HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Similar documents
PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Plate mounted axial flow fans HXBR / HXTR Series

COMPACT Series type HCFB / HCFT (Plastic impellers)

supplied in Form (B) configuration. Airflow over Impeller- Motor.

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

Short casing. Long casing (L version) Commercial premises

CENTRIFUGAL IN-LINE FANS VENT Series

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

ACOUSTIC CABINET FANS CVAB / CVAT Series

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

CGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

DIRECT-AIR ILB / ILT Series Rectangular duct fans

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

ACOUSTIC CABINET FANS CVB / CVT Series

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

TGT Series Adjustable Pitch Fans

IN-LINE CENTRIFUGAL DUCT FANS VT Series

TGT Series Adjustable Pitch Fans

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

CHMT Series, F Rated Fans

Sabre Plate Mounted Sickle Fans (VSP)

Performance. Sound Levels. Impellers. Motors. Accessories

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Axial fans. What s more, non-stock models are normally available within two weeks.

MIXVENT-TH Series Mixed Flow Fans

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

Multifunctional 400ºC/2h and 300ºC/2h roof fans

Sabre Sickle Fan Assisted Roof Cowls (VSR)

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

Vent-Axia Sabre Sickle Roof Fans (VSR)

BELT DRIVEN CABINET FANS CVTT Series

TD-ECOWATT AND DECOR-ECOWATT Series

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

Acoustic Twin Fans (ATQ)

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

Square Mixed Flow Fans (MFQ)

CVHT Series - F rated cabinet fans

WINDER. Impellers with higher efficiency and less sound level

NEW Acoustic In-Line Fans (ACQ)

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

NEW WINDER. Impellers with higher efficiency and less sound level

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

BATHROOM EXTRACT FANS DECOR-100 Series

AC Commercial Fans Edition. ErP ready

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

Centrifugal medium-pressure fans fitted with multi-blade

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

Section 4 e c tio - P lat F a n s

CYLINDRICAL CASED AXIAL FLOW FANS

Max. airflow m 3 /s Diam. min. Diam. max

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Hison Axial Flow Fans

Mixed Flow Roof Fans (RMH)

Hison Axial Flow Fans

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

NEW Slimpak EC Box Fan (SLPT EC)

Uniclass L7534. Manufacture controlled to ISO9001

SILENT MV Ultra Quiet In-line Fans

Mixed Flow Roof Fans (RMH)

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

AXIAL FLOW CABINET FAN CGT Series

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

TD-SILENT Series (160 to 1000 models)

HIGH-POWERED VENTILATORS

AXIAL FANS Catalogue CN0050C01 May 2008

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

CMP-L/EW B T D. Industrial Brushless Motors E.C. Motor power (CV) Three-phase VSD 400 V50/60 Hz. electrical power Maximum.

Bifurcated Case Axial Fans (BIFA)

CK, LPK, LPKB. Duct fans with circular connection.

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

High-efficiency long-cased axial fans fitted industrial Brushless motor E.C. Fibreglass-reinforced plastic impeller.

CJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation

400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

GigaBox centrifugal fans Product specific information

Transcription:

