RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.

Similar documents
RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

13 SEER. Light Commercial 3 Phase Packaged Heat Pump. RHP13 Features and Benefits. Refrigerant System. Cabinet Construction. Blower.

RPGE13. Product Specifications. 13 SEER Gas / Electric Residential Packaged Unit. Refrigerant System. Heat Exchanger. Cabinet Construction.

13 SEER Light Commercial 3 Phase

PRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES

PRPAC14 PRODUCT SPECIFICATIONS 14 SEER ELECTRIC/ELECTRIC PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER INSTALLATION WARRANTY

PRPDF14 PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT REFRIGERANT SYSTEM HEAT EXCHANGER CABINET CONSTRUCTION ACCESSORIES WARRANTY BLOWER

PRAC14 PRODUCT SPECIFICATIONS

n Heavy-duty, high efficiency compressor n Copper tubing with enhanced fin coils n External service gauge ports CABINET

Enhanced Air Conditioning

MCE4 MCE4. Electric Heating / Electric Cooling Packaged Thru-the-Wall Units

MCE4 FEATURES REFRIGERANT SYSTEM CABINET BLOWER CONTROLS INSTALLATION WARRANTY. Electric Heating / Electric Cooling Packaged Units

REFRIGERANT SYSTEM R410A Refrigerant High efficiency compressor Copper tubing with enhanced fin coils

REFRIGERANT SYSTEM R410A Refrigerant High efficiency compressor Copper tubing with enhanced fin coils

MGE4 FEATURES REFRIGERANT SYSTEM HEAT EXCHANGER CABINET BLOWER

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

Q7RE Series Single Packaged Heat Pump, Single Phase

TECHNICAL SPECIFICATIONS

PHR5. Product Specifications

Q5RD Series Single Packaged Heat Pump, Single Phase

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

GQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

4SHP18LS PRODUCT SPECIFICATIONS

CONVERTIBLE SINGLE PACKAGE HEAT PUMP

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

4SHP18LS. Product Specifications. 18 SEER Split System Enhanced Heat Pump COMPONENTS COMPRESSOR CABINET DESIGN WARRANTY COIL

Q4SD Series TECHNICAL SPECIFICATIONS. Single Packaged Heat Pump, Single Phase FEATURES AND BENEFITS

Q7RE Series Single Packaged Heat Pump, Single Phase

P6SD Series Single Packaged Air Conditioning, 13 SEER - R-410A 3, 4, 5 Ton Units

GQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q4SE Series Single Packaged Heat Pump, Single Phase

GR4GD Series. Single Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS. GR4GD 13 SEER 2 Ton thru 5 Ton Units FEATURES AND BENEFITS

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units

Tons BTU/h S.E.E.R* E.E.R** HSPF

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A

BCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

14 SEER R -410A PACKAGE DUAL FUEL HEAT PUMP 2 to 5 TONS Two -Stage, Gas Heating / Electric Heating and Cooling Unit

TECHNICAL SPECIFICATIONS

P8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

GP5RD Series. Single Packaged Air Conditioner, Single Phase TECHNICAL SPECIFICATIONS

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

BCE5V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS ACCESSORIES WARRANTY

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

ZHA/ZHB SERIES WARNING

P4SD Series Single Packaged Air Conditioning, 13 SEER 3, 4 and 5 Ton Units

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

GQ4 Series TECHNICAL SPECIFICATIONS. Three Phase Single Packaged Heat Pump (12 SEER) GQ4SC-036C GQ4SC-048C GQ4SC-060C FEATURES AND BENEFITS

P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase

P5RF Series Single Packaged Air Conditioner Single Phase

TECHNICAL SPECIFICATIONS

GR4GC Series Single Packaged Gas/Electric Units

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/Electric Units 3-5 Ton Units

GR4GA Series Single Packaged Gas/Electric Units

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

TECHNICAL SPECIFICATIONS

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP

P7RE Series Single Packaged Air Conditioner

GP4SN Series TECHNICAL SPECIFICATIONS. Single Packaged Electric Cooling Units. P4SN 10.3 EER Commercial System 7½ and 10 Ton Units

