U.S.A / CANADA. USA CNS Automation, Inc E. Firestone Blvd. La Mirada, CA Tel : Fax :

Similar documents
RIDE QUALITY. All you need is a hoistway

ELEVATOR S GENERAL FUNCTIONS GUIDE

Features: 1 Compact, Energy Efficient Machine. 2 Controller. 3 Governor. 4 Door Control System. 5 Revolutionary Coated Steel Belts

RIDE QUALITY. All you need is a hoistway

Hitachi Elevator VFI-II

MACHINE ROOM-LESS ELEVATOR

RIDE QUALITY All you need is a hoistway

Creating An Accessible World ELVORON CPL.

ELVORON HOME ELEVATOR

Elvoron Home Elevator

Passenger Elevator with Machine Room

GeN2 Comfort lift. A machine roomless system with unsurpassed levels of comfort, reliability, safety and environmental protection.

Home Elevator. Planning Guide

Machine-room-less electrical gearless solutions (MRLG)

Schindler Schindler Passenger Elevators

Installation plan and power facility plan for Taiwan

I N D I A N S T A T I S T I C A L I N S T I T U T E

Vertical Dreams XJ SIEMENS. Vertispace Cargo Elevator. English. Deutsch. 中文 Français

CHN-EN Otis Elevator Company

Elvoron CPL. Planning Guide

Machine-Room-Less Elevator


Introduction Ecology Safety and Comfort Car Designs 5 7 Hall Design Basic Specifications 9-10 Electrical Installation Entrance Layout Drawings

IRIS enhancing the value of the building...

ELVORON HR DESIGN AND PLANNING GUIDE

ASTRON. Automobile Elevator Moving Solutions with safety and Reliability. MRL Machine Room Less ELEVIO

Premier. Otis Elevator Company is the world's leading manufacturer and maintainer of elevators, escalators and moving walkways.

Midrise Elevator. MRL MR Gearless MR Geared. Elevator Technology (Korea) Export Division

State-of-the-Art Factories For the Environment. For Product Quality. Certification

PASSENGER ELEVATOR MODERNIZATION A CHOICE OF MODERNIZING YOUR ELEVATORS

GFC-L3 ADVANCED TECHNOLOGIES. The Best Helper to Enhance the Efficiency of your Modern Factory GFC-L3. Comfort. Efficiency. Safety.

Schindler 3100 Practical and reliable. Our passenger elevator with all essentials on board. Schindler Passenger Elevators

NIPPON GOODS & CAR LIFT

DESCRIPTION OF OPERATION EcoSpace elevator with KCM831 control

TRIVIUM ENTER ANOTHER DIMENSION

Your Elevator Partner

THE COMPLETE ELEVATOR MODERNIZATION SOLUTION. KONE ReVolution

Orion LU/LA Commercial Elevator OWNER S MANUAL

Built for every day, designed for any style.

Residential Elevator OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Concord Dealer)

Home Elevator. Specifically engineered for residential applications

Schindler 7000 Planning parameters of high-rise elevators.

Schindler 400A Traction Elevator System When less means more

REFERENCE STANDARD RS-18 ELEVATORS AND CONVEYORS REFERENCE STANDARD RS 18-1

SECTION TRACTION ELEVATORS

OPTIONS AND SHAFT DIMENSIONS m/s; kg. KONE MonoSpace 500

Eclipse Gearless Residential Elevators OWNER S MANUAL

Built for every day, designed for any style.

Silens-Pro Top. Machine. Excellence. Ultramodern. Uniquely

in service THE ELEVATOR THAT YOU PLUG IN LIKE A DOMESTIC APPLIANCE

Vertical Dreams XJ SIEMENS. Optima MRL Elevators. English. Deutsch. 中文 Français

ELEVATOR MODERNIZATION. FOR ROYAL SUPERDYNE (ACVV) Models

Schindler 3300 A remarkable style that suits the building. The machine room-less passenger elevator that unifies form and function.

CORRIGENDUM/ ADDENDUM 09 ADDITIONAL REQUIREMENT OF ELEVATOR.

Your Safety is Our Top Priority

Planning Guide. ThyssenKrupp. ThyssenKrupp Access Residential Elevator Division. for Residential Elevators ASME A17.1, Part V, Section 5.

Guide for Inspection of Elevators, Escalators, and Moving Walks


GeN2 TM Mod. Range of application GeN2 Mod 2:1 roping. 450 kg kg kg 8

Schindler 3100 Simple and practical. Our passenger elevator for small residential buildings really gets you moving.

SHAFT DIMENSIONS AND OPTIONS m/s; kg. KONE MonoSpace 700

Built for every day, designed for any style.

luxury & convenience home elevators by

savaria, Eclipse Residential Elevator OWNER'S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer)

Comfort. Smooth Silent Precise. The best sensation is not to notice anything. A dream lifestyle

Smooth Silent Precise. The best sensation is not to notice anything. A dream lifestyle

ARTICLE SAFETY CODES FOR ELEVATORS, ESCALATORS, MANLIFTS AND HOISTS. Elevator Safety

GOING UP IN SPACE. KONE TranSys Passenger

PASSENGER ELEVATORS MACHINE-ROOM-LESS SYSTEM. Designed to European standards

Prolift SCL/Prolift HD

Quality Elevators by Garaventa ELVORON HR. Hydraulic Residential Elevator

Tricon by MCE Data Form Motion Control Engineering Phone (916) Fax: (916)

1.3~2.0 Ton Series Electric/3-Wheel(48Volt)

Creating An Accessible World. genesis SHAFTWAY. Shaftway vertical platform lift for lifting heights up to 14 feet.

