SQUARE INLINE CENTRIFUGAL FANS

Propeller Hooded Roof Fans

CONSTRUCTION FEATURES AND OPTIONS

Industry best 5 year fan housing warranty, 1 year motor warranty

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

Square Inline Fans with Multi-Directional Discharge

Centrifugal Roof Downblast Exhaust Fans

Roof Upblast and Sidewall Exhaust

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

Propeller Upblast Roof Fans

Filtered Kitchen Supply Packaged Ventilator

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

Downblast Centrifugal Fans with ECM

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

Centrifugal Roof Downblast Exhaust Fans

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

forward curved inline duct blowers

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

EcoWatt Products. Advancing Ventilation

Tube Axial Inline Fans

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

Direct Gas-Fired Heating

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

CEILING & INLINE/CABINET VENTILATORS

DESIGN GUIDELINES FANS PAGE 1 of 7

Centrifugal Spun Aluminum Products

Centrifugal Utility Fans - SFD/SFB

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

Industry best 5 year fan housing warranty, 1 year motor warranty

Centrifugal Spun Aluminum Products

LINEA Low Discharge Roof Exhausters

DIrect drive exhaust & supply panel fans

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Inline and Roof Mounted Fans

Industry best 5 year fan housing warranty, 1 year motor warranty

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

Centrifugal Filtered Supply Roof Blowers

ceiling & inline/cabinet ventilators

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Multi-Port Centrifugal Fans for Round Duct

Centrifugal Roof Downblast Exhaust Fans

Fixed Pitch Vane Axial Fan

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

Centrifugal Upblast Power Roof Ventilators

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

Centrifugal Spun Aluminum Products

SECTION AXIAL HVAC FANS

Twin City Fan & Blower

Tube Axial Fan Page Specifications & Dimension Data Performance Data

SECTION CENTRIFUGAL HVAC FANS

VANEAXIAL & TUBEAXIAL FANS

MODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN

MODEL FF50 CEILING FAN

Hybrid Fans. Models QEI and QEID. Belt and Direct Drive

High Performance Axial Fans

Tamper Proof Downblast Centrifugal Exhaust Ventilators Page

Mixed Flow Inline Fan Model EQB

FILTERED SUPPLY CENTRIFUGAL Belt Drive

K SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS

Mixed Flow Inline Fan, Model MFSI

MODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

CONSTRUCTION FEATURES

Centrifugal Utility Fans Model SFD, SFB, SWD and SWB

Model: G-143-VG. CAPS Z:\Carl\winjobs\Alley 111.gfcj Page 6 of 18

Centrifugal Utility Fans

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

Belt Drive Centrifugal Roof Exhauster Model PV

Twin City Fan & Blower

MODEL NBRTD BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

TUBULAR CENTRIFUGAL INLINE FANS

Vane Axial Fans Models VAB and VAD. Belt and Direct Drive

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

Laboratory Exhaust Systems

Safety disconnect. switch is optional. Belt drive with adjustable motor pulley provides flexibility to match operating requirements.

Axial Propeller Panel Fans, PAF-Series

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

DF / DFB / DFC DOUBLE WIDTH DOUBLE INLET FORWARD CURVED FANS

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

Transcription:

Centrifugal Inline s Models SQ and BSQ Direct and Belt Drive May 21

Models SQ and BSQ Centrifugal Square Inline Duct s Table of Contents Standard Construction Features...4-5 Vari-Green Motor & Control Options... 6-7 Options and Accessories...8 Filter Options...9 Discharge Configurations....1-11 Mounting Options....12 Isolators...1 Typical Installation...14 Model Number Code...14 Direct Drive....15-2 Belt Drive...24-45 Specifications....46-47 Quick Delivery...48 Our Commitment...48 Greenheck Corporation certifies the model SQ and BSQ fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and Publication 11 and comply with the requirements of the AMCA Certified Ratings Program. The certified ratings for models SQ and BSQ are shown on pages 15 to 45. UL is optional and must be specified. SQ and BSQ models are Listed for Electrical (UL/cUL 75) File no. E41 Models SQ 1 and greater. Models BSQ 7 through BSQ 42 For a CE compliant installation, all electrical connections must be made by a qualified electrician. 2

Models SQ and BSQ Centrifugal Square Inline Duct s Model Comparison Location Mounting Airflow Application Drive Type Impeller Type Performance Model Outdoor Indoor Roof Curb Base/Floor Hanging Wall Ceiling Mounted Exhaust Supply Reversible Recirculate General/Clean Air Contaminated Air Spark Resistant Grease (UL 762) Smoke Control (UL) High Wind (15 mph) High Temp (above 2 F ) Belt Direct Centrifugal Propeller/Axial Mixed Flow Maximum Volume (cfm) Maximum Static Pressure (in. wg) Relative Cost SQ 5, 2 $ BSQ 27,2 4 $ Greenheck s model SQ and BSQ centrifugal inline fans feature a unique combination of installation flexibility, rugged construction, ease of service, high efficiency and low sound levels. These compact inline fans are the ideal selection for indoor clean air applications including intake, exhaust, return or make-up air systems where space is a prime consideration. The need for costly square-to-round transition pieces is eliminated reducing installation costs. The square housing design, compact size and straight-thru airflow also give the system designer the flexibility to mount SQ and BSQ fans in any configuration - horizontal, vertical or at any angle. Broadest performance in the industry, up to 4 in. wg (1, Pa) and 28, cfm (47, m /hr). Performance as cataloged is assured. All fan sizes are tested in our AMCA Accredited Laboratory, and all models are licensed to bear the AMCA Sound and Air Performance seals. UL Listed for Electrical. These Greenheck products are subjected to extensive life testing to assure the fans will provide many years of reliable performance. Over the years Greenheck has listened to your needs and input to remain the industry leader. Each fan is tested at the factory prior to shipping. The test includes vibration check, adjusting and maximum amp draw. Each fan displays a permanently stamped metal nameplate with complete model number, mark and unique serial number for future identification. Packaged-product is tested in accordance with ISTA (International Safe Transit Association) standards and procedures. Turn to our inline fans to meet your requirements for applications in office buildings, schools and hospitals to name a few.

Standard Construction Features Model SQ Direct Drive 5 4 1 2 Model BSQ Belt Drive 5 9 2 4 7 8 6 1 4

Standard Construction Features 1 Cabinet Construction The fan housing is constructed of rigid structural members and formed galvanized steel panels. (Aluminum construction is optional in SQ sizes 6-16 and in BSQ sizes 7-). 2 Drive Frame Constructed from heavy-gauge steel. Wheel An aluminum, backward inclined, nonoverloading centrifugal wheel is utilized to deliver maximum efficiency. Each wheel is statically and dynamically balanced. 4 Duct Collars Inlet and discharge duct collars are provided for easy duct connection. The square design provides a larger discharge area than tubular centrifugal and vane axial fans; outlet velocities are reduced for quieter operation. 5 Motor Permanently lubricated, sealed ball bearing motors are selected to provide years of trouble-free operation with minimal maintenance. 6 Bearings 1 percent factory tested bearings are designed specifically for air handling applications with a minimum L 1 life in excess of 1, hours (L 5 average life in excess of 5, hours). 7 8 9 Drive Assembly Drives are sized for a minimum of 15 percent of driven horsepower. Machined cast iron pulleys are factory set to the required and adjustable for final system balancing. Belts are static free and oil resistant. Belt adjustment is accomplished by loosening fasteners, sliding the motor plate and retightening fasteners. Shaft shafts are precisely sized, ground and polished so the first critical speed is at least 25 percent over the maximum operating speed. Close tolerances where the shaft makes contact with bearings result in longer bearing life. Disconnect Switch NEMA-1 disconnect switch is factory-mounted and wiring is provided from the motor as standard. All wiring and electrical components comply with the National Electric Codes and materials are UL Listed. Other NEMA enclosure disconnect switches are optional. Access Panels (not shown on images) The cabinet construction features two removable access panels permitting easy access to all interior components. 5

Vari-Green Options Vari-Green Motor - Model SQ Greenheck s electronically commutated (EC) Vari-Green (VG) motor combines motor technology, controllability and energy-efficiency into one single low maintenance unit and is the industry s first fully controllable motor. When combined with Greenheck s SQ fans, all the CFM and static pressure ranges of a belt drive can be attained with the benefits of a direct drive. The Vari-Green motor is available in: 1/6 - /4 horsepower 115 volt only. 1 horsepower 115/28-2 volt. 2 horsepower 28-2 volt. All motors are available in a 5/6 Hz power. Benefits Operates on AC power that s converted to DC providing a more efficient motor operation as compared to an AC operation. The motor can attain up to 85% efficiency and reduce energy consumption. Watt savings of -7% depending on. Note: As motor speed is turned down, efficiency stays high as compared to an AC motor that decreases dramatically. Operates cooler than a standard AC motor at lower s. A cooler motor has longer motor life and reduces energy consumption. 8% usable turndown vs. %. (chart at right) SQ fans with Vari-Green motors can provide all the CFM and static pressure ranges of a comparable belt drive. Maintenance costs are reduced as there are no belts or bearings to replace and no pulleys to adjust. Direct drive fans are often preferred where maintenance access is difficult. Provides a solution for demand controlled ventilation applications. Vari-Green Advantages Initial cost is similar to a belt drive Lower operating cost No maintenance, no belts, pulleys or bearings Easy adjustment Features 1. Dial on Motor Control - A potentiometer (dial on motor control) is mounted on the motor for easy speed adjustment for system balance. Simply turn the dial; there are no belts and pulleys to adjust. 2. Control Wire Inputs - the motor accepts a -1 VDC signal from Building Automated Systems, Vari-Green Controls or other controls to adjust motor speed. Motor Turndown Comparison INPUT POWER (WATTS) 1 Comparisons: Belt, Direct Drive with PSC and Direct Drive with Vari-Green 6 5 4 2 1 5 BSQ-12 Single Phase* 5% 75% 1% SQ-12 with PSC Not recommended Energy Savings SQ-12 with FAN SPEED () * BSQ is a belt driven fan The length of each curve indicates the practical turndown range. Data is for 1/2 hp motors with load of.5 Bhp at full speed Constant Volume Life Cycle Analysis $2,5 2,25 2, 1,75 1,5 1,25 1, 75 5 25 $ Three Year Cost Comparison BSQ- 12 SQ- 12-A5 Initial Cost Maintenance cost over three years Operating cost over three years SQ- 12-VG 2 175 Analysis is based on operating costs for a period of three years where the fans operate continuously at 1725 rpm, 24/7, with an energy rate of $.1/kWh. Maintenance on the SQ-12 is estimated at $65/yr. Note: Example is based on a relative cost. Use and installation variables may produce different results. 6

Vari-Green Options Demand Control Ventilation for Multistory Buildings Applications requiring constant pressure or variable volume can utilize SQ fans with Vari-Green motors and Vari-Green controls. Demand control ventilation systems reduce the amount of energy used by decreasing the speed of the fan when demand is low. This in turn lessens the amount of conditioned air exhausted and further reduces total operating costs associated with air conditioning and heating in multistoried buildings such as: hotels, multifamily complexes, institutional facilities, and high rise commercial buildings. Variable Volume Operating Cost Analysis Variable Volume vs. Constant Volume $2, 1,75 1,5 1,25 1, 75 5 25 $ Variable Volume Heating Cost Cooling Cost Operating Cost Constant Volume Example of potential savings based on a northeast city in the USA using Vari-Green components for variable volume. The Vari-Green constant pressure control is preprogrammed and easy-to-install for applications that include: venting dryers, bathrooms, residential type kitchen space or industrial process exhaust. Contact fans@greenheck.com for more information. Daily Operating Comparison: Variable Volume and Constant Volume % of Operation % of Operation Hypothetical (Hotel Bathroom) Variable Volume - Load Shape 1 8$$$$$$$$$$$$$$$$$$$$$$$$ 6$$$$$$$$$$$$$$$$$$$$$$$$ 4$$$$$$$$$$$$$$$$$$$$$$$$ 2$$$$$$$$$$$$$$$$$$$$$$$$ % $$$$$$$$$$$$$$$$$$$$$$$$ 1 2 4 5 6 7 8 9 1 11 12 1 14 15 16 17 18 19 2 21 22 2 24 Series 1 Time of Day Demand controlled ventilation offers significant energy savings by exhausting only the necessary amount of air throughout the day. Constant Volume - Load Shape 1 8 6 4 2 % 1 2 4 5 6 7 8 9 1 11 12 1 14 15 16 17 18 19 2 21 22 2 24 Series 2 Time of Day Note: A standard VFD compatible motor can also function within a variable volume system. Vari-Green Controls Transformer - Provides 24V power from the existing line voltage at the fan to the Vari-Green motor and controls. Dual voltage primary (12/24V) transformer provided with the fan. Remote Dial - Allows for remote, manual airflow adjustments. Wall plate with dial may be mounted in a standard 2x4 inch electrical junction box. Two Speed Control with Integral Transformer Control allows motor rpm to be set at two independent speeds (high or low). Meets minimum airflow requirements with the ability to bump up to high speed in an emergency or meet maximum airflow requirements, or reset to low for energy conservation. Constant Pressure Control - Indoor - Control Vari- Green motor via static (variable volume) or velocity (constant CFM) pressure on the inlet or outlet side of the fan. Optional, one or two, duct or room probes for use in: Multifamily structures - Apartments, condos, hotels; dryers, residential kitchens and bathrooms. Institutional facilities - Schools, prisons, multistory office buildings; bathrooms. Constant Pressure Control - Outdoor Control Vari-Green motor via static pressure on the inlet side of the fan. Includes one duct probe and transducer for use in: Multifamily structures - Apartments, condos, hotels; residential kitchen, dryer facilities and bathrooms. Institutional facilities - Schools, prisons, multistory. Air Quality VOC - Control a Vari-Green motor via changes in volatile organic compounds (VOC s). VOC s are gasses that are emitted from humans, building materials, perfumes, foods, and furniture off-gassing. Range is -2 CO 2 ppm equivalent. Institutional facilities Schools, court house, hospitals; bathrooms, waiting rooms, cafeteria. Commercial buildings Office space, conference rooms, bathrooms, break room. Air Quality Temperature and Humidity - Control Vari-Green motor via changes in temperature, humidity, or both. Range is 2 to 12 F and to 1% relative humidity. Multifamily structures Apartments, condos, hotels; bathrooms, utility rooms. Commercial buildings Office buildings; office space, conference rooms, utility rooms, bathrooms. 7

