Compact Vacuum Regulator Series ITV RoHS For single unit and single unit for manifold ITV Pressure range kpa Power supply voltage 4 VDC ±% to VDC How to Order N Cable connector N Without cable connector S Straight type m L Right angle type m [Option] CE compliant Nil Q CE compliant For detailed information on models for CE, refer to the SMC's website. Current type 4 to ma DC Current type to ma DC Voltage type to VDC Voltage type to VDC Bracket/Option for single unit only Nil Without bracket Flat Bracket Built-in One-touch fittings type For single unit Symbol VACz OUTx Nil U Metric size (Light gray) Inch size (Orange) ø/" ATMc B C L-bracket For manifold Symbol Metric size Nil (Light gray) Inch size U (Orange) VACz ø6 ø/4" OUTx ø/" ATMc ø6 ø/4" Base type Nil M For single unit For manifolds Manifold IITV n Stations stations stations stations Option If a DIN rail longer than the specified stations is required, specify the applicable stations in two digits. (Maximum stations) Example) IITV--7 Note) A DIN rail with the length specified by the number of stations is attached to the manifold. For dimensions of the DIN rail, refer to the external dimensions. How to Order Manifold Assembly (Example) Indicate the part numbers of electro-pneumatic regulators and options to be mounted below the manifold part number. Example) Due to the common supply/exhaust feature, note that different pressure range combinations are not available. IITV- set (Manifold part no.) ITV-MS sets (Vacuum regulator part no. (, stations)) ITV-ML set (Vacuum regulator part no. ( stations)) Indicate part numbers in order starting from the first station on the D side. Note) Combination with having different pressure ranges is not available due to common supply/exhaust features. The asterisk ( ) specifies mounting. Add an asterisk ( ) at the beginning of electro-pneumatic regulator part numbers to be mounted. D side DIN rail 7 ITV-MS ITV-ML Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, CA 48-67-Main Office: (6) 88--Outside Local Area: (8) 8--www.stevenengineering.com
Compact Vacuum Regulator Series ITV Specifications Model Minimum supply pressure Maximum supply pressure Set pressure range Maximum flow rate ITV Set pressure kpa kpa to kpa l/min (ANR) (Supply pressure: kpa) Accessories Bracket Voltage Power supply Current consumption Voltage type Current type Voltage type Input impedance Current type Analog Output signal output Linearity Hysteresis Repeatability Sensitivity Temperature characteristics Operating temperature range Enclosure Connection type For single Metric size unit Inch size Connection size Metric size Manifold Inch size Weight Note ) Cable connector 4 VDC ±%, to VDC Power supply voltage 4 VDC type:. A or less Power supply voltage to VDC type:.8 A or less to VDC, to VDC 4 to ma DC, to ma DC Approximately kω Approximately Ω to VDC (Load impedance: kω or more) Output accuracy: Within ±6% (Full span) Within ±% (Full span) Within.% (Full span) Within ±.% (Full span) Within.% (Full span) Within ±.% (Full span)/ C to C (No condensation) IP6 equivalent Built-in One-touch fittings z, x, c: z, x, c: ø/" z, c: ø6, x: z, c: ø/4", x: ø/" g or less (without option) Note ) Indicates the weight of a single unit. For IITV-n Total weight (g) Stations (n) x + (Weight of end block A, B assembly) + Weight (g) of DIN rail Note ) When there is a downstream flow consumption, pressure may become unstable depending on piping conditions. When using under the conditions equivalent to IP6, connect the fitting or tube to the breathing hole prior to use. (For details, refer to "Specific Product Precautions " on back page ) Flat bracket assembly (including mounting screws) P8 Straight type M8-4DSXMG4 L-bracket assembly (including mounting screws) P8 Right angle type ELWIKA-KV448 PVC M Tighting torque when assembling is. N m. Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, CA 48-67-Main Office: (6) 88--Outside Local Area: (8) 8--www.stevenengineering.com 8
