Vortex Flowmeter. digitalyewflo. Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Similar documents
Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Manifolds for DPHarp EJA and EJX Pressure and Differential Pressure Transmitters. Pressure psi (bar) (860) (552) (413) 4.

Instrumentation Manifolds Traditional C13WT series. For DPharp EJX & EJA-E Differential Pressure and Pressure Transmitters

General Specifications

VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification

General Specifications

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

VLM20 In-line Vortex Flowmeter

Armstrong In-Line and Insertion Vortex Flow Meters

Vortex Flow Meter Model DVH

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

Process to Instrument Valves: C13SF Monoflanges For DPharp EJX & EJA-E Pressure Transmitters

Multivariable Vortex Flow Meter

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Variable V Area Flowmeter Rotameter The Original

Multivariable Vortex Flow Meter

General Specifications

F-2600 SERIES INLINE VORTEX FLOW METER

FLEXIM. Solutions for Sulphuric Acid and Oleum Producers and Demanding Industries. PIOX - The superior solution Accurate - Reliable - Safe - Efficient

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Vortex Flowmeter Model DVE

MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Vortex In Line Flow Meter

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Vortex Eggs Delta Flowmeter

F-2500 SERIES VORTEX METER

VORTEX IN-LINE FLOW METERS

Vortex In Line Flow Meter

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

The readings you need, right where you need them. AX Series Vortex Meters

General Specifications

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER

SRT1000 Series THERMAL FLOWMETER

F-2600 SERIES INLINE VORTEX FLOW METER

유량계전문제조업체. Electro Magnetic FLOWMETER

Model CO Compact Orifice for use with Foxboro Differential Pressure Transmitters

General Specifications

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

STEEMCO-MAS Flowmeter for Steam

General Specifications

Detector (for water measurement applications)

The readings you need, right where you need them. AX Series Vortex Meters

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

ORIMAS Mass Flowmeter

STEEMCO Flowmeter for Steam

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

VIM20 Vortex Insertion Flowmeter

OPTISWIRL 4070 Technical Datasheet

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Rosemount DP Flowmeters and Primary Elements

Rosemount 3051CFA Annubar Flowmeter

OPTISWIRL 4070 Technical Datasheet

General Specifications

VIM20 Vortex Insertion Flowmeter

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

General Specifications

VIM20 Vortex Insertion Flowmeter

MASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

General Specifications

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

Rosemount 285 Annubar Primary Element Series

SITRANS FX300 4/289. System Overview. Overview

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

The Multivariable Air Flow Meter

General Specifications

Rosemount 8800D Series Vortex Flowmeter

Rosemount 8800D Series Vortex Flowmeter

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

Transmitting Transducer. Gas/Air Velocity Range:

F-1500 SERIES INSERTION TURBINE FLOW METER

4-20mA, pulse with HART or pulse with RS485 are selectable. No moving parts, no abrasion, non-wearing parts inside, fully welded SS304

Series 8000 Vortex Flow Meter

Measurement Products Measurement made easy. Swirl flowmeters FS4000 Simply fitting your purpose Application guide

TRANSMITTER ATTACHES TO THIS SURFACE

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online...

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Rosemount 8800D Series Vortex Flowmeter

InnovaMass 240 & 241. Multivariable Mass Vortex Flow Meter. FEATURES DESCRIPTION

flow measurement solutions RIM10 series rotor insertion flowmeters

Hot Tap Insertion Vortex

Rosemount DP Flowmeters and Primary Elements

The Multivariable Air Flow Meter

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

VERIS FLOW MEASUREMENT GROUP

Averaging Pitot Tube Flowmeter Catalogue ED IN AUSTRALIA

Technical Data Sheet , Rev HB October Rosemount 8800 Vortex Installation Effects

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification

Model E. Thermostatic Control Valves. Typical applications

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES MEASURING PRINCIPLE

Rosemount 1195 Integral Orifice Primary Element

Rosemount DP Flowmeters and Primary Elements

Transcription:

Vortex meter digitalyewflo Vortex meter Series Bulletin 01F06A02-00E www.yokogawa.com/fld

