Soler & Palau. Research Design and High Technology

Similar documents
Introducción Introduction

BSB. Single Inlet Centrifugal Fan. with Backward Wheels

Soler & Palau. Research Design and High Technology

ADA. Double Inlet Centrifugal Fan. with Airfoil Impellers

BDB. Double Inlet Centrifugal Fan. with Backward Wheels

FDA Double Inlet Centrifugal Fan. with Forward Wheels

FDA. Double Inlet Centrifugal Fan. with Forward Wheels

BSB SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

ASA. SINGLE INLET CENTRIFUGAL FAN with Airfoil Wheels

BPF. Centrifugal Plug Fans

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

BDB DIDW CENTRIFUGAL FAN with Backward Wheel TYPE X TYPE T

BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

AXIAL FANS Catalogue CN0050C01 May 2008

Unobox units with backward curved centrifugal impellers

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

Shhhhhhhhhhh! Here there is silence.

Centrifugal Fans belt driven. TD_CFB-RDY_EN Issue 1.1 EN July 2013

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

WINDER. Impellers with higher efficiency and less sound level

TDF Double Inlet Backward Curve Centrifugal Fans

BNA. PLENUM FAN with Backward Wheels

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

TURNING AIR INTO SOLUTIONS. HIGH EFFICIENCY INDUSTRIAL BACKWARD CURVED FANS MODEL HIB

CHMT Series, F Rated Fans

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

CONSTRUCTION FEATURES AND OPTIONS

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

Vibration Isolators (6) Galvanized Wheel. Sealed Ball Bearing. Standard Duct Size Inlet Ring

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

CENTRIFUGAL FANS. Single Width, Single Inlet WFS & WBS Series WTC TECH CO., LTD. CENTRIFUGAL FANS Single Width, Single Inlet WFS & WBS Series

Mixed Flow Inline Fan, Model MFSI

Centrifugal Fans RZR belt driven. Issue 2.5 EN August 2013

Roof Upblast and Sidewall Exhaust

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

SECTION AXIAL HVAC FANS

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

BACKWARD INCLINED FANS

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

Mancoolers Models MCY, MCB, MCP

Centrimaster GX Catalogue GX Rev.01. January 2009

series Silencers

Centrifugal Fans ADH belt driven. Issue 2.5 EN August 2013

Centrimaster GX. Catalogue GX Rev.03 October 2012

Novenco axial flow fans. ZerAx - Standard January 2010

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

LINEA Low Discharge Roof Exhausters

ROOFMASTER STEF-HT ROOF FAN

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

VERANTIS. FRP Fans: CMHB Series Performance and Technical Information. Environmental Solutions Group

MVF S.r.l. Via San Giovanni Bosco, Alessandria Tel Fax Web:

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

SECTION CENTRIFUGAL HVAC FANS

SECTION HVAC POWER VENTILATORS

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

Industrial Material Handler Page Introduction... 2 Information Specifications MH Specifications... 6 MHR Specifications...

NEW WINDER. Impellers with higher efficiency and less sound level

Axial fans. What s more, non-stock models are normally available within two weeks.

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

SQUARE INLINE CENTRIFUGAL FANS

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

Centrifugal Spun Aluminum Products

DESIGN GUIDELINES FANS PAGE 1 of 7

FRP Fans: CLUB Series Performance and Technical Information

Good Enough Never Is. Plug Fan SERIES 12

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

Centrifugal Upblast Power Roof Ventilators

DIRECT-AIR ILB / ILT Series Rectangular duct fans

BACKWARD INCLINED fans

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index

DUCT-M HT F400/2h. Smoke exhaust ducted axial fan APPLICATIONS TECHNICAL SPECIFICATIONS VERSIONS ACCESSORIES ON REQUEST. May 2018 Catalog N 000 Rev.