Series ITV Working Principle When the input signal rises, the air supply soloenoid valve q turns ON. Due to this, part of the supply pressure passes through the air supply solenoid valve q and changes to output pressure. This output pressure feeds back to the control circuit r via the pressure sensor e. Here, pressure corrections continue until output pressure becomes proportional to the input signal, enabling output pressure that is proportional to the input signal. Diagram of working principle Power supply and error LED indication Power supply r Control circuit Output signal q Air supply solenoid valve w Exhaust solenoid valve e Pressure sensor VAC ATM OUT Block diagram Supply pressure + r Control circuit q Air supply solenoid valve w Exhaust solenoid valve Output pressure Discharged to atmosphere e Pressure sensor Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, CA 48-67-Main Office: (6) 88--Outside Local Area: (8) 8--www.stevenengineering.com
Compact Vacuum Regulator Series ITV Series ITV Linearity, Hyteresis Repeatability With % of signal input Output deviation factor (% F.S.).. Return Out Output deviation factor (% F.S.).. 7 4 (%F.S.) Count Pressure Characteristics Set pressure: kpa Flow Characteristics Output deviation factor (% F.S.).. Out Return Set pressure (kpa) 4 6 8 kpa kpa 4 kpa 6 kpa 8 kpa kpa 8 6 4.... 4 Supply pressure (kpa) Flow rate (l/min (ANR)) Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, CA 48-67-Main Office: (6) 88--Outside Local Area: (8) 8--www.stevenengineering.com
Series ITV Dimensions For Single Unit 4 x ø6 depth of counterbore x ø6 depth of counterbore. L-bracket M8 x Cable connection thread Flat bracket 6 Port Location No. z x c ITV VAC OUT ATM 8 OUTx VACz ATMc Flat bracket 74 7 Note) When using under the conditions equivalent to IP6, connect the fittings or tube to the breathing hole prior to use. (For details, refer to "Specific Product Precautions " on back page ) Note) Breathing hole (M x.) OUT port (, ø/") 88.7.7 8 VAC port (, ø/") ATM port (, ø/").7 8 L-bracket x M x. thread depth. Bracket mounting hole 4 x ø. x ø. 64 + 8 Minimum bending radius 8 Body (.) Cable connector (4-wire) Straight type 8.7. 7 4 Cable connector (4-wire) Right angle type Minimum bending radius 8 Body 8 M8 x ø.7 4.6 Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, CA 48-67-Main Office: (6) 88--Outside Local Area: (8) 8--www.stevenengineering.com
Compact Vacuum Regulator Series ITV Dimensions Single unit for manifold 6 M8 x Cable connection thread 84 86 Note) Breathing hole (M x.).7 OUT port OUTx (, ø/") 8 8. Note) When using under the conditions equivalent to IP6, connect the fittings or tube to the breathing hole prior to use. (For details, refer to "Specific Product Precautions " on back page ) Bushing assembly 6..7 Note) For dimensions of the cable connector, refer to single unit on page. Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, CA 48-67-Main Office: (6) 88--Outside Local Area: (8) 8--www.stevenengineering.com
Series ITV Dimensions Manifold L L 4 4 4 x M x. thread depth Mounting hole Port Location No. z x c ITV VAC OUT ATM Note) Stations are counted starting from the D side... 6 D side stations U side (8) Dimensions in inch are noted in parentheses. 6. 6. VACz port (ø6, ø/4") 8 8. ATMc port (ø6, ø/4") 4 4 OUTx port (, ø/").7 Note) For dimensions of the cable connector, refer to single unit on page. Manifold stations n L L Weight of DIN rail (g) 6. 7 4 48 7 6. 6 7 7 8. 4 8 8 6 6 4 (mm) 8. 4 Note) Breathing hole (M x.) Note) When using under the conditions equivalent to IP6, connect the fittings or tubing to the breathing hole prior to use. (For details, refer to "Specific Product Precautions " on back page ) Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, CA 48-67-Main Office: (6) 88--Outside Local Area: (8) 8--www.stevenengineering.com