Energy Recovery Laboratory Exhaust

Similar documents
Energy Recovery Laboratory Exhaust

Laboratory Exhaust Systems

Laboratory Exhaust Systems

Laboratory Exhaust Systems

Laboratory Exhaust Systems. Vektor -H High Plume

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Tube Axial Inline Fans

Tubular Centrifugal Fans

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

XeteX, Inc. All Rights Reserved.

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

2. Backward inclined / backward curved centrifugal wheel fans. 3. Axial / backward curved mixed flow impeller bifurcated fans.

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Propeller Hooded Roof Fans

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data


Inline Fans [ 14 ] * UL is optional and must be specified.

HIGH VELOCITY FUME EXHAUST FANS

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

High Performance Axial Fans

High Performance Axial Fans

Complete HVAC Capability

Roof Upblast and Sidewall Exhaust

TUBULAR CENTRIFUGAL INLINE FANS

READ AND SAVE THESE INSTRUCTIONS

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

Roof Upblast and Sidewall Exhaust

Inline and Roof Mounted Fans

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Direct Gas-Fired Heating

Gravity Ventilators. Models FGI and FGR. Fabra Hood Intake and Relief

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators

LINEA Low Discharge Roof Exhausters

SDL Single-Duct, Low-Height, VAV Terminals

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

The highest energy recovery available.

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

QMXTubular Mixed Flow Product Guide 1

TSS Single-Duct VAV Terminals

Twin City Fan & Blower

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

Energy Recovery Ventilator

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

Filtered Kitchen Supply Packaged Ventilator

Mancoolers Models MCY, MCB, MCP

forward curved inline duct blowers

Hybrid Fans. Models QEI and QEID. Belt and Direct Drive

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

Mixed Flow Inline Fan, Model MFSI

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

PH SERIES SINGLE DUCT ATU PERFORMANCE DATA

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

Centrifugal Inline Fans

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

Climas y Proyectos Leyco, S.A. de C.V.

Belt Drive - Centrifugal Up-Blast Fans. Measurements. Motor Availability. HP Open 2 Speed Open 2 Speed. 1/4 na na na. 1/3 na na na 1/2 3/4 1 1/2.

CONSTRUCTION FEATURES AND OPTIONS

Air Measuring Products AMD AMS IAQ

Air Moving Solutions. low pressure mixed flow fans. QCLB QCLBR (Restaurant) QCLBSH (Smoke & Heat)

Industry best 5 year fan housing warranty, 1 year motor warranty

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

FN Fan-Coil Units High-Performance, Horizontal

Mixed Flow Inline Fan Model EQB

MODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER

BAC, BAF, BAH Central Station Air Handlers

Vane Axial Fans Models VAB and VAD. Belt and Direct Drive

Centrifugal Filtered Supply Roof Blowers

FAN POWERED TERMINAL UNITS

University of Delaware

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

Industry best 5 year fan housing warranty, 1 year motor warranty

VANEAXIAL & TUBEAXIAL FANS

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

FKUB Belt Drive - Centrifugal Up-Blast Fans

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

Propeller Upblast Roof Fans

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

FAN POWERED TERMINAL UNITS

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL

VAHU Vertical Air Handling Unit

The newest addition to RenewAire s broad line of Energy Recovery Ventilators.

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

TYPICAL SPECIFICATION: Critical Process Roof Top Unit 7/14/15

Transcription:

Energy Recovery Laboratory Exhaust Model Vektor ERS-M For Vektor-M Fan Systems September 2012

Model Page Header Vektor ERS-M Greenheck s Vektor -ERS is a pre-engineered laboratory exhaust energy recovery system. In combination with our Vektor-M high plume dilution blowers, this system is designed to effectively remove contaminated laboratory exhaust and dilute and disperse the exhaust high above the roof. Vektor energy recovery exhaust systems utilize run around coils to recover energy from the exhaust airstream and apply the energy to the make-up air system. Vektor ERS-M offers a safe and efficient solution to minimize the possibility of cross-contamination between exhaust and supply airstreams. Vektor ERS-M run around coil loops can achieve energy recovery efficiencies up to 50% to lower heating and cooling costs for the laboratory facility. id you know Laboratories typically require 100% outside air with ventilation rates ranging from 6 to 15 air changes per hour. ASHRAE 90.1 indicates that energy recovery to preconditioned make-up air is a suggested energy savings method for laboratories in excess of 15,000 cfm. NFPA 45 states only general exhaust can utilize airto-air energy recovery due to the potential of cross contamination, which is a violation of the standard. Vektor ERS-M utilizes air-to-liquid energy recovery, eliminating the possibility of cross-contamination and recovers more exhaust energy. Studies show that approximately 50% of the energy costs associated with operating a laboratory are the result of heating and cooling the makeup air. The addition of energy recovery can significantly reduce this cost. Model Vektor -M is listed for electrical (UL/cUL 705). File No. E40001 2 Type of Heat Transfer Run Around Coil Loop Specifications Sensible Sensible Effectiveness % Up to 50% Location of Exhaust/Supply Airstream Cross-Contamination Cross-Leakage Separate None None Temperature Range -45 to 200 F

