Installation, Operation and Maintenance Manual

Similar documents
CIRCLE SEAL CONTROLS

CIRCLE SEAL CONTROLS

Product Manual. EX40, Version Last Updated: 11/7/16. Product Description:

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

High Pressure Solenoid Valves

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

2001 SERIES CRYOGENIC BAR STOCK BODY VALVES

EH50 Product Manual Version

J Flow Controls Model Numbering

MARFAID Solenoid Valves

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

Airsweep Installation & Maintenance Manual. Airsweep Models VA-06 VA-12 VA-51 SECTION THREE SOLENOID VALVES

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

Dome-Loaded Pressure Reducing BD-Series

SOLENOID CONTROL VALVE

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

EC4 SERIES CRYOGENIC VALVES 1/4 2 Sizes

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

Powers Controls Powertop Two-Way Valves Normally Open

Operating Instructions. Valves Atkomatic Series ATEX and Series ATEX Series Series

Operating and Installation Instructions

Type N550 Snappy Joe Emergency Shutoff Valves

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

t EVAPORATOR PRESSURE REGULATING VALVES

Installation, Operation, and Maintenance Manual

Operating & Maintenance Manual For Steam Conditioning Valve

specification DAtA V R0 pilot operated tank blanket VAlVe, pressure regulating VAlVe SERIES V500

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

Type MR108 Direct-Operated Backpressure Regulator

Installation& Maintenance Instructions

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

Easytork Solenoid Valve IOM

cs200 series commercial / Industrial pressure reducing regulators

NEECO INDUSTRIES INC. INSTRUCTION MANUAL 7 1/16 10K SLAB GATE BODY

COMPANY. Pneumatic Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516

Installation, Operation and Maintenance Instructions

Pneumatic Isolation Module

type 122a three-way Switching Valve

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Installation, Operation & Maintenance Instructions

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

I-799/79V Coil Components

Table of Contents. Automatic Section A B V. Coil Piping Packages A B P P. Water Source Heat Pump Hose Kits A B H K

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

Model Ton Hand Carry Axle Jack P/N: CJ67D0250-1

Type MR105 Direct-Operated Pressure Reducing Regulators

1/2" AIR DRIVEN DIAPHRAGM PUMP

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 )

DA Series Diaphragm Valve

Type EZR Relief Valve or Backpressure Regulator

Product Manual. S&S V-100 Ball Valves 2 though 8 Inch Designs. Introduction: Installation:

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

HARMSCO Hurricane Swing Bolt Water Filters Models: HUR 1X170FL, HUR 3X170FL HUR 5X170FL, & HUR 8X170FL

6SC SERIES MODELS 910F, 910FLW, 920F IRON SWING CHECK VALVE INSTALLATION OPERATION MAINTENANCE GUIDE

MODULATING FLOAT CONTROL VALVE

Cylinder and Valve: AirHawk II Air Mask

PRESSURE RELIEF / SUSTAINING CONTROL VALVES

INSTALLATION/OPERATION/MAINTENANCE MANUAL for the FlowMax REGULATOR

Technical Data TYPE T124 & T134 TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4512A

Model &

Yarway 7100 Series ARC Valve non-filtered design Installation and maintenance instructions

Solenoid Valve Installation Kit

Introduction. Installation. Maintenance. Bill of Materials

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Solenoid Operated Block Valves A2800 Series

Pilot-Operated Regulators

Installation for L1100, L1200, L1200N Series Liquid Level Switches and DVU150, DVU175, and DVU2105/2115/2120 Series Dump Valves. GENERAL INFORMATION

Installation Operation & Maintenance Instructions

Installation, Operation & Maintenance Manual for Flo-Max Couplers Model FM

SERIES ASCO Valves DESCRIPTION OPERATION INSTALLATION. Positioning. Page1of5(Section1of2) I&M No.V9575R3 (Section1of2)

Check Valve AP64 P.149. Vacuum Generator Vacuum Generator Module Vacuum Generator Module AP7 & 70 AP71 AP72. Flow Switch Flow Switch (For high flow)

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

Type 63EGLP Relief Valve

Model RM-1 Riser Manifold Commercial and Residential General Description

Crispin Valves Operating Guide. Crispin

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

Flow-Alert Flow Switch Installation & Maintenance Instructions

PV4 - Compact Shut Off Style Pig Valve IOM - Installation, Operation & Maintenance

Page 1 of 26 Oteco Inc. Houston, Texas

PRESSURE REDUCING CONTROL VALVES

PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE

ALTITUDE CONTROL VALVES FOR ONE WAY FLOW

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

INSTALLATION INSTRUCTIONS 3-POSITION GATE VALVES SIZES Read All Instructions Prior To Installation

Jo-Bell Products. DIVISION OF DALNOR SYSTEMS, INC Sierra Vista Drive Carlsbad NM, Phone: Fax:

Orifice Flange Union Assembly and Orifice Run Installation and Operation Manual

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

1100 Series Piston Type Differential Pressure Gauges

Type N550 Emergency Shutoff Valves. Instruction Manual. Type N550 Emergency Shutoff Valves. Introduction. Specifications. Scope of Manual.