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

DF6SF Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 4-Stage Heat/2-Stage Cool with Variable Speed Blower ihybrid Package Units with R-410A

P7RE Series Single Packaged Air Conditioner

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

GPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

GPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h

APD14. Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF

CPG Series. Submittal Data Form. 3- to 6-Ton Self-Contained. Packaged Gas/Electric. with R-410A

P7RF Series Two-Stage, Single Phase Packaged Air Conditioner

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

SUNLINE 2000 TM TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

R6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

PHF SERIES. THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

HCH6. Product Specifications

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

CPG COMMERCIAL 5-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

PHB SERIES 7-1/2 and 10 TON

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

Transcription:

RPHP13 Product Specifications Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced fin coils External service gauge ports 13 SEER Heat Pump Residential Packaged Unit Form No. RPHP13-100 (05/2013) Cabinet Construction Low profile, with compact footprint Insulation to minimize heat loss plus reduce sound Baked on pre-painted steel cabinet finish Easy service access Wire grill protection One piece no leak top design Blower Insulated compartment to reduce sound High efficiency multispeed motor for wide airflow range Controls Integrated control with L.E.D. diagostics Defrost control board with field selectable time intervals High and low refrigerant pressure switches for system protection Installation Full perimeter base rail system for easy installation Horizontal or down discharge, duct covers provided Utility connections on right side Filter channels for 1" filter field provided Warranty 10 year limited parts and compressor warranty. See limited warranty document for details.

Number Guide RP HP 13 A 36 P - 1 A Residential Packaged A - Service Level Heat Pump Revision Code SEER 13 Series Voltage P - 208-230v/60hz/1 Nominal Capacity 36-36,000 Btuh (24 through 60) Electrical and Physical Data Voltage/HZ/ Phase Voltage Range Min. Circuit Amp. Max. Over Current Device Compressor Load Locked Rotor Load Condenser Fan Motor HP Nom. RPM Indoor Blower Motor Load HP Refrig. Charge Shipping Weight (lbs.) RPHP13A24P 208-230/60/1 197-253 21.3 30 12.8 58.3 1.2 1/4 1075 4.1 1/2 80 338 RPHP13A30P 208-230/60/1 197-253 21.3 30 12.8 64 1.2 1/4 1075 4.1 1/2 115 365 RPHP13A36P 208-230/60/1 197-253 26.1 35 16.6 79 1.2 1/4 1075 4.1 1/2 118 365 RPHP13A42P 208-230/60/1 197-253 30.4 45 18.3 112 1.7 1/3 1075 5.8 3/4 142 462 RPHP13A48P 208-230/60/1 197-253 34.7 50 21.8 117 1.7 1/3 1075 5.8 3/4 154 470 RPHP13A60P 208-230/60/1 197-253 40.5 60 26.4 134 1.7 1/3 1075 5.8 3/4 150 470 Performance SEER EER Cooling AHRI Capacity 1 BTUH Sensible Capacity Btuh CFM 47 Heating 17 HSPF BTUH COP BTUH COP RPHP13A24P 13.0 11.0 23,000 17,000 850 21,600 3.5 7.7 13,000 2.2 RPHP13A30P 13.0 11.0 28,000 21,000 1000 27,000 3.5 7.7 16,000 2.3 RPHP13A36P 13.0 11.0 34,600 25,600 1200 33,600 3.5 7.7 20,200 2.3 RPHP13A42P 13.0 11.0 40,000 30,400 1450 39,000 3.4 7.7 22,400 2.2 RPHP13A48P 13.0 11.0 46,000 35,000 1600 44,000 3.3 7.7 26,800 2.1 RPHP13A60P 13.0 10.5 56,000 39,200 1800 54,000 3.3 7.7 34,000 2.3 - Page 2 -