Options and Accessories ALUMINUM CONSTRUCTION - Aluminum construction is available for all direct drive sizes 6-16 and belt drive sizes 7-. Some drive frame components may still be of galvanized construction to maintain structural integrity. INLET AND OUTLET GUARDS - Inlet and outlet guards provide protection for non-ducted applications. Guards are fabricated of welded wire on a galvanized steel frame. They are easily removed for maintenance and inspection. BELT DRIVE MOTOR COVER AND BELT GUARD - For belt-driven fans, combination motor cover and belt guards constructed of galvanized steel are available for protection of motors, drives and personnel. Standard on units specified with UL. DIRECT DRIVE MOTOR COVER - Formed, galvanized steel motor covers are available to isolate direct drive motors from the airstream. When motor covers are furnished, vents to the exterior of the fan are provided to ensure sufficient motor cooling. INSULATED HOUSING - For noise reduction and condensation control, the interior of the fan housing can be lined with a 1-inch fiberglass duct liner. The optional motor cover can also be insulated. The table depicts the radiated sound reduction that can be obtained in each octave band for the insulated housing and motor cover together. Approximate Radiated Sound Attenuation (db) Octave Band 1 2 4 5 6 7 8 Sizes 6-1 -2-7 -4-4 -6-1 -1-9 Sizes 14-42 - -2-5 -4-5 -5-7 -8 BACKDRAFT DAMPERS - Gravity or motorized parallel blade dampers (model WD-) are available for duct mounting. These dampers feature sturdy galvanized frames, aluminum blades with vinyl blade seals, and a balanced design for minimal resistance to airflow. CONTROL DAMPERS - Square, opposed blade volume control dampers (model VCD) are available for duct mounting. These dampers feature sturdy galvanized frames, and steel blades with optional blade and jamb seals. A balanced design results in minimal resistance to airflow. INLET VANE DAMPERS - Variable inlet vane dampers (model IVDE) are available for models SQ and BSQ sizes 14-42 and are factory-assembled to the fan. They can be specified for either manual or automatic operation (controls furnished by others). These dampers are constructed of heavy-gauge steel and feature uniform blade movement for positive control. Companion inlet rings for round duct connections are also available. SPEED CONTROLLERS - Available for use with shaded pole and permanent split capacitor (PSC) motors on model SQ fans. They provide an economical means of system balancing with direct drive fans. MOTOR STARTERS - The fundamental function n of a motor starter is to protect the motor from damage that can occur from overheating. With a Greenheck motor starter, you will be provided with the best motor protection available. Specific model components may include; SmartStart technology, physical interface, overload protection, disconnect, magnetic contactor, NEMA-1 or NEMA-R steel enclosures and pre-engineered easy system integration. For complete information on specific Greenheck Motor Starter models refer to greenheck.com, Products, Motor Starter page. WIRING PIGTAIL - Allows direct hook-up to the power supply eliminating field wiring at the fan. COATINGS - Wide variety of coatings and colors are available. Decorative coatings are available in sixteen standard colors. Protective coatings are available in a choice of five electrostatic applied powders providing an available selection for most environments. All Greenheck coatings and resistance charts can be found in our Performance Coatings for Commercial & Industrial s brochure. 8

Filter Options The filter box is designed to provide a compact and convenient clean air solution. Factory-assembled as a single unit, this fan eliminates the costly process of designing, fabricating and installing special remote filter box assemblies. Both the fan and filter section feature removable access panels on both sides to remove and replace filters, making fan maintenance simple and fast. Model Selection Procedure 1. Calculate system pressure drop and cfm requirements (not including filters). 2. Make a preliminary model size selection.. Calculate a filter pressure drop (P) for the preliminary cfm model size selected in step 2 using the equation: P = F x ( 1, ) 2 To determine the filter factor (F) refer to chart below. 4. Add the filter pressure drop (P) to the system pressure drop and make a revised model size selection. Model Model SQ Model BSQ Size 6-75 8-95 1 12 1 14 16 7-8 - 9 1 12 1-1 14-14 16-16 18-18 2-2 24-24 - 6-6 42 Filter Box Weight 4 (18) 74 (4) 88 (4) 114 (52) 12 (54) 174 (79) 246 (112) 117 (5) 12 (54) 144 (79) 14 (64) 181 (82) 294 (1) 44 (156) 441 (2) 57 (26) 759 (44) 957 (44) 1185 (58) Filter Size 1 x 12 (254 x 5) 14 x 25 (56 x 65) 16 x 2 (46 x 58) 16 x 25 (46 x 65) 2 x 2 (58 x 58) 2 x 25 (58 x 65) 2 x 2 (58 x 58) 14 x 25 (56 x 65) 16 x 2 (46 x 58) 16 x 25 (46 x 65) 2 x 2 (58 x 58) 2 x 25 (58 x 65) 2 x 2 (58 x 58) 2 x 25 (58 x 65) 12 x 25 (5 x 65) 16 x 25 (46 x 65) 2 x 25 (58 x 65) 16 x 25 (46 x 65) 2 x 25 (58 x 65) 16 x 25 (46 x 65) 2 x 25 (58 x 65) 16 x 25 (46 x 65) 2 x 25 (58 x 65) Filter Quantity Aluminum Note: 24-inch side clearance is recommended for accessing and removing filters. All dimensions in inches (millimeters) and weight in pounds (kilograms). Filter Factor (F) 1 inch (25) 2 inch (51) Paper Filters (MERV 7) Aluminum Paper Filters (MERV 8) 1 186 18.6 251.1.18 1 21.8 7.28 29.4 5.5 2 8.72 14.91 11.77 14.21 2 5.58 9.54 7.5 9.1 2 5.58 9.54 7.5 9.1 2.57 6.11 4.82 5.82 4 2.9.57 2.82.41 1 21.8 7.28 29.4 5.5 2 8.72 14.91 11.77 14.21 2 5.58 9.54 7.5 9.1 2 5.58 9.54 7.5 9.1 2.57 6.11 4.82 5.82 4 2.9.57 2.82.41 4 1.4 2.29 1.81 2.18 4 4.77 1.2 1.4 1.26.41.7.55.67 8..56.45.54 1 5 5 1.15.26.2.25.1.22.18.21 9

Discharge Configurations The side discharge option helps to reduce system effect. It will increase performance and reduce installation labor. The most notable is reducing system effects. Note: The figure 1 example shows the air being discharged into the corner. It will take several duct lengths before the airflow becomes laminar or smooth again after making the turn. In figure 2, the fan is placed in the corner using a side discharge. In this configuration the air flow pattern at discharge is smooth and supports a more predictable system. Remember the duct length on the discharge side, should be approximately two to three wheel diameters to achieve catalog performance. Discharge Configuration performance will change with different discharge positions. Catalog data is based on an inline discharge. Right side discharge will give you 18% of cataloged performance and left side will give you 19% of cataloged performance. Use figure to locate the orientation to fit your application. Figures 4 and 5 on page 11, illustrate the proper side discharge definitions. Refer to Greenheck s CAPS (Computer Aided Product Selection) program or consult factory for performance modifications. Left Discharge Left, Right & Inline Discharge Figure 1 Right Discharge Left & Right Discharge Figure 2 Figure 1

Side Discharge SQ Side Discharge BSQ Side Discharge Left Side Discharge Access Door Inline Discharge Left Side Discharge Access Door Inline Discharge Figure 4 Height Figure 5 Height Inlet Width Right Side Discharge Inlet Width Right Side Discharge SQ Side Discharge Duct Openings Unit Size Width Height 6-75 9 7 8 (251) 8 7 8 (225) 8-95 12 7 8 (27) 11 7 8 (2) 1 1 7 8 (52) 1 7 8 (52) 12 15 7 8 (4) 15 7 8 (4) 1 17 7 8 (454) 17 7 8 (454) 14 19 7 8 (55) 19 7 8 (55) 16 22 7 8 (581) 22 7 8 (581) All dimensions in inches (millimeters). BSQ Side Discharge Duct Openings Unit Size Width Height 7-8-9 11 7 8 (2) 11 7 8 (2) 1 1 7 8 (52) 1 7 8 (52) 12 15 7 8 (4) 15 7 8 (4) 1-1 17 7 8 (454) 17 7 8 (454) 14-14 19 7 8 (55) 19 7 8 (55) 16-16 22 7 8 (581) 22 7 8 (581) 18-18 2 7 8 (66) 2 7 8 (66) 2-2 27 7 8 (78) 27 7 8 (78) 24-24 28 7 8 (7) 4 7 8 (886) - 1 7 8 (81) 41 7 8 (164) 6-6 2 7 8 (85) 48 (1219) 42 4 7 8 (886) 5 4 (1114) All dimensions in inches (millimeters). 11

Horizontal and Vertical Mounting Options All SQ and BSQ fan models can be mounted horizontally, vertically or at an angle. For ease of installation, knockouts are provided at each location where mounting brackets are shown in figures 6, 7 and 8. Optional brackets are universally adjustable to mount in any of these locations. A A C F E E A A C A G B NOTE: Hanging rails by others B A F E B Figure 6 Horizontal Hanging or Base Mount With either a hanging or base mount the motor may be located on either side. The base mount allows top access panels only. F E A G B A A C A F E C Figure 7 Horizontal Hanging or Base Mount With a hanging mount, the motor may be located on either top or bottom. The base mount allows top motor location only. Both options provide access panels on two sides. D G B NOTE: Hanging rails by others D G B Figure 8 Vertical Hanging or Base Mount Mounting brackets are turned 9 degrees for vertical mounting. Access panels are located on the two sides adjacent to the motor. B D B D Model A B C D E F G SQ 6-75 1 5 8 (27) 17 (42) 15 4 (4) 8 7 8 (225) 19 4 (52) 7 (178) SQ 8-95 1 1 4 (7) 2 (58) 18 4 (476) 11 7 8 (2) 4 (192) 27 8 (695) BSQ 7-9 18 5 8 (47) 2 1 8 (511) 18 4 (476) 11 7 8 (2) 48 5 16 (1227) 27 8 (695) SQ-BSQ 1 18 5 8 (47) 22 1 8 (562) 2 4 (527) 1 7 8 (52) 44 7 8 (114) 24 (61) SQ-BSQ 12 18 5 8 (47) 24 (61) 22 4 (578) 16 (46) 49 8 (1254) 28 1 8 (714) SQ-BSQ 1 18 5 8 (47) 26 1 8 (664) 24 4 (629) 17 7 8 (454) 44 (1118) 2 (584) SQ-BSQ 14 19 5 8 (498) 28 1 8 (714) 26 4 (679) 19 7 8 (55) 5 1 16 (1272) 28 (711) SQ-BSQ 16 2 1 2 (597) 1 (787) 29 4 (756) 22 7 8 (581) 49 5 8 (126) 2 5 8 (6) BSQ 18 25 1 2 (648) 1 2 (851) 29 9 16 (751) 22 4 (578) 52 9 16 (15) 24 1 2 (622) BSQ 2 29 1 8 (74) 7 (94) 4 (857) 26 4 (679) 64 16 (16) 2 1 4 (819) BSQ 24 1 5 8 (8) 44 1 4 (1124) 4 4 (15) 7 8 (86) 66 1 2 (1689) 2 1 8 (816) BSQ 5 (889) 51 (1295) 47 4 (121) 4 7 8 (18) 69 1 8 (1756) 1 8 (797) BSQ 6 8 4 (974) 57 1 4 (1454) 5 1 2 (159) 46 4 (1187) 76 (19) 4 11 16 (881) BSQ 42 47 1 8 (1197) 6 (16) 59 7 8 (1521) 59 7 8 (1521) 9 1 2 (2299) 4 1 2 (129) All dimensions in inches (millimeters). Hanging rails not included. Supplied by others. Hanging rails not included. Supplied by others. 12

Base Mount or Hanging Isolators J H L Standing Neoprene Isolator Complete isolation kits are available with either neoprene or spring isolators and are sized to match the weight of the specified fan size. The base isolator support brackets are designed to permit mounting of the fan with the motor located on top or either side. The hanging isolator support brackets are designed to permit mounting of the fan with the motor located on top, bottom or side. J Standing Spring Isolator Note: Hanging rods to be supplied by others. 5 8 inch (16 mm) nominal H I Model H I J K L SQ 6-75 SQ 8-95 BSQ 7-9 SQ-BSQ 1 SQ-BSQ 12 SQ-BSQ 1 SQ-BSQ 14 SQ-BSQ 16 1 8 (5) 5 1 2 (14) 2 (51) 6 4 (171) 2 5 16 (59) H Hanging Neoprene Isolator BSQ 18 BSQ 2 BSQ 24 BSQ BSQ 6 BSQ 42 1 8 (5) 5 1 2 (14) 2 (51) All dimensions in inches (millimeters). 6 4 (171) 2 5 8 (67) J Hanging Spring Isolator K H J 1