Infinity & Infinity HD

NOTES ON ELEVATOR SYSTEMS

Energy Saving Technologies for Elevators

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as an AMENDMENT)

Platforms, hoists and outriggers

Elevator Technology. synergy 100. Fact sheet.

THE ANSWER TO THE CURRENT MRL MARKET REQUIREMENTS. MRL W-Line EXCELLENCE IN COMPONENTS. EMOTIONS IN MOTION

HIGH SPEED ELEVATORS HYUNDAI ELEVATOR INTERNATIONAL SALES & SERVICE NETWORK

PASSENGER ELEVATORS (COMPACT MACHINE ROOM SYSTEM) Series-IP/AP Version 2 Series-IP

Economical and efficient KONE E MonoSpace

Tricon by MCE. Car controller specification. Controller Data Form Motion Control Engineering JER Phone Fax

Specialized in Home/Villa Elevators

Guide for Inspection of Elevators, Escalators, and Moving Walks

Schindler 2600 The freight elevator that makes transportation of heavy loads effortless

Group One Roped Hydraulic. Elevators. as well as many other applications

T O W E R C R A N E. 290 HC tower sections. 8 x 13'-7" (4.14m) = 108'-8" (33.1m) 290 HC base section. 4.14m 13'-7" 290 HC base section

TOWER CRANE. 290 HC tower sections. 290 HC base section. 290 HC reinforced base. 290 HC reinforced base. Configuration III 290 HC Tower 229 ft (69.

Infinity & Infinity HD

THE ELEVATOR WITH A COMPACT MACHINE ROOM

Your Elevator Partner

550 HC tower sections 290 HC tower sections. 2.45m 8'-0" 550 HC tower sections. 290 HC reinforced base. 13'-7" 4.14m. 290 HC reinforced base

MACHINE ROOM-LESS FREIGHT AND SERVICE ELEVATOR. KONE TranSys

3 Wheel Electric Forklift Trucks B13R / 15R / 16R-5 (24V Rear Wheel Drive) 2,500lb to 3,200lb Capacity

MAINTENANCE EVALUATION CHECKLIST ELECTRIC ELEVATORS

Generator Fire Safety: Generator assemblies should be located outside the building.

ELEVATOR & ESCALATOR SYSTEMS. SHENYANG AMTE INDUSTRIES LLC Add.: No. 135, Changjiang Street, Huanggu District, Shenyang, China.

Transcription:

USA CNS Automation, Inc. 14251 E. Firestone Blvd. La Mirada, 90638 Tel : 562-404-1909 Fax : 562-404-1902 U.S.A / NADA NADA CNS Automation, Inc. 14251 E. Firestone Blvd. La Mirada, 90638 Tel : 562-404-1909 Fax : 562-404-1902 HEAD FFICE & FACTR San 136-1, Ami-ri, Bubal-eup, Icheon-si, Gyeonggi-do 467-734, Korea Tel : 82-2-3670-0653/0678 Fax : 82-2-3672-8763~4 www.hyundaielevator.co.kr SEUL FFICE(INT L SALES DIV.) 8F East Bldg, Hyundai Group Bldg., 1-7 eonji-dong, Jongno-gu, Seoul 110-754, Korea Tel : 82-2-3670-0653/0678 Fax : 82-2-3672-8763~4 PASSENGER ELEVATRS - We reserve the right to change designs and specifications for the product development without prior notice. Copyright HUNDAI ELEVATR C., LTD. All rights reserved. Printed in Korea. TALG CDE : C-PELA-E0108/2012.12/1st Edition

Hyundai Elevator Hyundai Elevator, an affiliated company of Hyundai Group, offers its products in more than 50 countries such as the United States, Canada, Japan, Europe, East/West Asia, the Middle East and is recognized for excellence in quality. Hyundai elevators and escalators are known for their exceptional comfort, safety and energy efficiency. Hyundai Elevator Head ffice_the World Class Elevator Test Tower (Hyundai Asan Tower) stands in Icheon, Korea Company Profile Incorporated : May 23, 1984 Number of Employees : 1,304(As of September, 1, 2012) Factory In our 11.5acre(46,484m 2 ) state of the art facility we manufacture products including elevators, logistics automation systems, parking systems, and platform screen doors. (Selection of elevator speed) The selection of elevator speed/model should be made in consideration of the building type, size, use and the anticipated passenger carrying capacity at peak traffic times. R&D Center R & D Center was established in 1986 and employs over 100 employees and is the core of our new product development. Type of Machine Model (Unit:fpm[m/s]) Test Tower Standing 672ft(205m) high, our ultra- high speed test tower, named the Hyundai Asan Tower, was completed in April 2009 and is used to test for vibration, noise, pressure, as well as the reliability and safety of the parts and components related to ultrahigh speed systems. At the Hyundai Asan Tower, you will find the world s fastest elevator running at speeds up to 3600fpm(18m/sec), as well as the 2000fpm(10m/sec), high speed double deck elevator, and the world s fastest 1400fpm(7m/sec) high speed observation elevator. 350(1.75) 200(1.0) 150(0.75) Contents 01 Reliable Products ZER 04 / LUEN 06 02 Advanced Technology Gearless Traction Machine 08 03 Design Design Collection 10 / Ceiling Design & Handrail 17 / Signal Fixtures 18 Standard & ptional Features 20 / Layout Plan 22 / Entrance Design 26 / Power Feeder Data 28 / Works To Be Done By ther Contractors 29 * MRL: Machine-room-less