Series Simple body construction for easy installation and high level of safety 2 Standard Type / Multi-variable Type Reduced Bore Type High Process Temperature / Cryogenic Type Large Size (400 mm) Measurement principle When a shedder bar is placed in a flow, Karman vortices are generated on the downstream side of the bar. The Karman vortices are detected by two piezoelectric elements installed in the upper part of the shedder bar. The vortex frequency is proportional to the flow velocity in a specific range of Reynolds numbers. Therefore, flow velocity or flow rate can be determined by measuring vortex frequency. Shedder bar Karman Vortices Features of the Vortex meter zeasy installation, with flange or wafer process connections. zno zero adjustment. zno moving parts make Vortex meters highly durable and reliable. zthe sensing element and bluff body are combined in a single shedder bar, minimizing the pressure loss. The flowmeter is leak-free with a high degree of safety. zrobust construction of the shedder bar makes measurement at high temperatures (max. 450 C) and high pressure possible. Piezoelectric elements Shedder bar Detector tube

3

Standard Type Yokogawa s proprietary filter (SSP) for digital signal processing analyzes vortex signals and automatically selects the optimum settings for the best possible measurement. Fieldbus communication compatible 4 Noise Reduction Noise caused by strong piping vibration may affect the accuracy of vortex frequency detection. The two piezoelectric elements in the digitalyewflo are installed in a configuration that is polarized, so they are not affected by vibration in the flow or vertical directions. The noise of vortex (lift)- direction vibration is reduced by adjusting the outputs of the piezoelectric elements. Combining these features with the Spectral Signal Processing (SSP) function provides optimum and stable measurement. Piezoelectric elements direction Lift direction Vertical direction WAFER TYPE FLANGE TYPE digitalyewflo s SSP function provides enhanced vibration immunity and advanced diagnostics. In the past some situations required manual adjustment to compensate for piping vibration noise. digitalyewflo is a maintenance-free flowmeter. It has a circuit for analyzing the detected frequency and allows only vortex frequency to pass through the segmented band-pass-filter, thereby accurately identifying and eliminating noise. The Spectral Signal Processing (SSP) function of digitalyewflo only outputs the appropriate vortex frequencies, even under fluctuating flow rate conditions. Input signal Frequency analysis (SSP function) Judged to be noise Judged to be vortex signal Judged to be noise Removed Output Removed Lower Cost of Ownership è Enhanced vibration immunity! No adjustment costs! è Maintenance free! The self-diagnostic function reduces regular maintenance costs. è User-friendly! Parameters are easily set by categorizing frequently used parameters into one group, reducing total maintenance costs!

Reduced Bore Type Minimum measurable flow up to five times lower than conventional vortex flowmeter. Integrated construction with reducers built into the flowmeter body. Integrated construction allows for bore size reduction of up to 2 sizes. Enhanced safety achieved by integrated construction; No leak points! Same face-to-face dimension as the Standard Type makes replacement easier. Same face-to-face dimension Standard Type (DY***) Reduced Bore Type (DY***/R1, /R2) DY***: Nominal size /R1: One size down /R2: Two size down 5 Measurable flow rate range (Sat.Steam, Ope.Pressure 500 kpa, Pipe size 50 mm) Reduced Bore Type R2 DY050/R2 (Detector size: 25 mm) Measurable range: 22 to 475 kg/h Suitable for LOW FLOWRATE Reduced Bore Type R1 DY050/R1 (Detector size: 40 mm) Measurable range: 44 to 1132 kg/h Suitable for LOW FLOWRATE and WIDE RANGE Standard Type DY050 (Detector size: 50 mm) Measurable range: 74 to 1876 kg/h Suitable for WIDER RANGE Lower Cost of Ownership è No need for reducers/expanders or short pipes to achieve the required straight pipe length! Improves safety and reduces installation costs! è Increases the space for installation of additional instrumentation. è Improved stability in measuring low flow ranges! A single unit can perform such measurements, thereby reducing instrumentation costs. New instrumentation using Reduced Bore Type Traditional instrumentation Process piping Process piping Process piping Reducer Short pipe Short pipe Expander Process piping