MAJAX-2 GENERAL SPECIFICATION

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

Roof Upblast and Sidewall Exhaust

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

Multifunctional 400ºC/2h and 300ºC/2h roof fans

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

CENTREX INLINER Centrifugal Inline Fans

Performance. Sound Levels. Impellers. Motors. Accessories

Industry best 5 year fan housing warranty, 1 year motor warranty

Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Transcription:

Research Design and High Technology Soler & Palau Sales Department C/ Llevant, 4 Polígono Industrial Llevant 08150 Parets del Vallès (Barcelona) - SPAIN Tel. +34935719420 ax +34935719421 e-mail: oem.info@solerpalau.com Web: http://www.solerpalau.com

Single Inlet Centrifugal an with Backward Wheels

Introducción Introduction S&P - LA EMPRESA Desde su fundación en el año 1951, en la localidad de Ripoll (España), Soler & Palau, S.A. se ha convertido, desde hace ya bastantes años, en uno de los líderes mundiales en la fabricación y venta de todo tipo de equipos de ventilación y de extracción de aire. Ocho plantas productivas y once empresas filiales propias de comercialización, ubicadas en diversos países y continentes constituyen el actual Grupo S&P que, con un cualificado equipo de más de 1300 personas, ejerce su actividad en todos los países del mundo. S&P - THE COMPANY Soler & Palau was founded in 1951 in Ripoll (Spain) and since this date has become one of the world s leading companies engaged in the manufacture, sales and distribution of all types of ventilating and air moving products. Today Soler & Palau has eight production plants and eleven wholly owned commercial subsidiary companies located across the globe. Supporting the design, development production and commercial facilities are a professional team of more than 1300 employees who ensure that Soler & Palau continue to have an active presence in all global market sectors. S&P - LA ESTRATEGIA Investigación y Desarrollo de productos y tecnología propios; Calidad de producción por encima de la media de su campo de actividad y Vocación de Expansión sostenible son, y han sido entre otros, tres de los pilares fundamentales sobre los que descansa la trayectoria de Soler & Palau, S.A. Contar hoy con más de 60 Ingenieros titulados en las áreas de Investigación, Desarrollo, Innovación y Producción; Certificaciones ISO 9001:2000 y 14001:1996 acrediatadas por AENOR (Soler & Palau fue la primera empresa registr en España). Laboratorios propios de ensayo con certificación oficial EN-45001-89 y crecimientos anuales, sostenidos en las últimas décadas, muy superiores a los de su mercado son algunos de los logros de la correcta aplicación de la mencion estrategia de empresa. Nuevos y apasionantes proyectos que verán la luz muy en breve, están hoy en marcha en el Grupo S&P. S&P - THE STRATEGY At the heart of Soler & Palau s company strategy is the continued substantial investment in product and manufacturing research, development and quality control. Since 1951 the sustained investment in these critical areas has enabled Soler & Palau to offer to its customers products with unparalleled quality and reliability. These critical elements of success today form the fundamental cornerstones of the company s strategy for growth within increasingly competitive global markets. Today Soler & Palau has more than 60 highly qualified engineers working in areas such as product and manufacturing technology research, development, innovation and production. The engineers work closely with international safety standards agencies to ensure that all of Soler & Palau s products are manufactured and supplied in accordance with only the very latest mechanical and electrical safety standards. All products are extensively tested with the company s comprehensive in-house airflow, acoustic and environmental test laboratories which have been officially certified by AENOR to EN-45001-89 standards. Currently Soler & Palau hold both ISO 9001:2000 and ISO 14001:1996 certifications and were also the first company in Spain to be registered to the original ISO 9000 standards. Through operating a continual rigorous program of new and existing product development and improvement means that Soler & Palau s customers are assured that they will continue to receive products of only the very highest quality and reliability both now and in the future. 2

Soler & Palau S.A. certifies that the series shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA publication 211 and AMCA publication 311 and comply with the requirements of the AMCA Certified Ratings Program. SINGLE INLET CENTRIUGAL AN with Backward Wheels

Single Inlet Centrifugal ans Backward wheels The series is SISW centrifugal fans with high efficiency non-overloading backward curved impellers. The fans are suitable for supply or exhaust applications in commercial and industrial buildings. Sizes of this series are in accordance with AMCA standard 99-0098-76 and DIN 323 R20. Type / Operating Limit Model 315 to 630 Type C-U I Model 710 to 1.000 Type T-U II I Type X-U III II Type Z-U III Each fan type has its maximum operating speed and power due to its mechanical design. The operating limit of series - fan type is design to meet the requirement of class I, II and III limit as defined in AMCA standard 99-2408-69. The series is available in type C, T, X, Z or U. Type C This type has a frame fitted on both sides of the fan which gives better strength and rigidity. It allows mounting in four different orientations. an size 315 to 630 Volume 1.500 to 20.000 m 3 /h Total Pressure up to 2.000 Pa Type T This type has a welded frame giving increased stiffness and rigidity required for higher operating performance. an size 315 to 1.400 Volume 1.500 to 100.000 m 3 /h Total Pressure up to 3.000 Pa Type X/Z This structure is similar to Type T but utilizes enhanced bearings to support higher dynamic load necessary for the increased performance. Type Z is non-standard, for more information, please consult your nearest Kruger office for detail. an size 315 to 1.400 Volume 1.500 to 100.000 m 3 /h Total Pressure up to 5.000 Pa Type U This type is manufactured with a special frame with two bearings fixed externally to the airflow eliminating any obstruction to the inlet and allow operation with air temperature up to max. of 180 C. an size 315 to 1.400 Volume 1.500 to 100.000 m 3 /h Total Pressure up to 5.000 Pa 4

