Class 320 Metering. Class 320 Metering. Meter Mounting Equipment

Similar documents
Meter Mains - With Optional MCC Bypass

Group Meter Main - Without Bypass

Meter Mains - Without Bypass

CT Metering. CT Metering. Meter Mounting Equipment

Multiple Metering, Vertical Gang

Multiple Metering, Horizontal Gang - Non Lever Bypass

For vertical multi-meter installations 1-6 meter positions Designed to receive watthour meters that meet ANSI C12.10 Overhead or underground feed

RMTR-11HOU. Meter Mounting & Distribution Equipment Houston Area Utilities

Commercial Meter Pedestals

Accessories. Accessories. Meter Mounting Equipment

Cooper B-Line RESIDENTIAL SERVICES

5.10. Metering Products. Contents. House Panels. Meter Breakers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

New England. Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

REC Municipal Meter Mounting Equipment

Equipment. Metering. Metering Equipment 1. Contents

Meter Centers Meter Mounting Devices

Metering Products. 4.1 Meter Sockets. 4.2 Meter Breakers. 4.3 Group Metering

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection

Metering NEED. Meter Sockets. Product Description

Indiana Meter Mounting Equipment

Equipment. Metering. Metering Equipment 1. Contents

Power Mod. Type WC House Power Module. Revised 06/01/13. WC Series House Power Module

Wisconsin Area Catalog

4.10. Metering Products. Contents Description Systems for Residential and Commercial. Main Service Modules. Group Metering

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

Meter Mounting Equipment Wisconsin Area

MEG Approval Meter Equipment Group

Instrument Rated Metering Equipment

Ohio Meter Mounting Equipment

Pennsylvania, Delaware, South New Jersey, West Virginia Area Product Catalog

Louisiana & Mississippi Area Catalog

Current Transformer, Termination & Disconnect Cabinets WE Energies Approved

New Jersey PSE&G, Jersey Central Power & Light Territory Meter Mounting Equipment

ComEd Service Area Meter Mounting Equipment

New York City Apartment Metering Meter Sockets / Load Centers

5.1. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents. Product Description. Single Meter Sockets

LP Dimming Panels. GRAFIK Systems

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

Duke/MEG Approval Meter Equipment Group

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Meter Centers & Loadcenters Group Metering

Meter Mounting Equipment. GA/AL/FL Panhandle Area

Meter Mounting Equipment Commonwealth Edison

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

MP Meter-Pak Meter Centers

Selection and Application Guide For use in New England EQUIPMENT

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

Group Metering & Meter Breakers. Group Metering & Meter Breakers 5-1. Contents

Selection and Application Guide For use in Alabama, Georgia, Mississippi and the Florida Panhandle. meter mounting

Louisiana/Mississippi. Area Catalog

(CT, NH, ME, RI, VT, MA)

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

EZ Meter-Pak Meter Centers

Ameren Service Area Product Catalog

10 Commercial, Industrial, Agricultural Services

Eylander Electric Inc

5.11. Metering Products. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

1 OF 8 LAD LAD PROJECT AREA KIMBERLY GERBER TITLE SHEET C.E.S. DWG. NO. NPN12045 SHEET INDEX

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

PSE&G Long Island Meter Mounting Equipment

Meter Mounting Equipment. Arkansas, W. Tennessee, N. Mississippi Market

Selection and Application Guide For use in Arkansas, Oklahoma & Texas. meter mounting

Selection and application guide

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets

SPEEDFAX TM 2011 Meter Centers Contents

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit

Meter Mounting Equipment DTE Energy Area

CON EDISON EQUIPMENT

Selection and application guide

Power Mod. Meter Stacks: WMM Residential Stacks. Residential Meter Stacks

Section 6 Electric Metering: Residential

Tennessee Area Meter Mounting Equipment

Selection and application guide

SECTION PANELBOARDS

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Selection and application guide. For use in Ohio. Meter Mounting Equipment.

Selection and application guide. For use in Kansas, Iowa, Missouri and Illinois. Meter mounting equipment.

Meter Mounting Equipment. Northern Indiana Public Service Co.

Ameren Service Area Product Catalog

Main Wire Size AWG/kcmil. Product Catalog # UPC Code QOM22225NS

Selection and application guide. For use in Texas. Meter Mounting Equipment.

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection...

Power Mod. Type WMM Residential Meter Stacks. Revised 06/01/13. Residential Meter Stacks

Customer Requirements Meter Socket Configurations

DTE Energy Area Catalog and Consumers Energy Multi-Position Sockets

Introduction. Upon completion of Basics of Meter Mounting Equipment

Modular Metering Construction Details

Single Socket and Horizontal Metering

Selection & Application Guide. BFT Main Feed Thru Modules. Power Mod. usa.siemens.com/powermod

Power Mod. Standard Tapboxes.

