk of personal injury. Read all instructions completely before starting the procedure. 1.1 Diagnostic Kit Components BLUE Test Cable Connectors GREY P825. Connects Diagnostic Box to cleaner power cable. 4 Prongs Male 3 Prongs Female GREY Test Cable Connectors BROWN ALL except 91 SERIES. Connects Diagnostic Box to Motor Block. Diagnostic Box 4 Prongs Male BROWN Test Cable Connectors USB Plug (for future software updates) NOTE: All test cables are also available for order as individual replacement parts from your Polaris supplier. Test Cable Set Cord Organizer

Page 4 OVERVIEW 1.2 Optional Test Cable for 91 Series Cleaners Contact your dealer or www.polarispool.com for optional test cable for 91 Series cleaners. Ask for part number: R0704900. Optional RED Test Cable P/N R0704900 1.4 Testing Strategy The Diagnostic Box should be used to test for errors or malfunctions in the following cleaner components in this order: 1. Control Box 2. Cleaner and Floating Cable 3. Motor Block NOTE: Steps for connecting the cleaner and testing each component are different for each robotic cleaner series. For complete step by step procedures, refer to the specific cleaner section in this manual. 4 Prongs Male 4 Prongs Female RED Test Cable Connectors CAUTION Do not touch the cleaner or any Diagnostic Box buttons while the test is running. NOTE: To test the motor block for 91 SERIES cleaners, you will also need to use a spare power cord. 91 SERIES cleaners can only be tested for cleaner errors using the Diagnostic Box with the RED test cable. 1.3 Required for Testing The consumer must provide the following items to perform the diagnostic testing: Control Box Cleaner Head with Floating Cable

Page 5 1.5 Diagnostic Box Display Panel Select Control Box Test Select CleanerTest Start Selected Test Testing Progress Bar Testing Status Message Clear Message or Cancel Testing OVERVIEW 1.6 Control Box Diagnostic Test Status and Diagnostic Messages Connect the correct test cable between the Diagnostic Box and the cleaner Control Box. On the Diagnostic Box, press [EBOX] button, then press [START] button. Control Box Progress Bar Message During Test Diagnostic Message Action Required Quick Test auto testing test fail-at check connections and run test again (replace Diagnostic Box if second fail) power supply test fail replace Control Box test keyboard test test fail replace Control Box test complete end good perform cleaner diagnostic test

Page 6 OVERVIEW 1.7 Cleaner / Motor Block Diagnostic Tests Status and Diagnostic Messages Set the cleaner on its back with wheels unobstructed. Connect the correct cable between the Diagnostic Box and the cleaner. On the Diagnostic Box, press [CLEANER] button, then press [START] button. Control Box Progress Bar Message During Test Diagnostic Message Action Required Quick Test system check test check connections and run test again auto testing test fail-at check connections and run test again (replace Diagnostic Box if second fail) communication test fail-com check connections and run test again (if second fail, dissassemble cleaner and test the motor block and the Floating Cable) traction motor tfd1 fail-trac replace with functioning traction forward drive 1 motor block and retest tfd2 traction forward drive 2 tbd1 traction backward drive 1 tbd2 traction backward drive 2 tck fail-trac traction clockwise tcc traction counter clockwise pump motor Pon pump on Poff pump off test complete end end replace with functioning motor block and retest replace with functioning motor block and retest