Multi-variable Type The world s first two-wire Multi-variable vortex flowmeter (with builtin temperature sensor) can directly output the mass flow rate of saturated steam. Shedder bar with built-in temperature sensor has a temperature monitoring function and a mass flow rate calculation function. Shedder bar with built-in temperature sensor: The shedder bar, which is strong enough to be used as a thermo-well, incorporates a RTD sensor (equivalent to Pt1000, Class A) for temperature measurement. SSP function facilitates highly accurate measurement of flow rate over a wide range, even under radically fluctuating temperatures. A combination of the reduced bore and multi-variable types is ideal for saturated steam instrumentation when the flow rate fluctuates largely. Temperature Sensor Built-in temperature sensor housed inside the shedder bar. Based on signals from the temperature sensor, which is protected by the shedder bar serving as a protector tube, the mass flow rate of saturated steam is calculated. Mass flow rate Temperature 6 Temperature monitoring function Readings of flow rate and temperature measurements are displayed simultaneously. uvolumetric flow rate or mass flow rate (Pulse output) ð Totalized value utemperature value (analog) ð Process temperature value control Mass flow rate calculation function The saturated steam curve based on temperature measurement is used to directly output mass flow! Foundation Fieldbus Communication type can measure natural gas based on AGA No.8, general gas and liquid based on DIPPR physical database. u A single digitalyewflo unit can perform highly accurate measurement of saturated steam. u The ultimate solution for energy-efficient steam control u Robust body and shedder bar construction for safer measurement and control u The SSP function facilitates highly accurate measurement even when the boiler is vibrating. uar function block of Foundation Fieldbus Communication type configured by FSA120 FieldMate Navigator realizes high accurate flow measurement of natural gas, general gas and liquid by using built-in temperature sensor or external temperature sensor and pressure sensor. Lower Cost of Ownership è A high level of safety is assured without the expense or installation of a temperature sensor, and additional process connection is not required. è Neither an external output temperature display unit nor a square root extractor is needed. T/P compensator New saturated steam instrumentation of Multi-variable Type Multi-variable Type Upstream side 10D Traditional saturated steam instrumentation of T/P COMP. Pressure transmitter DP transmitter Impulse pipe Valve Downstream side 5D 20D or greater 5D or greater Orifice 3-valve Temp. amp. Resistance temperature detector

High Process Temperature Version / Cryogenic Version For high temperature or cryogenic flow measurement. Measurable temperature range: Maximum +450 C, Minimum -196 C Easy installation and high level of safety with minimum fugitive emission points. Same face-to-face dimension as the Standard Type Simple construction for easy insulation work Available with Reduced Bore Type Available size : High process temperature version: 25 mm to 400 mm Cryogenic version: 15 mm to 100 mm Stainless steel housing Design Converter housing, case and cover material is stainless steel which is durable for seawater damage. Case and cover material: JIS SCS14A, ASTM CF8M stainless steel castings Available size : 15 mm to 400 mm Remote type detector and Remote type converter 7 Beyond Standard Yokogawa's answer to your process needs. ANSI Class 1500 Flange type Design Robust body with ANSI Class 1500 flange is ideal for high-pressure flow measurement. Body material: ASTM F316, JIS SUS F316 or JIS SUS 316 Available Size : 25 mm to 200 mm Butt-welded type Design Direct welding type. Available model : Consult to our sales office. Dual-sensor type Design Constructed two welded vortex flowmeters (two sensors and two converters) output redundant signals. Available model : Consult to our sales office.