Typical Installation Models SQ and BSQ ducted inline fans are designed for the exhaust, supply or recirculation of air in a building. Typical installation requires ductwork on the inlet and outlet side of the fan. A minimum of three duct diameters is required on the inlet and outlet of the fan to minimize system effect losses. See the diagram below for a typical installation. Installations can include flexible duct connections (by others) on either the inlet or outlet side of the fan or both. The motor is rigidly mounted and can be oriented in any direction (top, bottom, side). The model BSQ ducted inline fan must be installed with the motor accessible for maintenance and inspection. External isolators are recommended, hanging (shown below) or base mounted. Installation must meet all local governing codes and the NEC. Flexible duct (by others) Wheel Diameters Wheel Diameters Model Number Code The model number system is designed to completely identify the fan. The correct code letters must be specified to designate belt or direct drive. The remainder of the model number is determined by the size and performance selected from the following pages. BSQ - 12 - VG/5/A MODEL CONFIGURATION BSQ - Belt Drive Inline Exhaust SQ - Direct Drive Inline Exhaust FAN SIZE 6 through 42 PRESSURE LEVEL (Belt Drive Only) - High Pressure Wheel VG = Vari-Green (Direct Drive only) MOTOR (Belt Drive only) 6 = 1/6 7 = /4 = 4 = 1/4 1 = 1 5 = 5 = 1/ 15 = 1 1 2 75 = 7 1 2 5 = 1/2 2 = 2 1 = 1 MOTOR (Direct Drive only) A = 1725 D = 155 B = 114 E = 15 C = 86 G = 1 International (See CAPS for performance) K = 95 J = 1475 14

SQ 6-65 - Direct Drive 8 7 8 (225) 1 (25) 12 (5) 1 () 12 (5) Damper size = 9 x 9 (229 x 229) Unit weight** = 26 (12) Outlet velocity = 1.828 x cfm Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Static Pressure (Pa) 1 12 11 1 9 8 7 6 5 4 2 1 Static Pressure (in. wg).55.5.45.4.5..25.2.15.1.5 65-VG 65-D 65-G 6-E 6-VG 6-D 6-G 65-E. 5 1 15 2 25 Volume (cfm) 5 1 15 2 25 5 4 45 5 Volume (m /hr) (Direct) (Vari Green) Density.75 lb/ft Density 1.2 kg/m Motor Direct..5.1.125.15.2.25..5.75 6 CFM 126 12 79 6 42 VG-1/6 E-1/14 15 B.1.1.1.1.1 Sones 1.7 1.7 1.7 1.7 1.8 CFM 156 16 118 11 99 7 7 G-1/8 1 B.1.1.1.1.1.1.1 Sones 2.9 2.7 2.7 2.6 2.6 2.5 2.5 CFM 186 168 15 146 18 12 15 78 48 2 D-1/4 155 B.2.2.2.2.2.2.2.2.2.2 Sones 4. 4.1.9.9.9.9 4. 4. 4.1 4.1 CFM 27 191 177 17 16 15 16 12 98 85 1725 B.2......... Sones 5.4 5.2 5.1 5. 5. 5.1 5.1 5. 5.5 5.6 65 CFM 154 129 98 79 57 VG-1/6 E-1/1 15 B.1.1.1.1.1 Sones 2.2 2.1 2. 2. 1.9 CFM 191 172 15 17 12 92 52 G-1/5 1 B.1.1.2.2.2.2.2 Sones.2.1. 2.9 2.9 2.9 2.8 CFM 228 21 194 185 175 15 129 11 66 46 D-1/ 155 B.2.2........2 Sones 4.9 4.8 4.5 4.4 4. 4.1 4..9.7.6 CFM 254 242 224 216 27 19 17 148 124 111 1725 B....4.4.4.4.4.4.4 Sones 6.4 6.1 5.8 5.7 5.5 5. 5.2 5. 4.8 4.7 Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are 15

SQ 7-75 - Direct Drive 8 7 8 (225) 1 (25) 12 (5) 1 () 12 (5) Damper size = 9 x 9 (229 x 229) Unit weight** = 26 (12) Outlet velocity = 1.828 x cfm Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Static Pressure (Pa) 12 1 8 6 4 2 Static Pressure (in. wg).55.5.45.4.5..25.2.15.1.5 7-G 75-E 7-E 75-G 75-VG 7-VG 75-D 7-D (Direct) (Vari Green) Density.75 lb/ft Density 1.2 kg/m. 5 1 15 2 25 5 4 Volume (cfm) 1 2 4 5 6 Volume (m /hr) Motor Direct..1.125.15.2.25..5.75.4 7 CFM 212 141 119 87 VG-1/6 E-1/1 15 B.1.1.1.1 Sones 2.7 1.7 1.5 1.5 CFM 26 25 191 176 14 77 G-1/5 1 B.2.2..2.2.2 Sones 4.1.4..1 2.9 2.5 CFM 1 265 252 24 216 19 155 99 67 D-1/ 155 B......... Sones 5.6 5.2 5.1 5.1 4.9 4.7 4.5 4.2 4. CFM 48 6 295 28 262 24 216 187 171 148 1725 B.4.4.4.4.4.4.4.4.4.4 Sones 6.8 6.7 6.6 6.6 6.5 6.4 6.2 6. 5.9 5.8 75 CFM 241 167 147 124 VG-1/6 E-1/1 15 B.1.1.1.1 Sones.6 2.9 2.8 2.6 CFM 299 29 225 29 176 1 G-1/5 1 B.2.2.2.2.2.2 Sones 4.1.7.7.7.6.5 CFM 56 7 294 282 257 229 22 165 17 99 D-1/ 155 B...4.4.4.4.... Sones 6.1 5.5 5.4 5. 5.1 4.9 4.9 4.8 4.8 4.8 CFM 96 5 41 7 285 26 25. 22 26 1725 B.4.5.5.5.5.5.5.5.5.5 Sones 8. 7.2 7. 6.8 6.5 6.2 6.1 6. 6. 6. Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are 16

SQ 8-85 - Direct Drive 11 7 8 (2) 1 (25) 15 (81) 16 (46) 15 (81) Damper size = 12 x 12 (5 x 5) Unit weight** = 41 (19) Outlet velocity = 1.21 x cfm Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Static Pressure (Pa) 18 16 14 12 1 8 6 4 2 Static Pressure (in. wg).8.7.6.5.4..2.1 8-D 85-G 8-G 85-E 8-E 8-VG 85-D 85-VG. 1 2 4 5 6 Volume (cfm) 2 4 6 8 1 Volume (m /hr) (Direct) (Vari Green) Density.75 lb/ft Density 1.2 kg/m Motor Direct..1.125.2.25..75.4.45.5 8 CFM 6 241 225 167 15 VG-1/6 E-1/4 15 B.1.1.2.2.2 or 1/4 Sones.8.7.6.8 4.1 CFM 79 25 1 274 244 211 14 G-1/2 1 B.2...... Sones 5.4 5.4 5.4 5.4 5.4 5.4 5.5 CFM 452 45 95 64 4 19 28 266 28 21 D-1/12 155 B.4.4.4.5.5.5.6.6.6.6 Sones 7. 7. 7. 7. 7.2 7. 7. 7.4 7.5 7.6 CFM 5 461 451 42 44 85 54 42 19 294 1725 B.5.5.5.6.6.7.7.7.8.8 Sones 8.4 8.5 8.6 8.5 8.6 8.6 8.6 8.6 8.7 8.7 85 VG-1/6 or 1/4 E-1/4 15 G-1/2 1 D-1/12 155 1725 CFM 58 292 272 26 142 B.1.2.2.2.2 Sones.8.7.6.8 4. CFM 44 91 78 2 299 261 186 B.2...... Sones 5.4 5.4 5.4 5.4 5.4 5.4 5.5 CFM 528 485 474 44 414 87 44 28 294 254 B.4.5.5.5.5.5.6.6.6.6 Sones 7. 7. 7. 7. 7. 7.2 7. 7. 7.4 7.5 CFM 588 55 54 51 488 465 429 416 91 62 B.6.6.6.7.7.7.8.8.8.8 Sones 8.7 8.7 8.6 8.6 8.6 8.6 8.7 8.7 8.7 8.8 Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are 17

SQ 9-95 - Direct Drive 11 7 8 (2) 1 (25) 15 (81) 16 (46) 15 (81) Damper size = 12 x 12 (5 x 5) Unit weight** = 41 (19) Outlet velocity = 1.21 x cfm Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Static Pressure (Pa) 22 2 18 16 14 12 1 8 6 4 2 Static Pressure (in. wg).9.8.7.6.5.4..2.1 9-D 9-G 95-E 9-E 9-VG 95-D 95-G 95-VG. 2 4 6 8 1 Volume (cfm) 2 4 6 8 1 12 14 16 18 Volume (m /hr) (Direct) (Vari Green) Density.75 lb/ft Density 1.2 kg/m Motor Direct..125.2.25..75.4.5.6.625 9 VG-1/6 or 1/4 VG-1/6 or 1/4 95 E-1/5 15 G-1/25 1 D-1/1 155 1725 E-1/ 15 G-1/15 1 D-1/8 155 1725 CFM 5 7 271 188 B.2.2.2.2 Sones 4..9 4. 4.1 CFM 619 519 449 98 4 245 28 B..4.4.4.4.4.4 Sones 5.4 5.4 5.4 5.5 5.5 5.6 5.6 CFM 78 655 6 565 522 457 45 4 B.5.6.6.6.7.7.7.7 Sones 7.6 7.5 7.5 7.4 7.4 7.4 7.4 7.4 CFM 821 748 71 669 65 579 559 481 92 66 B.7.8.8.9.9.9.9.9.9.9 Sones 8.8 8.8 8.8 8.7 8.7 8.8 8.8 8.8 8.8 8.9 CFM 62 475 65 275 B.... Sones 4.9 4.5 4.4 4.5 CFM 771 66 58 52 461 52 11 B.5.6.6.6.6.6.6 Sones 7.6 6.7 6.5 6.4 6.4 6.4 6.4 CFM 92 8 766 72 678 64 579 462 25 276 B.9.9.1.1.1.1.1.1.9.9 Sones 9.6 9. 8.9 8.7 8.4 8.1 8. 7.6 7.2 7.1 CFM 124 948 89 85 89 751 729 641 55 57 B.12.1.1.1.1.14.14.14.14.14 Sones 11. 11. 1.8 1.6 1.4 1.1 9.9 9.8 9. 9.2 Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are 18

SQ 1 - Direct Drive 1 7 8 (52) 1 (25) 17 (42) 21 (5) 17 (42) Damper size = 14 x 14 (56 x 56) Unit weight** = 56 (25) Outlet velocity =.748 x cfm Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Static Pressure (Pa) 25 2 15 1 5 Static Pressure (in. wg) 1.2 1..8.6.4.2 86 114. 2 4 6 8 1 12 14 16 Volume (cfm) 5 1 15 2 25 Volume (m /hr) 1725 (Direct) (Vari Green) Density.75 lb/ft Density 1.2 kg/m Motor Direct..1.125.25..75.5.625.75 1. 1 VG-1/4 C-1/8 86 B-1/6 114 A-1/4 1725 CFM 725 68 611 B... Sones 4.7.8.7 CFM 961 898 881 786 79 657 B.6.7.7.7.7.7 Sones 7.4 6.6 6.5 6.1 5.9 5.6 CFM 1455 141 14 15 127 1292 1227 1156 178 81 B.22.2.2.2.24.24.24.25.25.22 Sones 1.2 12.6 12.5 11.9 11.7 11.5 11.1 1.7 1.4 9.6 Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are 19

SQ 12 - Direct Drive 15 7 8 (4) 1 (25) 19 (48) 21 (5) 19 (48) Damper size = 16 x 16 (46 x 46) Unit weight** = 67 () Outlet velocity =.571 x cfm Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Static Pressure (Pa) 4 5 25 2 15 1 5 Static Pressure (in. wg) 1.8 1.6 1.4 1.2 1..8.6.4.2 86 114. 5 1 15 2 Volume (cfm) 5 1 15 2 25 Volume (m /hr) 1725 (Direct) (Vari Green) Density.75 lb/ft Density 1.2 kg/m Motor Direct..125.25.75.5.625.75 1. 1.25 1.75 12 CFM 971 84 74 VG-1/2 C-1/8 86 B.5.6.6 Sones 4.4 4.1. CFM 1287 119 195 992 87 69 B-1/6 114 B.12.12.1.14.14.1 Sones 7.4 7.2 7. 6. 5.9 5.8 CFM 1948 1884 1819 1754 1692 1629 156 1417 124 1128 A-1/2 1725 B.41.42.42.44.45.46.46.48.48.47 Sones 14.7 14.1 1.8 1.6 1.5 1.4 1.2 12.6 11.9 11.7 Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are 2

SQ 1 - Direct Drive 17 7 8 (454) 1 (25) 21 (5) 21 (5) 21 (5) Damper size = 18 x 18 (457 x 457) Unit weight** = 77 (5) Outlet velocity =.451 x cfm Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Static Pressure (Pa) 4 5 25 2 15 1 5 Static Pressure (in. wg) 1.8 1.6 1.4 1.2 1..8.6.4.2 86 114. 5 1 15 2 25 Volume (cfm) 5 1 15 2 25 5 4 Volume (m /hr) 1725 (Direct) (Vari Green) Density.75 lb/ft Density 1.2 kg/m Motor Direct..125.25.75.5.625.75 1. 1.25 1.75 1 CFM 1181 149 891 VG-/4 C-1/8 86 B.7.8.8 Sones 6.2 5.2 4.5 CFM 1565 1472 167 1249 115 865 B-1/4 114 B.16.17.18.18.18.17 Sones 9.4 8. 7.4 6.8 6.5 6.4 CFM 268 28 2247 2175 215 29 1961 1791 1559 149 A-/4 1725 B.54.56.57.59.6.62.62.6.61.59 Sones 17.4 17.6 17.1 17.1 16.6 16.4 15.9 15.7 15.6 15.6 Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are 21