Power Mod. Introduction.

Meter Mounting Equipment Colorado Area

fastfax Rock Solid TM Load Centers General Information

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Single Socket and Horizontal Metering

Florida Area Catalog. Milbank Manufacturing 4801 Deramus Ave., Kansas City, MO milbankworks.com

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

American Electric Supply, Inc.

Transcription:

Single Meter Sockets, Without ypass -............................ 57-58 Meter Mains, With Optional MCC ypass -......................... 59-60 Meter Main Load Centers, With Optional MCC ypass -.......... 61-62 Class 320 - Meter reaker Data............................................................. 63 Class 320 - Wiring Diagrams........................................................... 64-65 56

Single Meter Sockets - Without ypass Application Manual circuit closing bypass (link bypass) under separate cover Receive ASI C12.10 watthour meters Surface mount Construction EMA Type 3R ASI 61 gray E-coat finish Aluminum snap ring included Standards UL 414 Listed ASI C12.7 EUSERC 302 324 (open) 324C (open) Accessories Flush Trim Kit - FK1432 or FK2432 H Hubs Part/UPC Catalog Max Amp Service umber umber Rating Jaws Type Access ypass 78205162220 324C * 400 4 1Ø/3W UG MCC 78205162210 324 ** 400 4 1Ø/3W OH/UG MCC Part/UPC Catalog Connections Overall Dimensions Top Knockout umber umber Line Load eutral Height Width Depth Provision Layout 78205162220 324C * Studs #4-600 MCM Studs 32 24 6 one Fig. 1 78205162210 324 ** #4-600 MCM #4-600 MCM #4-600 MCM 32 14 6 H Hub Fig. 2 * Complies with EUSERC 302A ** Complies with EUSERC 302 57

Single Meter Sockets - Without ypass Style # Suffixes 324C SS - Stainless Steel * 324 MS-20 - Sealing Ring Interlocking Cover Knockouts - Conduit Sizes 2A = 1 2" - 1 4" 3H = 3-2 1 2" - 2" 4H = 3-2 1 2" - 2-1 1 2" 2K = 4" - 3 1 2" = 4-3 1 2" - 3" Top Provision = See Chart * Knockouts and top provisions are not available in Stainless Steel (SS) finish Knockout Layouts Fig. 1 Fig. 2 Top Provision 2K 4H 4H 2A 2H utility side only 3H 3H 2A 3H 4H both sides 58

Meter Mains - With Optional MCC ypass Application Combination meter/main with optional manual circuit closing (link type) bypass Factory installed breaker Receive ASI C12.10 watthour meters Surface mount Construction EMA Type 3R ASI 61 gray E-coat finish Aluminum snap ring included Removable door with sealing provision and lifting handles U404MC (closed) U404MC (open) Standards UL 67 Listed ASI C12.7 EUSERC 302 Accessories Flush Trim Kit - FK2438 Overhead Adapter - CK8326 Part/UPC Catalog Max Amp Service Main reaker umber umber Rating Jaws Type Access Voltage AIC Main ypass 78205181515 U4042MC 400 4 1Ø/3W UG 120/240 10K (2) 200A, 2P -- 78205181517 U4042MCC 400 4 1Ø/3W UG 120/240 10K (2) 200A, 2P MCC 78205181525 U404MC 400 4 1Ø/3W UG 120/240 22K (1) 400A, 2P -- 78205181530 U404MCC 400 4 1Ø/3W UG 120/240 22K (1) 400A, 2P MCC Part/UPC Catalog Connections Overall Dimensions Top Knockout umber umber Line Load eutral Height Width Depth Provision Layout 78205181515 U4042MC Studs MC #6-250 MCM 38 30 6 one Fig. 1 78205181517 U4042MCC Studs MC #6-250 MCM 38 24 6 one Fig. 1 78205181525 U404MC Studs MC #6-600 MCM 38 24 6 one Fig. 2 78205181530 U404MCC Studs MC #6-600 MCM 38 24 6 one Fig. 2 59

Meter Mains - With Optional MCC ypass U404 U4042 Style # Suffixes MC - o bypass MCC - MCC bypass SS - Stainless Steel * Knockouts - Conduit Sizes 1A = 1 2" = 2 1 2" - 2-1 1 2" - 1 1 4" 4J = 3 1 2" - 3-2 1 2" - 2" = 4-3 1 2" - 3" 1W = 1 4" Top Provision = See Chart * Knockouts and top provisions are not available in Stainless Steel (SS) finish Knockout Layouts Fig. 1 Fig. 2 4J 4J 4J 1W (4) 1A 1W (4) 1A 60