Page 7 2.0 Test for 93 Series (9300 / P93 / 9300xi / 9350 / P935) 94 Series (9400 / P94 / 9450 / P945) 95 Series (9550 / P955) 2.1 Perform Control Box Test 1. Plug the consumer s Control Box into a GFCI protected outlet. 2. Plug the Diagnostic Box into a GFCI protected outlet. 3. Connect one end of the GREEN test cable to the cleaner Control Box. 4. Connect the other end of the GREEN test cable to the Diagnostic Box. 2.2 Perform Cleaner Test 1. Set the cleaner head on a block of wood or some object that allows the cleaner wheels to rotate freely. 2. Make sure the Diagnostic Box is plugged into a GFCI protected outlet. 3. Connect the Floating Cable from the cleaner directly into the Diagnostic Box. 4. On the Diagnostic Box, press [CLEANER] button then Start/Stop button to begin the test. 5. The drive motor starts and the Diagnostic Box displays test progress (see Section 1.7). The wheels should turn during this part of the test. 6. The pump motor will turn on and off. The Diagnostic Box displays the test status and progress message (see Section 1.7). 7. If the cycle completes and the Diagnostic Box displays the message: End, the floating cable and cleaner pass the test and are fully functional. 8. If there is an error message on the Diagnostic Box display, see Section 2.5 Control Box Test for explanation and action. 93 94 95 SERIES 5. On the Diagnostic Box, press [EBOX] button then Start/Stop button to begin the test. The Diagnostic Box displays the test status and progress message (see Section 1.6). 6. The propeller motor will turn on for approximately three to fi ve (3-5) seconds. 7. If the test completes and the Diagnostic Box displays the message: good, the cleaner Control Box is fully functional. Turn off the power to the Control Box and disconnect. 8. If there is an error message on the Diagnostic Box display, see Section 2.4 Control Box Diagnostic Test for explanation. Control Box and repeat the test.

Page 8 2.3 Perform Test for Defective Motor Block 1. Unplug the cleaner. 2. Open the cleaner top and remove the filter canister. Remove the screw securing the propeller guard and remove propeller guard. 93 94 95 SERIES 3. Remove the propeller and the flow director by pushing out toward rear of cleaner housing. Remove the four (4) Motor Block Screws 6. Disconnect the Floating Cable from the motor block by removing two (2) screws connecting the cable to the block. Pull the plug away from the block to remove. NOTE You will have one of the following motor block cable plugs: Remove the Propeller Guard Integral Seal Plug Remove the Propeller and Flow Director 4. Close the cover, turn cleaner over and place on a soft surface so that it is resting on its top. 5. Remove four (4) screws from the bottom of the cleaner. Remove the bottom plate/motor block. NOTE When removing the motor block, ensure the drive gears and drive pins are on the drive shafts. O-Ring Plug (Take care not to lose or remove the O-ring)

Page 9 Remove the Floating Cable 7. Connect one end of the BROWN test cable into the motor block. 8. Connect the other end of the BROWN test cable into the Diagnostic Box. 9. On the Diagnostic Box, press [CLEANER] button then Start/Stop button to begin the test. The drive gears will rotate on the drive shaft for approximately ten (10) seconds then stop. The Diagnostic Box displays the test status and progress message (see Section 1.7). 10. If the cycle completes and the Diagnostic Box displays the message: End, the Motor Block is functional and the Floating Cable should be replaced. 11. If there is an error message on the Diagnostic Box display, see Section 2.6 Motor Block Test for explanation and action. 12. If the test results in a Fail error message, replace with a new motor block. 93 94 95 SERIES NOTE Return all defective component(s) to Polaris. (For more information, go to www.polarispool.com.)

Page 10 2.4 93 94 95 Series Control Box Test Dia6 1. Brancher Plug in Diagnostic le coffret Box 2. Brancher Plug in Cleaner la diag Control box Box 3. Connect the Control Box to Connecter le coffret à la the Diagnostic Box using the GREEN diag box test avec cable. l adaptateur vert 93 94 95 SERIES test Appuyer sur «Press Start/Stop» or ou [] «or [CANCEL]» ou «Cancel» Appuyer sur «Press Ebox [EBOX]» puis «then Start/Stop» Disconnect / Reconnect Débrancher/rebrancher Diag Box la diag box Appuyer sur «Press Ebox [EBOX]» puis «then Start/Stop» Débrancher/ Disconnect / rebrancher Reconnect l ensemble Control Box coffret/ and Diag Box diagbox Appuyer sur «Press Ebox [EBOX]» puis then Start/Stop Contact Changer Polaris Customer Service diagbox Changer le coffret Control Box Fail 6ood END Fin Débrancher/rebrancher Disconnect / Reconnect l ensemble coffret/ Control Box diagbox Appuyer sur «Press Ebox [EBOX]» puis then Start/Stop Fail Changer le Control Box coffret