Technical Specification Wheel The wheel of series has backward curved blades manufactured in cold rolled sheet steel with polyester powder coating finish. Housing or all sizes except 1250 and above, the housing is manufactured in galvanized sheet steel with the housing fixed to the side plates in pittsburg lock form system. Housing for 1250 and 1400 are manufactured in mild steel finished with polyester powder coating. ully welded steel plate housings with painted finish are available for all sizes upon request. rame The frame is manufactured with galvanized angular bars for type C. or type T, X and U, they are manufactured with sections of steel and finished with polyester powder coating. Shaft Shafts are manufactured from C45 carbon steel using an automatic process for positioning and cutting of the keyways. All dimensional tolerances of the shaft are fully checked to ensure a precision fit and then coated with an anticorrosion varnish after assembly. Bearings Bearings used are either deep groove ball bearing type with an adapter sleeve, or spherical roller bearings type sealed at both sides for different duty application classified as below: Mounted in a rubber housing Mounted on cast iron supports with grease point C T X U an Type CM Medium Duty TM Medium Duty XM Medium Duty UM Medium Duty Bearing Duty eg. Model 450 C M TX Extra Heavy Duty XX Extra Heavy Duty UX Extra Heavy Duty 450 C M an Bearing Duty (L, M, X) an Type (S, C, T, X, Z) an Size (315, 355, 400,...1400) 5

The bearings are lubricated for life and maintenance-free except for TX, XX, UX extra heavy duty bearings. If re-lubrication is necessary, it is recommended to use a lithium base grease suitable for all temperatures within the operational limits. or type P bearing, please consult your nearest S&P office for detail. Balancing Quality All wheels are statically and dynamically balanced to ISO1940 and AMCA 204 G2.5 standards. Accessories Casing Drain This option is available when using fans exposed to the atmosphere or operating in high humidity conditions. Outlet langes Outlet flanges are available upon request. Inlet langes This option are set against the fan to facilitate installation. It is available in 2 types- L flange or U flange. Inspection Doors The inspection door can be supplied upon request. It can be supplied in one of the three positions (P3, P4 & P5). Guards Inlet guard, discharge guards and non-drive end shaft guards are available on request. Paintings Special powder-paint coatings of various thicknesses can be supplied on request. P3 P4 P5 6

an Rotation and Discharge The rotation and discharge of the fan is in accordance with AMCA standard 99-2406-83. The direction of rotation is determined from the drive side of the fan: CW - clockwise rotation CCW - counter-clockwise rotation 90º 180º 270º 360º CW CCW Motor Position The position of the motor for belt drive centrifugal fan is in accordance with AMCA standard 99-2407-66. Location of motor is determined by facing the drive side of fan and designating the positions by letters W, X, Y, or Z. Reprinted from AMCA Standard 99-2407-03, Motor Positions for Belt Chain Drive Centrifugal ans, with the express written permission from the Air Movement and Control Association International, Inc., 30 West 4 University Drive, Arlington Heights, IL 60004-1983. 100 80 Motor Selection The power curve shown on each performance curve represents the absorbed power at the shaft of the fan measured in kw. To determine the power of the motor to be installed, a correction factors should be applied to compensate for transmission losses. Correction actor, % motor power output 60 40 30 20 15 10 8 6 4 3 2 1.5 2 Pole 4 & 6 Pole 1 0.2 0.3 0.45 0.6 0.75 1.5 2.2 3 4.5 6 7.5 15 22.5 30 45 60 75 150 225 300 450 Motor power output (kw) 7

