INSTRUCTIONS for the Model GVL GLASS-VU LOADER

Similar documents
Access Loader USER GUIDE UGC023/0305. Models AL2 and AL5

Access Loader with Easy Loading Control (ELC)

COMPRESSED AIR LOADER MODEL: AL-1

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

Chexit/RCM/DE5300. Chexit/RCM/DE5300 Service Parts. Chexit Field Wiring Cable. DE5300/RCM Field Wiring Cable. Table of Contents

Service & Maintenance

Techcon Systems TS500R-PC Controller For Positive Displacement PC Pump

INSTALLATION AND USER MANUAL

Model TC-20. Tube Cut-Off Machine. Operator s Manual REV H

Wolverine Turn Signal / Horn Kit 2102

DMR 3005 WM ONE ZONE WIRELESS DIMMER RECEIVER

Assembly Instructions

Oreck Magnesium Series Service Manual. The Oreck Manufacturing Company

WARNING. Important Notice

Vehicle Security System

WRANGLER 2016 WHEEL DRIVE, PAD ASSIST & ELECTRIC MODELS

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

PILLOWS DECK-MOUNT BATH FAUCET WITH FLUME SPOUT

MODEL ELC-12/40-CVM-D BATTERY CHARGER

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Installation and User Manual. with RAIN SENSOR.

3M Overhaul Service Kit

Turn Signal / Horn Kit PN 7101 by All years Polaris RZR 1000 and RZR 900, 900-4, 900 trail, 900S and 900XC STOP - THIS KIT IS DESIGNED

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

OWNER S MANUAL. ROTARY SURFACE CLEANER Models 105C, 105F, 105CW, & 105FW. Revision 2.01

INSTALLATION MANUAL

Universal Super Shield & Ultimate Aluminum w/electric Drive Conversion Kits , , Installation Instructions

Optima ETF-600/ETF-610

DustBeater. DB8 and DB12 Models with MLC6 Control U S E R G U I D E UGC

Digital II Pressure Control Module. Model IN64235 August Installation Instructions. Applicable addition manuals:

2016 HONDA 1000 Pioneer PN 3102 Turn signal / horn kit rev nc

Grundfos Variable Speed GRUNDFOS INSTRUCTIONS. Installation and Operation

PRODUCT INFORMATION BULLETIN

3M Overhaul Service Kit

AF0465-XX SERVICE KITS GENERAL DESCRIPTION MODEL DESCRIPTION CHART OPERATING AND SAFETY PRECAUTIONS THIS MANUAL COVERS THE FOLLOWING MODELS

IMS SERIES COMPRESSED AIR LOADER

Installation Instructions

Vehicle Security System

Strobe Light Kit. Stainless Steel Hopper Spreaders

MODEL ELC-12/60-D BATTERY CHARGER

Part Name/Description Part No. PF3000 PF 3000 Pro U-Bracket Short Bracket PF3000 Pro

Depress each tab as you pull the bezel off. The bezels are tight. L.H. shown.

Quickie S-11 Service Manual

ASSEMBLY INSTRUCTION MANUAL

RH INSTALL INSTRUCTIONS

E L E V E N C R O Z E R V I L L E R D. A S T O N, P A MODEL MLG "LITTLE GUY" CONCENTRATE AUGER FEEDER. with

PARTS LIST WRANGLER 2625 DB

PARTS LIST WRANGLER 2016 AE, AB, DB

920 Remote Control Switches

XS400 Load Bank. Read all instructions before using the load bank. Contents

Maintenance and Repair

Overview Spare Parts Manual Update: 3/11/04

Induction Power Supplies

SURE JET ENVELOPE FINISHING SYSTEM MODEL EFS

Page 1. File: Motolight caliper one-piece Date: 8/14/2006

OXYGEN GENERATING SYSTEMS INTL. Oxygen System Start-up, Overview and Maintenance Guide

POWER LOCK SYSTEMS 8P - 1 POWER LOCK SYSTEMS TABLE OF CONTENTS

Please read thoroughly before starting installation and check that kit contents are complete.