Page 11 2.5 93 94 95 Series Cleaner Test Dia6 1. Brancher Plug la diag in Diagnostic box Box Connecter le robot à la diag 2. box (avec Connect l adaptateur the gris Cleaner DIRECTLY to the pour le CyclonX) Diagnostic Box. Press Start/ test Appuyer sur «Start/ stop Stop» ou or «[]» ou «Cancel» or [CANCEL] Appuyer Press sur «[CLEANER] Cleaner» puis then Start/Stop Disconnect Débrancher/ / Reconnect rebrancher la diagbox Diag Box Appuyer Press sur «[CLEANER] Cleaner» puis Test «Start/Stop effectué» then Start/ * ** Check the cable Vérifier dans le connecteur côté câble que les fils sont connections. correctement branchés Press Appuyer sur Cleaner puis [CLEANER] then Start/Stop Débrancher/rebrancher l ensemble robot/ diagbox Press Appuyer [CLEANER] sur «Cleaner» puis then Start/Stop *** Disconnect / Reconnect Control Box and Diag Box Not Bloc pas Tester le the bloc Motor moteur Block Bloc Changer le câble du Floating robot Cable Changer le bloc Motor moteur Block 93 94 95 SERIES t fd t bd tcl Tcc P on Poff SERIES Famille Vortex 93 94 uniquement 95 only Forward Traction Motor Moteur traction marche avant Moteur Backward traction Traction marche arrière Motor Testing Clockwise Test rotation droite Rotation Testing rotation Counter Clockwise gauche Démarrage Start Pump du moteur pompe Motor Test Stop Pump Motor Test Arrêt du moteur pompe Contact Polaris Customer Service Changer la diagbox Fail- trac ** Fail- pump ** See explanation reporter à description for du same error message above. See reporter explanation à description for du same error message above. 1. Débrancher Unplug the le robot cleaner et and dissassemble. brancher le bloc moteur à 2. la Connect diagbox à l aide the Motor du Block to the Diag box using the connecteur BROWN marron test cable. Appuyer Press sur «[CLEANER] Cleaner» puis» Start/Stop» then Start/ Changer le bloc Motor moteur Block NOTE: After replacing with functioning Motor Block test again. If FAIL, replace the Floating Cable. Check that the floating cable is connected correctly. Vérifier dans le connecteur côté câble que les fils sont correctement branchés Débrancher Disconnect le bloc the Motor Block moteur et rebrancher and connect le robot the Cleaner to the à la diagboxdiag Box Press Appuyer sur Cleaner puis [CLEANER] then Start/Stop Changer le câble Floating Cable NOTE: If Motor Block test reaches END with no Fail messages, replace the Floating Cable. End END Fin Fail- At See explanation for *Se reporter à la description du same défaut error en haut message du logigramme above. 1. Unplug the Cleaner. 2. Dissassemble Cleaner to access the Motor Block. 3. Connect the Motor Block to the Diag Box using the BROWN test cable. Tester le the bloc moteur Motor Block Bloc not pas Bloc Problem with transmission Problème and/or sur la impeller transmission et/ ou l hélice Changer le système de Vérifier Check le système the de transmission et/ou nettoyer transmission et l hélice transmission les débris de l hélice and/or clean debris from the impeller Vérification impeller transmission and the Changer le bloc Motor moteur Block