Blower Performance RPHP13A24P RPHP13A30P RPHP13A36P RPHP13A42P RPHP13A48P RPHP13A60P Blower Tap Subtract.10 Duct Static for Downflow CFM CFM @ ext. Static Pressure in inches wc without filter, dry coil 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1 640 460 370 --- --- --- --- 2 830 800 760 710 640 600 570 3 950 910 880 840 800 750 700 4 900 870 830 800 730 690 640 5 1060 1030 980 960 930 910 860 1 650 550 490 430 --- --- --- 2 1030 1000 970 930 900 860 820 3 1150 1110 1080 1050 1010 980 960 4 1110 1070 1040 1000 970 950 920 5 1150 1110 1080 1050 1010 980 960 1 650 590 500 430 --- --- --- 2 1240 1200 1150 1100 1060 1020 980 3 1320 1260 1230 1200 1160 1120 1080 4 1240 1200 1150 1100 1060 1020 980 5 1320 1260 1230 1200 1160 1120 1080 1 780 690 610 540 --- --- --- 2 1450 1370 1280 1200 1120 1060 990 3 1650 1570 1510 1440 1360 1260 1160 4 1510 1430 1380 1290 1220 1150 1090 5 1650 1570 1510 1440 1360 1260 1160 1 860 760 690 640 --- --- --- 2 1650 1600 1550 1500 1440 1370 1290 3 1800 1750 1690 1630 1570 1470 1330 4 1650 1600 1550 1500 1440 1370 1290 5 1800 1750 1690 1630 1570 1470 1330 1 1000 900 800 750 --- --- --- 2 1820 1790 1730 1670 1630 1530 1380 3 1950 1910 1860 1800 1700 1560 1360 4 1820 1790 1730 1670 1630 1530 1380 5 1950 1910 1860 1800 1700 1560 1360 Heating Performance Extended Ratings Taps 4 & 5 are used with Electric Heat. Refer to Heater Label on unit for proper Heat Tap selection Outdoor Temp - DB/WB ºF 0/0 17/15 35/33 47/43 62/56 Btuh kw Btuh kw Btuh kw Btuh kw Btuh kw RPHP13A24P 10,100 1.71 13,000 1.73 15,400 1.71 21,600 1.80 26,200 1.87 RPHP13A30P 10,700 2.03 16,000 2.04 21,100 2.14 27,000 2.26 32,700 2.33 RPHP13A36P 15,900 2.53 20,200 2.58 24,900 2.66 33,600 2.82 40,200 2.93 RPHP13A42P 20,000 2.92 23,200 3.10 27,800 3.24 39,000 3.36 46,800 3.50 RPHP13A48P 23,900 3.57 26,800 3.74 29,300 3.73 44,000 3.91 52,900 4.08 RPHP13A60P 25,200 4.30 34,000 4.34 41,200 4.32 54,000 4.78 64,800 5.03 - Page 3 -