HUNDAI ELEVATR RELIABLE PRDUCTS Machine-room-less elevators (ZER) The machine roomless elevator ZER is a revolutionary new elevator that eliminates the need for a rooftop machine room through the use of miniaturized traction machines and control panels, allowing increased space utilization, resolution of height and sunlight restriction issues, and more freedom in installation layout and skyline design. 01Reliable Products Increased space efficiency A revolutionary new elevator that maximizes space efficiency through the use of smaller operating and control components that can be installed to the side of the door or in the hoistway, eliminating the need for a separate rooftop machine room. Flexible hoistway layout and skyline design Provides enhanced flexibility in hoistway layout, and more freedom in building roof line design with the elimination of the conventional penthouse type machine room. Reduced building cost Costs are reduced by eliminating the need for machine room construction and installation. Compact gearless traction machine By using a gearless traction machine with permanent magnet synchronous motor, the ZER provides a smoother ride, improved energy savings, and environmentally friendly features. 4HUNDAI ELEVATR C., LTD. PASSENGER ELEVATRS5

HUNDAI ELEVATR RELIABLE PRDUCTS Medium speed gearless elevators (LUEN) The LUEN incorporates a high quality gearless traction machine to a mid/low speed elevator, resulting in highly efficient controls and energy savings. Also, continuous noise and vibration analysis have resulted in increased passenger comfort and a quiet and pleasant ride. 01Reliable Products utstanding passenger experience Gearless traction machine provides a quality ride with the least noise and vibration from the gear mechanism and ropes delivering a smooth and comfortable passenger experience. Energy efficiency Gearless traction machine with permanent magnet synchronous motor increases energy efficiency. Spacious car Interior High ceiling provides a spacious and comfortable experience. Eco-friendly Environmentally-friendly elevator that does not need regular gear oil replacement. 6HUNDAI ELEVATR C., LTD. PASSENGER ELEVATRS7

HUNDAI ELEVATR ADVANCED TECHNLG Gearless Traction Machine 02Advanced Technology With the use of gearless traction machine, smoother ride, improved energy-saving, and environment-friendly features are enhanced. Improved energy savings Gearless traction machines with permanent magnet synchronous motors provide up to 60% energy savings compared to hydraulic elevators. Comfortable ride Noise and vibration level has decreased dramatically and car ride has improved significantly with the use of gearless traction machines with permanent magnet synchronous motors thanks to the lack of tooth gear and rope swing. Environment-friendly components Gearless traction machine is environment-friendly since gear oil is not required. Reduced installation space It can save the building space as it needs smaller machine room space than the conventional. 8HUNDAI ELEVATR C., LTD. PASSENGER ELEVATRS9

DESIGN CLLECTIN DESIGN CLLECTIN REAR VIEW REAR VIEW 03Design Collection FRNT VIEW ENTRANCE FRNT VIEW ENTRANCE GE DESIGN ENTRANCE GE DESIGN ENTRANCE Ceiling CD251A / Painted Steel(P022), Acryl, Painted Steel(P017) Ceiling CD329B / Painted Steel(P023), Skylite 10T Painted Steel(P016) Convective Air Sterilization System Painted Steel(P017) / AJP150 Type Painted Steel(P016), Stainless Mirror(#8), Painted Steel(P016) / AJP150 Type Painted Steel(P017), Entrance column(painted Steel P017) Hall Button HPBU-230BK / Stainless Hairline(#4) Entrance column(painted Steel P016) Hall Button HPBU-230BK / Stainless Hairline(#4) Handrail 1E / Stainless 1 Pipe + Bracket Handrail 1E / Stainless 1 Pipe + Bracket Car s Painted Steel(P017) Car s Painted Steel(P016) perating Push Button *Sub.P. is optional perating Push Button *Sub.P. is optional Car Lantern CLSU-640T / Stainless Hairline(#4) Car Lantern CLSU-640R / Stainless Hairline(#4) Flooring Marble(By thers) Flooring Marble(By thers) 10HUNDAI ELEVATR C., LTD. PASSENGER ELEVATRS11

