Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. A wide variety of spool options allows to design an unlimited number of hydraulic circuits. Versions with 8 watt coils, position control, ATEX approval, surface protection and connector variants are shown in the following chapters. The valve is also available as sandwich type, see series Z1DW in chapter 7. Valves with explosion proof solenoids Ex e mb ll see series D1VW Explosion Proof in chapter and catalogue HY11-3343. Download: www.parker.com/euro_hcd - see Literature A B Technical data General Design Directional spool valve Actuation Solenoid Nominal size DIN NG6 / CETOP 3 / NFPA D3 Mounting interface DIN 434 A6 / ISO 441 / CETOP RP 11-H / NFPA D3 Mounting position unrestricted, preferably horizontal Ambient temperature [ C] -5...+6 MTTF D value [years] 15 Weight [kg] 1.5 (1 solenoid),.1 ( solenoids) Vibration resistance [g] 1 Sinus 5... Hz acc. IEC 68--6 3 Random noise... Hz acc. IEC 68--36 15 Shock acc. IEC 68--7 Hydraulic Max. operating pressure [bar] P, A, B: 35; T: 1 (DC), T: 14 (AC) Fluid Hydraulic oil according to DIN 5154 Fluid temperature [ C] -... +7 (NBR: -5...+7) Viscosity permitted [cst] / [mm²/s].8...4 Viscosity recommended [cst] / [mm²/s] 3...8 Filtration ISO 446 (1999); 18/16/13 Flow max. [l/min] 8 (see shift limits) Leakage at 5 bar [ml/min] Up to 1 per flow path, depending on spool, up to 15 per flow path for spool type 8 + 9 Static / Dynamic Step response see table response time Electrical characteristics Duty ratio [%] 1 ED; CAUTION: coil temperature up to 15 C possible Max. switching frequency [1/h] 15 (not for soft shift) Protection class IP65 in accordance with EN 659 (with correctly mounted plug-in connector) K J U G Y T Supply voltage [V] 1 V = 4 V = 98 V = 5 V = 11 V at 5 Hz/ 3 V at 5 Hz/ 1 V at 6 Hz 4 V at 6 Hz Tolerance supply voltage [%] ±1 ±1 ±1 ±1 ±5 ±5 Current consumption hold [A].7 1.9.33.13.6 /.55.3 /.7 Current consumption in rush [A].7 1.9.33.13.5 /.4 1.5 / 1. Power consumption hold 3.7 W 31 W 31.9 W 8. W 7 / 7 VA 7 / 7 VA Power consumption in rush 3.7 W 31 W 31.9 W 8. W 8 / 9 VA 8 / 9 VA Solenoid connection Connector as per EN 17531-83, solenoid identification as per ISO 9461 (code W). Wiring min. [mm²] 3 x 1.5 recommended Wiring length max. [m] 5 recommended With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations. D1VW UK.indd RH 17.4.15-5
Ordering 3 position spools Spool type a b 1 3 4 5 6 7 C D 1 V W Directional control valve Standard Size DIN NG6 CETOP 3 NFPA D3 3-chamber valve 3 position spools Wet pin armature solenoid, threaded in tube Spool position Spool type 8,9, 4, 5 Spool type Spool position 3 positions. Spring offset in position. Operated in position a or b. 8 1) 9 1) 1 11 14 15 16 1 31 3 34 35 61 81 8 1 4 1) 5 1) position spools Spool type a b 6 3 83 1) 11 8 E F K M B D H Operated in position a. Spring offset in position b. Operated in position b. Spring offset in position a. 1) Consider specific spool position. ) To be used in combination with rectifier plugs at 1 VAC / 3 VAC power supply. 3) DC only Operated in position b. Spring offset in position a. Operated in position a. Spring offset in position b. position spools Standard Spool type 83 Spool position positions. Spring offset in position. positions. Operated in position. positions. Spring offset in position. positions. Operated in position. positions. Spring offset in position b. Operated in position a. positions. Operated in position a or b. No center or offset position. positions. Spring offset in position a. Operated in position b. D1VW UK.indd RH 17.4.15-6