Page Header Vektor ERS Features: Four pre-engineered energy recovery plenum sizes Heresite coated coils Insulated double-wall plenum with stainless steel interior Run around coil loop energy recovery Coil bypass option Physical separation between exhaust and supply Single source responsibility Vektor M Features: High plume, induced flow dilution blower Utilizes an efficient and quiet mixed flow impeller Bifurcated fan housing with motor, drive, and bearings located out of the airstream for safe, easy servicing AMCA 260 Licensed for Induced Flow Fans Single source responsibility Performance Ranges VKERS-020 Up to 24,000 cfm VKERS-030 12,500-28,750 cfm VKERS-040 17,000-41,200 cfm VKERS-060 30,000-66,000 cfm Applications University Laboratories Pharmaceutical Companies Biosafety Laboratories Research Facilities Any contaminated exhaust system where reducing energy cost is desired VKERS-040-075-M303 Model Name Cabinet Size 020, 030, 040, 060 Cabinet Height 75, 90, 110 Fan Type M Number of Fans 1, 2, 3 Fan Size 15 20 27 36 49 16 22 30 40 54 18 24 33 44 3

ERS Page System HeaderOperation The Vektor ERS uses a corrosion-resistant run around liquid coil loop to recover energy from the laboratory exhaust airstream and transfer the energy to the laboratory make-up air. The energy transfer preheats make-up air in the winter and precools make-up air in the summer. iluted High Plume Exhaust Reheat Coil Cooling Coil Vektor Energy Recovery Coil Filters Make-Up Air Unit Energy Recovery Coil Filters VAV Bypass Air Glycol Loop Pump Outside Air Supply Exhaust Safe, Reliable, Cost-Effective The run around coil loop is the preferred method of recovering energy from hazardous lab exhaust because separation is maintained between the exhaust and supply airstreams, eliminating the concern of crosscontamination. The exhaust coil is corrosion-resistant coated and in subfreezing climates, a percentage of glycol is added to depress the freezing point of the circulated fluid. The Vektor ERS system also eliminates the need to duct large volumes of supply and exhaust air to a common point which is required with other energy recovery systems reducing the Vektor ERS system installed cost and improving economic payback. Significant Energy Savings The Vektor ERS can significantly reduce a laboratory facility s heating and cooling load. The tables illustrate preheating and precooling temperatures of make-up air and load reductions for various cities based on standard weather bin data. Greenheck offers a complete thermodynamic and economic analysis of a Vektor ERS for your specific project. Winter / Preheated Summer / Precooled Outdoor Air Temperature ( F) -10 0 10 20 30 85 95 105 Preheat Air Temperature ( F) 26.9 32.4 37.9 43.4 48.9 79.2 84.7 90.2 Preconditioning of make-up air based upon 72 exhaust and 45% energy recovery efficiency. City BTUH Saved Annually Net ollars Saved Heating Cooling Annually Atlanta 7,556,153 (1,657,890) $42,303 Boston 8,927,100 (1,657,890) $77,779 Chicago 13,677,593 (1,657,890) $86,261 Cincinnati 13,794,495 (1,594,125) $75,385 Portland 3,528,330 (1,647,263) $59,063 Syracuse 9,458,475 (1,594,125) $90,887 Energy saving shown for annual operation, at outdoor TMY2 bin data for the specified location. Systems operating at 50,000 cfm, equal supply and exhaust; $0.1/kWh, and $1.75/MMBtu, assuming 80% heating efficiency. NOTE: kwh and MMBtu costs may vary by locale. 4

imensions, Page HeaderWeights and Configurations Bypass Air Inlet (typical) for VAV Systems E C B Inlet Horizontal Airflow A (Length) B (Width) C Weight** (pounds) Fan Section Height* Coil Section Height* Maximum Minimum Maximum Minimum Maximum 75 90 110 VKERS-020 120 133 153 70 70 3564 4386 NA VKERS-030 154 127 181 70 84 4042 4644 NA 75 90 110 VKERS-040 206 147 181 70 84 5117 5824 NA VKERS-060 270 147 181 70 84 6609 7515 8001 E Overall System Height Fan Size 15 16 18 20 22 24 27 30 33 36 40 44 49 54 Minimum 145 147 161 174 169 177 193 202 194 201 209 225 240 250 Maximum 145 161 175 188 183 191 207 216 208 215 223 239 254 264 imensions shown in inches. * = Curb not included ** = Approximate weight based on maximum coil size and maximum number of filters. Fans, bypass plenums and roof curbs are not included. Obtain from CAPS (Computer Aided Product Selection). Available Configurations A A Inlet Vertical Airflow B 1x1 2x1 3x1 Vektor M Selections by Cabinet Size Bypass Air Inlet (typical) for VAV Systems 1x1 2x1 3x1 VKERS-020 VK-M 15-36 VK-M 15-22 Not available VKERS-030 VK-M 20-44 VK-M 15-33 VK-M 15-22 VKERS-040 VK-M 24-50 VK-M 24-54 VK-M 20-27 VKERS-060 VK-M 40-54 VK-M 30-54 VK-M 24-40 E Consult factory for additional configuration options. C B Inlet Horizontal Airflow 5