Dynamic Pressure The dynamic pressure and outlet air velocity shown on each curve are both calculated on the full air discharge area, i.e. ducted outlet conditions. With free outlet conditions the velocity pressure is higher. To determine this new value, multiply the velocity pressure of the ducted outlet obtained from the fan curve by the following correction factor K. [ K 1.67 ] an Performances calculated with this correction factors are not licensed by AMCA. Performance The performance data shown on each diagram has been tested and measured in accordance to AMCA Standard 210 [ig 12] installation type B (free inlet and ducted outlet condition). Rating are referred to the standard air density with the total pressure as a function of the air volume, using logarithmic scales. It is essential that, the same installation type and test standards are used at all times, when comparing fan performances. Noise The noise level shown on each diagram refer to the sound power A-weighted and the data on the inlet side has been tested and measured in accordance with AMCA Standard 300 diag. 2 - configuration B. The noise levels of the fans are determined as follows: Sound power level - ( A scale): Lw (A) as catalogue. Octave band spectrum: Lw Lw(A) + Lw rel. db [refer to Soler & Palau for more details]. Sound pressure level: a) free field Lp(A) Lw(A) - (20log 10 d) -11 b) room conditions Lp(A) Lw(A) - (20log 10 d) -7 where d distance of fan (m) 8

Example of Selection 560 Op Limit Type M. kw M. RPM Cl. I C-U 6 1800 Cl. II T-U 13 2300 Cl. III X-U 26 2900 Air Volume Q 6660 m 3 /h Outlet Velocity Dynamic Pressure Total Pressure an Speed V 6.77 m/s Pd 27 Pa Pt 1250 Pa N 1510 rpm Absorbed Power W 3.22 kw Total Efficiency 71.8 % Sound Power Level Lw(A) 81.3 db(a) - Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kw does not include drive losses. - The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted outlet. Ratings do not include the effect of duct end corrections. 9

315 Pt [Pa] 6000 5000 kw Op Limit Cl. I Cl. II Cl. III Type C U T U X U M.kW 2.5 5 10 M.RPM 3200 4200 5300 1.22 kg/m3 48 56 65 70 64 55 41 6 8 5 4000 4 3000 3 N [rpm] 2 2000 1.6 1.2 1 5300 0.8 4800 1000 0.6 0.5 105 4500 4200 0.4 3800 0.3 100 3450 500 400 0.16 0.12 0.2 95 3200 3000 2800 2600 300 90 2400 2200 200 70 85 2000 1800 80 1600 100 Lw (A) [db(a)] 75 1400.2.3.4.5.6.8 1 2 3 4 5 6 Q [m3/s] 500 1000 2000 3000 5000 10000 20000 2 3 4 5 6 8 10 20 30 40 50 60 80 1 5 10 50 100 500 1000 Q [m3/h] V [m/s] Pd [Pa] - Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kw does not include drive losses. - The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted outlet. Ratings do not include the effect of duct end corrections. 10

355 - Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kw does not include drive losses. - The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted outlet. Ratings do not include the effect of duct end corrections. 11

400 - Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kw does not include drive losses. - The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted outlet. Ratings do not include the effect of duct end corrections. 12

450 - Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kw does not include drive losses. - The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted outlet. Ratings do not include the effect of duct end corrections. 13

500 - Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kw does not include drive losses. - The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted outlet. Ratings do not include the effect of duct end corrections. 14

560 - Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kw does not include drive losses. - The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted outlet. Ratings do not include the effect of duct end corrections. 15

630 - Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kw does not include drive losses. - The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted outlet. Ratings do not include the effect of duct end corrections. 16

710 - Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kw does not include drive losses. - The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted outlet. Ratings do not include the effect of duct end corrections. 17

800 - Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kw does not include drive losses. - The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted outlet. Ratings do not include the effect of duct end corrections. 18

900 - Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kw does not include drive losses. - The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted outlet. Ratings do not include the effect of duct end corrections. 19

1000 - Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kw does not include drive losses. - The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted outlet. Ratings do not include the effect of duct end corrections. 20

1120 - Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kw does not include drive losses. - The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted outlet. Ratings do not include the effect of duct end corrections. 21

1250 - Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kw does not include drive losses. - The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted outlet. Ratings do not include the effect of duct end corrections. 22