DESIGN CLLECTIN DESIGN CLLECTIN REAR VIEW REAR VIEW 03Design Collection FRNT VIEW ENTRANCE FRNT VIEW ENTRANCE GE DESIGN ENTRANCE GE DESIGN ENTRANCE Ceiling CD219A / Painted Steel(P022), Skylite 10T Stainless Hairline(#4) Ceiling CD299B / Painted Steel(P023), LED Light, Stainless Hairline(#4) Etching(SE2302) Stainless Hairline(#4), Entrance Column(Stainless Hairline #4) Stainless Hairline(#4) / AJP150 Type LED Down Light, Skylite 10T, Lon Air Filter Stainless Hairline(#4) / AJP150 Type Handrail FL / Stainless Hairline(#4) Hall Button HPBU-230BK / Stainless Hairline(#4) Stainless Hairline(#4), Stainless Hairline(#4) Etching(SE2302), Hall Button HPBU-230BK / Stainless Hairline(#4) Car s Stainless Hairline(#4) Indicator HIPU-D310 / Stainless Hairline(#4) Entrance Column(Stainless Hairline #4) Indicator HIPU-D310 / Stainless Hairline(#4) perating Push Button *Sub.P. is optional Handrail 1E / Stainless 1 Pipe + Bracket Car Lantern CLSU-640T / Stainless Hairline(#4) Car s Stainless Hairline(#4) Flooring Marble(By thers) perating Push Button *Sub.P. is optional Car Lantern CLSU-640T / Stainless Hairline(#4) Flooring Marble(By thers) 12HUNDAI ELEVATR C., LTD. PASSENGER ELEVATRS13

DESIGN CLLECTIN DESIGN CLLECTIN REAR VIEW REAR VIEW 03Design Collection FRNT VIEW ENTRANCE FRNT VIEW ENTRANCE GE DESIGN ENTRANCE GE DESIGN ENTRANCE Ceiling CD251A / Painted Steel(P022), Acryl, Stainless 2B Vibration Steel Ceiling CD251A / Painted Steel(P022), Acryl, Stainless Hairline(#4) Convective Air Sterilization System Stainless 2B Vibration Steel / AJP150 Type Air-Sterilization System Stainless Hairline(#4) / AJP150 Type Stainless 2B Vibration Steel, Stainless Mirror Trim(30mm), Hall Button HPBU-230BK / Stainless Hairline(#4) Stainless Hairline(#4), Stainless Mirror(#8), Hall Button HPBU-230BK / Stainless Hairline(#4) Entrance Column(Stainless 2B Vibration Steel) Indicator HIPU-D310 / Stainless Hairline(#4) Entrance Column(Stainless Hairline #4) Indicator HIPU-D310 / Stainless Hairline(#4) Handrail 1E / Stainless 1 Pipe + Bracket Handrail FL / Stainless Hairline(#4) Car s Stainless 2B Vibration Steel Car s Stainless Hairline(#4) perating Push Button *Sub.P. is optional perating Push Button *Sub.P. is optional Car Lantern CLSU-640T / Stainless Hairline(#4) Car Lantern CLSU-640T / Stainless Hairline(#4) Flooring Marble(By thers) Flooring Marble(By thers) 14HUNDAI ELEVATR C., LTD. PASSENGER ELEVATRS15

DESIGN CLLECTIN Ceiling Design & Handrail Ceiling CD219A Painted Steel(P022), Skylite 10T CD251A Painted Steel(P022), Acrylic, Convective Air Sterilization System REAR VIEW 03Ceiling Design & Handrail CD299B Painted Steel(P023), LED Light, LED Down Light, Skylite 10T CD329B Painted Steel(P022), Skylite 10T, LED Down Light FRNT VIEW ENTRANCE Handrail GE DESIGN ENTRANCE Ceiling CD329B / Skylite 10T, Painted Steel(P022), Stainless 2B Vibration LED Downlight Stainless 2B Vibration / AJP150 Type Stainless 2B Vibration, Stainless Mirror Trim(30mm), Hall Button HPBU-230BK / Stainless Hairline(#4) Entrance Column(Stainless 2B Vibration) Indicator HIPU-D310 / Stainless Hairline(#4) 1E (1 Pipe Stainless) FL (Stainless Hairline Flat Bar) Handrail 1E / Stainless 1 Pipe + Bracket Car s Stainless 2B Vibration perating Push Button *Sub.P. is optional Car Lantern CLSU-640T / Stainless Hairline(#4) Flooring Marble(By thers) 16HUNDAI ELEVATR C., LTD. PASSENGER ELEVATRS17