SQ 14 - Direct Drive 19 7 8 (55) 1 (25) 2 (584) 22 (559) 2 (584) Damper size = 2 x 2 (58 x 58) Unit weight** = 14 (47) Outlet velocity =.64 x cfm Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Static Pressure (Pa) 5 4 2 1 Static Pressure (in. wg) 2.1 1.8 1.5 1.2.9.6. 86 114. 5 1 15 2 25 5 Volume (cfm) 1725 (Direct) (Vari Green) Density.75 lb/ft Density 1.2 kg/m 1 2 4 5 Volume (m /hr) Motor Direct..25.75.5.625.75 1. 1.75 1.5 1.75 14 VG-/4 C-1/8 86 B-1/ 114 155 VG-1 A-1 1725 CFM 167 117 1 B.12.1.1 Sones 7. 6.2 5.9 CFM 217 1942 1818 1667 1447 1122 B.27.29....27 Sones 1.8 1.1 1. 9.8 9.6 9.4 CFM 295 279 27 2614 2524 2429 2188 155 B.67.71.72.74.75.75.75.69 Sones 16.7 16.2 15.8 15.6 15.5 15. 14.8 1.7 CFM 284 14 65 2985 296 2826 2646 2268 285 1625 B.9.97.98 1. 1.1 1. 1. 1. 1.1.9 Sones 2 19. 19. 18.7 18.6 18.4 18.2 17.2 16.7 15.9 Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are 22

SQ 16 - Direct Drive 22 7 8 (581) 1 (25) 26 (66) 26 (66) 26 (66) Damper size = 2 x 2 (584 x 584) Unit weight** = 16 (7) Outlet velocity =.275 x cfm Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Static Pressure (Pa) 6 5 4 2 1 Static Pressure (in. wg) 2.8 2.4 2. 1.6 1.2.8.4 86 114. 1 2 4 5 6 Volume (cfm) 2 4 6 8 1 1725 Volume (m /hr X 1) (Direct) (Vari Green) Density.75 lb/ft Density 1.2 kg/m Motor Direct..25.5.75 1. 1.25 1.5 1.75 1.875 2. 16 VG-/4 CFM 256 2148 165 C-1/4 86 B.2.2.24 Sones 8.8 7.2 6.5 CFM 22 62 277 288 188 B-1/2 114 B.47.51.54.56.51 Sones 14. 12.8 11.9 11.4 1.8 CFM 788 562 2 2685 222 VG-1 1 B.7.74.78.81.84.79 Sones 16.8 15.8 14.8 14.5 14.1 1.7 CFM 527 4857 4684 454 412 494 845 575 414 26 VG-2 A-2 1725 B 1.64 1.69 1.74 1.8 1.85 1.89 1.9 1.95 1.94 1.91 Sones 26 25 24 24 24 24 24 24 24 24 Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are 2

BSQ 7 - Belt Drive 11 7 8 (2) 1 (25) 15 (81) *15 1 2 (94) *14 (56) Damper size = 12 x 12 (5 x 5) Unit weight** = 76 (4) 21 (5) *12 1 2 (18) 15 (81) Static Pressure Pa 6 4 2 Static Pressure in. wg 2.5 2. 1.5 1..5 1/ hp 1/4 hp 1/2 hp 11. 1 2 4 5 6 cfm 2 4 6 8 1 m /hr Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. 79 147 181 215 2486 Density.75 lb/ft 24 Model Number 7 Motor 7-4 1/4 7-1/ 7-5 1/2 15 11 1445 1577 179 184 1972 272 2172 229 2486.125.25.5.625.75 1. 1.25 1.5 1.75 2. CFM 184 129 B.9.7 Sones 8. 7.5 CFM 251 211 117 B.77.76.68 Sones 11. 1.4 9.2 CFM 284 249 169 122 B.1.12.97.9 Sones 12.8 12. 1.7 1. CFM 14 284 21 175 11 B.1.1.1.12.12 Sones 14.9 14.6 12.7 11.9 11.4 MAX Bhp AT A GIVEN = (rpm/84) MAXIMUM = 2486 TIP SPEED (ft/min) = rpm x 2.928 MAX NEMA MOTOR FRAME SIZE = 145T OUTLET VELOCITY (ft/min) = 1.212 x cfm CFM 45 18 254 22 184 97 B.17.17.17.16.16.14 Sones 16.1 15.9 14.5 1.9 1. 12.4 CFM 75 51 29 262 21 159 B.21.21.21.21.2.19 Sones 17. 17. 16.4 16. 15.4 14.5 CFM 45 84 1 2 27 212 142 B.26.26.26.25.25.24.22 Sones 19.2 19.1 18.6 18.2 17.9 17.7 16.5 CFM 428 48 6 2 5 249 184 1 B.....29.29.27.24 Sones 2 2 19.9 19.5 19.1 18.5 18.2 16.8 CFM 45 41 87 61 5 282 224 161 B.4.5.5.4.4..2. Sones 21 21 21 21 2 19.7 19.2 18.8 CFM 486 467 428 46 81 2 28 225 166 B.4.4.4.4.42.42.41.9.6 Sones 2 2 2 2 2 22 21 2 21 CFM 521 54 468 447 426 8 4 287 22 176 B.52.52.52.52.52.51.5.49.47.44 Sones 25 25 25 25 25 24 2 22 22 2 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are

BSQ 8 - Belt Drive 11 7 8 (2) 1 (25) 15 (81) *15 1 2 (94) *14 (56) Damper size = 12 x 12 (5 x 5) Unit weight** = 79 (6) 21 (5) *12 1 2 (18) 15 (81) Static Pressure Pa 7 6 5 4 2 1 Static Pressure in. wg. 2.5 2. 1.5 1..5 1/4 hp 1/ hp 1/2 hp 79 116 15 /4 hp. 2 4 6 8 1 12 cfm 5 1 15 2 m /hr Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. 19 227 2645 Density.75 lb/ft Model Number 8 Motor 8-4 1/4 8-1/ 8-5 1/2 8-7 /4 15 127 152 1676 18 1926 218 2164 21 2478 2645.125.25.5.75 1. 1.25 1.5 1.75 2. 2.5 CFM 72 298 B.49.49 Sones 8. 7.6 CFM 445 86 26 B.7.75.65 Sones 9.7 9.1 8.2 CFM 585 542 442 1 B.15.15.15.14 Sones 1.9 1.5 11.8 1.8 CFM 652 615 5 426 254 B.19.2.2.2.17 Sones 15.9 15.6 14.1 12.9 11.5 CFM 72 687 61 524 424 B.25.26.26.26.25 Sones 17.2 16.9 16. 15. 14. MAX Bhp AT A GIVEN = (rpm/2866) MAXIMUM = 2645 TIP SPEED (ft/min) = rpm x 2.928 MAX NEMA MOTOR FRAME SIZE = 145T OUTLET VELOCITY (ft/min) = 1.212 x cfm CFM 76 728 66 579 486 46 B.29.....27 Sones 18.4 18. 17.8 17.1 16.9 1.9 CFM 799 769 74 6 545 452 269 B.4.4.5.5.4.4.28 Sones 19.6 19.5 19.2 18.4 18.1 16.7 1.5 CFM 861 8 774 78 6 55 442 B.41.42.4.4.4.42.4 Sones 21 21 21 2 19.6 19.2 17.6 CFM 924 897 842 784 716 64 56 445 B.5.51.52.52.52.52.51.48 Sones 2 2 22 2 21 21 2 19.9 CFM 995 969 919 865 87 74 671 597 486 B.62.6.6.64.65.65.64.6.59 Sones 25 25 24 25 24 2 22 22 2 CFM 165 141 995 945 894 85 77 75 65 95 B.75.76.77.78.79.79.78.77.77.65 Sones 28 28 27 27 27 26 25 24 24 5 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are 25

BSQ 9 - Belt Drive 11 7 8 (2) 1 (25) 15 (81) *15 1 2 (94) *14 (56) Damper size = 12 x 12 (5 x 5) Unit weight** = 84 (8) 21 (5) *12 1 2 (18) 15 (81) Static Pressure Pa 7 6 5 4 2 1 Static Pressure in. wg. 2.5 2. 1.5 1..5 1/4 hp 1/2 hp 1/ hp /4 hp. 2 4 6 8 1 12 14 16 18 cfm 5 1 15 2 25 m /hr Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. 79 117 155 1 hp 19 21 2691 Density.75 lb/ft 26 Model Motor Number 9 9-4 1/4 9-1/ 15 1211 15 1694 178 1866 9-5 1/2 216 9-7 /4 9-1 1 2291 2445 2568 2691.125.25.5.75 1. 1.5 1.75 2. 2.25 2.5 CFM 547 44 B.61.61 Sones 8. 7.6 CFM 655 574 B.92.95.84 Sones 9.8 9.1 8. CFM 864 86 667 477 B.18.19.19.18 Sones 14.2 1.8 12.1 11. CFM 965 914 798 654 47 B.25.25.26.25.22 Sones 16. 15.8 14.4 1.1 12. CFM 119 971 86 74 562 B.29.29...28 Sones 16.7 16.5 15.6 14.4 1.7 CFM 172 128 926 88 657 B...5.5. Sones 17.5 17. 16.9 15.9 15.4 MAX Bhp AT A GIVEN = (rpm/2649) MAXIMUM = 2691 TIP SPEED (ft/min) = rpm x 2.928 MAX NEMA MOTOR FRAME SIZE = 145T OUTLET VELOCITY (ft/min) = 1.212 x cfm CFM 129 122 1118 124 917 68 B.49.5.51.52.52.47 Sones 21 21 21 19.9 19.2 18.4 CFM 14 1 122 118 145 811 668 B.61.61.62.64.65.61.58 Sones 2 2 22 22 21 2 2 CFM 1429 196 126 1249 1167 976 844 77 B.7.74.75.77.79.77.7.7 Sones 25 25 24 25 2 22 22 2 CFM 154 147 147 16 1258 182 977 851 74 B.85.86.87.89.9.9.88.84.8 Sones 26 26 26 26 26 24 22 24 25 CFM 1579 1549 1488 142 147 1186 197 987 866 71 B.98.98 1. 1.2 1. 1.5 1. 1..96.91 Sones 28 28 27 28 28 26 25 24 26 29 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are

BSQ 1 - Belt Drive 1 7 8 (52) 1 (25) 17 (42) *15 1 2 (94) *14 (56) Damper size = 14 x 14 (57 x 57) Unit weight** = 91 (41) 21 (5) *12 1 2 (18) 17 (42) Static Pressure Pa 7 6 5 4 2 1 Static Pressure in. wg. 2.5 2. 1.5 1..5 1/4 hp 1/2 hp 1/ hp /4 hp. 5 1 15 2 25 cfm 1 2 4 m /hr Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. 79 1 hp 1145 15 1855 221 2556 Density.75 lb/ft Model Motor Number 1 1-4 1/4 15 1 1469 169 1-1/ 1772 1-5 1/2 1-7 /4 1-1 1 191 229 2176 22 244 2556.125.25.5.625.75 1. 1.25 1.5 1.75 2. CFM 774 671 B.72.7 Sones 7.9 7.6 CFM 124 95 77 B.14.15.15 Sones 11. 1.6 9.4 CFM 1145 18 91 87 B.19.2.2.2 Sones 1.2 12.6 11. 1.5 CFM 1265 127 188 1 917 B.25.25.26.26.26 Sones 15.4 15. 1.4 12.4 11.8 MAX Bhp AT A GIVEN = (rpm/2517) MAXIMUM = 2556 TIP SPEED (ft/min) = rpm x 2.928 MAX NEMA MOTOR FRAME SIZE = 145T OUTLET VELOCITY (ft/min) =.7617 x cfm CFM 145 152 1247 1187 111 99 B..4.5.5.5.5 Sones 16.6 16.4 15.5 14.8 14. 1.1 CFM 1515 1465 166 12 1255 1115 B.4.41.4.4.4.4 Sones 18. 17.8 17.4 17.1 16.6 16.2 CFM 162 1577 1484 149 196 1262 1119 B.49.5.52.52.52.52.52 Sones 19.8 19.6 19.4 19. 18.6 18.2 17.2 CFM 1747 174 1617 1574 15 1428 15 116 B.6.61.6.64.65.65.65.65 Sones 21 21 21 21 2 19.8 19. 18.5 CFM 1871 18 1749 178 1668 1591 1472 158 1197 B.7.74.76.78.79.79.79.79.78 Sones 2 2 2 2 2 22 21 2 21 CFM 1969 19 185 1815 1776 17 165 1494 177 1184 B.84.86.88.89.9.91.91.91.91.88 Sones 25 25 24 24 25 2 2 22 22 2 CFM 266 229 1956 1919 1882 181 174 1626 1522 142 B.97.98 1.1 1.2 1. 1.5 1.5 1.5 1.5 1.5 Sones 26 26 25 26 26 25 25 24 22 24 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are 27