1400 - Performance shown is for Installation type B - free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating kw does not include drive losses. - The A-weighted sound ratings shown have been calculated per AMCA standard 301. Values shown are for inlet Lwi(A) sound power levels for installation type B - free inlet, ducted outlet. Ratings do not include the effect of duct end corrections. 23

C 315-400 C R G B M L N X A D C S Y V t1 t z Ød-h7 w P H uxs E J K Model A B C D E G H J K L M N P R S V X Y t t1 w z ød uxs 315 578 518 340 404 223 330 236 480 253 283 451 78 279 38 3 460 319 251 432 8 7 40 28 25 13x18 355 654 578 383 452 247 368 260 548 287 327 479 72 303 30 6 508 359 275 480 8 7 40 33 30 13x18 400 736 650 432 506 274 402 290 612 314 354 506 72 330 38 5 562 404 302 534 8 7 40 33 30 13x18 All Dimensions in mm. 450-630 C R G B M L N X t A D C 1 S Y V t1 z Ød-h7 w P 1 H uxs E J K Model A B C D E 1 G H J K L M N P R S V X Y t t1 w z ød uxs 450 827 726 486 568 308 200 111 322 681 348 388 556 88 364 45 5 624 454 336 596 10 8 50 38 35 13x18 500 918 800 538 638 345 245 120 352 750 385 425 593 88 401 50 5 694 504 373 666 10 8 50 38 35 13x18 560 1030 892 603 714 383 280 125 390 844 433 483 653 100 439 48 7 770 564 411 742 12 8 70 43 40 13x18 630 1157 998 679 800 433 328 110 434 945 483 533 703 100 489 53 6 856 634 461 828 12 8 70 43 40 13x18 All Dimensions in mm. 24

T 315-400 T R G B M L N X t A S D C Y t1 z Ød-h 7 V V1 V2 w P ux s H E J K Model A B C D E G H J K L M N P R S V V1 V2 X Y t t1 w z ød uxs 315 578 518 340 404 223 330 236 480 253 283 451 78 279 38 3 460 315 356 395 251 432 8 7 40 28 25 13x18 355 654 578 383 452 247 368 260 548 287 327 481 74 303 30 6 508 355 395 435 275 480 8 7 40 33 30 13x18 400 736 650 432 506 274 402 290 612 314 354 508 74 330 38 5 562 400 438 480 302 534 8 7 40 33 30 13x18 All Dimensions in mm. 450-1000 T R G B M L N X t A D C 1 S Y V V1 V2 t1 z Ød -h7 w P 1 H ux s E J K Model A B C D E 1 G H J K L M N P R S V V1 V2 X Y t t1 w z ød uxs 450 827 726 486 568 308 200 111 322 681 348 388 564 96 364 45 5 624 450 487 530 336 596 10 8 50 38 35 13x18 500 918 800 538 638 345 245 120 352 750 385 425 601 96 401 50 5 694 500 541 580 373 666 10 8 50 38 35 13x18 560 1030 892 603 714 383 280 125 390 844 433 483 661 108 439 48 7 770 560 605 646 411 742 12 8 70 43 40 13x18 630 1157 998 679 800 433 328 110 434 945 483 533 711 108 489 53 6 856 630 674 716 461 828 12 8 70 43 40 13x18 710 1302 1120 765 898 479 360 150 484 1057 529 579 763 114 535 63 7 954 710 751 796 507 926 14 9 70 48.5 45 17x22 800 1468 1254 862 1006 533 405 171 540 1180 583 633 817 114 589 74 7 1062 800 837 886 561 1034 14 9 70 48.5 45 17x22 900 1648 1408 971 1130 595 455 189 604 1319 645 695 906 141 651 89 7 1186 900 934 986 623 1158 16 10 90 59 55 17x22 1000 1810 1540 1066 1266 663 500 200 656 1450 713 763 974 141 719 90 9 1322 1000 1043 1086 691 1294 16 10 90 59 55 17x22 All Dimensions in mm. 25

T 1120-1400 T N X R L G B M t D A S Y C Ød-h7 V V1 V2 z t1 w P H uxs E J K Model A B C D E G H J K L M N P R S V V1 V2 X Y t t1 w z ød uxs 1120 2033 1725 1200 1422 744 290 748 1630 804 870 1146 133 800 95 9 1478 1120 1180 1226 772 1450 18 11 90 64 60 17x22 1250 2285 1930 1353 1524 803 300 830 1831 878 953 1232 148 859 99 9 1580 1250 1303 1358 831 1552 18 11 110 69 65 17x22 1400 2568 2170 1515 1794 934 310 963 2057 1009 1084 1381 166 990 113 13 1850 1400 1480 1506 962 1822 20 12 110 74.5 70 17x22 All Dimensions in mm. 26