FF LIGHT L W FF FAN L W FF FAN DR PEN ALARM FF PHTEE L W FF FAN R U N FF ACCESS DR CLSE S T P Signal Fixtures perating s Hall Buttons Hall Position Indicator No Smoking Digital Position Indicator Emergency Light Unit / LED FIREFIGHTER'S SERVICE Fire Service Indicator HPBU- 230B HPBU- 230BK HPIU-D310 03Signal Fixtures Firefighter's Cabinet ANSI 2004 / 05 / 07 Hall Lantern Car Lantern N H I G H N N Function Switch H I G H H I G H 11 12 11 12 9 10 9 10 7 8 7 8 5 6 5 6 3 4 3 4 Push Button 1 2 1 2 STP HELP HELP WHEN FLASHING HELP IS N WA Call Button HLSU- 640R HLSU- 640T CLSU- 640R CLSU- 640T N SMKING PACIT 2500 LBS ELEV N. 01 No Smoking, Capacity and Elevator Number Handsfree phone with Push-to-Talk button and braille Painted Steel MAIN SUB (ptional) Note : At least one 'No Smoking' sign is required. Two or more 'No Smoking' sign is optional. P016 (9.9R 5.0/3.1) P019 (5.1 7.6/1.1) P020 (Metallic Gold) P021 (Metallic Silver) P022 (Black) P023 18HUNDAI ELEVATR C., LTD. PASSENGER ELEVATRS19

Standard & ptional Features Items Descriptions Marks Items Descriptions Marks 1) Selective collective The first call determines the direction of the elevator. All calls opposing the respective direction are serviced after carrying out by the calls of the respective direction. 12) Safety drive During the operation if the car stops between floors, and safety device doesn t work, the car automatically moves to the nearest floor with the low speed. Then, it opens the door to allow the passengers to exit off. 2) Duplex selective collective 2 units of elevator provide the effective service for the common hall calls. 13) Multi-beam door protection Multi-beam from the top to the bottom of the door senses any obstruction caught in the door. It makes the door reopen and stay open until the obstruction is removed. 3) Automatic bypass When a car is 80% loaded, it will automatically bypass all hall calls as the bypass load weighing device is activated. 14) Fire emergency service When a fire breaks out, all cars activated by the switch or fire detector are immediately called to a specified rescue floor for the passenger s safety. 4) Arrival Voice It provides an audible indication in the car that an elevator is about to arrive. 5) Signal fixtures Dot matrix type(moving direction) Hall lantern 15) Anti-nuisance Evaluates the number of people on the car and compares that value to the number of the car calls registered. If the number of car calls exceeds the number of people in the car by the load sensor, the car call exceeding the number of passengers will be cancelled after service nearest call only. 6) Single-side safety edge of door Contact with a passenger or inanimate object causes the doors to stop and reopen automatically. The elevator doesn t start if the door is not completely closed. 7) Ventilation fan Car ventilation is smooth with ventilation fan built-in the ceiling. 16) Voice synthesizer 17) Fireman s emergency service A voice synthesizer with microprocessor makes announcements to inform passengers of various conditions, including landing floor and operation direction, etc. When the fireman s switch located at the main floor lobby and operating panel on the car is activated during a fire or other emergency, a designated car can be called back to a specified floor for fire fighting service. 8) Emergency car lighting In case of a power failure, it automatically turns on the emergency light in the car. 18) HELMN (Hyundai Elevator Computer Monitoring) System This system has various functions, like elevator monitoring and control by a personal computer and modem. 9) Automatic interruption of light and ventilation fan The lights and ventilation fan are automatically turned off to save energy if there is no call registered for a period of time. If there is a call registered again, it works again. 19) Attendant service It is activated when the attendant turns on the ATT switch in the car operating panel to N position. 10) Car door interlock switch When the door is opened, the switch installed at the door operator is activated and keeps the car from moving. During the operation of car, it locks the door completely so as not to open the door from out side. 20) Earthquake operation When the seismic sensor detects and earthquake that exceeds a predetermined level, all cars promptly proceed to land at the nearest floor and park with the doors open to allow passengers to exit out safely. 11) verload features To protect the overload of an elevator, this device sounds a buzzer and the elevator remains stopped at that floor when the number of passengers exceeds the rated capacity. When the excess number of passengers get out of the car, the buzzer stops and the elevator door closes. 21) Parking With the use of the parking switch on the hall button, the car can be parked at a specified floor, during nights and holidays. Notes : 1. : Standard, : ptional 2. Consult Hyundai Elevator if you need the specific features except the above items. 20HUNDAI ELEVATR C., LTD. PASSENGER ELEVATRS21