Ordering W Seals Solenoid voltage Solenoid connector as per EN 17531-83, without plug (other connectors are available for D1MW Series) Solenoid option Design series (not required for ordering) omit T S 3) S3 3) 4N 3) Solenoid option manual override (standard) without manual override Soft shift orifice size.5 mm. Soft shift orifice size.75 mm. with lockable manual override Voltage K 1 V = J 4 V = U ) 98 V = G ) 5 V = Y T 11 V 5 Hz / 1 V 6 Hz 3 V 5 Hz / 4 V 6 Hz N V Seals NBR FPM Further spool types, solenoid voltages and connectors on request. D1VW UK.indd RH 17.4.15-7
Flow Curve Diagram Flow curve 4 14 13 1 9 8 7 16 6 5 4 11 3 1 Pressure drop [bar] 1 1 8 4 4 6 8 All characteristic curves measured with HLP46 at 5 C. Position b Position a Position Spool P--T P-B P-B A-T P-A P-A P-B A-T B-T P-T 1 1 4 1 4 1 1 5 5 3 3 4 3 6 7 4 3 3 7 7 5 1 6 1 4 1 4 7 7 7 3 3 7 1 3 3 11 14 14 14 3 3 7 15 3 6 3 4 7 16 1 B 4 4 3 6B 4 4 3B 3 1 34 4 8 3 3 5 7 35 3 3 4 8 7 5 81 13 13 13 13 8 13 13 13 13 1) 1) 11B 11 1 1 9 1 1 4 1 4 5 5 8 8 6 61 1 3 1 3 3 83H 5 5 8 3 P-B A-T P--T P-A P-B A-T B-T P-T 8 4 5 4 5 9 9 5 5 6 7 7 83B 5 5 4 1 3 4 3 7 4 7 5 4 3 1 3 7 4 5 Position b Position a Spool P-A P-B A-B P-B A-T 1 4 4 P--T P-A P-B A-B 6 5 1) Only for pressure compensation, no high flow possible. D1VW UK.indd RH 17.4.15-8
Shift Limits The diagram below specifies the shift limits for valves with DC & AC solenoids. Valves with spool position F or M can only be operated up to 7 % of the limits. The specifications apply to a viscosity of 4 mm /s and balanced flow conditions. The shift limits can be considerably lower at unbalanced flow conditions. To avoid flow rates beyond the shift limits, a plug-in orifice can be inserted in the P-port. Valve with standard DC solenoid Measured with HLP46 at 5 C, 9 % U nom and warm solenoids Valve with standard AC solenoid Pressure [bar] 35 3 5 15 1 5, 8, 16, 7, 14, 81 4 6 4 5, 8, 16, 6, 3 1 5 Pressure [bar] 35 3 5 15 1 3 4 5 6 7 8 9 11 8 9, 11, 1 3, 15, 4, 5 1,1, 1 5 1 3 4 5 6 7 8 9 Measured with HLP46 at 5 C, 95 % U nom and warm solenoids D1VW UK.indd RH 17.4.15-9
Shift Limits / Response Times Shift limit diagram - Soft shift with 1 DC solenoid Supply pressure [bar] Supply pressure [bar] 35 3 5 15 1 5 35 3 5 15 1 5 11, 3 9, 1, 4, 1 81 1 3 4 5 6 7 8 Shift limit diagram - Soft shift with DC solenoids D 9 1 3 4 5 6 7 8 Measured with HLP46 at 5 C, 9 % U nom and warm solenoids. 81, 8 1, 4 Response times D1VW Standard and Soft Shift [ms] Standard solenoid Orifice Energize De-energize Standard DC w/o 45-6 - 3 Standard AC w/o 13 Standard DC with rectifier plug w/o 6-7 7-9 Response times soft shift solenoid valve solenoid valve 1 solenoid valve 3 positions 3 positions positions Orifice size Center position: Closed Center position: Open Energize De-energize Energize De-energize Energize De-energize S.5 mm - 75 31-65 - 4 35-75 9-35 16-5 S3.75 mm 18-3 3-4 - 35 3-5 9-35 13-35 The lower value applies to small flow rates and low pressure, the upper value to high flow rates and high pressure. Step response times were obtained under the following conditions: HLP46 at 5 C with the valve operating at nominal pressure and flow. Published response times are nominal and may vary with spool, flow, pressure and temperature. Acceleration for orifice size.75, code S3 (measured against a standard valve) build-in orifice A B For even softer shifting, the proportional spools 81, 8, 11 and 1 can be used. D1VW UK.indd RH 17.4.15-1
Dimensions Interface EN 17531-83, DC solenoid B, E, F -style H, K, M -style 91.4 16 46 69 93 A B 134.6 16 46 69 93 C, D -style Option 4N, with lockable manual override (available for all styles, DC only) 69 93 93 91.4 6 46 119.4 19 Interface EN 17531-83, AC solenoid B, E, F -style H, K, M -style 69.5 93.5 84 15 46 C, D -style 69.5 93.5 69.5 93.5 17 15 46 84 11 46 Surface finish BK375 4x M5x3 ISO 476-1.9 7.6 Nm ±15 % NBR: SK-D1VW-N-91 FPM: SK-D1VW-V-91 The space necessary to remove the plug per EN 17531-83, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be.5 to.6 Nm. D1VW UK.indd RH 17.4.15-11