X 315-400 X R G B M L N X t A S D C Y t1 z Ød-h 7 V V1 V2 w P ux s H E J K Model A B C D E G H J K L M N P R S V V1 V2 X Y t t1 w z ød uxs 315 578 518 340 404 223 330 236 480 253 283 457 84 279 38 3 460 315 356 395 251 432 8 7 40 33 30 13x18 355 654 578 383 452 247 368 260 548 287 327 503 96 303 30 6 508 355 395 435 275 480 10 8 50 38 35 13x18 400 736 650 432 506 274 402 290 612 314 354 530 96 330 38 5 562 400 438 480 302 534 10 8 50 38 35 13x18 All Dimensions in mm. 450-1000 X R G B M L N X t A D C 1 S Y V V1 V2 t1 z Ød -h7 w P 1 H ux s E J K Model A B C D E 1 G H J K L M N P R S V V1 V2 X Y t t1 w z ød uxs 450 827 726 486 568 308 200 111 322 681 348 388 586 118 364 45 5 624 450 487 530 336 596 12 8 70 43 40 13x18 500 918 800 538 638 345 245 120 352 750 385 425 623 118 401 50 5 694 500 541 580 373 666 12 8 70 43 40 13x18 560 1030 892 603 714 383 280 125 390 844 433 483 667 114 439 48 7 770 560 605 646 411 742 14 9 70 48.5 45 13x18 630 1157 998 679 800 433 328 110 434 945 483 533 717 114 489 53 6 856 630 674 716 461 828 14 9 70 48.5 45 13x18 710 1302 1120 765 898 479 360 150 484 1057 529 579 787 138 535 63 7 954 710 751 796 507 926 14 9 90 53.5 50 17x22 800 1468 1254 862 1006 533 405 171 540 1180 583 633 841 138 589 74 7 1062 800 837 886 561 1034 14 9 90 53.5 50 17x22 900 1648 1408 971 1130 595 455 189 604 1319 645 695 911 146 651 89 7 1186 900 934 986 623 1158 18 11 90 64 60 17x22 1000 1810 1540 1066 1266 663 500 200 656 1450 713 763 979 146 719 90 9 1322 1000 1043 1086 691 1294 18 11 90 64 60 17x22 All Dimensions in mm. 27

X 1120-1400 X N X R L G B M t D A S Y C Ød-h7 V V1 V2 z t1 w P H uxs E J K Model A B C D E G H J K L M N P R S V V1 V2 X Y t t1 w z ød uxs 1120 2033 1725 1200 1422 744 290 748 1630 804 870 1173 160 800 95 9 1478 1120 1180 1226 772 1450 18 11 110 69 65 17x22 1250 2285 1930 1353 1524 803 300 830 1831 878 953 1250 166 859 99 9 1580 1250 1303 1356 831 1552 20 12 110 74.5 70 17x22 1400 2568 2170 1515 1794 934 310 963 2057 1009 1084 1396 181 990 113 13 1850 1400 1480 1506 962 1822 22 14 110 85 80 17x22 All Dimensions in mm. 28