Layout Plan - ZER(Machine-Room-Less Elevators) 150~350fpm [45~105m/min] Plan of Hoistway Section of Hoistway Standard Dimensions Trolley beam Unit : feet-inch R4 R3 R1 Minimum Room Requirements For ne Car R2 Min.5'(1524) 3' (914) 2 Min.7' (2134) 4" (102) (W)3'x(H)7' M/C Room Entrance 1'-21/4" (362) 9/16" (700) 2'-3 Minimum Space Requirements For ne Car Minimum Height 7'-6" (2286) 5'-8 7/8" (1750) Min.2'-10" (863) Varies 2'-39/16" (700) Section - Double Min.5'-4 1/8" (1628) Min.5'-9" (1753) 7' (2134) verhead(h) Pit Depth (PP) Travel (TR) Total Height (TH) Rated Speed fpm (mpm) Type SS: Single Slide SS: Single Slide C: Center pen Capacity Lbs (kg) 2100 (953) 2500 (1134) 3000 (1361) 3500 (1588) Clear pening P 3'-0" (914) 3'-6" (1067) 3'-6" (1067) 3'-6" (1067) Notes : 1. Speed : 150/200fpm(45/60mpm), 350fpm(105mpm) 2. Maximum travel : 200'(200fpm) or 245'(350fpm) 3. Max number of stops : 20(200fpm) or 24(350fpm) 4. Car height 8'(2438mm) Standard, 9'(2743mm), 10' (3028mm) ptional 5. Entrance height : 7'(2134mm) Standard 6. Machine is located at the top and off to the side. 7. Double door not available. Car inside Clear Dimensions 5'-8" (1727) 6'-8" (2032) 4'-3" (1295) 4'-9" (1448) 5'-5" (1651) Minimum Hoistway Dimensions 1 Car 2 Cars 3 Cars Depth 7'-7" (2311) 8'-7" (2616) 2 15'-6 1/16" (4726) 17'-6" (5334) 3 23'-5 1/8" (7141) 26'-5" (8052) (S) 6'-6" (1981) 7'-0" (2134) 7'-8" (2337) (C) 6'-7" (2007) 7'-1" (2159) 7'-9" (2362) 3' (914) (W)3'x(H)7' M/C Room Entrance Minimum Room Requirements For Two Car 3 Min.8'-4" (2540) CWT R Inspection Receptacle By others Inspection Ladder By others Cinder Concrete & Water Proofed Finish By others Rated Speed fpm (mpm) Capacity verhead Pit Pit Reaction Reaction Force (kn) M/C Room Reaction Suspension Load (kn) Lbs (kg) H PP R (kn) CWT (kn) R1 R2 R3 R4 Trolley1 (TM) Trolley2 (R) 2100 13'-9" (4191) 5'-0" (1524) 71 57 (953) 14'-6" (4420) 5'-5" (1651) 91 73 Unit : feet-inch 65 65 14 24 20 66 4" (102) 4" (102) 2500 13'-9" (4191) 5'-0" (1524) 81 64 (1134) 14'-6" (4420) 5'-5" (1651) 104 82 3000 13'-9" (4191) 5'-0" (1524) 90 70 (1361) 14'-6" (4420) 5'-5" (1651) 115 89 3500 13'-11" (4242) 5'-3" (1600) 86 65 (1588) 14'-6" (4420) 5'-7" (1702) 127 96 70 70 15 26 20 72 76 76 16 27 20 79 78 78 17 29 20 84 Minimum Room Requirements For Three Car (W)3'x(H)7' M/C Room Entrance 3' (914) Notes : 1. If occupied spaced exists below the hoistway, Consult Hyundai Sales Engineer. 2. All dimensions are based on 8-0 cage with 7'-0" entrance door height. 3. Higher car height may affect overhead(h) dimension. 4. For seismic zones, add 1 (26mm) to dimension. 5. When selecting the trolley beam, safety factor needs to be at least level 4. 22HUNDAI ELEVATR C., LTD. PASSENGER ELEVATRS23