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series 0 017982 603075 A P P L I C A T I O N S Range of plate mounted axial fans manufactured from high grade galvanised steel and provided with a Sickle blade impeller. The motor and fan impeller are supported within this mounting plate by strong electrowelded steel support frame. All models include a steel finger guard as standard mounted to the inlet side of the fan. The whole fan assembly is protected against corrosion by cataforesis primer and a polyester black paint finish (1). Available, depending upon the model, with single or three phase motors in 2, 4, 6, 8 or 12 poles (1) Models 800, 910 and 1000, fitted as standard with not painted motor-impeller. Motors All the motors are IP54, Class F insulation, equipped with thermal protection. Electrical supplies: Single phase 230V-50Hz. (Capacitor located inside the wiring terminal box). Three phase 400V-50Hz. (250 model: 230/400V-50Hz). All single phase models are speed controllable excepted 630 and 710 models. All three phase models are speed controllable by Autotransformer. Models from Ø800 to Ø1000 are speed controllable by inverter. Additional Information Standard air direction: form (A) configuration (Motor over Impeller). Warehouses Workshops Commercial premises Car parks Agricultural applications All models are supplied with a pre-wired wiring junction box located on the back of the motor hub for easy access wiring. On request Greenhouses Painting Installations Conditioning groups Air conditioning Air direction: form (B) configuration (Impeller over Motor). Three phase motors 230/400V-50Hz. Compact design Corrosion resistance Terminal box High efficiency Sickle blade impeller This very low profile design optimises airflow performances whilst minimising noise generation Mounting plate, motor support and finger proof guard protected by cataforesis primer and black polyester paint finish. Stainless steel screws Wiring terminal box with cable gland PG-11 (M20: from 800 to 1000 models) Sickle Blade impeller specifically designed to ensure the highest and most efficient airflow performance with the lowest noise level. Dynamically balanced to ISO 1940 standard. Manufactured from aluminium plate, except from 250 to 355 models which are manufactured from pressed sheet steel 72

Technical characteristics Before making any electrical connection ensure that the voltage and frequency of the mains electrical supply matches that of the fan data plate label. Protection Operating temperature range Speed Maximum power absorbed Maximum absorbed current Sound pressure level Max. air volume Weight Model Voltage IP Mínima Máxima (r.p.m.) (W) a 230 V a 400 V db (A) (m 3 /h) (kg) SINGLE PHASE 2 POLES HXBR/2-250 230V 50Hz IP 54-40 C +60 C 2650 120 0,55 58 1650 7,0 SINGLE PHASE 4 POLES HXBR/4-250 230V 50Hz IP 54-40 C +60 C 1450 40 0,21 45 930 6,5 HXBR/4-315 230V 50Hz IP 54-40 C +40 C 1400 120 0,53 53 2074 7,0 HXBR/4-355 230V 50Hz IP 54-40 C +60 C 1400 120 0,55 59 2970 7,5 HXBR/4-400 230V 50Hz IP 54-40 C +70 C 1360 290 1,20 60 5080 9,0 HXBR/4-450 230V 50Hz IP 54-40 C +70 C 1370 380 2,00 64 7649 11,5 HXBR/4-500 230V 50Hz IP 54-40 C +70 C 1350 850 3,80 69 9957 16,0 HXBR/4-560 230V 50Hz IP 54-40 C +40 C 1300 1300 6,00 70 12460 21,5 HXBR/4-630 230V 50Hz IP 54-40 C +40 C 1200 1300 5,70 72 14518 24,0 SINGLE PHASE 6 POLES HXBR/6-400 230V 50Hz IP 54-40 C +70 C 890 150 0,29 51 3387 9,0 HXBR/6-450 230V 50Hz IP 54-40 C +70 C 880 210 1,00 55 5099 11,5 HXBR/6-500 230V 50Hz IP 54-40 C +70 C 870 310 1,30 60 6638 16,0 HXBR/6-560 230V 50Hz IP 54-40 C +70 C 820 410 1,80 61 8307 21,5 HXBR/6-630 230V 50Hz IP 54-40 C +70 C 830 700 3,10 63 12315 24,0 HXBR/6-710 230V 50Hz IP 54-40 C +70 C 860 900 4,00 66 16668 27,0 THREE PHASE 2 POLES HXTR/2-250 230/400V 50 Hz IP 54-40 C +60 C 2700 110 0,40 0,23 57 1650 7,0 THREE PHASE 4 POLES HXTR/4-250 230/400V 50 Hz IP 54-40 C +60 C 1450 50 0,35 0,20 46 930 6,5 HXTR/4-315 400V 50Hz IP 54-40 C +70 C 1420 130 0,46 53 2074 7,0 HXTR/4-355 400V 50Hz IP 54-40 C +70 C 1400 150 0,42 59 2970 7,5 HXTR/4-400 400V 50Hz IP 54-40 C +70 C 1340 300 0,80 60 5080 9,0 HXTR/4-450 400V 50Hz IP 54-40 C +70 C 1340 570 1,10 64 7649 11,5 HXTR/4-500 400V 50Hz IP 54-40 C +70 C 1370 970 1,90 69 9957 16,0 HXTR/4-560 400V 50Hz IP 54-40 C +70 C 1340 1400 2,50 70 12460 21,5 HXTR/4-630 400V 50Hz IP 54-40 C +70 C 1330 1400 2,50 73 14518 24,0 THREE PHASE 6 POLES HXTR/6-400 400V 50Hz IP 54-40 C +70 C 900 170 0,50 51 3387 9,0 HXTR/6-450 400V 50Hz IP 54-40 C +70 C 910 230 0,57 55 5099 11,5 HXTR/6-500 400V 50Hz IP 54-40 C +70 C 900 270 0,62 60 6638 16,0 HXTR/6-560 400V 50Hz IP 54-40 C +70 C 860 450 0,90 61 8307 21,5 HXTR/6-630 400V 50Hz IP 54-40 C +70 C 880 740 1,50 63 12315 24,0 HXTR/6-710 400V 50Hz IP 54-40 C +70 C 920 1000 2,60 66 16668 27,0 HXTR/6-800 400 V 50Hz IP54-40 C +70 C 895 1700 3,4 67 25800 46 THREE PHASE 8 POLES HXTR/8-800 400 V 50Hz IP54-40 C +70 C 638 690 1,43 60 19090 45 THREE PHASE 12 POLES HXTR/12-800 400 V 50Hz IP54-40 C +70 C 445 280 0,76 51 12640 43 HXTR/12-910 400 V 50Hz IP54-40 C +70 C 435 680 1,68 55 20600 55 HXTR/12-1000 400 V 50Hz IP54-40 C +50 C 420 890 2,2 56 26000 61 73