Page 12 2.6 93 94 95 Series Motor Block Test Dia6 1. Plug Brancher in Diagnostic la diag box Box 2. Connecter Connect le bloc the moteur Motor Block à la diag to the Diagnostic box Box avec using l adaptateur the BROWN marron test cable. Test Appuyer Press sur «Cleaner [CLEANER]» puis then * Replace Changer the le Motor bloc moteur Block 93 94 95 SERIES ** *** Débrancher/ Disconnect / Disconnect Débrancher/ / rebrancher Reconnect la Reconnect rebrancher Motor l ensemble Diag diagbox Box Block bloc moteur/diagbox and Diag Box Appuyer Press sur Appuyer Press sur «Cleaner [CLEANER]» puis «Cleaner [CLEANER]» puis then Replace Changer the la Diag diagbox Box Replace Changer the le bloc Motor moteur Block Tfd Moteur Forward traction Traction marche avant Motor Tbd Moteur Backward traction marche Traction arrière Motor tcl Testing rotation Clockwise Rotation droite Appuyer sur «Start/stop Press Start/» ou Stop «or»[] ou or «[CANCEL] Cancel» Testing Counter tcc Test rotation Clockwise gauche Rotation SERIES Famille Vortex 93 94 uniquement 95 only Pon Démarrage Start Pump du moteur Motor Test pompe Fail- trac See explanation for same error message above. *Se reporter à la description du *** Se Changer Replace le the bloc Motor moteur Block *Se reporter à la description du *** Se See reporter explanation à description for du same error message above. See explanation for same error message above. See reporter explanation à description for du same error message above. Poff Arrêt Stop du Pump moteur Motor pompe Test Fail- pump Fail- At * * Changer Replace le the bloc Motor moteur Block See reporter explanation à description for du same error message above. End END Fin

Page 13 3.0 Test for P825 Cleaner 3.1 Perform Control Box Test 1. Plug the consumer s Control Box into a GFCI protected outlet. 2. Plug the Diagnostic Box into a GFCI protected outlet. 3. Connect the colored end of the BLUE test cable to the Diagnostic Box. 4. Connect the other end of the BLUE test cable to the cleaner Control Box. 3.2 Perform Cleaner Test 1. Set the cleaner head on a block of wood or some object that allows the cleaner tracks to rotate freely. 2. Make sure the Diagnostic Box is plugged into a GFCI protected outlet. 3. Connect the colored end of the GREY test cable to the Diagnostic Box. 4. Connect the other end of the GREY test cable to the Floating Cable from the cleaner. 5. On the Diagnostic Box, press [EBOX] button then Start/Stop button to begin the test. 6. If the cycle completes and the Diagnostic Box displays the message: good, the cleaner Control Box is fully functional. Turn off the power to the Control Box and disconnect. 7. If there is an error message on the Diagnostic Box display, see Section 3.4 Control Box Test for explanation. Control Box and repeat the test. 5. On the Diagnostic Box, press [CLEANER] button then Start/Stop button to begin the test. 6. The drive motor will start and the Diagnostic Box displays the test progress. The tracks should be moving during this part of the test. 7. The pump motor will turn on and off and the Diagnostic Box displays the test progress. 8. If the cycle completes and the Diagnostic Box displays the message: End, the floating cable and cleaner pass the test and are fully functional. 9. If there is an error message on the Diagnostic Box display, see Section 3.5 Cleaner Test for explanation and action. P825

Page 14 3.3 Perform Test for Defective Motor Block 1. Unplug the cleaner. 2. Remove the filter canister. Unscrew the impeller housing and remove impeller. 5. Pry wheel keys from each side of the brush and remove the brush. P825 6. Remove two (2) screws on each side of the cleaner body and remove body housings. 3. Remove four (4) screws inside the canister at the handle brackets. 4. Remove four (4) screws from the bottom of the canister bowl.