Meter Main Loadcenters - With Optional MCC ypass Application Combination meter/main/loadcenter with optional manual circuit closing (link type) bypass Factory installed breaker Receive ASI C12.10 watthour meters Surface mount U4041123MC (closed) U4041123MC (open) Construction EMA Type 3R ASI 61 gray E-coat finish Aluminum snap ring included Removable door with sealing provision and lifting handles Standards UL 67 Listed ASI C12.7 EUSERC 302 Part/UPC Catalog Max Amp Service Main reaker umber umber Rating Jaws Type Access Voltage AIC Main Provisions Loadcenter ypass 78205157072 U40411230MC 400 4 1Ø/3W UG 120/240 22K (1) 200A, 2P (2) 100A 20/40 -- 78205157074 U40411230MCC 400 4 1Ø/3W UG 120/240 22K (1) 200A, 2P (2) 100A 20/40 MCC 78205119923 U4042208MC 400 4 1Ø/3W UG 120/240 22K (1) 200A, 2P (1) 200A 8 -- 78205120682 U4042208MCC 400 4 1Ø/3W UG 120/240 22K (1) 200A, 2P (1) 200A 8 MCC 78205177210 U4042230MC 400 4 1Ø/3W UG 120/240 22K (1) 200A, 2P (1) 200A 20/40 -- 78205177220 U4042230MCC 400 4 1Ø/3W UG 120/240 22K (1) 200A, 2P (1) 200A 20/40 MCC 78205177230 U404430MC 400 4 1Ø/3W UG 120/240 22K (1) 400A, 2P -- 30 -- 78205177240 U404430MCC 400 4 1Ø/3W UG 120/240 22K (1) 400A, 2P -- 30 MCC Part/UPC Catalog Connections Overall Dimensions Top Knockout umber umber Line Load eutral Height Width Depth Provision Layout 78205157072 U40411230MC Studs MC #6-250 MCM 38 30 6 one Fig. 1 78205157074 U40411230MCC Studs MC #6-250 MCM 38 30 6 one Fig. 1 78205119923 U4042208MC Studs MC #6-250 MCM 38 30 6 one Fig. 2 78205120682 U4042208MCC Studs MC #6-250 MCM 38 30 6 one Fig. 2 78205177210 U4042230MC Studs MC #6-250 MCM 38 30 6 one Fig. 1 78205177220 U4042230MCC Studs MC #6-250 MCM 38 30 6 one Fig. 1 78205177230 U404430MC Studs MC #6-250 MCM 47 34 6 one Fig. 3 78205177240 U404430MCC Studs MC #6-250 MCM 47 34 6 one Fig. 3 61

Meter Main Loadcenters - With Optional MCC ypass Style # Suffixes U404430 MC - o bypass U4042208 MCC - MCC bypass U4042230 SS - Stainless Steel * U40411230 Knockout Layouts Fig. 1 Knockouts - Conduit Sizes 1A = 1 2" 2 = 3 4" - 1 2" 2C = 1" - 3 4" 4D = 1 1 4" - 1-3 4" - 1 2" 4E = 1 1 2" - 1 1 4" - 1-3 4" = 2" - 1 1 2" - 1 1 4" - 1 = 2 1 2" - 2-1 1 2" - 1 1 4" = 4-3 1 2" - 3" 1W = 1 4" * Knockouts and top provisions are not available in Stainless Steel (SS) finish Fig. 2 2C 2 2C 2 4E 1A (6) 4D 1W (4) 4D 1A (xx) Fig. 3 2 (7) customer sides 1W (4) 1A 4E 1A (14) 2 2C 1W (4) 4D 62

Class 320 - Meter reaker Data Main reaker Data Catalog -Line ITE Ampacity # of AIC umber reaker # reaker # Poles U404MC/MCC 2556 JXD22400 400A 2P 22K U4042MC/MCC 25582A Q2200 200A 2P 10K U40411230MC/MCC 25585A MK200A 200A 2P 22K U4042230MC/MCC 25585A MK200A 200A 2P 22K U404430MC/MCC 2556 JXD22400 400A 2P 22K U4042208MC -- MK200A 200A 2P 22K U4042208MCC -- MK200A 200A 2P 22K reaker Provision Data Catalog -Line ITE Ampacity # of AIC umber reaker # reaker # Poles U40411230MC/MCC 25458P Q2100 100A 2P 10K U4042230MC/MCC 25464P Q2100H 200A 2P 22K 25582A Q2200 200A 2P 10K U4042208MC/MCC 25583A Q2200H 200A 2P 22K 25582A Q2200 200A 2P 10K 63

Class 320 - Wiring Diagrams A A U404MC U404MCC A A U4042MC U4042MCC A A U404223MC U404223MCC 64

Class 320 - Wiring Diagrams A A U404430MC U404430MCC A A U40411230MC U40411230MCC A A GROUD LUG GROUD LUG A A U4042208MC U4042208MCC 65