Surplussing Valve SP-COSR-16

WELCOME TO MAGNATROL

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Installation & Parts Manual K-7, K-15, & K-30 Air Actuated & Differential Check Valves

627 Series Pressure Reducing Regulators

Type 63EG Relief Valve or Backpressure Regulator

Transcription:

Installation, Operation and Maintenance Manual Technical Manual EH 1.2

General Information about valve sizing: Valves with a Full Port have an internal seat diameter that is the same as the nominal pipe size, i.e. a 1 inch pipe size valve with a full port has a 1 inch diameter seat. Valves with a Reduced Port have an internal seat diameter that is smaller than the nominal pipe size. The valve s flow coefficient, Cv, is a value that is determined by flow testing for each valve size. Full port valves will have a higher Cv than reduced port valves. The Cv rating for each valve is listed in the tables found in the valve catalog. The definition of Cv is the # of gallons of water that will flow through the valve with a 1 PSI pressure differential when the valve is open. The equations below can be used to determine: Flow Rate, given the Cv and P Cv, given the Flow Rate and P P, given the Flow Rate and Cv Cv = Valve s flow coefficient (dimensionless value) S = Specific Gravity (1.0 for air or water) T = Absolute Temperature in R ( R = F + 460) P 1 = Inlet Pressure in PSIG P = Pressure Differential in PSI across valve in the open position V = Specific Volume in Cubic Feet per Pound Page 2 of 8

Installation: Before installing the valve, make sure the operating pressure, service and electrical requirements are compatible with your installation. Never apply incompatible fluids or exceed the pressure and temperature rating of the valve. Valve should be installed and maintained by qualified personnel only. IMPORTANT: Before installing the valve, be sure the system is clean and free from debris that may become lodged inside the valve preventing proper operation. Valve Orientation: EH30, EH40 and EH50 valves are designed to operate using a horizontal inlet pipe with the outlet facing downwards and the solenoid on top. EH30 valves that are supplied with the Universal Mount option can be installed in any orientation. EH70 valves can be installed in any orientation. The arrow on the valve body indicates the direction of flow. Pipelines need to be properly supported to prevent strains on the valve body. IMPORTANT: To protect valve internals and ensure trouble free operation, install a suitable strainer or filter on the inlet side as close to the valve as possible. Follow manufacturer s recommendations for installation and maintenance. End Connections: Female Pipe Thread: The use of Teflon tape, or other appropriate thread sealant, on all pipe thread connections is recommended. Care must be taken to prevent excess tape from entering the valve. For EH70 valves, always use the hexagonal portion of the valve body casting when applying torque or clamping. Never apply torque or pressure to other areas of the valve. Welded End (EH70 valves only): It is recommended that any end connection requiring welding be performed with the valve internals removed from the valve body. Damage to the seals inside of the valve may occur if temperature rises above 400 F. If necessary, the body may be wrapped with a water soaked rag to help dissipate heat. Ensure that any slag or debris is not allowed to enter the valve. Flanged, Union or other type end connection: Always use appropriately rated, mating end connections when connecting to the valve. Any seals or gaskets should be made from materials compatible with the fluid or valve service. Electrical Connections: Wiring, conduit and conduit connections must comply with National and Local Electrical Codes, as appropriate. Solenoids that are rated as explosion-proof and are being installed in a hazardous atmosphere must have an explosion-proof, conduit isolation fitting installed no more than 1 inch from the solenoid s conduit connection. Page 3 of 8