Page 15 7. Turn the cleaner over, remove two (2) screws and take off the bottom plate. 10. Remove screws and detach the Floating Cable. 8. Turn the cleaner back over and gently pull the gear box off the handle mount. Repeat both sides and remove the gear box and the handle together. 11. Connect one end of the BROWN test cable into the motor block. P825 9. Remove the canister bowl to free the motor block. 12. Connect one end of the BROWN test cable into the motor block. 13. Connect the other end of the BROWN test cable into the Diagnostic Box. 14. On the Diagnostic Box, press [CLEANER] button then Start/Stop button to begin the test. The drive gears will rotate on the drive shaft for approximately ten (10) seconds then stop. The Diagnostic Box displays the test status and progress message (see Section 1.7). 15. If the cycle completes and the Diagnostic Box displays the message: End, the Motor Block is functional and the Floating Cable should be replaced.

Page 16 11. If there is an error message on the Diagnostic Box display, see Section 3.6 Motor Block Test for explanation and action. 12. If the test results in a Fail error message, replace with a new motor block. NOTE Return all defective component(s) to Polaris. (For more information, go to www.polarispool.com.) P825

Page 17 3.4 P825 Control Box Test Dia6 Brancher le coffret 1. Brancher Plug in Diagnostic la diag Box box 2. Plug in Cleaner Control Box Connecter le coffret à la diag 3. Connect the Control Box to box avec the Diagnostic l adaptateur Box using bleu the BLUE test cable. test Appuyer Press [EBOX] sur then «Ebox» Start/Stop puis «Start/Stop» Disconnect / Reconnect Débrancher/rebrancher Diag Box la diag box Débrancher/ Disconnect / rebrancher Reconnect l ensemble Control Box coffret/ and Diag Box diagbox Appuyer sur «Press Start/Stop» or ou [] «or [CANCEL]» ou «Cancel» Appuyer Press [EBOX] sur «Ebox» then Start/Stop puis «Start/Stop» Appuyer Press [EBOX] sur «Ebox» then Start/Stop puis «Start/Stop» Contact Changer Polaris la Customer Service diagbox Changer Control le Box coffret P825 Fail 6ood END Fin Disconnect / Débrancher/rebrancher Reconnect l ensemble Control Box coffret/ and diagbox Diag Box Appuyer Press [EBOX] sur «then Ebox Start/Stop» puis Test Fail Changer le Control coffret Box

