VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

Similar documents
CENTRIFUGAL IN-LINE FANS VENT Series

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

ACOUSTIC CABINET FANS CVAB / CVAT Series

IN-LINE CENTRIFUGAL DUCT FANS VT Series

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

ACOUSTIC CABINET FANS CVB / CVT Series

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

DIRECT-AIR ILB / ILT Series Rectangular duct fans

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

BATHROOM EXTRACT FANS DECOR-100 Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

Plate mounted axial flow fans HXBR / HXTR Series

supplied in Form (B) configuration. Airflow over Impeller- Motor.

Short casing. Long casing (L version) Commercial premises

MIXVENT-TH Series Mixed Flow Fans

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

COMPACT Series type HCFB / HCFT (Plastic impellers)

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

EDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc

NEW Slimpak EC Box Fan (SLPT EC)

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM

TGT Series Adjustable Pitch Fans

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

NEW Acoustic In-Line Fans (ACQ)

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

TGT Series Adjustable Pitch Fans

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

ACOUSTIC CABINET FANS FOR SUPPLY AIR APPLICATIONS CAIB/T PRO-REG Series

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

CA V0 E RANGE In-line centrifugal fans in self-extinguishing plastic

CGT Series Adjustable Pitch Fans

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

CGT Series Adjustable Pitch Fans

TD-SILENT Series (160 to 1000 models)

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

CHMT Series, F Rated Fans

MegaBox Product-specific information

Sentinel D-Box Twin Fan

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

Mixed Flow Roof Fans (RMH)

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

Sentinel D-Box Single Fan

BELT DRIVEN CABINET FANS CVTT Series

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Acoustic Twin Fans (ATQ)

Mixed Flow Roof Fans (RMH)

Square Mixed Flow Fans (MFQ)

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

TD-ECOWATT AND DECOR-ECOWATT Series

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

Unobox units with backward curved centrifugal impellers

HIGH TEMPERATURE TWIN SQUIF FANS

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Single phase speed controller.

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting.

CMP-L/EW B T D. Industrial Brushless Motors E.C. Motor power (CV) Three-phase VSD 400 V50/60 Hz. electrical power Maximum.

AC Commercial Fans Edition. ErP ready

HIGH-POWERED VENTILATORS

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

CYLINDRICAL CASED AXIAL FLOW FANS

CK, LPK, LPKB. Duct fans with circular connection.

Multifunctional 400ºC/2h and 300ºC/2h roof fans

CMP/EW EFFICIENT WORK

BOX BLB Centrifugal Box Fan

ROOF MOUNTED FANS MAX-TEMP Series, Centrifugal 400 ºC/2h Rated Fans

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

TKC, TKS, TKV/TKH Roof fans

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

Transcription:

CENTRIFUGAL IN-LINE FANS Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a pre-wired wiring junction box and a robust mounting foot. All model include an enclosed type, single-phase external rotor motor with factory matched backward curved nonstalling impeller. (1) Models 355 and 4 are manufactured in sheet steel protected against corrosion by cataforesis primer and black polyester paint finish. - to -315 Motors 315 models: Motors are IP44, class B insulation with ball bearings and safety thermal overload protection. 355 and 4 models: Motors are IP54, class F, with ball bearings and safety thermal overload protection. Electrical supply: Single phase 23V 5/6Hz. Three phase 23/4V 5Hz (models 355 and 4). (See characteristics chart). All models are speed controllable. Additional Information L version: High performance models. B Version: Standard performance models for lower noise level requirements. Impellers from to 16 models are manufactured from injection moulded plastic. -355 and -4 A P P L I C A T I O N S Mounting foot Warehouses Workshops Supplied with unit as standard Commercial premises Cafes, bars and small restaurants Offices Commercial and industrial kitchens 646

Technical characteristics Before installation check that the product electrical characteristics listed on the data plate label (Voltage, power, frequency etc) match those of the intended electrical supply. Model Voltage V/Hz Speed (rpm) absorbed power (W) absorbed current (A) airflow Sound pressure level at 3m (db(a)) Minimum ambient temperature (ºC) ambient temperature (ºC) -B 23-5 2 48,22 235 38-4 4 3 -L 23-5 25 75,33 29 47-4 6 3-125B 23-5 19 44,21 28 39-4 4 3-125L 23-5 245 8,35 41 47-4 6 3-15B 23-5 2 7,3 56 46-4 6 5-15L 23-5 27 12,53 7 5-4 6 5-16B 23-5 2 7,3 6 45-4 6 5-16L 23-5 275 13,55 76 51-4 6 5 -B 23-5 225 125,5 83 47-4 6 5 -L 23-5 26 17,72 52-4 6 5-25B 23-5 23 13,55 935 49-4 6 6-25L 23-5 275 18,8 1 54-4 6 6-315B 23-5 24 23 1, 1475 49-4 5 8-315L 23-5 27 315 1,3 163 57-4 5 8-355L 23-5 135 28 1,2 265 6-4 7 17-4L 23-5 125 4 1,6 338 61-4 5 22 Weight (kg) -355L-T 23/4-5 1375 29 1,4/,8 265 6-4 7 17-4L-T 23/4-5 136 45 1,9/1,1 338 61-4 5 22 Dimensions (mm) - to 315-355 / -4 Model A B C D D2 E F G H J - 194 23 243 98-125 195 27 243 123-15 214 24 333 147-16 222 28 333 157-223 25 333 198-25 26 27 333 248-315 23 25 41 312-355 41 314 58 354 314 552 17 587 1,5-4 431 354 568 399 354 628 185 647 1,5 647