The standard solenoid enclosure has a 1/2 FNPT conduit connection. The solenoid may be rotated 360 to facilitate wiring connections by loosening the top nut, rotating the solenoid to the desired position then re-tightening the top nut. Lead wires supplied with the solenoid are a minimum of 18 long. The wire gauge size is determined by the solenoid s power requirements and is a minimum of 18 AWG. The wire used to connect to the power source should be the same or heavier gauge wire size as the lead wires. Unless otherwise indicated, all solenoids are designed to operate at ± 10% of the nominal voltage. Check the valve nameplate for specific voltage and amperage requirements. Fuses or circuit breakers are recommended and should be sized according to the inrush amperage and holding amperage requirements of the solenoid (see nameplate or contact the factory, phone: 856-829-4580, email: techsupport@clarkcooper.com). The solenoid should not be cycled continuously more than 4 times per minute, unless it has been designed for a high cycle rate. Wiring diagram: CAUTION: During normal operation, the solenoid can become hot. DO NOT touch solenoid during operation. Allow to cool before handling. IMPORTANT: After the valve has been installed, it is recommended to cycle the valve dry and under normal operating conditions to allow the seals to properly seat under pressure. Basic Information: Pilot Operated valves work by opening a small pilot orifice to relieve pressure above the main piston allowing it to open. Direct Operated valves pull directly on the piston to open the valve. EH30 and EH70 Series valves operate from zero PSI up to the rated pressure. EH40 and EH50 Series valves operate from a minimum pressure of 50 PSI and 100 PSI respectively up to the rated pressure. Note: Pilot orifices and internal bleed holes are relatively small and can become obstructed by particulates in the fluid. Therefore, it is important to run clean fluids through the valve. All EH Series valves are designed to operate with the fluid flowing in one direction. Fluid flows into the valve above the seat and out of the valve below the seat. The valve will not prevent fluid from flowing in the reverse direction, except for the EH50 Series valve equipped with the optional, integrated check valve which will prevent reverse flow. Page 4 of 8

Maintenance and Repairs: It is recommended to periodically inspect the valve to insure that it is operating properly. If the valve is not functioning properly, it can be returned to the factory for a complete failure analysis. Upon authorization, the valve will be restored to like new condition. The valve can also be repaired by qualified personnel in a properly equipped workshop. In many instances, the valve can be repaired while it is still installed in the pipeline. DANGER: NEVER ATTEMPT TO DIS-ASSEMBLE A VALVE THAT IS UNDER PRESSURE. THIS MAY RESULT IN SERIOUS INJURY AND/OR DEATH. These repair and maintenance instructions should be used as a guide. Many Clark-Cooper valves are customized for specific applications. Therefore, these instructions may not provide all the necessary information required to properly service all models. Solenoid Replacement (EH30, EH40, EH50 and EH70): 1. Disconnect the solenoid from the power supply. 2. Remove the top solenoid nut and washer. 3. Remove the solenoid and replace with new solenoid. 4. Replace washer and nut. 5. Position the conduit connection as necessary and tighten the nut. 6. Reconnect the power supply. Piston Assembly Replacement for EH30 valves: 1. Lock out pressure to the valve. The valve inlet and outlet MUST BE at atmospheric pressure (0 PSIG) prior to servicing the valve. 2. Disconnect the solenoid from the power supply. 3. Remove the top solenoid nut, washer and solenoid. 4. Remove the Bonnet Retainer using Spanner Wrench (Part # A35801600000). 5. Lift the bonnet off the valve body and remove the piston assembly. 6. Install new piston assembly and replace the body/bonnet o-ring in the groove on the bottom of the bonnet. 7. Re-assemble the bonnet onto the valve body. 8. Screw the bonnet retainer into place and tighten using the spanner wrench. 9. Re-assemble the solenoid, washer and nut onto the bonnet. 10. Position the conduit connection as necessary and tighten the nut. 11. Reconnect the power supply. Page 5 of 8

Cartridge Assembly Replacement for EH40 and EH50 valves: (EH50 valve illustrated below) 1. Lock out pressure to the valve. The valve inlet and outlet MUST BE at atmospheric pressure (0 PSIG) prior to servicing the valve. 2. Disconnect the solenoid from the power supply. 3. Remove the top solenoid nut, washer and solenoid. 4. Remove the Bonnet Retainer using Spanner Wrench (Part # A35801600000). 5. Remove Cartridge Assembly and Cartridge Gasket. 6. Install new Cartridge Assembly and Gasket. 7. Screw the bonnet retainer into place and tighten using the spanner wrench. 8. Re-assemble the solenoid, washer and nut onto the bonnet. 9. Position the conduit connection as necessary and tighten the nut. 10. Reconnect the power supply. Page 6 of 8

Piston Assembly Replacement for EH70 valves: 1. Lock out pressure to the valve. The valve inlet and outlet MUST BE at atmospheric pressure (0 PSIG) prior to servicing the valve. 2. Disconnect the solenoid from the power supply. 3. Remove the top solenoid nut, washer and solenoid. 4. Remove the Body/Bonnet bolts. 5. Lift the bonnet off the valve body and remove the piston assembly. 6. Install new piston assembly and replace the body/bonnet gasket in the top of the valve body. 7. Re-assemble the bonnet onto the valve body. 8. Tighten the body/bonnet bolts. 9. Re-assemble the solenoid, washer and nut onto the bonnet. 10. Position the conduit connection as necessary and tighten the nut. 11. Reconnect the power supply. Page 7 of 8

Page 8 of 8