Page 18 3.5 P825 Cleaner Test Dia6 1. Brancher Plug la diag in Diagnostic box Box Connecter le robot à la diag 2. box (avec Connect l adaptateur the gris Cleaner to the Diagnostic pour le CyclonX) Box using the GREY test cable. test Press Appuyer [CLEANER] sur «Cleaner» puis then Start/Stop * Check the cable Vérifier dans le connecteur côté câble que les fils sont connections. correctement branchés Press Appuyer sur Cleaner puis [CLEANER] then Start/Stop Not Bloc pas Tester le the bloc Motor moteur Block Bloc Changer le bloc Motor moteur Block Changer le câble du Floating robot Cable ** *** Disconnect Débrancher/ / Reconnect rebrancher la diagbox Diag Box Disconnect / Reconnect Control Box and Diag Box Débrancher/rebrancher l ensemble robot/ diagbox Press Start/ Appuyer sur «Start/ stop Stop» ou or «[]» ou «Cancel» or [CANCEL] Appuyer Press sur «[CLEANER] Cleaner» puis Test «Start/Stop effectué» then Start/ Press Appuyer [CLEANER] sur «Cleaner then Start/Stop» puis P825 Contact Polaris Customer Service Changer la diagbox 1. Débrancher Unplug the le robot cleaner et and dissassemble to access the Motor Block. brancher le bloc moteur à 2. la Connect diagbox à l aide the Motor du Block to the Diag box using the BROWN test cable. connecteur marron Press Appuyer [CLEANER] sur «then Cleaner Start/Stop» puis» Start/Stop» t fd t bd tcl Tcc SERIES Famille Vortex 93 94 uniquement 95 only P on Poff Forward Traction Motor Moteur traction marche avant Moteur Backward traction Traction marche arrière Motor Testing Clockwise Test rotation droite Rotation Testing rotation Counter Clockwise gauche Rotation Démarrage Start Pump du moteur pompe Motor Test Stop Pump Motor Test Arrêt du moteur pompe Fail- trac ** Fail- pump ** See explanation reporter à description for du same error message above. See reporter explanation à description for du same error message above. Changer le bloc Motor moteur Block NOTE: After replacing with functioning Motor Block test again. If FAIL, replace the Floating Cable. Vérifier dans le connecteur Check that the floating cable is côté câble que les fils sont correctement connected branchés correctly. Débrancher Disconnect le bloc the Motor Block moteur et rebrancher and connect le robot the Cleaner to the à la diagboxdiag Box Press Appuyer sur Cleaner puis [CLEANER] then Start/Stop Changer le câble Floating Cable NOTE: If Motor Block test reaches END with no Fail messages, replace the Floating Cable. End END Fin Fail- At See explanation for *Se reporter à la description du same défaut error en haut message du logigramme above. 1. Unplug the Cleaner. 2. Dissassemble Cleaner to access the Motor Block. 3. Connect the Motor Block to the Diag Box using the BROWN test cable. Problem with transmission and/or impeller Problème sur la transmission et/ Bloc ou l hélice Changer le système de Tester le the bloc Check Vérifier the le système transmission de transmission transmission et/ou nettoyer moteur transmission et l hélice and the impeller and/or les débris clean de debris l hélice from the impeller Bloc not pas Vérification Motor Block Changer le bloc Motor moteur Block

Page 19 3.6 P825 Motor Block Test Dia6 1. Plug Brancher in Diagnostic la diag box Box 2. Connecter Connect le bloc the moteur Motor Block à la diag to the Diagnostic box Box avec using l adaptateur the BROWN marron test cable. Test Appuyer Press sur «Cleaner [CLEANER]» puis then * Replace Changer the le Motor bloc moteur Block ** *** Débrancher/ Disconnect / Disconnect Débrancher/ / rebrancher Reconnect la Reconnect rebrancher Motor l ensemble Diag diagbox Box Block bloc moteur/diagbox and Diag Box Appuyer Press sur «Cleaner [CLEANER]» puis Appuyer Press sur «Cleaner [CLEANER]» puis then Replace Changer the la Diag diagbox Box Replace Changer the le bloc Motor moteur Block Tfd Moteur Forward traction Traction marche avant Motor P825 Tbd Moteur Backward traction marche Traction arrière Motor tcl Testing rotation Clockwise Rotation droite Appuyer sur «Start/stop Press Start/» ou Stop «or»[] ou or «[CANCEL] Cancel» Testing Counter tcc Test rotation Clockwise gauche Rotation SERIES Famille Vortex 93 94 uniquement 95 only Pon Démarrage Start Pump du moteur Motor Test pompe Fail- trac See explanation for same error message above. *Se reporter à la description du *** Se Changer Replace le the bloc Motor moteur Block *Se reporter à la description du *** Se See reporter explanation à description for du same error message above. See explanation for same error message above. See reporter explanation à description for du same error message above. Poff Arrêt Stop du Pump moteur Motor pompe Test Fail- pump Fail- At * * Changer Replace le the bloc Motor moteur Block See reporter explanation à description for du same error message above. End END Fin