Vektor Page Header ERS Standard Construction Features A Cabinet Construction Coated steel exterior with stainless steel interior ouble-wall construction with two-inch foam filled panels Stainless steel fasteners Bottom or side inlet locations Hinged access door with tooled entry handles Optional coil bypass design B Coil Construction Aluminum fins with copper tubing, corrosion-resistant Heresite coated Stainless steel casing, corrosion-resistant Heresite coated Sized for maximum velocity of 500 ft/min Six row coils, eight fins per inch (standard) Rated in accordance with ARI 410-2001 UL and ETL recognized Leak tested under water at 450 PSIG dry nitrogen E C Filters Two-inch up to 35% disposable pleated filters, MERV 8 (0.24 inch wg pressure drop at 500 ft/min) Four-inch up to 65% disposable pleated filters, MERV 11 (0.40 inch wg pressure drop at 500 ft/min) G Fan Plenum Curb 12 gauge welded steel, coated with LabCoat Insulated Minimum of 12 inches high Gasket provided for curb seal esigned to withstand 125 mph wind-load rating without the use of guy wires G Vektor Sure-Aire another energy saving system from Greenheck Continuously monitor critical laboratory fan exhaust and building exhaust flow without airflow probes in the exhaust airstream. Benefits of the Sure-Aire system: Continuously measures critical fan and laboratory exhaust flow Reports values to Building Automation System (BAS) No system effect or resistance to airflow No additional pressure loss No increase in fan RPM, sound or brake horsepower No additional energy cost for the building owner No probe corrosion to cause fan failure 6 Fan Flow Measurements Bypass Airflow Measurements Output to BAS

Page Header E Fan Construction Efficient and quiet mixed flow impeller technology Bifurcated housing with motor, belt and bearings out of the airstream Corrosion-resistant welded steel construction, coated with LabCoat Belt or direct drive Totally enclosed fan cooled, premium efficient motors F Fan Plenum Construction Single or double-wall construction Exterior steel walls coated with LabCoat Interior walls available in stainless or coated steel with LabCoat F A B C G amper Features Isolation damper completely accessible from exterior of system Bypass damper(s) are sized to match system requirements Corrosion-resistant polyester resin coated, welded steel airfoil blade design H H Coil Cabinet Curb 12 gauge corrosion-resistant welded steel, coated with LabCoat Insulated Minimum of 12 inches high Gasket provided for curb seal esigned to withstand 125 mph wind-load rating without the use of guy wires Vektor ERS Options and Accessories Magnehelic Gauge To measure air pressure drop across the filters indicating filter loading. Vapor Tight Lights Moisture and corrosion-resistant construction with no exposed parts. Energy-efficient, compact fluorescent lamps. 7

Vektor Products Vektor-H Vektor-HS Vektor-H Vektor-HS Housing Style Inline Centrifugal Inline Centrifugal Stack Style High Plume Nozzle High Plume Variable Nozzle Minimum Flow 270 cfm (459 m ³ /hr) 270 cfm (459 m ³ /hr) Maximum Flow 24,000 cfm (40,776 m ³ /hr) 24,000 cfm (40,776 m ³ /hr) Maximum ESP Up to 3.5 in. wg (875 Pa) Up to 3.5 in. wg (875 Pa) Underwriters Laboratories AMCA Certification UL/cUL Listed for Electrical 705 (File no. 40001) and UL Listed for Grease Removal 762 Power Ventilators for Restaurant Exhaust Appliances (File no. MH11745) Sound and Air Performance - UL/cUL Listed for Electrical 705 (File no. 40001) Warranty 1 Year 1 Year Patents Patent Pending Vektor-M Other Patents Pending Vektor-C Vektor-M Vektor-C Housing Style Inline Mixed Flow Centrifugal Stack Style High Plume ilution Nozzle High Plume ilution Nozzle Minimum Flow 1,500 cfm (2,549 m ³ /hr) 500 cfm (850 m ³ /hr) Maximum Flow 80,000 cfm (135,921 m ³ /hr) 140,000 cfm (237,862 m ³ /hr) Maximum ESP Up to 8 in. wg (2000 Pa) Up to 14 in. wg (3500 Pa) Underwriters Laboratories AMCA Certification UL/cUL Listed for Electrical 705 (File no. 40001) Induced Flow Fan Air and Sound Performance UL/cUL Listed for Electrical 705 (File no. 40001) Induced Flow Fan Air and Sound Performance Warranty 1 or 3 Years 1 Year Patents United States: 7320636, 7682231, 7048499 Singapore: 124135, 124106 Mexico: 258949, 243465 P.R. China: 20058006160.6, 01813109.3 Hong Kong: 1114659 United States: 7547249 Singapore: 124105 Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties. Prepared to Support Green Building Efforts P.O. Box 410 Schofield, WI 54476-0410 Phone (715) 359-6171 greenheck.com 00.LAB.1009 R4 9-2012 RG Copyright 2012 Greenheck Fan Corp.