BSQ 12 - Belt Drive 15 7 8 (4) 1 (25) 19 (48) *17 7 8 (454) *16 (46) Damper size = 16 x 16 (46 x 46) Unit weight** = 97 (44) 21 (5) *12 1 2 (18) 19 (48) Static Pressure Pa 9 8 7 6 5 4 2 1 Static Pressure in. wg 4..5. 2.5 2. 1.5 1..5 1/ hp 1/4 hp 1 hp /4 hp 1/2 hp 1 1/2 hp. 5 1 15 2 25 cfm 5 1 15 2 25 5 4 45 5 m /hr Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. 79 11 147 181 215 249 Density.75 lb/ft 28 Model Number 12 Motor 12-4 1/4 12-1/ 12-5 1/2 1 167 147 156 1615 1724 12-7 /4 1974 12-1 1 12-15 1 1 2 27 2172 229 249.125.75.75 1. 1.25 1.5 2. 2.25 2.5 2.75 CFM 126 78 B.96.12 Sones 7.7 7.5 CFM 1471 111 12 B.24.25.26 Sones 1.9 1.5 1. CFM 1555 14 1145 B.28.29. Sones 11.7 11. 1.4 CFM 166 1492 1252 127 B.2..5.4 Sones 12.5 12.1 11.1 1.2 CFM 1764 161 1418 1245 B.9.41.4.4 Sones 1.8 1.6 12.4 11.8 CFM 1892 1767 1571 142 1241 B.47.49.52.52.52 Sones 15.2 15. 1.8 1.6 12.4 MAX Bhp AT A GIVEN = (rpm/2144) MAXIMUM = 249 TIP SPEED (ft/min) = rpm x.46 MAX NEMA MOTOR FRAME SIZE = 145T OUTLET VELOCITY (ft/min) =.585 x cfm CFM 218 275 198 1791 166 1518 B.71.7.76.78.78.78 Sones 19. 18.9 17.6 16.9 16.4 15.7 CFM 2298 2195 27 1928 181 168 129 B.82.84.88.89.91.91.86 Sones 21 21 19. 18.6 17.9 17.5 15.2 CFM 241 214 2164 262 195 186 155 B.94.97 1. 1.2 1.4 1.5 1. Sones 2 2 21 21 19.7 19. 17.5 CFM 2594 25 26 2268 2171 269 1841 1695 1477 B 1.16 1.19 1.22 1.25 1.27 1.28 1.29 1.28 1.2 Sones 26 26 24 2 2 22 21 19.9 18.8 CFM 2779 2694 256 2475 287 2294 29 1984 1852 1682 B 1.41 1.44 1.49 1.51 1.54 1.55 1.58 1.58 1.57 1.5 Sones 1 27 26 27 26 24 2 2 22 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are

BSQ 1 - Belt Drive 17 7 8 (454) 1 (25) 21 (5) *17 7 8 (454) *16 (46) Damper size = 18 x 18 (457 x 457) Unit weight** = 97 (44) 21 (5) *12 1 2 (18) 21 (5) Static Pressure Pa 7 6 5 4 2 1 Static Pressure in. wg. 2.5 2. 1.5 1..5 1/ hp 1/4 hp 1/2 hp 79 /4 hp 1 hp 115 142 1 1/2 hp 175. 5 1 15 2 25 5 cfm 1 2 4 5 m /hr Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. 25 255 Density.75 lb/ft Model Motor Number 1 1-4 1/4 9 11 129 1-1/ 1424 1-5 1/2 1527 16 1-7 /4 1866 1-1 1 1-15 1 1 2 196 25 222 255.125.25.5.75 1. 1.25 1.5 1.75 2. 2.5 CFM 184 911 B.86.87 Sones 7.7 7.7 CFM 1275 1151 79 B.1.1.12 Sones 8.8 8.7 8.5 CFM 1652 156 128 958 B.24.25.26.24 Sones 11.8 11.6 11.2 1.6 CFM 188 1754 1568 1299 B.2..5.4 Sones 1.6 1. 12.8 12.4 CFM 1984 192 174 1515 124 B.4.41.4.42.4 Sones 14.8 14.5 1.9 1. 12.6 MAX Bhp AT A GIVEN = (rpm/222) MAXIMUM = 255 TIP SPEED (ft/min) = rpm x.45 MAX NEMA MOTOR FRAME SIZE = 145T OUTLET VELOCITY (ft/min) =.4571 x cfm CFM 2126 25 198 1714 1468 1121 B.48.49.52.52.51.47 Sones 15.9 15.6 15. 14. 1.6 12.7 CFM 2448 289 2266 2128 1949 174 1462 B.72.7.76.78.78.76.7 Sones 19.9 19.5 18.8 18.2 17.2 15.9 14.7 CFM 2576 252 24 2279 212 194 1714 1419 B.8.84.87.9.91.89.87.8 Sones 21 21 19.9 19. 18.4 17. 16.7 16.2 CFM 272 2655 257 2426 2286 2117 1926 1686 119 B.95.96 1. 1. 1.5 1. 1.2.99.89 Sones 2 22 21 2 19.8 18.7 18. 17.9 18.5 CFM 295 2864 2751 265 25 29 2227 245 182 1.17 1.18 1.22 1.25 1.28 1.28 1.27 1.26 1.22 Sones 26 25 24 22 22 21 2 19.9 21 CFM 112 74 2971 2877 2777 2659 2514 259 2189 172 B 1.4 1.44 1.48 1.52 1.55 1.58 1.57 1.55 1.54 1.44 Sones 28 28 25 24 2 22 22 22 27 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are 29

BSQ 1 - Belt Drive 17 7 8 (454) 1 (25) 21 (5) *17 7 8 (454) *16 (46) Damper size = 18 x 18 (457 x 457) Unit weight** = 97 (44) 21 (5) *12 1 2 (18) 21 (5) Static Pressure Pa 11 1 9 8 7 6 5 4 2 1 Static Pressure in. wg 4.5 4..5. 2.5 2. 1.5 1..5 /4 hp 1/2 hp 1/ hp 1 1/2 hp. 5 1 15 2 25 cfm 5 1 15 2 25 5 4 m /hr Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. 1/4 hp 79 1 hp 119 159 199 29 277 Density.75 lb/ft Model Motor Number 1 1-4 1/4 1 152 1-1/ 1674 1-5 1/2 1-7 /4 1-1 1-15 1 1 1 2 1795 1916 255 2194 24 2414 2589 277.5.75 1. 1.25 1.5 1.75 2. 2.5..5 CFM 784 549 B.16.15 Sones 11.2 1.5 CFM 114 884 67 B.25.26.25 Sones 11.4 11.2 1.8 CFM 1161 148 9 7 B..4.5. Sones 12.4 12.5 12. 11.5 CFM 127 1176 16 9 691 B.4.41.42.42.4 Sones 1. 1.4 1.1 12.6 11.7 MAX Bhp AT A GIVEN = (rpm/277) MAXIMUM = 277 TIP SPEED (ft/min) = rpm x.45 MAX NEMA MOTOR FRAME SIZE = 145T OUTLET VELOCITY (ft/min) =.4571 x cfm CFM 18 1294 1192 191 925 68 B.48.5.5.52.51.48 Sones 14.6 14. 14.2 1.9 1. 11.9 CFM 151 1426 19 129 1146 971 756 B.59.6.62.62.65.62.59 Sones 16.9 15.9 15.4 15. 14.9 1.8 12.6 CFM 1621 1555 1477 188 1297 12 1 B.71.7.75.76.77.78.76 Sones 19.2 18.4 17.1 17. 17.2 16.5 15.1 CFM 1715 165 1582 154 1414 11 1229 865 B.81.84.86.87.87.9.9.84 Sones 21 2 19. 18.2 18.6 18.4 17.6 14.5 CFM 188 1749 1685 1614 152 1448 169 18 B.9.95.98 1. 1.1 1.1 1.4 1. Sones 22 22 21 19. 19.5 19.7 19.2 16.8 CFM 1956 191 1846 1781 1714 165 1557 192 176 B 1.14 1.17 1.19 1.22 1.24 1.24 1.25 1.28 1.21 Sones 24 25 24 22 21 22 22 2 17.7 CFM 218 256 25 195 1888 1825 175 168 1421 111 B 1.9 1.42 1.44 1.47 1.5 1.52 1.52 1.56 1.54 1.48 Sones 27 28 27 26 25 24 24 2 22 19.2 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are

BSQ 14 - Belt Drive 19 7 8 (55) 1 (25) 2 (584) *17 7 8 (454) *16 (46) Damper size = 2 x 2 (58 x 58) Unit weight** = 111 (5) 22 (559) *12 1 2 (18) 2 (584) Static Pressure Pa 8 7 6 5 4 2 1 Static Pressure in. wg.5. 2.5 2. 1.5 1..5 1/2 hp 1/ hp 1/4 hp 1 hp /4 hp 1 1/2 hp 79 165 2 hp 14 1615. 5 1 15 2 25 5 4 45 cfm 1 2 4 5 6 7 m /hr Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. 189 215 Density.75 lb/ft Model Motor Number 14 14-4 1/4 8 176 14-1/ 1185 14-5 1/2 1271 156 14-7 /4 155 14-1 1 161 179 14-15 1 1 2 1956 14-2 2 255 215.125.25.5.75 1. 1.5 1.75 2. 2.5 2.75 CFM 162 1185 B.1.11 Sones 6. 6.7 CFM 1927 181 158 B.24.25.26 Sones 1.7 1.7 1.2 CFM 2142 29 187 146 B.2..5.4 Sones 12.1 11.9 12. 1.6 CFM 211 2217 26 1741 1199 B.9.41.4.4.9 Sones 1. 1. 1.1 1. 12.7 CFM 2476 292 2197 1979 166 B.48.49.51.52.51 Sones 14.2 1.9 1.8 1.8 1.8 MAX Bhp AT A GIVEN = (rpm/1682) MAXIMUM = 215 TIP SPEED (ft/min) = rpm x.812 MAX NEMA MOTOR FRAME SIZE = 145T OUTLET VELOCITY (ft/min) =.692 x cfm CFM 2858 2787 2626 2449 225 1447 B.71.7.75.78.79.7 Sones 16.2 16. 16. 15.6 15. 1.9 CFM 8 2941 279 2625 2446 1865 B.82.84.86.89.91.87 Sones 17.1 16.9 16.9 16.6 16.1 14.8 CFM 159 94 295 2798 265 2177 1752 B.95.96.99 1.2 1.5 1..97 Sones 18.2 18. 17.9 17.7 17.2 16.1 15.1 CFM 6 576 461 19 2894 275 2457 B 1.41 1.4 1.47 1.49 1.5 1.57 1.57 1.55 Sones 24 2 24 24 2 22 21 2 CFM 822 769 662 57 41 16 2982 2777 2168 B 1.6 1.66 1.7 1.7 1.75 1.82 1.82 1.81 1.7 Sones 27 26 28 27 26 25 24 2 21 CFM 49 958 856 741 622 65 225 78 2627 226 B 1.88 1.9 1.95 1.98 2. 2.8 2.1 2.1 2.5 1.95 Sones 1 1 28 28 27 25 2 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are 1

BSQ 14 - Belt Drive 19 7 8 (55) 1 (25) 2 (584) *17 7 8 (454) *16 (46) Damper size = 2 x 2 (58 x 58) Unit weight** = 111 (5) 22 (559) *12 1 2 (18) 2 (584) Static Pressure Pa 12 1 8 6 4 2 Static Pressure in. wg 5 4 2 1 5 1 15 2 25 5 cfm 1 2 4 5 m /hr Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. 1 hp 1/2 hp 1/ hp /4 hp 1 1/2 hp 79 2 hp 116 15 19 227 2641 Density.75 lb/ft 2 Model Motor Number 14 14-1/ 14-5 1/2 14-7 /4 14-1 14-15 14-2 14 145 1559 1664 1785 195 1 296 1 1 2 2 2197 299 252 2641.5.75 1. 1.25 1.5 1.75 2. 2.5..5 CFM 1285 182 B.27.27 Sones 11.4 11.2 CFM 1449 1281 158 B.5.5.4 Sones 1. 12.8 12.4 CFM 161 1452 127 948 B.42.4.4.9 Sones 15.1 14.6 14.2 1.4 CFM 1742 167 1456 1264 8 B.51.52.52.52.4 Sones 16.5 15.9 15.5 15. 1.8 CFM 192 1782 1652 1495 17 B.6.64.65.65.64 Sones 17.9 17. 16.7 16.1 15.5 MAX Bhp AT A GIVEN = (rpm/264) MAXIMUM = 2641 TIP SPEED (ft/min) = rpm x.812 MAX NEMA MOTOR FRAME SIZE = 145T OUTLET VELOCITY (ft/min) =.692 x cfm CFM 257 1954 182 171 1548 16 B.76.77.79.79.79.77 Sones 19.7 19.1 18.4 17.7 17.1 16.7 CFM 2298 2211 218 1998 1878 1741 1581 B 1.1 1.2 1. 1.5 1.5 1.5 1.4 Sones 24 2 22 21 2 2 19.7 CFM 2425 244 225 2145 241 1918 178 1299 B 1.16 1.18 1.18 1.21 1.21 1.21 1.21 1.8 Sones 26 25 24 2 22 22 22 22 CFM 2676 26 2525 247 29 2244 214 1882 181 B 1.5 1.52 1.5 1.54 1.57 1.57 1.57 1.56 1.9 Sones 29 28 27 26 25 24 2 2 CFM 2825 2755 2684 266 2515 242 2 217 189 B 1.7 1.76 1.78 1.78 1.81 1.82 1.82 1.82 1.79 Sones 2 1 28 27 26 25 24 CFM 297 297 2841 2768 2688 2599 2512 219 288 1759 B 1.98 2.1 2.4 2.5 2.6 2.9 2.1 2.1 2.9 2. Sones 2 1 29 27 26 24 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are