Layout Plan - LUEN(Gearless Elevators) 150~350fpm [45~105m/min] Plan of Hoistway & Machine Room Section of Hoistway Standard Dimensions Unit : feet-inch RA (W)3' x (H)7' M/C Room Entrance M Power Source & Switch RB M2 2 4" (102) M "A" verhead (H) 7' (2134) Machine Room Height (MH) Rated Speed fpm (mpm) Capacity Lbs (kg) 2100 (953) 2500 (1134) 3000 (1361) 3500 (1588) 4000 (1814) Type SS: Single Slide SS: Single Slide C: Center pen C: Center pen Clear pening P 3'-0" (914) 3'-6" (1067) 4'-0" (1219) Car Inside Clear Dimension 5'-8" (1727) 6'-8" (2032) 7'-8" (2337) 4'-3" (1295) 4'-9" (1448) 5'-5" (1651) Minimum Hoistway Dimension Minimum Machine Room Dimension 1 Car 2 Cars 3 Cars Depth 1 Car 2 Cars 3 Cars Depth 8'-3 1/2" (2527) 9'-3 1/2" (2832) 9'-3 1/2" (2832) 10'-3 1/2" (3137) 2 16'-11" (5156) 18'-11" (5766) 18'-11" (5766) 20'-11" (6376) 3 25'-6 1/2" (7785) 28'-6 1/2" (8700) 28'-6 1/2" (8700) 31'-6 1/2" (9614) (S) 5'-6" (1676) 6'-0" (1829) 6'-8" (2032) (C) 5'-7 3/16" (1707) 6'-1 1/4" (1860) 6'-9 1/4" (2063) M 9'-3 1/2" (2832) 10'-3 1/2" (3137) 10'-3 1/2" (3137) 11'-3 1/2" ( 3442) M2 18'-11" (5766) 20'-11" (6376) 20'-11" (6376) 22'-11" (6985) M3 27'-6 1/2" (8395) 30'-6 1/2" (9309) 30'-6 1/2" (9309) 33'-6 1/2" (10224) 10'-6" (3200) 11'-0" (3353) 11'-8" (3556) M Total Height (TH) Notes : 1. Speed : 150/200fpm(45/60mpm), 350fpm(105mpm) 2. Maximum travel : 200'(200fpm) or 245'(350fpm) 3. Max number of stops : 20(200fpm) or 24(350fpm) 4. Car height 8'(2438mm) Standard, 9'(2743mm), 10' (3028mm) ptional 5. Entrance height : 7'(2134mm) Standard 6. Front and rear double door available ( CWT at side configuration only) (W)3' x (H)7' M/C Room Entrance (W)3' x (H)7' M/C Room Entrance Power Source & Switch Power Source & Switch M3 3 4" (102) 4" (102) M CWT R Travel (TR) Pit Depth (PP) Inspection Receptacle Inspection Ladder Cinder Concrete & Water Proofed Finish Rated speed fpm (mpm) Capacity verhead Pit Pit Reaction M/C Room Reaction Lbs (kg) H PP R (kn) CWT (kn) RA (kn) RB (kn) 2100 14'-1" (4293) 5'-3" (1600) 70 56 (953) 14'-7" (4445) 5'-6" (1676) 90 72 2500 14'-1" (4293) 5'-3" (1600) 82 65 (1134) 14'-7" (4445) 5'-6" (1676) 104 83 3000 14'-1" (4293) 5'-3" (1600) 91 70 (1361) 14'-7" (4445) 5'-6" (1676) 116 90 3500 14'-1" (4293) 5'-3" (1600) 86 65 (1588) 14'-7" (4445) 5'-6" (1676) 127 97 4000 14'-1" (4293) 5'-3" (1600) 95 72 (1814) 14'-7" (4445) 5'-6" (1676) 141 106 Notes : 1. If occupied spaced exists below the hoistway, Consult Hyundai Sales Engineer. 2. All dimensions are based on 8 0 cage with 7'-0" entrance door height. 3. Higher cage Height may affect overhead(h) dimension. 4. For seismic zones, add 2"(51mm) to dimension. 5. Max. Travel is 75m. 58 105 60 113 66 122 70 129 73 138 Unit : feet-inch 24HUNDAI ELEVATR C., LTD. PASSENGER ELEVATRS25

BPASS FF N FIREMAN BPASS FF N FIREMAN Typical Entrance Layouts Entrance Design Single Slide Center pen depth 4 3/4" (121) Finish AJP150 (Wide Straight & Bolted) Standard Frame () Finish 4" (102) 13/16" (30) 4" (102) Finished wall (By thers) Finish Finish depth Finished wall (By thers) 43/4" (121) Center pen (Section B-B) Finished 4" (102) depth 3 9/16" (90) AJP150 (Wide Straight & Bolted) Standard Frame () 4" (102) 13/16" (30) 4" (102) Finished wall (By thers) AJP150S (Wide Angled & Bolted) Standard Frame () 6" (152) depth 13/16" (30) 6" (152) Finished wall (By thers) 39/16" (90) AJP150S (Wide Angled & Bolted) Standard Frame () 6" (152) 13/16" (30) 6" (152) Single Slide (Section B-B) Finished 4" (102) HH Concrete pening HH+4" HH (Std : 7' (2134)) depth HH Concrete pening HH+4" HH (Std : 7' (2134)) depth B B B B A A A A Finished Floor (By thers) Finished Floor (By thers) 39/16" (90) Finished Floor (By thers) Finished Floor (By thers) 43/4" (121) Note : depth Maximum is 11 3/4"(300mm). Single Slide (Section A-A) Note : depth Maximum is 113/4"(300mm). Center pen (Section A-A) 26HUNDAI ELEVATR C., LTD. PASSENGER ELEVATRS27