Cooling Performance Extended Ratings Indoor Temp DB/WB ºF Outdoor Temp - DBºF 65 82 95 105 115 Btuh S/T kw Btuh S/T kw Btuh S/T kw Btuh S/T kw Btuh S/T kw 85/72 28,100 0.59 1.60 26,500 0.62 1.89 25,300 0.65 2.10 23,700 0.68 2.33 21,800 0.71 2.31 RPHP13A24P 80/67 26,500 0.67 1.59 25,000 0.70 1.85 23,000 0.74 2.09 21,400 0.76 2.31 19,100 0.81 2.30 75/63 25,000 0.71 1.58 22,600 0.74 1.87 20,700 0.76 2.08 19,100 0.81 2.30 17,100 0.85 2.29 75/57 23,100 1.00 1.56 21,600 1.00 1.84 20,500 1.00 2.05 18,800 1.00 2.27 16,900 1.00 2.25 85/72 33,700 0.61 1.97 31,900 0.64 2.30 30,500 0.67 2.56 28,200 0.70 2.84 25,900 0.73 2.82 RPHP13A30P 80/67 32,100 0.68 1.96 29,900 0.72 2.27 28,000 0.75 2.55 25,700 0.79 2.81 22,500 0.84 2.79 75/63 30,200 0.72 1.95 27,400 0.76 2.28 25,200 0.79 2.53 22,600 0.84 2.79 19,900 0.88 2.77 75/57 27,900 1.00 1.92 26,200 1.00 2.25 24,900 1.00 2.50 22,500 1.00 2.76 20,000 1.00 2.73 85/72 41,800 0.61 2.39 39,400 0.63 2.82 37,500 0.65 3.15 35,700 0.68 3.50 33,100 0.70 3.49 RPHP13A36P 80/67 39,400 0.68 2.37 37,500 0.71 2.80 34,600 0.74 3.14 32,000 0.76 3.47 29,500 0.80 3.43 75/63 37,100 0.72 2.36 33,900 0.75 2.79 31,500 0.77 3.12 29,400 0.82 3.45 26,200 0.86 3.42 75/57 34,300 1.00 2.32 32,300 1.00 2.75 30,800 1.00 3.08 28,900 1.00 3.40 26,100 1.00 3.36 85/72 45,300 0.63 2.72 43,800 0.65 3.25 43,200 0.66 3.65 40,600 0.675 4.07 37,800 0.69 4.08 RPHP13A42P 80/67 43,800 0.68 2.71 41,900 0.72 3.18 40,000 0.74 3.63 38,000 0.77 4.00 34,000 0.79 4.05 75/63 42,200 0.72 2.70 39,600 0.75 3.22 36,900 0.77 3.61 34,200 0.81 3.99 30,200 0.85 3.98 75/57 37,900 1.00 2.69 36,000 1.00 3.19 35,600 1.00 3.57 33,000 1.00 3.97 30,000 1.00 3.97 85/72 54,400 0.65 3.10 52,100 0.66 3.72 50,200 0.67 4.19 47,200 0.69 4.66 43,500 0.71 4.71 RPHP13A48P 80/67 51,900 0.71 3.08 49,500 0.73 3.64 46,000 0.76 4.18 43,500 0.78 4.55 38,400 0.80 4.65 75/63 49,900 0.73 3.06 45,600 0.76 3.64 42,300 0.78 4.09 38,700 0.82 4.55 34,300 0.85 4.60 75/57 45,200 1.00 3.02 42,800 1.00 3.63 40,900 1.00 4.10 37,900 1.00 4.53 34,200 1.00 4.56 85/72 68,500 0.60 3.87 64,500 0.62 4.61 61,300 0.63 5.17 57,500 0.65 5.76 52,300 0.66 5.75 RPHP13A60P 80/67 64,800 0.66 3.83 60,800 0.68 4.49 56,500 0.70 5.09 53,000 0.72 5.62 45,300 0.77 5.61 75/63 60,900 0.69 3.81 54,500 0.72 4.50 49,600 0.75 5.03 45800 0.78 5.56 40,500 0.81 5.52 75/57 56,400 1.00 3.75 52,700 1.00 4.45 49,800 1.00 4.99 45,500 1.00 5.53 40,300 1.00 5.50 - Page 4 -

Heat Strip Electric Heat Strip Heater Electrical No. RPHP13A24P RPHP13A30P RPHP13A36P RPHP13A42P RPHP13A48P RPHP13A60P AHSA05A AHSA07A AHSA010A AHSA015A AHSA05A AHSA07A AHSA010A AHSA015A AHSA20A Unit Supply Single Phase Heater kw Minimum Circuit Ampacity 1 Maximum Fuse / HACR Brkr. 2 1 Minimum Circuit Ampacity 2 Maximum Fuse / HACR Brkr. 2 240 5.0 31.2 35 ---- --- 208 3.7 27.8 30 ---- --- 240 7.0 41.7 50 ---- --- 208 5..3 36.8 40 ---- --- 240 10.0 57.3 60 ---- --- 208 7.5 50.3 60 ---- --- 240 15.0 57.3 60 26 30 208 11.3 50.3 60 22.5 25 240 5.0 33.3 35 ---- --- 208 3.7 29.9 30 ---- --- 240 7.0 43.8 50 ---- --- 208 5..3 38.9 40 ---- --- 240 10.0 59.4 60 ---- --- 208 7.5 52.4 60 ---- --- 240 15.0 59.4 60 26 30 208 11.3 52.4 60 22.5 25 240 20.0 59.4 60 52.1 60 208 15.0 52.4 60 45.1 50 Field Provided 1" Filter Dimensions Small Base Large Base 2, 2.5, 3 Ton 3.5, 4, 5 Ton Sound Ratings No. Sound dba RPHP13A24P 77 RPHP13A30P 77 RPHP13A36P 77 RPHP13A42P 80 RPHP13A48P 80 RPHP13A60P 80 24" width 28" height 30" width 30" height Accessories Description Where Used Kit Number 5 kw Electric Heater All s AHSA05A-1 7 kw Electric Heater All s AHSA07A-1 10 kw Electric Heater All s AHSA10A-1 15 kw Electric Heater All s AHSA15A-1 20 kw Electric Heater 42, 48 & 60 AHSA20A-1 Roof Curb 24, 30 & 36 ACURB161-1 Roof Curb 42, 48 & 60 ACURB163-1 Manual Fresh Air Damper 24, 30, 36 ADMPR145-1 Manual Fresh Air Damper 42, 48, 60 ADMPR166-1 Motorized Fresh Air Damper 24, 30, 36 ADMPR146-1 Motorized Fresh Air Damper 42, 48, 60 ADMPR167-1 Downflow Economizer 24, 30, 36 AECON825-1 Downflow Economizer 42, 48, 60 AECON826-1 Horizontal Economizer 24, 30, 36 AECON827-1 Horizontal Economizer 42, 48, 60 AECON828-1 - Page 5 -