BSQ 16 - Belt Drive 22 7 8 (581) 1 (25) 26 (66) *2 1 2 (521) *17 (42) Damper size = 2 x 2 (584 x 584) Unit weight** = 28 (94) 26 (66) *1 8 (4) 26 (66) Static Pressure Pa 9 8 7 6 5 4 2 1 Static Pressure in. wg 4..5. 2.5 2. 1.5 1..5. 1 2 4 5 6 cfm 1 2 4 5 6 7 8 9 1 m /hr X 1 Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. /4 hp 1/2 hp 1/ hp 1/4 hp 1 hp 1 1/2 hp 59 2 hp 87 115 hp 14 171 21 Density.75 lb/ft Model Motor Number 16 16-4 1/4 65 87 16-1/ 962 16-5 1/2 111 16-7 /4 1261 16-1 1 187 16-15 1 1 2 1488 1588 16-2 2 1748 16-1875 21.125.5.75 1. 1.5 1.75 2. 2.25 2.5. CFM 1671 B.1 Sones 6.6 CFM 27 1759 B.2.26 Sones 8.8 8.2 CFM 264 215 B.1.5 Sones 9.9 9. CFM 61 2665 21 B.46.51.52 Sones 12.4 11.4 11.2 CFM 58 212 2946 2611 B.68.74.78.78 Sones 15.5 14.6 14.4 1.2 CFM 911 628 42 146 211 B.9.97 1.1 1.4.96 Sones 18. 17.2 16.9 16.1 1.1 MAX Bhp AT A GIVEN = (rpm/166) MAXIMUM = 21 TIP SPEED (ft/min) = rpm x 4.84 MAX NEMA MOTOR FRAME SIZE = 184T OUTLET VELOCITY (ft/min) =.2782 x cfm CFM 429 949 745 519 2921 242 B 1.1 1.18 1.2 1.27 1.27 1.17 Sones 19.9 19. 18.9 18.4 15.9 14.5 CFM 45 4259 479 88 89 55 2566 B 1. 1.42 1.47 1.52 1.56 1.5 1.42 Sones 22 21 22 21 18.9 17.5 16.1 CFM 497 4751 46 4425 47 82 528 185 B 1.77 1.88 1.92 1.98 2.8 2.9 2.7 2.1 Sones 28 26 27 27 24 2 22 19.9 CFM 545 518 5 4847 451 412 491 844 5 B 2.18 2. 2.5 2.41 2.5 2.57 2.58 2.56 2.5 Sones 1 1 2 29 27 25 2 CFM 571 5519 59 526 4946 4774 4596 492 416 566 B 2.64 2.77 2.84 2.89..8.12.14.12 2.99 Sones 4 6 6 8 8 6 4 1 29 26 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are

BSQ 16 - Belt Drive 22 7 8 (581) 1 (25) 26 (66) *2 1 2 (521) *17 (42) Damper size = 2 x 2 (584 x 584) Unit weight** = 28 (94) 26 (66) *1 8 (4) 26 (66) Static Pressure Pa 12 1 8 6 4 2 Static Pressure in. wg 5 4 2 1 1/2 hp 1/ hp /4 hp 1 1/2 hp 1 2 4 5 cfm 2 4 6 8 m /hr Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. 1 hp 69 2 hp 115 14 hp 1665 199 221 Density.75 lb/ft 4 Model Motor Number 16 16-1/ 15 1116 16-5 1/2 1277 16-7 /4 1462 16-1 16-15 16-2 16-1 169 1 1 2 2 1726 1842 195 227 2174 221.5.75 1. 1.25 1.5 2. 2.5..5 4. CFM 1669 129 B.29.28 Sones 7.8 7.2 CFM 1844 15 B.5.5 Sones 8.6 8. CFM 227 22 171 15 B.5.52.52.49 Sones 1.8 1.1 9.6 8.9 CFM 2664 2497 2299 25 172 B.74.77.79.78.76 Sones 14.1 1.4 12.9 12.7 12.6 MAX Bhp AT A GIVEN = (rpm/1584) MAXIMUM = 221 TIP SPEED (ft/min) = rpm x 4.84 MAX NEMA MOTOR FRAME SIZE = 184T OUTLET VELOCITY (ft/min) =.2782 x cfm CFM 2986 2845 2688 2497 2269 161 B.97 1. 1. 1.5 1.4.97 Sones 17.8 17. 16.7 16. 16.4 16.9 CFM 29 116 2974 2814 26 2157 B 1.18 1.22 1.25 1.28 1.29 1.26 Sones 22 21 21 19.8 19.8 21 CFM 488 77 248 115 2954 257 21 B 1.42 1.47 1.51 1.54 1.56 1.56 1.49 Sones 25 24 24 2 22 2 25 CFM 686 58 464 8 2 2859 245 B 1.6 1.68 1.7 1.77 1.8 1.82 1.79 Sones 27 25 25 25 24 24 25 CFM 881 78 676 555 44 15 276 2248 B 1.87 1.92 1.97 2.1 2.5 2.9 2.7 1.99 Sones 28 28 25 27 26 26 27 28 CFM 4191 497 42 897 785 56 2 2866 257 B 2.29 2.4 2.4 2.45 2.49 2.56 2.58 2.55 2.44 Sones 2 1 28 28 29 29 29 1 CFM 4499 4411 422 424 4129 918 66 51 1 255 B 2.77 2.8 2.89 2.95..9.14.1.9 2.97 Sones 6 4 4 28 1 2 4 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are

BSQ 18 - Belt Drive 2 7 8 (66) 1 1 2 (8) 28 (711) *24 8 (619) *18 (457) Damper size = 24 x 24 (61 x 61) Unit weight** = 245 (111) 28 (711) *1 4 (49) 28 (711) Static Pressure Pa 7 6 5 4 2 1 Static Pressure in. wg. 2.5 2. 1.5 1..5 1/2 hp 1/ hp 1 hp /4 hp 1 1/2 hp. 1 2 4 5 6 7 cfm 2 4 6 8 1 m /hr X 1 Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. 59 2 hp 11 8 hp 122 14 1645 Density.75 lb/ft Model Motor Number 18 18-1/ 7 791 18-5 1/2 95 18-7 /4 17 18-1 1 1141 18-15 1 1 2 18-2 2 18-1224 16 172 147 1541 1645.125.25.5.75 1. 1.25 1.5 1.75 2. 2.5 CFM 2649 287 B.2.24 Sones 1. 9.6 CFM 51 2845 2217 B.2.4.5 Sones 1.6 1.9 9.6 CFM 546 66 2928 2175 B.48.49.52.49 Sones 12.2 12.1 11.6 1.8 CFM 419 955 616 179 242 B.71.7.77.79.7 Sones 14.5 14.2 1.5 1.4 12.8 MAX Bhp AT A GIVEN = (rpm/1125) MAXIMUM = 1645 TIP SPEED (ft/min) = rpm x 4.84 MAX NEMA MOTOR FRAME SIZE = 184T OUTLET VELOCITY (ft/min) =.255 x cfm CFM 4549 4412 4127 76 29 252 B.94.96 1.1 1.4 1.4.96 Sones 16.5 16.1 15.4 15. 14.9 1.8 CFM 4898 4774 457 4194 86 21 B 1.15 1.18 1.2 1.28 1.29 1.27 1.8 Sones 18.4 17.7 17.1 16.5 16.5 15.8 14.4 CFM 5242 5128 4878 461 4281 884 2 B 1.4 1.4 1.48 1.5 1.56 1.57 1.5 Sones 2 19.5 18.8 18. 17.8 17.5 16.8 CFM 5519 541 5174 497 46 48 854 218 B 1.62 1.65 1.71 1.75 1.81 1.82 1.81 1.7 Sones 22 21 2 19.8 19. 18.7 18. 17.5 CFM 579 5686 546 526 4964 4662 4298 814 16 B 1.86 1.89 1.95 2. 2.6 2.9 2.9 2.4 1.89 Sones 2 22 22 21 21 19.7 19.6 19.1 18.2 CFM 6224 6127 5922 571 5488 521 4927 4567 4116 B 2.29 2.2 2.8 2.45 2.5 2.56 2.58 2.57 2.52 Sones 26 25 25 24 24 22 22 21 21 CFM 6656 6566 677 6179 5981 5744 5485 5216 4866 898 B 2.78 2.81 2.88 2.95.1.7.12.14.1 2.94 Sones 29 28 28 27 27 26 24 24 24 2 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are 5

BSQ 18 - Belt Drive 2 7 8 (66) 1 1 2 (8) 28 (711) *24 8 (619) *18 (457) Damper size = 24 x 24 (61 x 61) Unit weight** = 245 (111) 28 (711) *1 4 (49) 28 (711) Static Pressure Pa 9 8 7 6 5 4 2 1 Static Pressure in. wg 4..5. 2.5 2. 1.5 1..5 1 hp /4 hp 1/2 hp 1 1/2 hp. 1 2 4 5 6 cfm 1 2 4 5 6 7 8 9 1 m /hr X 1 Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. 59 2 hp 855 112 hp 185 165 191 Density.75 lb/ft 6 Model Number 18 Motor 18-5 1/2 18-7 /4 18-1 18-15 18-2 18-1 18 1166 1249 1 12 1 1 2 2 1415 1498 1581 1664 1747 191.5.75 1. 1.25 1.5 1.75 2. 2.5..5 CFM 252 218 B.44.45 Sones 1.9 1. CFM 266 264 1984 B.55.57.56 Sones 12.1 11.2 1.5 CFM 297 2672 279 1951 B.67.7.71.69 Sones 1.4 12.6 11.7 1.9 CFM 169 2964 2724 246 1945 B.81.85.87.87.82 Sones 14.7 14.1 1.2 12.4 11.4 MAX Bhp AT A GIVEN = (rpm/16) MAXIMUM = 191 TIP SPEED (ft/min) = rpm x 4.84 MAX NEMA MOTOR FRAME SIZE = 184T OUTLET VELOCITY (ft/min) =.255 x cfm CFM 428 247 2 2782 2458 151 B.98 1.2 1.5 1.6 1.5.8 Sones 16. 15.7 14.8 14. 1.1 11. CFM 681 518 28 116 2857 257 B 1.15 1.2 1.24 1.26 1.27 1.26 Sones 18. 17.4 16.6 15.6 14.8 14. CFM 91 782 614 42 212 2944 2622 B 1.5 1.41 1.45 1.49 1.51 1.5 1.48 Sones 19.9 19.1 18.6 17.6 16.8 15.9 15. CFM 418 44 89 718 528 12 49 B 1.57 1.64 1.69 1.7 1.76 1.77 1.77 Sones 22 21 2 19.7 18.9 18.2 17. CFM 4425 4298 4158 4 8 648 429 2859 B 1.81 1.89 1.95 1.99 2. 2.6 2.7 2.1 Sones 24 2 2 22 21 21 19.7 17.9 CFM 4669 455 4421 4285 4125 956 78 8 21 B 2.8 2.16 2.2 2.29 2. 2.6 2.9 2.8 1.94 Sones 27 26 25 24 24 2 2 21 16.9 CFM 5155 55 498 4816 4691 4545 496 458 62 6 B 2.7 2.78 2.88 2.95..5.9.14.12 2.96 Sones 2 1 29 29 28 26 2 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are

BSQ 2 - Belt Drive 27 7 8 (78) 1 1 2 (8) 2 (81) *28 (711) *2 (58) Damper size = 28 x 28 (711 x 711) Unit weight** = 14 (142) 2 (81) *16 (46) 2 (81) Static Pressure Pa 7 6 5 4 2 1 Static Pressure in. wg. 2.5 2. 1 hp /4 hp 1/2 hp 1/ hp 1.5 1..5 1 1/2 hp. 1 2 4 5 6 7 8 cfm 2 4 6 8 1 12 m /hr X 1 Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. 9 2 hp 59 79 hp 99 119 175 Density.75 lb/ft Model Number 2 Motor 2-1/ 6 66 2-5 1/2 756 2-7 /4 811 865 2-1 1 952 2-15 1 1 2 19 2-2 2 2-1145 12 1287 175.125.25.5.75.875 1. 1.25 1.5 1.75 2. CFM 296 2616 B.25.26 Sones 11.1 1.6 CFM 15 18 242 B..4. Sones 11.7 11.2 1.5 CFM 867 624 6 B.49.5.52 Sones 12.7 12. 11.7 CFM 4179 959 442 256 B.6.62.64.62 Sones 1.4 12.8 12. 1. CFM 4484 4285 812 29 2516 B.7.75.77.79.72 Sones 14.1 1.7 1.1 1. 1.9 MAX Bhp AT A GIVEN = (rpm/97) MAXIMUM = 175 TIP SPEED (ft/min) = rpm x 5.595 MAX NEMA MOTOR FRAME SIZE = 184T OUTLET VELOCITY (ft/min) =.187 x cfm CFM 4972 4796 491 916 646 2 B.96.99 1.1 1.4 1.5 1. Sones 15.7 15.5 15.1 14.9 14.5 14.4 CFM 5741 5587 525 4874 4672 4452 878 B 1.4 1.47 1.51 1.5 1.55 1.56 1.56 Sones 19.1 18.9 18.7 18.5 18.6 18.7 17. CFM 646 5899 5588 524 547 4855 441 58 B 1.66 1.69 1.74 1.77 1.79 1.81 1.82 1.7 Sones 21 2 2 2 2 2 19.2 18.6 CFM 65 621 592 5597 5416 52 486 416 B 1.9 1.94 2. 2.2 2.4 2.6 2.9 2.8 Sones 22 22 21 21 21 21 21 19.8 CFM 68 6699 649 618 5988 5818 5475 588 4557 B 2.4 2.8 2.46 2.49 2.5 2.52 2.56 2.58 2.56 Sones 25 24 24 24 2 2 2 2 22 CFM 714 7192 6948 6677 657 696 676 575 579 4862 B 2.85 2.89 2.98.2..5.9.14.15.1 Sones 27 27 26 26 26 26 25 25 25 24 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are 7