Power Feeder Data Works to be Done by ther Contractors ZER(Machine-Room-Less Elevators) 150~350fpm [45~105m/min] Capacity (Lbs) 2100 2500 3000 3500 LUEN(Gearless Elevators) 150~350fpm [45~105m/min] Capacity (Lbs) 2100 2500 3000 3500 4000 Rated Speed fpm (mpm) Rated Speed fpm (mpm) Motor (kw) Motor (kw) 1 Car 2 Cars 1 Car 2 Cars MC (A) Power Supply (KVA) FLU (A) FLAcc (A) FLU (A) FLAcc (A) 1 Car 2 Cars 1 Car 2 Cars 5.9 11.5 23.0 23.0 46.0 20 30 6 11 300(90) 8.8 20.0 40.0 40.0 80.0 20 40 9 17 350(105) 10.3 20.0 40.0 40.0 80.0 30 50 11 19 7.0 13.5 28.0 27.0 56.0 20 30 7 13 300(90) 10.5 23.5 48.0 47.0 96.0 30 50 11 20 350(105) 12.2 23.5 48.0 47.0 96.0 30 50 13 23 8.4 17.0 35.0 34.0 70.0 20 40 9 16 300(90) 12.5 27.0 55.0 54.0 110.0 30 50 13 24 350(105) 14.6 27.0 55.0 54.0 110.0 30 60 15 28 9.9 19.5 40.0 39.0 80.0 30 50 10 19 300(90) 14.8 32.0 64.0 64.0 128.0 30 60 16 28 350(105) 17.3 32.0 64.0 64.0 128.0 40 70 18 33 11.3 22.0 45.0 44.0 90.0 30 50 12 21 300(90) 16.9 36.0 72.0 72.0 144.0 40 70 18 32 350(105) 19.8 36.0 72.0 72.0 144.0 40 70 21 38 MC (A) Power Supply (KVA) FLU (A) FLAcc (A) FLU (A) FLAcc (A) 1 Car 2 Cars 1 Car 2 Cars 5.9 11.5 23.0 23.0 46.0 20 30 6 11 300(90) 8.8 20.0 40.0 40.0 80.0 20 40 9 17 350(105) 10.3 20.0 40.0 40.0 80.0 30 50 11 19 7.0 13.5 27.0 27.0 54.0 20 30 7 13 300(90) 10.5 23.5 47.0 47.0 94.0 30 50 11 20 350(105) 12.2 23.5 47.0 47.0 94.0 30 50 13 23 8.4 17.5 35.0 35.0 70.0 20 40 9 16 300(90) 12.5 27.0 54.0 54.0 108.0 30 50 13 24 350(105) 14.6 27.0 54.0 54.0 108.0 30 60 15 28 9.9 20.0 40.0 40.0 80.0 30 50 10 19 300(90) 14.8 31.0 62.0 62.0 124.0 30 60 16 28 350(105) 17.3 31.0 62.0 62.0 124.0 40 70 18 33 Note : The values in the table above are based on 3 phase 480V. FLU : Full load up current FLAcc : Full load accelerating current Hoistway 1. Hoistway must be constructed to the final layout drawings (LD). 2. The location of attachment support for the top rail bracket is at a critical elevation called out on the hoistway LD. 3. An overhead beam must be provided at the location indicated on the hoistway LD and designed to support 7500lbs per elevator. 4. Provide a clear plumb hoistway with variations from the size shown on the Hyundai layout not to exceed -0 /+1 (25mm) and not less than the clear dimensions shown on the Hyundai LD. 5. Provide a dry, properly framed, enclosed and vented hoistway in accordance with all applicable codes prior to the start of installation. 6. Front entrance wall at main and top landing, or landing below top landing if the controller is located there, is not to be constructed until or after all elevator equipment is installed in the hoistway. Smoke Detectors 1. Provide smoke detectors, location as required, with wiring from the sensing devices to the controllers designated by Hyundai. 2. If sprinklers are installed in the hoistway or machine space, a means to automatically disconnect the main line power supply upon or prior to the application of water is required (unless prohibited by local code). Pit 1. Pit floor must be designed to sustain vertical forces on car and counterweight rails and impact loads on car and counterweight buffers as shown on Hyundai LD. 2. Pit must be clean and dry prior to start of installation. 3. Fixed ladders in each pit as required by governing code, size of pocket and location shown per Hyundai LD 4. Lights must have an external guard and be located at a point where illumination on the pit ladder base is no less than 10 foot candles. Electrical 1. Power Conditions 1) Three phase: Provide a permanent three phase electrical feeder with separate grounding conductor terminating in controller either at the top landing or landing below before the start of the installation. Three phase, 480V, 50/60hz connection is required. If only three phase 208V is available, transformer to convert it to three phase 480V is required. 2) Single Phase: Provide a permanent single phase electrical feeder with a separate grounding conductor terminating in the transformer located at the top of the hoistway before the start of the installation. 120V is required. 2. For temporary electrical connections, 480V, 50/60hz connection is required. If only 220V is available, transformer to convert it to three phase 480V is required and should be available at the start and throughout the elevator installation. 3. Provide a 125V, 15amp single phase branch circuit for the elevator car/light circuits at the start of the installation of the top stop. 4. Provide a permanent light fixture at the top of the hoistway. Illumination specifications and location of the light switches to Hyundai LD. 5. Provide electrical power for lights, tools, welding, and hoisting, etc. 6. Provide one dedicated outside phone line per elevator. And it shall be terminated at the controller. Barricades must meet SHA minimum requirements. 1. Provide guarding and protection of the hoistway during construction. 2. Hoistway Barricades shall be constructed, maintained, and removed by others. 3. Provide a freestanding removable barricade at each hoistway opening at each floor. 4. barricades shall be 42 high, have centerboard and kickboard and withstand 200lbs of lateral force. 5. Provide full entrance screening/mesh in front of all hoistway entrances. Elevator job site Requirements 1. Maintain the temperature and environment of the elevator hoistway and machine room between 41 F(5 C) to 104 F(40 C). 2. The following conditions are required for maintaining elevator performance. * The relative humidity shall be below 90% on monthly average and below 95% on a daily average. * The elevator hoistway shall be finished with mortar or other materials so as to prevent concrete dust. 3. Voltage fluctuation shall be within a range of +5% to -10%. 4. Contact your Hyundai Elevator representative for more information. 28HUNDAI ELEVATR C., LTD. PASSENGER ELEVATRS29