Page 20 NOTES P825

Page 21 4.0 Test for 9100 / P91 Cleaner 4.1 Perform Cleaner Test NOTE: You can only test the cleaner function on the 9100 and P91 with the Diagnostic Box. You cannot test the Control Box functionality. 1. Set the cleaner head on a block of wood or another solid object that allows the cleaner wheels to rotate freely. 2. Plug the Diagnostic Box into a GFCI protected outlet. 3. Connect the colored end of the RED test cable into the Diagnostic Box. NOTE: The RED cable does not come standard with the Diagnostic Box but is available for separate order (part number: R0704900). 4. Connect the other end of the RED test cable to the Floating Cable from the cleaner. 5. On the Diagnostic Box, press [CLEANER] button then Start/Stop button to begin the test. 6. Drive motors should start within a few seconds. Cleaner wheels will rotate for several seconds and stop automatically when the test is completed. 7. While wheels are moving, check for air flowing from the exhaust on the back of the cleaner. 8. If the cycle completes and the Diagnostic Box displays the message: End, the cleaner is fully functional. 9. If the wheels do not rotate or there is an error message on the Diagnostic Box display, see Section 4.3 Cleaner Test for explanation and action. 4.2 Perform Test for Defective Motor Block or Floating Cable NOTE: To test the motor block for 91 SERIES cleaners, you will also need a spare Floating Cable. 1. Determine if there is water damage to the O-ring or the cable receptacle. Remove four (4) screws from the handle on the cleaner. Remove the handle piece. P91 SERIES

Page 22 6. Check the O-ring for damage. 2. Remove three (3) screws from cable receptacle (see Figure 6). Remove the Floating Cable and receptacle. P91 SERIES 3. Check inside the receptacle for water damage. 4. Perform a complete visual inspection of the length of the entire Floating Cable for wear. 5. Check the power plug for any visible wear or water damage. 7. If there is no evidence of water damage to the O-ring, the cable receptacle, or the Floating Cable and power plug, the motor block is defective. Replace with a new motor block and repeat the test. NOTE Return defective component(s) to Polaris. (For more information, go to www.polarispool.com.)

Page 23 4.3 91 Series Cleaner Test Dia6 1. Brancher Plug in la Diagnostic diag box Box Connecter 2. Connect le robot the Cleaner à la to diag the Diagnostic Box using box avec l adaptateur rouge the RED test cable. Test Appuyer sur Press [CLEANER] «cleaner» puis then Start/Stop Appuyer sur «Start/ Press Start/Stop or [] or Stop» ou ou [CANCEL] «Cancel» Vérifier dans le Check the floating cable connecteur côté câble que connection. les fils sont correctement floating cable if the connection branchés. is Sinon good. changer le câble du robot Appuyer sur Press «Cleaner» [CLEANER] puis then Start/Stop «Start/ Stop» Changer le Motor Block bloc moteur Débrancher/ Disconnect / Reconnect rebrancher la Diag Box diagbox Appuyer sur Press [CLEANER] «Cleaner» puis Test then effectué Start/Stop Vérifier Verify que the le moteur Motor Runs tourne NOTE: The 9100 and P91 Control Box cannot be tested using the Diagnostic Box. Not Pas Contact Polaris Changer la Customer diagbox Service Changer Replace le thebloc Motor Block moteur END Fin End P91 SERIES

Zodiac Pool Systems, Inc. 2620 Commerce Way, Vista, CA 92081 1.800.822.7933 www.zodiacpoolsystems.com Zodiac Pool Systems Canada, Inc. 2115 South Service Road West, Unit 3 Oakville, ON L6L 5W2 Canada 1.888.647.4004 www.zodiacpoolsystems.ca ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license. All trademarks referenced herein are the property of their respective owners. ZODIAC est une marque déposée de Zodiac International, S.A.S.U., utilisée sous licence. Toutes les marques de commerce et marques déposées susmentionnées dans le présent document sont la propriété de leurs propriétaires respectifs. ZODIAC es una marca registrada de Zodiac International, S.A.S.U., utilizada bajo licencia. Todas las marcas registradas mencionadas en este documento son propiedad de sus respectivos propietarios. 2015 Zodiac Pool Systems, Inc. H0510700 Rev A