BSQ 2 - Belt Drive 8 27 7 8 (78) 1 1 2 (8) 2 (81) *28 (711) *2 (58) Damper size = 28 x 28 (711 x 711) Unit weight** = 14 (142) Model Motor Number 2 2-5 1/2 2-7 /4 2-1 2-15 2-2 2-85 88 945 19 1 1111 1 1 2 2 1191 1271 15 199 1467 162 2 (81) *16 (46) 2 (81) Static Pressure Pa 8 7 6 5 4 2 1.5.75 1. 1.25 1.5 1.75 2. 2.25 2.5. CFM 258 27 B.47.47 Sones 12. 11.6 CFM 2724 2258 B.51.52 Sones 12.8 12. CFM 2 2656 194 B.6.65.61 Sones 14.2 14.1 12.4 CFM 27 2556 B.76.78.78 Sones 15.6 15.9 14.7 CFM 787 495 179 272 B 1. 1. 1.5 1.4 Sones 16.9 17.4 16.9 15. CFM 4129 87 594 26 276 B 1.22 1.26 1.28 1.29 1.27 Sones 17.9 18. 18.9 17.2 15.7 2 4 6 8 1 MAX Bhp AT A GIVEN = (rpm/19) MAXIMUM = 162 TIP SPEED (ft/min) = rpm x 5.595 MAX NEMA MOTOR FRAME SIZE = 184T OUTLET VELOCITY (ft/min) =.187 x cfm CFM 4466 425 979 716 79 288 B 1.47 1.51 1.55 1.57 1.57 1.52 Sones 18.8 18.9 21 19.8 17.5 16.2 CFM 47 452 4282 45 748 82 272 B 1.69 1.74 1.78 1.81 1.82 1.81 1.72 Sones 19.7 19.9 21 22 19.6 17.7 16.5 CFM 4998 48 4578 444 418 82 49 272 B 1.9 1.99 2. 2.7 2.9 2.9 2.8 1.95 Sones 21 21 21 24 22 19.5 18.1 17. CFM 5277 592 4888 4667 4442 419 898 47 2724 B 2.22 2.28 2. 2.7 2.4 2.42 2.42 2.9 2.22 Sones 2 22 22 24 25 22 19.6 18.7 17.6 CFM 582 5659 5489 5291 589 488 4669 441 489 2894 B 2.86 2.9..4.8.12.15.15.14 2.86 Sones 26 26 25 25 27 27 25 2 22 2 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are Static Pressure in. wg.5. 2.5 2. 1.5 1..5 1 hp /4 hp 1/2 hp 1 1/2 hp 2 hp hp. 1 2 4 5 6 7 cfm m /hr X 1 Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. 9 6 87 111 15 162 Density.75 lb/ft

BSQ 24 - Belt Drive 4 7 8 (886) 1 1 2 (8) 9 (991) *2 7 8 (85) *22 (559) Damper size = 5 x 5 (889 x 889) Unit weight** = 415 (188) 4 (864) *19 (48) 9 (991) Static Pressure Pa 7 6 5 4 2 1 Static Pressure in. wg. 2.5 2. 1.5 1..5 2 hp 1 1/2 hp 1 hp /4 hp 1/2 hp. 2 4 6 8 1 12 14 cfm X 1 5 1 15 2 m /hr X 1 Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. 9 hp 56 7 5 hp 9 17 1225 Density.75 lb/ft Model Motor Number 24 24-5 1/2 5 569 24-7 /4 651 24-1 1 684 717 24-15 1 1 2 826 24-2 2 9 24-24-5 5 969 14 198 1225.125.25.5.75 1. 1.25 1.5 1.75 2. 2.5 CFM 4518 41 B..5 Sones 1.7 1.2 CFM 5269 48 685 B.48.51.51 Sones 12. 11.8 1.8 CFM 612 5768 4946 B.7.74.78 Sones 14. 1.9 12.9 CFM 6475 615 568 427 B.81.85.9.89 Sones 15.2 14.9 1.8 12.6 CFM 6816 6498 5782 4884 B.9.97 1. 1. Sones 16.2 15.9 14.9 1.6 CFM 795 768 786 6425 564 B 1.41 1.45 1.54 1.59 1.58 Sones 19.5 19.5 18.7 17.4 16.2 MAX Bhp AT A GIVEN = (rpm/76) MAXIMUM = 1225 TIP SPEED (ft/min) = rpm x 6.414 MAX NEMA MOTOR FRAME SIZE = 215T OUTLET VELOCITY (ft/min) =.1192 x cfm CFM 872 8488 796 784 6756 5889 B 1.8 1.88 1.97 2.5 2.9 2.5 Sones 22 22 22 2 18.9 17.9 CFM 99 9174 8695 8176 7612 6962 675 B 2.25 2.1 2.41 2.5 2.56 2.57 2.52 Sones 25 24 24 2 21 2 19.4 CFM 148 9845 949 896 8421 7881 7219 6268 B 2.7 2.79 2.9.1.8.14.11. Sones 28 27 27 26 2 22 22 21 CFM 1694 15 115 966 9192 8695 816 751 6451 B.26.2.44.56.65.72.76.72.58 Sones 1 1 29 26 24 24 2 22 CFM 1197 1182 1146 117 1671 1245 984 945 8797 7124 B 4.5 4.58 4.72 4.84 4.97 5.7 5.16 5.22 5.2 4.95 Sones 41 4 8 7 4 1 28 28 28 26 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are 9

BSQ 24 - Belt Drive 4 7 8 (886) 1 1 2 (8) 9 (991) *2 7 8 (85) *22 (559) Damper size = 5 x 5 (889 x 889) Unit weight** = 415 (188) 4 (864) *19 (48) 9 (991) Static Pressure Pa 12 1 8 6 4 2 Static Pressure in. wg 5 4 2 1 2 hp 1 1/2 hp 7 1/2 hp 2 4 6 8 1 12 cfm X 1 5 1 15 2 m /hr X 1 Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. 1 hp hp 4 64 5 hp 88 112 16 165 Density.75 lb/ft 4 Model Number Motor 24 24-1 24-15 24-2 24-24- 5 24-75 1 78 82 1 1 2 99 2 986 1 118 5 7 1 2 1256 129 142 147 165.5.75 1. 1.25 1.5 2. 2.5..5 4. CFM 421 791 2789 B.88.9.8 Sones 14.4 14. 1.5 CFM 464 4149 492 B 1.1 1.4 1. Sones 15.2 14.8 14. CFM 5552 5159 4721 4161 B 1.48 1.54 1.57 1.55 Sones 18.1 17. 16.8 16. CFM 59 5541 515 469 41 B 1.69 1.76 1.81 1.82 1.76 Sones 19.2 18.2 17.9 17.5 17. CFM 6251 599 55 5128 469 B 1.9 2.1 2.7 2.9 2.7 Sones 2 19. 18.9 18.6 18.2 MAX Bhp AT A GIVEN = (rpm/87) MAXIMUM = 165 TIP SPEED (ft/min) = rpm x 6.414 MAX NEMA MOTOR FRAME SIZE = 215T OUTLET VELOCITY (ft/min) =.1192 x cfm CFM 76 746 6747 6419 67 529 B 2.85 2.94.2.9.1.1 Sones 25 24 22 22 22 21 CFM 784 7589 77 716 67 6 492 B.7.48.57.65.72.77.59 Sones 27 26 25 24 2 22 22 CFM 846 8125 7859 759 74 6686 5897 B.96 4.9 4.18 4.28 4.5 4.44 4.4 Sones 28 27 26 25 24 2 CFM 8848 8657 845 8152 7897 727 6721 579 B 4.61 4.76 4.86 4.96 5.6 5.2 5.24 5.9 Sones 1 29 27 25 25 24 CFM 91 912 898 8667 8427 791 74 6622 5565 B 5.28 5.44 5.57 5.67 5.77 5.94 6.2 5.97 5.7 Sones 6 4 2 2 1 27 26 25 24 CFM 122 166 9896 9675 9455 97 8512 7987 748 6474 B 6.8 6.98 7.16 7.27 7.8 7.6 7.78 7.84 7.8 7.57 Sones 4 42 9 8 8 4 29 28 27 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are

BSQ - Belt Drive 41 7 8 (164) 1 1 2 (8) 46 (1168) 8 (965) Damper size = 42 x 42 (167 x 167) Unit weight** = 57 (244) Housing thickness = 16 ga Model Motor Number -7 /4 41 449-1 1 494-15 1 1 2 566-2 2 62 - -5 5-75 7 1 2 *4 (864) 668 71 757 845 96 967 *22 (559) *18 (457) 46 (1168) Static Pressure Pa 7 6 5 4 2 1.125.25.5.75 1. 1.25 1.5 1.75 2. 2.25 CFM 6897 6141 B.57.6 Sones 1.4 1. CFM 769 7 4827 B.75.78.7 Sones 12.2 11.6 1.5 CFM 8598 7982 645 B.99 1.2 1.4 Sones 14.7 1.8 12. CFM 122 9469 86 6662 B 1.48 1.51 1.57 1.52 Sones 17.2 16.6 15.1 1.5 CFM 11129 166 9676 8418 B 1.96 2. 2.8 2.9 Sones 19. 19. 17.7 16. CFM 11997 11546 1647 9617 8157 B 2.4 2.46 2.54 2.59 2.52 Sones 21 21 19.8 18.5 17.2 Static Pressure in. wg. 2.5 2. 1.5 1..5 2 hp 1 1/2 hp 1 hp. 5 1 15 2 25 cfm X 1 1 2 4 m /hr X 1 MAX Bhp AT A GIVEN = (rpm/486) MAXIMUM = 967 TIP SPEED (ft/min) = rpm x 7.984 MAX NEMA MOTOR FRAME SIZE = 215T OUTLET VELOCITY (ft/min) =.826 x cfm CFM 12862 12446 11588 17 9547 78 B 2.91 2.97.6.1.1 2.95 Sones 2 2 22 21 19.8 18.5 CFM 174 121 12496 11714 1727 9442 B.47.55.64.7.76.68 Sones 25 25 24 2 22 21 CFM 158 1541 147 164 1286 11957 189 99 B 4.8 4.9 5.1 5.12 5.2 5.2 5.16 4.9 Sones 27 27 28 27 26 25 24 2 CFM 1658 16221 15548 1487 1427 1481 12576 11497 199 B 5.91 6. 6.14 6.25 6.7 6.44 6.44 6.4 6.1 Sones 1 29 29 27 26 26 CFM 1769 1796 16776 16124 15526 14888 14171 127 12242 1147 B 7.17 7.27 7.44 7.55 7.67 7.78 7.85 7.82 7.71 7.5 Sones 4 4 2 29 28 /4 hp hp 75 5 hp 495 615 7 1/2 hp Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. 75 855 967 Density.75 lb/ft Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are 41

BSQ - Belt Drive 41 7 8 (164) 1 1 2 (8) 46 (1168) *4 (864) *22 (559) 8 (965) Damper size = 42 x 42 (167 x 167) Unit weight** = 57 (244) Housing thickness = 16 ga Model Motor Number - 15-2 - - 5-75 1 1 2 2 5 7 1 2 62 694 725 777 829 94 987 19 191 1144 1196 *18 (457) 46 (1168) Static Pressure Pa 11 1 9 8 7 6 5 4 2 1.5.75 1. 1.25 1.5 1.75 2. 2.5..5 CFM 5642 482 B 1.6 1.1 Sones 14.4 14. CFM 661 61 5168 452 B 1.44 1.51 1.5 1.6 Sones 16.5 16.1 15.8 16. CFM 6998 646 5729 4747 B 1.6 1.71 1.75 1.71 Sones 17.5 17.2 16.8 16.6 CFM 7641 7151 6556 5799 474 B 1.98 2.7 2.1 2.15 2.7 Sones 19. 19.1 18.5 18.4 18.2 Static Pressure in. wg 4.5 4..5. 2.5 2. 1.5 1..5. 2 4 6 8 1 12 14 2 4 6 8 1 12 14 16 18 2 22 MAX Bhp AT A GIVEN = (rpm/62) MAXIMUM = 1196 TIP SPEED (ft/min) = rpm x 7.984 MAX NEMA MOTOR FRAME SIZE = 215T OUTLET VELOCITY (ft/min) =.826 x cfm CFM 8265 78 717 671 594 455 B 2.6 2.47 2.56 2.61 2.61 2.4 Sones 21 21 21 2 2 2 CFM 9492 9142 8746 8281 7752 71 69 B.29.44.56.65.72.74.71 Sones 26 26 26 25 25 25 24 CFM 115 9788 9417 912 8564 827 7411 52 B.85 4.2 4.14 4.25 4.4 4.4 4.41.99 Sones 27 27 27 26 26 25 25 25 CFM 172 141 167 9711 9292 8847 82 728 B 4.45 4.6 4.78 4.9 5. 5.9 5.14 5.9 Sones 28 27 27 27 26 26 26 25 CFM 11297 111 171 171 16 961 9149 855 6257 B 5.11 5. 5.48 5.61 5.7 5.8 5.91 5.95 5.57 Sones 29 28 28 28 27 27 26 26 26 CFM 119 11626 115 116 171 16 995 92 782 B 5.86 6.5 6.25 6.4 6.54 6.65 6.76 6.88 6.82 Sones 29 29 29 29 29 28 27 27 26 CFM 12489 12228 11966 11681 1172 1147 1677 985 884 7545 B 6.65 6.86 7.6 7.24 7.9 7.5 7.64 7.81 7.85 7.6 Sones 29 28 28 28 27 2 hp 1 1/2 hp hp 5 hp 7 1/2 hp cfm X 1 m /hr X 1 Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. 4 56 77 88 14 1196 Density.75 lb/ft 42 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are