Acoustic characteristics The sound levels NPS- shown in the technical characteristic chart, correspond to the value of sound pressure db(a), measured in free field conditions at a distance equivalent to three times the diameter of the impeller with a minimum of 1.5 meters. Sound power level spectrum in db(a) at the corresponding octave band average frequencies in Hz. Mounting accessories " LwA ASP Q max. 63 125 250 500 1000 2000 4000 8000 2-250 47 45 55 61 66 68 66 59 4-250 34 31 42 48 53 55 53 46 4-315 38 50 53 62 62 62 57 47 4-355 37 54 58 67 70 68 62 52 4-400 39 56 62 66 70 70 65 58 4-450 42 59 66 70 73 74 69 62 4-500 42 64 71 76 81 76 70 60 4-560 51 64 71 80 80 78 74 65 4-630 54 68 74 81 83 80 74 66 6-400 30 47 53 57 60 61 56 49 6-450 33 50 57 61 64 65 60 53 6-500 33 55 61 66 72 67 60 50 6-560 42 55 62 71 71 69 65 56 6-630 45 59 65 72 74 70 65 57 6-710 48 61 68 75 76 73 67 59 6-710 48 61 68 75 76 73 67 59 6-800 52 67 66 69 72 73 70 64 12-1000 52 56 64 62 65 61 59 53 Model Wire Exhaust side Louvre shutters guard Plastic Aluminium 250 DEF-250 D PER-250 W PER-250 CN 315 DEF-325 D PER-355 W PER-355 CN 355 DEF-375 D PER-355 W PER-355 CN 400 DEF-450 D PER-400 W PER-400 CN 450 DEF-450 D PER-450 W PER-450 CN 500 DEF-525 D PER-500 W PER-500 CN 560 DEF-630 D PER-560 W PER-630 CN 630 DEF-630 D PER-630 W PER-630 CN 710 DEF-800 D PER-710 W PER-710 CN 800 DEF-800 D PER-800 W PER-800 CN 1000 DEF-1000 D PER-1000 W PER-1000 CN Electrical accessories REB-1N / REB 2,5N Electronic, single phase speed controllers REB-5 Electronic single phase speed controller RMB / RMT Single and three phase auto- transformer speed controllers REB-4 Auto REB-5 Auto Electronic single phase speed controllers with temperature sensor. For agricultural applications 74