RH INSTALL INSTRUCTIONS 2008 MODEL

CABINET REEL OPERATING INSTRUCTIONS

Strobe Light Kit. Poly Hopper Spreaders with FLEET FLEX Electrical System

Ford Mustang V6 OEM-Style Fog Light Kit Parts List: Quantity: Tool List:

Model APS-25CH Installation Manual

(1) License Plate Light (2) License Plate Plugs

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

PARTS LIST WRANGLER 2625 DB

Industrial Turbo Meters, Sizes 2" through 6"

8400 Series Fiber Distribution System

TOYOTA PRIUS FOG LIGHT (Halogen or LED)

Installation Instructions 1812 Folder Disk Clutch Retrofit Kit Martin Yale #WRA

Type 2000 Transducer Product Instructions

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

ELECRAFT KX3 Application Note

ATP-2040 Electric Damper Actuator/Transmitter

Autosealer Hernon Manufacturing Autosealer

Installation Instructions

PACER 30 VACUUM IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE OPERATING OR SERVICING MACHINE

PACIFIC Recumbent Height-Adjustable Bath System Parts Breakdown and Assembly Manual

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

SERVICE AND REPAIR PARTS NEMA SIZE 3, SINGLE POLE, NORMALLY OPEN, P/N SERIES NEMA SIZE 4, SINGLE POLE, NORMALLY OPEN, P/N SERIES

Curb-Alert Installation Guide: C7 Stingray

Installation and Service Manual

HP Modular Cooling System 200/100 Options Installation Guide

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

ITEM QTY CHECK PART NUMBER DESCRIPTION

PITNEY BOWES FLEXIBLE INK JET TRANSPORT 36 FIT BASE: FIT-36. Parts Manual. (BOM: FIT36rev1.0) FIT-36parts_rev0 1

SIGNETMARINE. Livewell Bait Pump Alarm. No Dead Bait.

F479 HVE V PARTS LIST

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

igen2500 and ipro2500 IGNITION COIL RETROFIT GUIDE

Finding and Fixing Vacuum Leaks on the LT5 Engine Marc Haibeck

Service Manual Air Tech Second Stage

Model APS-25N Installation Manual

MODEL B ELECTRIC HYDRAULIC PUMP

WARNING Carefully Read These Instructions Before Use

DS1 Plug-In Digital Signal Cross-Connect (PIX-DSX-1) 19-Inch Shelf Kit Installation Instructions

Remove black panel shown. Save 6 retaining pins for re-install later. Pry up on center part of pin first. Then pry out entire retaining pin.

Porsche 911/996/997 Carrera Do-It-Yourself Convertible Top Hydraulic Cylinder Inspection, Removal and Shipping Instructions

PARTS LIST WRANGLER 2625 DB

Transcription:

INSTRUCTIONS for the Model GVL GLASS-VU LOADER Rev.7 06//5 Model: GVL-0 MAGUIRE PRODUCTS INC. Crozerville Road Aston, PA 90 USA 60-59-00

Installing the GVL GlassVu Loader ---General--- Electrical Connection Material Line Connections Orient lid opening for easy maintenance and cleaning Compressed Air Connection Fitting. Loader Control: see Loader Control Instructions for operation. Plastic Pellets Hold fitting with wrench. Lance inserted into material GVL Mounting Plate; see Mounting the GVL Loader. Mount the GVL-0 to your hopper. See drawing next page. Contact Maguire for available adapter plates.. Install material hose, secured with hose clamps at both ends, from the lance to material inlet tube of loader.. Install flexible compressed air line to the fitting and connect to clean, dry compressed air supply 80 psi. CAUTION: Use a second wrench to hold the fitting on the GVL secure while tightening the hose fitting.. Plug power cord into appropriate 0V power source.

Mounting the GVL Loader Contact Maguire Products for available adapter plates.

Operating the GVL GlassVu Loader --- General --- Plastic Pellets Press button to turn on loader and adjust load time with buttons. Assure that the feed tube is inserted into material Adjust conveying air with feed tube ring Vacuum motor should just fill glass section of loader and no more. GVL shown mounted on optional GVH GlassVu Hopper. Air inlet Too much air slow loading and hose wear more likely Too little air plugged material line is possible Good mixture of air and material Rotate to change air inlet opening The feed tube joins air with material and it should be plunged (and kept) in the material supply, but allow upper section of feed tube to remain above material level. Adjust load time. See next page for detailed instructions on control settings and options. To allow optimum loading and longest filter life, adjust load time and feed tube settings so that material flows into loader consistently and fills to top of glass. Filling the loader to a higher level will encourage premature filter blinding. Rotate the feed tube ring for the best air to material mixture. The best mixture of air and material will allow material to flow efficiently, with the right proportion of conveying air, without clogging and without rapid hose wear.