BSQ 6 - Belt Drive 47 7 8 (1216) 1 1 2 (8) 52 (121) *4 (864) *22 (559) 42 (167) Damper size = 48 x 48 (1219 x 1219) Unit weight** = 686 (11) Housing thickness = 16 ga *18 (457) 52 (121) Static Pressure Pa 7 6 5 4 2 1 Static Pressure in. wg. 2.5 2. 1.5 1..5 1 1/2 hp 1 hp 7 1/2 hp 1 hp. 5 1 15 2 25 cfm X 1 1 2 4 m /hr X 1 Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. 2 hp hp 5 hp 4 5 6 7 Density.75 lb/ft 811 Model Motor Number 6 6-1 1 6-15 1 1 2 2 76 44 41 6-2 2 474 6-54 6-5 5 64 6-75 7 1 2 6-1 1 69 77 774 811.125.25.5.75 1. 1.25 1.5 1.75 2. 2.25 CFM 825 6979 B.6.64 Sones 1.8 1.5 CFM 19 98 B 1.1 1.4 Sones 12.6 12.5 CFM 1898 9941 7828 B 1.25 1.28 1.25 Sones 1.6 1.6 12.2 CFM 1172 1872 898 B 1.51 1.55 1.55 Sones 14.7 14.7 1.7 CFM 118 122 176 8489 B 1.99 2.5 2.9 1.96 Sones 16.1 16.6 15.7 14.1 CFM 1581 14544 1112 11627 955 B 2.96.5.12.12 2.9 Sones 19.1 19.6 19.4 18.1 16.6 MAX Bhp AT A GIVEN = (rpm/7) MAXIMUM = 811 TIP SPEED (ft/min) = rpm x 9.424 MAX NEMA MOTOR FRAME SIZE = 215T OUTLET VELOCITY (ft/min) =.62 x cfm CFM 1841 17587 16511 1527 1481 1256 B 4.87 4.98 5.1 5.19 5.19 5.5 Sones 28 27 27 26 25 2 CFM 1942 191 188 16881 15926 14555 112 B 6. 6.12 6.1 6.8 6.45 6.8 6.2 Sones 29 29 29 28 28 27 25 CFM 282 247 19615 1855 17515 16475 1515 174 B 7. 7.42 7.66 7.75 7.82 7.84 7.72 7.49 Sones 1 1 2 2 1 29 28 CFM 21885 2159 2755 19765 18744 1789 1669 15429 186 B 8.44 8.57 8.82 8.95 9. 9.11 9. 8.86 8.55 Sones 2 2 4 2 CFM 22967 2267 21888 2111 19986 19146 18195 16996 15786 14128 B 9.69 9.8 1.1 1.27 1.5 1.44 1.45 1.4 1.1 9.7 Sones 4 5 7 6 5 4 2 2 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are 4

BSQ 6 - Belt Drive 47 7 8 (1216) 1 1 2 (8) 52 (121) *4 (864) *22 (559) 42 (167) Damper size = 48 x 48 (1219 x 1219) Unit weight** = 686 (11) Housing thickness = 16 ga *18 (457) 52 (121) Static Pressure Pa 11 1 9 8 7 6 5 4 2 1 Static Pressure in. wg 4.5 4..5. 2.5 2. 1.5 1..5 2 hp 1 1/2 hp 1 hp 7 1/2 hp. 2 4 6 8 1 12 14 16 cfm X 1 2 4 6 8 1 12 14 16 18 2 22 24 26 m /hr X 1 Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. hp 5 hp 445 59 775 88 126 Density.75 lb/ft 44 Model Motor Number 6 6-15 6-2 6-6- 5 6-75 6-1 1 1 2 49 545 2 6 5 7 1 2 1 644 687 7 815 874 9 98 126.5.75 1. 1.25 1.5 2. 2.5..5 4. CFM 599 479 B 1.12 1.12 Sones 16.1 15.8 CFM 712 6115 4672 B 1.51 1.55 1.51 Sones 17.6 16.9 16.9 CFM 8 7272 641 4868 B 1.97 2.6 2.9 1.99 Sones 18.4 17.6 17. 17.4 CFM 8745 814 781 6424 46 B 2.4 2.52 2.55 2.57 2.7 Sones 19. 18. 17.7 17.7 18.1 CFM 946 8955 8277 7528 645 B 2.87.1.9.12.8 Sones 19.5 19. 18.4 18.2 18.2 MAX Bhp AT A GIVEN = (rpm/469) MAXIMUM = 126 TIP SPEED (ft/min) = rpm x 9.424 MAX NEMA MOTOR FRAME SIZE = 215T OUTLET VELOCITY (ft/min) =.62 x cfm CFM 1177 9716 9142 8465 7741 4517 B.41.56.68.71.77.28 Sones 2 19.7 19.2 18.6 18.6 2 CFM 11576 1115 174 1198 959 818 4978 B 4.6 4.8 4.99 5.1 5.16 5.2 4.55 Sones 21 21 21 2 2 19.9 22 CFM 1255 1211 11747 1119 181 96 7849 B 5.64 5.88 6.5 6.22 6.5 6.42 6.29 Sones 24 2 2 22 22 22 22 CFM 1487 118 1274 1282 1199 199 9748 7674 B 6.8 7.4 7.26 7.45 7.61 7.75 7.86 7.52 Sones 27 27 25 25 25 24 24 25 CFM 14241 188 152 1182 12822 11879 18 9417 6847 B 7.8 8.8 8. 8.5 8.72 8.96 9.5 8.99 8.27 Sones 28 27 27 27 26 27 28 CFM 14975 1461 14286 1957 161 1286 1188 1796 8982 5679 B 8.9 9.2 9.47 9.69 9.89 1.25 1.1 1.46 1.12 8.6 Sones 4 2 29 29 29 2 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are

BSQ 42 - Belt Drive 5 7 8 (168) 1 1 2 (8) 58 (147) *4 (864) *22 (559) 5 (127) Damper size = 54 x 54 (172 x 172) Unit weight** = 789 (58) Housing thickness = 14 ga *18 (457) 58 (147) Static Pressure Pa 6 4 2 Static Pressure in. wg 2.5 2. 1.5 1..5. 5 1 15 2 25 cfm X 1 1 2 4 5 m /hr X 1 Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). *Motor cover is optional. Size may be greater depending on motor. hp 2 hp 5 hp 7 1/2 hp 25 1 hp 465 95 55 65 Density.75 lb/ft 67 Model Motor Number 42 42-2 2 42-42-5 5 42-75 7 1 2 42-1 1 27 49 89 417 445 487 528 566 64 65 67.125.25.75.5.75 1. 1.25 1.5 1.75 2. CFM 991 8281 B.68.7 Sones 6.. CFM 151 12428 1121 9592 B 1.41 1.48 1.51 1.49 Sones 9.4 8.7 8.1 7.8 CFM 15275 144 14 1212 B 1.9 2.2 2.8 2.9 Sones 1.2 12. 11.5 1.8 CFM 165 156 14714 1745 1126 B 2.7 2.46 2.5 2.58 2.52 Sones 16.6 15.7 14.8 1.9 12.5 CFM 1774 1691 1668 15188 12941 B 2.86 2.96.5.11.12 Sones 2 19.5 18.6 17.7 15.9 MAX Bhp AT A GIVEN = (rpm/4) MAXIMUM = 67 TIP SPEED (ft/min) = rpm x 11.6 MAX NEMA MOTOR FRAME SIZE = 215T OUTLET VELOCITY (ft/min) =.496 x cfm CFM 195 1881 1854 17257 15475 111 B.71.84.95 4.2 4.11 4. Sones 22 21 21 19.8 18.2 16.9 CFM 21244 2625 1997 1921 17747 1585 1154 B 4.7 4.85 4.97 5.8 5.22 5.24 4.99 Sones 25 24 2 2 21 2 18.7 CFM 22854 221 21659 2117 19644 188 1614 126 B 5.76 5.94 6.7 6.19 6.6 6.46 6.9 5.95 Sones 28 27 26 25 24 24 22 21 CFM 24459 295 26 22762 2152 226 185 16581 B 6.98 7.17 7.2 7.45 7.66 7.8 7.84 7.71 Sones 1 29 28 27 26 25 CFM 25765 25281 2474 24171 22996 21762 241 18681 16692 B 8.9 8.29 8.46 8.6 8.85 9. 9.12 9.9 8.88 Sones 5 2 1 29 28 CFM 2727 26778 26291 25749 2466 2491 2222 279 19111 1687 B 9.47 9.69 9.88 1. 1. 1.52 1.71 1.7 1.61 1.24 Sones 9 7 6 6 4 4 4 2 1 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 1. Values shown are 45

Direct Drive Specifications Model SQ Duct mounted supply, exhaust or return fans shall be of the centrifugal, direct-driven, inline type. The fan housing shall be of a square design constructed of heavy-gauge galvanized steel or aluminum and shall include square duct mounting collars. construction shall include two removable access panels located perpendicular to the motor mounting panel. The access panels must be of sufficient size to permit easy access to all interior components. The fan wheel shall be centrifugal, backward-inclined, constructed of aluminum, and shall include a wheel cone carefully matched to the inlet cone for precise running tolerances. Wheels shall be statically and dynamically balanced. Motors shall be permanently lubricated and carefully matched to the fan loads. Motors shall be readily accessible for maintenance. A NEMA-1 disconnect switch shall be provided as standard, except with explosion resistant motors, where disconnects are optional. Factory wiring shall be provided from motor to the handy box. All fans shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. shall bear a permanently affixed manufacturer s nameplate containing the model number and individual serial number for future identification. shall be model SQ as manufactured by Greenheck Corporation of Schofield, Wisconsin, USA. LEED information Greenheck became one of the first manufacturers in the Air Movement and Control industry to join the LEED/green movement when they joined the United States Green Building Council (USGBC) in 25. Greenheck has been actively researching qualification requirements for our products to meet LEED credits and prerequisites. The Vari-Green motor significantly helps qualification efforts for the Energy and Atmosphere credits and prerequisites; specifically credit one, Optimize Energy Performance and prerequisite two, Minimum Energy Performance. Vari-Green Motor Motor to be an electronic commutation (EC) motor specifically designed for fan applications. AC induction type motors are not acceptable. Examples of unacceptable motors are: Shaded Pole, Permanent Split Capacitor (PSC), Split Phase, Capacitor Start and phase induction type motors. Motors shall be permanently lubricated with heavy-duty ball bearings to match the fan load and prewired to the specific voltage and phase. Internal motor circuitry shall convert AC power supplied to the fan to DC power to operate the motor. Motor shall be speed controllable down to 2% of full speed (8% turndown). Speed shall be controlled by either a potentiometer dial mounted on the motor or by a -1 VDC signal. Motor shall be a minimum of 85% efficient at all speeds. Vari-Green Controls Constant Pressure Greenheck s Constant Pressure system shall be a complete package designed to regulate fan speed based on demand while maintaining a constant static pressure. System shall include fan with Vari- Green Motor, Vari-Green Constant Pressure control, transformer, and pressure tap. Vari-Green Constant Pressure control shall have the transducer integrated with a touch button control panel. Control shall have a run mode and a program mode preventing unwanted changes when in run mode. Transformer shall be factory-supplied to provide power to the Vari-Green Constant Pressure controller. System shall include a self-sealing aluminum pressure tube with ¼-inch connection. shall be centrifugal direct drive type in upblast, downblast, or inline configuration with controllable EC Vari-Green motor. Remote Dial Remote dial shall be a Vari-Green control specifically designed to provide -1 VDC signal to Greenheck s Vari-Green Motor. 2-Speed 2-Speed control shall be a Vari-Green Control specifically designed to allow the Vari-Green Motor to operate at two distinct speeds. 2-Speed Control shall include two dials that may be set at any point between and 1 VDC and an integral transformer capable of reducing 115/2 volt AC power to 24 volt AC power. 46

Belt Drive Specifications Model BSQ Duct mounted supply, exhaust or return fans shall be of the centrifugal, belt-driven, inline type. The fan housing shall be of a square design constructed of heavy-gauge galvanized steel or aluminum and shall include square duct mounting collars. construction shall include two removable access panels located perpendicular to the motor mounting panel. The access panels must be of sufficient size to permit easy access to all interior components. The fan wheel shall be centrifugal backward-inclined, constructed of aluminum and shall include a wheel cone carefully matched to the inlet cone for precise running tolerances. Wheels shall be statically and dynamically balanced. Motors shall be heavy-duty ball bearing type carefully matched to the fan load and furnished at the specified voltage, phase, and enclosure. Motors and drives shall be mounted out of the airstream. Motors shall be readily accessible for maintenance. Precision ground and polished fan shafts shall be mounted in permanently sealed, lubricated pillow block ball bearings. Bearings shall be selected for a minimum L 1 life in excess of 1, hours (L 5 average life in excess of 5, hours) at maximum cataloged operating speed. Drives shall be sized for a minimum of 15 percent of driven horsepower. Pulleys shall be of the fully machined cast iron type, keyed and securely attached to the wheel and motor shafts. Motor pulleys shall be adjustable for final system balancing. A NEMA-1 disconnect switch shall be provided as standard, except with explosion resistant motors, where disconnects are optional. Factory wiring shall be provided from motor to the handy box. shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. shall bear a permanently affixed manufacturer s nameplate containing the model number and individual serial number for future identification. shall be model BSQ as manufactured by Greenheck Corporation of Schofield, Wisconsin, USA. 47

Quick Delivery and Quick Build Programs Greenheck Corporation offers an extensive selection of Quick Delivery (QD) and Quick Build (QB) offerings. The QD program is Greenheck s stock program and the QB program offers configurable fans in one, three, five, or ten days. Model SQ-75 through 12 and 14 BSQ-7 through 12, 14 through 18 and 24 SQ-6 through 7, 1 and 16 BSQ-1 and 2 High Pressure BSQ-1 through 24 BSQ- through 42 High Pressure BSQ- and 6 Hundreds of in stock ventilation products and accessories are available for shipment to your jobsite in less than 24 hours from our strategically located warehouses throughout the world. The Greenheck Stock and Quick Build catalog is a great resource for specific options and accessories available with QD and QB fans. Best Available Program In Stock 1 Day Days Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties. Prepared to Support Green Building Efforts P.O. Box 41 Schofield, WI 54476-41 Phone (715) 59-6171 greenheck.com.f&v.116 R9 5-21 IP Copyright 21 Greenheck Corp.