Acoustic characteristics Sound power level spectrums (LwA) at the maximum airflow (Pa). Model LwA 63 125 25 5 4 8 TOT Inlet 44 53 63 6 67 61 52 41 7 L Outlet 42 48 67 61 63 61 55 44 7 Radiated 42 44 53 51 46 45 4 33 56 Inlet 37 43 54 49 59 54 48 39 61 B Outlet 38 42 56 48 53 53 49 38 6 Radiated 36 33 32 36 4 38 34 26 45 Inlet 38 47 59 67 65 62 56 44 7 125L Outlet 38 45 61 64 63 63 56 46 69 Radiated 37 43 45 51 47 45 42 33 54 Inlet 33 43 55 57 57 55 51 41 62 125B Outlet 34 41 57 53 55 56 52 41 62 Radiated 34 36 35 38 41 39 37 28 46 Inlet 4 45 63 73 69 64 61 46 75 15L Outlet 4 45 63 66 67 64 61 47 72 Radiated 4 37 46 59 51 5 43 3 6 Inlet 36 44 58 7 64 6 56 4 71 15B Outlet 36 43 55 62 62 59 56 4 67 Radiated 36 38 4 53 46 45 41 29 55 Inlet 39 45 63 74 7 67 63 48 77 16L Outlet 43 45 61 67 68 65 62 49 72 Radiated 43 36 44 6 52 51 45 32 61 Inlet 35 41 56 69 63 6 56 42 71 16B Outlet 35 42 54 63 61 59 57 42 67 Radiated 35 37 37 52 45 45 42 29 54 Model LwA 63 125 25 5 4 8 TOT L B 25L 25B 315L 315B 355L 4L Inlet 42 52 63 7 69 68 66 6 75 Outlet 43 51 63 7 69 69 68 59 75 Radiated 43 48 4 51 53 52 49 39 58 Inlet 41 53 6 67 66 64 63 52 72 Outlet 42 51 61 65 66 66 65 53 72 Radiated 42 42 34 46 48 53 46 37 56 Inlet 43 57 67 71 72 7 7 6 78 Outlet 42 53 67 73 75 75 72 62 8 Radiated 36 52 37 53 53 51 5 38 59 Inlet 42 53 62 68 69 66 66 57 74 Outlet 39 48 62 7 7 69 67 59 76 Radiated 38 43 36 52 48 5 48 42 56 Inlet 45 58 7 74 75 76 71 66 81 Outlet 57 58 72 76 77 77 72 68 83 Radiated 51 54 49 56 61 59 56 48 65 Inlet 44 59 68 7 71 7 67 6 77 Outlet 44 51 71 72 75 74 69 64 8 Radiated 43 43 47 5 52 55 53 43 59 Inlet 4 57 68 71 71 67 59 48 76 Outlet 42 59 62 69 7 68 6 5 74 Radiated 41 55 43 5 55 51 42 29 59 Inlet 42 61 69 72 67 66 63 5 76 Outlet 47 63 66 7 69 68 64 51 75 Radiated 45 58 45 52 52 5 46 3 61 Performance curves Q = Air volume in, m 3 /hr and m 3 /s. = Static pressure in Pa. Dry air at 2ºC and 76 mmhg. Performance data in accordance with ISO 581 and AMCA 21-99 Standards. - 125L 125B 648

45 4 35 3 25 15 Performance curves Q = Air volume in, m 3 /hr and m 3 /s. = Static pressure in Pa. Dry air at 2ºC and 76 mmhg. Performance data in accordance with ISO 581 and AMCA 21-99 Standards. t (Pa) 5 16L 15L 16B 15B 46 45 51 52 53 54-15 -16 P(W) 25 15 48 5 47 5 51 5 55 56 3 4 5 6 7 Q..4.8.12.16.2 Q (m 3 /s) t (Pa) 9 8 7 6 315L -315 P(W) 6 5 4 5 4 315B 58 6 3 3 57 49 3 6 9 1 15 18 Q..1.2.3.4.5 Q (m 3 /s) 58 64 t (Pa) 5 45-4 P(W) 9 4 8 35 3 25 15 47 52 7 6 5 4 3 5 55 5 15 25 3 Q..2.4.6.8 Q (m 3 /s) 649

Mounting accessories MBE Electric Heater MBW Hot water coil SIL Circular sound attenuators MFL-G4 Filtration box of G4 grade filtration MFL-F Box in galvanized steel for inserting the MFR F5, F6 and F7 filters Mounting foot (supplied with unit as standard) ACOP- Flexible connectors DEF- Protection Grille GSA M Aluminium flexible ducting GSI M Insulated aluminium ducting CX Worm drive duct connectors BOC Metal inlet valves BOR Plastic inlet valves GCI Circular inlet grilles GRI Interior square grilles VR GCI mounting frame RP GRI mounting frame CAR Backdraught shutters For more information see MOUNTING ACCESSORIES. 65

Electrical accessories REB Electronic single phase speed controllers RMB Autotransformer single phase speed controllers PARO/MARCHA 5P and 8P ON/OFF Electrical isolation switch PULSER Electric heater controllers for 1Ph models up to 36W and 3Ph models up to 64W TTC Electric heater controllers for 3 phase models TG-K Duct temperature sensor TG-R Room wall mounted temperature sensor For more information see MOUNTING ACCESSORIES. 651