Dimensions (in.) No. A B C D E F RPHP13-24 RPHP13-30 RPHP13-36 RPHP13-42 RPHP13-48 RPHP13-60 32-1/2 46-1/2 46-1/2 45-5/8 45-5/8 17-1/2 34-1/2 55-1/2 50-1/2 54-5/8 49-5/8 21-1/2 No. G H J K L RPHP13-24 RPHP13-30 RPHP13-36 RPHP13-42 RPHP13-48 RPHP13-60 11-1/2 5-1/2 1-5/8 4 4 12 5-1/2 1-5/8 6-1/4 5-5/8 No. M N P Q R RPHP13-24 RPHP13-30 RPHP13-36 RPHP13-42 RPHP13-48 RPHP13-60 1-3/4 15-5/8 27-3/4 24-7/8 9-3/4 2-3/8 17-1/8 29-3/4 26-7/8 15-1/2 Elec. Heat Power Entry - Page 6 -

Accessories Dimensions inches (mm) ECONOMIZER DAMPERS - DOWNFLOW For 24, 30 and 36 s For 42, 48 and 60 s 12 18-3/8 24 (610) Fresh Air Head with Filter 28-1/4 (718) 16-13/16 13-7/16 Barometric Relief Damper (Underneath) Fresh Air Hood with Filter 19 (483) 19 (483) Barometric Relief Damper (Underneath) ECONOMIZER DAMPERS - HORIZONTAL No. A B in mm in mm RPHP13A 24, 30, 36 17-5/8 448 11-1/2 292 RPHP13A 42, 48, 60 21-3/4 552 12-1/4 311 9-1/2 (241) 22-1/4 (565) 26 (660) A B 24 (610) 26 (660) Economizer Adapter (Shipped attached to economizer) 12 (305) FRESH AIR DAMPERS Manual Motorized 13-3/4 (349) Air Intake Hood Motorized Damper Assembly 5 (127) Air Intake Hood 13-3/4 (349) 5 (127) Adjustable Air Slide Damper Adjustable Air Slide Damper - Page 7 -

Accessories Dimensions inches (mm) ROOF CURB F D C 10-1/2 (267) E 2 (51) 1-1/2 (38) A 14.75 (375) B No. A B C D E F in mm in mm in mm in mm in mm in mm RPHP13A 24, 30, 36 40 1016 40 1016 17-1/2 445 20 508 18 457 20 508 RPHP13A42, 48, 60 44-1/8 1121 49 1245 18 457 23-1/2 597 23-1/2 597 20-1/2 521 Revisions Section Page # Description Performance 2 Rating tables revised All specifications and illustrations subject to change without notice and without incurring obligations. RPHP13-100 (05/2013) 2013 Allied Air Enterprises LLC, a Lennox International Inc. Company Printed in the U.S.A. - Page 8 -