Dimensions (mm) SINGLE PHASE THREE PHASE A B C D D1 D2 E F HT J K L M Single phase Three phase Single Three Single Three Model /2 /4 /6 /2 /4 /6 phase phase phase phase 250 315 260 220 250 261 290 10 10,5 0-10,5 0-126 126 33 53 12 73 73 315 400 330 280 315 320 365 10-0 - - 0-149 149 41 68 12 82 82 355 450 380 315 355 363 411 10-0 - - 0-156 156 41 75 12 82 82 400 500 420 355 400 410 464 10-12 - - 0-200 176 92 78 12 122 97 450 560 480 400 450 457 522 10-0 0-0 0 204 179 68 91 12 114 89 500 630 560 450 500 512 572 10-13 0-13 0 201 176 60 97 12 104 79 560 710 630 510 559 570 649 10-20 0-20 0 213 188 70 99 12 114 89 630 800 710 580 630 640 730 12-25 25-25 7 207 182 60 103 12 104 79 710 900 800 637 710 810 12 - - 11 - - 11 221 206 115 92 17 130 115 Model a d p b r q s t u HXTR/6-800 788 205 960 797 17 170 910 970 14,5 HXTR/8-800 788 188 960 797 17 170 910 970 14,5 HXTR/12-800 788 165 960 797 17 170 910 970 14,5 HXTR/12-910 905 205 1115 914 22 210 1010 1070 14,5 HXTR/12-1000 990 205 1140 1000 22 210 1110 1170 14,5 75

Performance curves Q = Air volume in, m 3 /hr and m 3 /s. Pe = Static pressure in mmwg and Pa. Dry air at 20ºC and 760 mmhg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985. Typical fan selection: Do not select the working point in the coloured area. To find the working point first it is necessary to plot the system resistance curve. The working point lies at the intersection between that curve and the curve of the fan. Example: Required air volume 10.000 m 3 /h at 3 mmwg. Working point 11.300 m 3 /h at 4 mmwg. HXBR/2-250 HXTR/2-250 Pa mmwg Do Not Select a Fan with a Working Point in this Area Required Air Volume HXBR/4-560 HXTR/4-560 HXBR/4-250 HXTR/4-250 System Resistance Curve Working Point of Fan HXBR/4-315 HXTR/4-315 HXBR/4-355 HXTR/4-355 76

Performance curves Q = Air volume in, m 3 /hr and m 3 /s. Pe = Static pressure in mmwg and Pa. Dry air at 20ºC and 760 mmhg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985. HXBR/4-400 HXTR/4-400 HXBR/4-450 HXTR/4-450 HXBR/6-400 HXTR/6-400 HXBR/6-450 HXTR/6-450 HXBR/4-500 HXTR/4-500 HXBR/6-500 HXTR/6-500 77

Performance curves Q = Air volume in, m 3 /hr and m 3 /s. Pe = Static pressure in mmwg and Pa. Dry air at 20ºC and 760 mmhg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985. HXBR/4-560 HXTR/4-560 HXBR/4-630 HXTR/4-630 HXBR/6-560 HXTR/6-560 HXBR/6-630 HXTR/6-630 Pa mmwg HXBR/6-710 HXTR/6-710 78

Performance curves Q = Air volume in, m 3 /hr and m 3 /s. Pe = Static pressure in mmwg and Pa. Dry air at 20ºC and 760 mmhg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985. HXTR/6-800 HXTR/12-800 HXTR/8-800 HXTR/12-910 Pa mmwg HXTR/12-1000 79