UI 315-400 UI G B N X R t D A C V2 V1 V Y S z t1 Ød-h7 w P uxs H E J L Q M Model A B C D E G H J K L M N P R S V V1 V2 X Y t t1 w z ød uxs 315 578 518 340 404 223 330 236 480 253 705 60 279 38 274 3 460 315 356 395 251 432 8 7 40 28 25 13x18 355 654 578 383 452 247 368 260 548 287 765 60 303 30 300 6 508 355 395 435 275 480 8 7 40 33 30 13x18 400 736 650 432 506 274 402 290 612 314 812 60 330 38 320 5 562 400 438 480 302 534 8 7 40 33 30 13x18 All Dimensions in mm. 450-1000 UI B N G X R t A D C 1 V2 V1 V Y S z t1 Ød-h7 w P 1 H UxS E J K Q M L Model A B C D E 1 G H J K L M N P R S V V1 V2 X Y t t1 w z ød uxs 450 827 726 486 568 308 200 111 322 681 348 876 80 364 45 340 5 624 450 487 530 336 596 10 8 50 38 35 13x18 500 918 800 538 638 345 245 120 352 750 385 933 80 401 50 360 5 694 500 541 580 373 666 10 8 50 38 35 13x18 560 1030 892 603 714 383 280 125 390 844 433 1018 90 439 48 378 7 770 560 605 646 411 742 12 8 70 43 40 13x18 630 1157 998 679 800 433 328 110 434 945 483 1090 90 489 53 400 6 856 630 674 716 461 828 12 8 70 43 40 13x18 710 1302 1120 765 898 479 360 150 484 1057 529 1156 90 535 63 420 7 954 710 751 796 507 926 14 9 70 48.5 45 17x22 800 1468 1254 862 1006 533 405 171 540 1180 583 1228 90 589 74 440 7 1062 800 837 886 561 1034 14 9 70 48.5 45 17x22 900 1648 1408 971 1130 595 455 189 604 1319 645 1360 110 651 89 490 7 1186 900 934 986 623 1158 16 10 90 59 55 17x22 1000 1810 1540 1066 1266 663 500 200 656 1450 713 1448 110 719 90 510 9 1322 1000 1043 1086 691 1294 16 10 90 59 55 17x22 All Dimensions in mm. 29

UI 1120-1400 UI G B N X R t A D C V2 V1 V Y S z t1 Ød-h7 w P H uxs E J L Q M Model A B C D E G H J K L M N P R S V V1 V2 X Y t t1 w z ød uxs 1120 2033 1725 1200 1422 744 290 748 1630 804 1680 110 800 95 572 9 1478 1120 1180 1226 772 1450 18 11 90 64 60 17x22 1250 2285 1930 1353 1524 803 300 830 1831 878 1844 140 859 99 632 9 1580 1250 1303 1356 831 1552 18 11 110 69 65 17x22 1400 2568 2170 1515 1794 934 310 963 2057 1009 2060 140 990 113 717 13 1850 1400 1480 1506 962 1822 20 12 110 74.5 70 17x22 All Dimensions in mm. 30

UII 315-400 UII G B N X R t A D C V2 V1 V Y S z t1 Ød-h7 w P uxs H E J L Q M Model A B C D E G H J K L M N P R S V V1 V2 X Y t t1 w z ød uxs 315 578 518 340 404 223 330 236 480 253 705 60 279 38 274 3 460 315 356 395 251 432 8 7 40 28 25 13x18 355 654 578 383 452 247 368 260 548 287 765 60 303 30 300 6 508 355 395 435 275 480 8 7 40 33 30 13x18 400 736 650 432 506 274 402 290 612 314 812 60 330 38 320 5 562 400 438 480 302 534 8 7 40 33 30 13x18 All Dimensions in mm. 450-1000 UII B N G X R t D A C 1 V2 V1 V Y S z t1 Ød-h7 w P 1 H UxS E J K Q M L Model A B C D E 1 G H J K L M N P R S V V1 V2 X Y t t1 w z ød uxs 450 827 726 486 568 308 200 111 322 681 348 876 70 364 45 340 5 624 450 487 530 336 596 10 8 50 38 35 13x18 500 918 800 538 638 345 245 120 352 750 385 933 70 401 50 360 5 694 500 541 580 373 666 10 8 50 38 35 13x18 560 1030 892 603 714 383 280 125 390 844 433 1018 90 439 48 378 7 770 560 605 646 411 742 12 8 70 43 40 13x18 630 1157 998 679 800 433 328 110 434 945 483 1090 90 489 53 400 6 856 630 674 716 461 828 12 8 70 43 40 13x18 710 1302 1120 765 898 479 360 150 484 1057 529 1176 110 535 63 420 7 954 710 751 796 507 926 14 9 90 53.5 50 17x22 800 1468 1254 862 1006 533 405 171 540 1180 583 1248 110 589 74 440 7 1062 800 837 886 561 1034 14 9 90 53.5 50 17x22 900 1648 1408 971 1130 595 455 189 604 1319 645 1360 110 651 89 490 7 1186 900 934 986 623 1158 18 11 90 64 60 17x22 1000 1810 1540 1066 1266 663 500 200 656 1450 713 1448 110 719 90 510 9 1322 1000 1043 1086 691 1294 18 11 90 64 60 17x22 All Dimensions in mm. 31