Specification Model Fluid to be measured Standard Reduced Bore Multi-Variable digitalyewflo Series Vortex meter (Integral (Option: Reduced Bore Type /R1, /R2) (Option: Multi-Variable Type /MV) type, Remote type detector, Remote type converter) (Option: High Temp. ver. /HT) (Option: High Temp. ver. /HT, Cryogenic ver. /LT) Liquid, Gas, Steam (Avoid multiphase flow and sticky fluids.) Nominal size 15 mm to 400 mm R1: 25 mm to 200 mm, R2: 40 mm to 200 mm 25 mm to 200 mm (250 mm, 300 mm: Special) Accuracy Liquid: ±1.0% of reading (20000 Re Dx10 3 ) Liquid: ±0.75% of reading (Dx10 3 Re) Output signal Process temperature range Process pressure limit Ambient temperature Gas, Steam: ±1.0% of reading ( velocity less than 35 m/s) Gas, Steam: ±1.5% of reading ( velocity 35 m/s to 80 m/s) Dual Output (both analog and pulse output can be obtained simultaneously.) Analog Output: 4-20 ma DC, 2-wire system Transistor Contact Output: Open collector, 3-wire system Pulse, Alarm, Status output are selectable. Contact rating: 30 V DC, 120 ma DC Low level: 0 to 2 V DC -29 C to +250 C (Standard) -196 C to +100 C (option: Cryogenic version) -29 C to +450 C (option: High Process Temperature version) -0.1 MPa to flange rating. -29 C to +80 C (Integral type with Indicator) -29 C to +85 C (Integral type without Indicator) Liquid: ±1.0% of reading (20000 Re) Liquid: ±1.0% of reading (20000 Re Dx10 3 ) Liquid: ±0.75% of reading (Dx10 3 Re) -29 C to +250 C -29 C to +450 C (option: High Process Temperature version) Ambient humidity 5 to 100%RH (Non condensing) Mounting Flange or wafer type JIS10/20/40K, ANSI150/300/600/900 (1500: Special), DIN PN10/16/25/40/60/100/160 Flange type only JIS10/20K, ANSI 150/300 Electrical connection JIS G1/2 Female, ANSI 1/2NPT Female, ISO M20x1.5 Female Explosion protected type TIIS Ex d, FM Ex d, Ex ia, ATEX Ex d, Ex ia, Ex ic, CSA Ex d, Ex ia, IECEx Ex d, Ex ia Material Body: Stainless steel. Nickel Alloy and Carbon steel by request Shedder bar: Duplex stainless steel, stainless steel, Nickel Alloy (option) Gasket: Stainless steel with polytetrafluoroethylene (Teflon) coating Converter housing, case and cover: Aluminum alloy, stainless steel (option) Indication: Upper: FLOWRATE(%), FLOWRATE, *TEMPERATURE(%) Lower: BLANK, TOTAL, *TEMPERATURE *Options available for Multi-variable Type only Communication: HART 5/7; BRAIN; FOUNDATION Fieldbus -29 C to +250 C -29 C to +400 C (option: High Process Temperature version) -29 C to +85 C (Remote type detector) -30 C to +80 C (Remote type converter with Indicator) -40 C to +85 C (Remote type converter without Indicator) Flange or wafer type JIS10/20/40K, ANSI150/300/600/900, DIN PN10/16/25/40 YOKOGAWA ELECTRIC CORPORATION World Headquarters 9-32, Nakacho 2-chome, Musashino-shi, Tokyo 180-8750, Japan http://www.yokogawa.com/ Represented by: YOKOGAWA CORPORATION OF AMERICA 2 Dart Road, Newnan, Georgia 30265, U.S.A. http://www.yokogawa.com/us/ YOKOGAWA EUROPE B.V. Euroweg 2, 3825 HD Amersfoort, The Netherlands http://www.yokogawa.com/eu/ YOKOGAWA ENGINEERING ASIA PTE. LTD. 5 Bedok South Road, Singapore 469270, Singapore http://www.yokogawa.com/sg/ YOKOGAWA CHINA CO., LTD. 3F Tower D, Cartelo Crocodile Building, No.568 West Tianshan Road, Shanghai 200335, China http://www.yokogawa.com/cn/ YOKOGAWA MIDDLE EAST & AFRICA B.S.C.(c) P.O. Box 10070, Manama Building 577, Road 2516, Busaiteen 225, Muharraq, Bahrain http://www.yokogawa.com/bh/ F-L-03E Printed in Japan, 510(KP) [Ed : 04/b] Subject to change without notice. All Rights Reserved, Copyright c 2007, Yokogawa Electric Corporation.