Loader Control Instructions LOAD TIME Increase (+) or decrease (-) seconds of vac motor time Chirp confirms change One press = one second Pressing both buttons during loading will use that time setting LOADER CONTROL See next page for details on special keystrokes for detailed programming without pendant. POWER* Press for On or Off Slow flash green = Power connected, unit turned off Steady green = On Fast flash green = Loading ALARM Red light and horn = Loading problem. Press silence button to turn off horn. Red light stays on until problem is solved or power button is pressed. Pressing silence button before alarm defeats alarm function. Yellow light = alarm is defeated * The power button enables or disables loading. Power is only disconnected by unplugging the power cord. Optional PENDANT Part Number: GVL-CP SELECT FUNCTION Button selects functions for viewing and/or changing. Selected function lights up, below. l5 Connector Cable Pendant may be disconnected after changes are made with no loss of settings. VIEW and CHANGE SETTINGS Value of the selected setting appears in window Increase (+) or decrease (-) values Display defaults to show ON Display shows AL for alarm condition LOAD TIME (in seconds) FILTER CLEANING Frequency and Number of pulses ALARM - Number of load reties before alarm ( 0 = alarm defeated) UNLOAD TIME (in seconds or minutes M) STANDARD FUNCTIONS PROPORTIONING LAYERS - Number of Proportioning Valve changes per load PROPORTIONING % of REGRIND Proportioning Valve is required for this function. PURGE TIME - Seconds for material line clearing. A purge valve is required for this function. OPTIONAL FUNCTIONS POWER* Press for On or Off Display shows ON * The power button enables or disables loading. Power is only disconnected by unplugging the power cord. 5

Making Detailed Control Changes Without The Use Of The Pendant The optional control pendant is the easiest way to make detailed changes to the loader control parameters, but changes are also possible with special keystrokes on the loader control itself, as described below:. Enter set-up mode by pressing +, - and at the same time.. Function selections are indicated by counting flashes of the yellow LED light (see list, below).. Hold and press either + or to move through the function list.. Once a function is selected, its values may be changed by pressing + or -. 5. Values of each function are indicated by flashes of the red light: A short flash = a value of A long flash = a value of 5 Example: a value of 6 = long flashes and one short flash. 6. Press to exit the set-up mode and return to normal operation. The Red LED flashes to indicate the value of the selected Function: Short LED Flash = Long LED Flash = 5 Green LED: Slow flash = Power connected, loader off On = Loader on, ready to load Fast flash = Loading (vacuum on) Loader Functions: 5 6 7 8 Load time (in seconds) Filter Cleaning pulses Alarm after # of load retries Unload (vacuum off) seconds Purge Time in seconds Proportioning % of Regrind Proportioning Layers Unload time (in minutes) The Yellow LED flashes to indicate the selected Function: Short LED Flash = Long LED Flash = 5 Yellow LED flashes: Short Flash Short Flashes Short Flashes Short Flashes Long Flash Long, Short Long, Short Long, Short 6

Description of Loader Functions Functions and Descriptions: Load time Set the load time to fill the glass chamber to the desired level. Load time can be set from to 60 seconds. Filter Cleaning Two-digit number. First digit is the frequency, which is the number of loads between cleaning the filter. Second digit is the number cleaning pulses that will be applied. Frequency ( st digit): Range 0 to 5 (0=after every load, 5=after every 5 th load) Number of Pulses ( nd digit): Range 0 to 5 (0=no cleaning, off) Alarm Number of load retries before alarm sounds. Number of retries can be set from 0 to 9. Zero turns off alarm. Unload Unload time in seconds Range to 59 seconds 5 Purge Time Purge time in seconds. Range 0 to 5 seconds. Optional purge valve is necessary to use this function. 6 Proportioning Is the adjustment of the % of Regrind. Range on loader controller: 0 to 0 (0 is 0%, 0 is 00%) Range on pendent: 0 to 00% by increments of 5%. V=0% Regrind, R=00% Regrind. Optional proportioning valve is necessary to use this function. 7 Proportioning Layers When set via the controller, the number of layers is 0 to 5 layers. When set via the pendent, the number of layers is A thru 5 layers. A = Number of layers automatically adjusted based on load time. Automatic range is from layers to layers. 8 Unload Time Unload time in Minutes Range to 9 minutes (Must set to zero to enter a value less than one minute in function ) 7

Filter Cleaning or Replacement. Disconnect the Blowback airline. Blowback Airline Disconnect.. Open the two butterfly latches and lift the lid. Remove the filter for cleaning or replacement. 8

Electrical Connection of Loading Options -Proportioning Valve -Purge Valve -Output to Auxiliary Alarm Device Printed Circuit Board Inside Control Box V GND 0 GND I7 V 0 All outputs are VDC Install wires from this side of terminal strip. I8 GND 0 0 05 V 06 Use flat blade screwdriver. Firmly tighten connections. Remote Alarm Relay Purge Valve Proportioning Valve PWR IN GND IN - + I8 GND 0 0-05 + + - Shield/ground wires on V 06 external devices should be grounded to control enclosure; not GND terminal. GND terminal is for input sensing devices ONLY.. Remove the screw from the top of the loader control enclosure, and carefully tip the enclosure out without straining wires connected to the control.. Locate the correct terminals for the device you are connecting, as shown above and connect the wires carefully. Use care as some terminals accommodate multiple wires.. Route the cable out of the control box, through one of the slots in the side. Tightly install a tie wrap (not included) onto the cable, inside the control enclosure to prevent the cable from being pulled out of the box.. Tip control box back into place and tighten top screw. 9 SPIN GND V ALM PUR V RAT