UII 1120-1400 UII G B N X R t A D C V2 V1 V Y S z t1 Ød-h7 w P H uxs E J L Q M Model A B C D E G H J L M N P Q R S V V1 V2 X Y t t1 w z ød uxs 1120 2033 1725 1200 1422 744 290 748 1630 804 1710 140 800 95 572 9 1478 1120 1180 1226 772 1450 18 11 110 69 65 17x22 1250 2285 1930 1353 1524 803 300 830 1831 878 1844 140 859 99 632 9 1580 1250 1303 1356 831 1552 20 12 110 74.5 70 17x22 1400 2568 2170 1515 1794 934 310 963 2057 1009 2060 140 990 113 717 13 1850 1400 1480 1506 962 1822 22 14 110 85 80 17x22 All Dimensions in mm. 32

Accessories Inlet lange Model A B C H n x d 315 315 356 395 120 8 x 10 355 355 395 435 120 8 x 10 H H 400 400 438 480 120 8 x 10 N x Ød 450 450 487 530 120 8 x 10 500 500 541 580 120 8 x 10 560 560 605 646 120 8 x 10 630 630 674 716 120 8 x 10 ØB 710 710 751 796 120 8 x 10 ØC ØA 800 800 837 886 120 12 x 12 900 900 934 986 120 12 x 12 1000 1000 1043 1086 120 12 x 12 1120 1120 1180 1226 200 14 x 12 1250 1250 1303 1356 200 16 x 14 1400 1400 1480 1506 200 18 x 14 All Dimensions in mm. Outlet lange C B G Model A B C D E G 315 223 251 279 404 432 460 28 355 247 275 303 452 480 508 28 400 274 302 330 506 534 562 28 E A D 450 308 336 364 568 596 624 28 500 345 373 401 638 666 694 28 560 383 411 439 714 742 770 28 630 433 461 489 800 828 856 28 315-1120 Ø9 710 479 507 535 898 926 954 28 800 533 561 589 1006 1034 1062 28 C B G 900 595 623 651 1130 1158 1186 28 1000 663 691 719 1266 1294 1322 28 1120 744 772 800 1422 1450 1478 28 1250 803 831 859 1524 1576 1624 50 1400 934 962 990 1794 1860 1920 63 E A D All Dimensions in mm. 1250-1400 33

Operational Limits - 315 355 400 450 500 560 630 710 800 900 1000 1120 1250 1400 Maximum Absorbed Power Maximum an Speed Temperature Range Min. -20 o C an weight C kw 2.5 3 3.5 4 5 6 7 T kw 5 6 7 10 11 13 16 9 11 14 16 20 25 35 X kw 10 12 15 18 22 26 32 20 25 30 40 50 55 70 Z kw 40 50 60 80 100 110 150 UI kw 2.5 3 3.5 4 5 6 7 9 11 14 16 20 25 35 UII kw 5 6 7 10 11 13 16 20 25 30 40 50 55 70 UIII kw 10 12 15 18 22 26 32 40 50 60 80 100 110 150 C rpm 3200 2800 2500 2200 1950 1800 1500 T rpm 4200 3700 3300 2900 2550 2300 2000 1350 1200 1050 950 850 780 680 X rpm 5300 4700 4200 3600 3200 2900 2500 1800 1600 1400 1250 1150 1000 880 Z rpm 2250 2000 1750 1600 1450 1300 1100 UI rpm 3200 2800 2500 2200 1950 1800 1500 1350 1200 1050 950 850 780 680 UII rpm 4200 3700 3300 2900 2550 2300 2000 1800 1600 1400 1250 1150 1000 880 UIII rpm 5300 4700 4200 3600 3200 2900 2500 2250 2000 1750 1600 1450 1300 1100 C Max. o C 85 85 85 85 85 85 85 T-X-Z Max. o C 100 100 100 100 100 100 100 100 100 100 100 100 100 100 UI-UII-UIII Max. o C 180 180 180 180 180 180 180 180 180 180 180 180 180 180 C kg 19 25 33 42 55 76 101 T kg 33 49 59 71 89 123 152 189 228 285 338 575 769 1048 X kg 35 51 60 73 91 126 154 192 232 289 345 586 782 1068 UI kg 32 45 55 68 83 112 140 180 250 311 366 601 833 1139 UII kg 33 46 55 69 84 113 142 182 252 314 369 606 839 1152 34

35