Accessing the Vacuum Motor for -Inspection of motor or power supply -Motor replacement -Brush replacement Loader Model GVL-0 For easiest service, the entire motor lid may be removed from the loader by first disconnecting the power cable from the supply and unplugging the round connector that connects to the loader control. Then remove the hinge bolt, freeing the lid to be removed from the loader body. Remove screws from the top and one screw on the front of the motor cover and remove the top cover plate (may require prying to separate the cover plate from the plastic motor shield). The motor, power relay and power supply are now exposed for inspection. The entire motor housing may be lifted away from the motor by lifting straight upward and sliding it along the smooth support shafts. A: Sleeves covering the support shafts will be drawn up and become loose when the motor housing is raised. These sleeves must be replaced when the motor housing is reassembled. B: For motor replacement and/or ease of service, the motor wires ( black wires, plus ground) should be disconnected, freeing the motor from the motor housing. C: Clearance slots in the lower panel of the motor housing allow the housing to be slipped around the protruding brushes and removed (the motor may require rotating to align the brushes with these slots). The motor is now separated from the lid and housing for service or replacement. To re-assemble, reverse steps thru above, but be sure the motor is properly centered and seated within the lower panel of the motor housing. Move motor as necessary to fit the motor ledge within the housing. Power supply Power relay 0

Replacing Motor Brushes Loader Model GVL-0 5 See Accessing the Vacuum Motor to remove cover from motor. Remove plastic shield from top of motor by squeezing the top of each spring clip (A) while prying the cover up away from colored brush holder (green-0 volts, red-0 volts). Cover can be worked up and off, one side at a time. Take care to not break small positioning stubs and grip tabs (B) on the plastic cover. Remove two black screws that hold down brush retaining clip. Once removed, brush will be released, but still connected to the short electrical lead. Use caution to avoid damaging the lead. Pry electrical lug out of the brush holder in the direction of the motor armature, taking care to not separate the wire from the lug. New brush may now be connected to the electrical lead by reversing this procedure. Push the lug firmly between the brass brush holder and its plastic housing. Reinstall new brush into motor housing and replace the retaining clip. Be sure to properly seat the nub on the bottom of the brush holder into the motor housing groove. A B 5 Repeat steps thru 5 for the adjacent brush. Replace the plastic shield on top of the motor by aligning it on top of the motor and pushing down until the spring clips on each brush snap into place. Reinstall cover over motor.

Spare and Replacement Parts Model: GVL-0 Note: Part numbers are case-sensitive 9 0 Part Description Lance Assy w/reg,.5 OD Vacuum Hose.5 ID* Hose Clamp Vacuum Motor 5 Volts* Vacuum Motor 0 Volts* Motor brushes 5 volts* Motor brushes 0 volts* Rubber gasket, lid to motor Motor cover (stainless grill) VDC Power Supply Solid State Relay for motor Fuse, 0A for 5 volts* Fuse, 5A for 0 volts* Multi pin connector (F) Lid gasket (under lid) Filter, Dacron disk, 7 7/8 OD* Filter Support Ring Butterfly latch () Segment ring (alum, T profile) Material Inlet Ring,.5 Glass gasket (top or bottom) Glass cylinder for GVL-0 Air Cylinder for discharge Discharge rubber gasket* Discharge valve top plate Solenoid, -way, VDC () GVL control printed circ board Coax Cable-5 feet w/ tie wrap* Control Pendant with cable* Diaphragm Valve, blowback Spring, blowback Part Number as7-nv tpvc hhc mm66 mm95 mb06 mb07 NL8-R NL8-0W ef7 ehr ez-0 ez06 epgm0 NR8-R hfdd8 NR8-0R hl09 NR8-8 asnl8-0 rpl-6- NR8-G6 ncy-p NR8-R NR8- nv50-d eabnl-0 ehcx5 GVL-CP NL8-5 hs # 5 6 7 8 9 0 5 6 6b 7 8 9 0 5 6 9 0 7 5 6 7 8 5 6 6b 8 9 0 5 6 9 * Recommended Spares 0 See alternate prints/manuals to find parts for associated equipment or options